11-1216-003A roc A nE tArnO V LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER 1 HR I SMOKE BARRIER 1 HR FIRE BARRIER /SHAFT WALL 2 HR FIRE BARRIER 2 HR FSMOKE BARRIER 2 HR BARRIER /SHAFT WALL 4 HR FIRE BARRIER SMOKE PARTITION (NON RATED) NON RATED EXIT ACCESS CORRIDOR EXIT PASSAGE 2 HOUR INSTITUTIONAL OCCUPANCY BUSINESS OCCUPANCY ASSEMBLY OCCUPANCY SMOKE COMPARTMENT WALL EXIT EXIT SIGN — HATCH INDICATES EXIT TEXT AND ARROW INDICATES DIRECTION FIRE DEPARTMENT CONNECTION FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER PULL STATION STROBE LIGHT / HORN TOTAL TRAVEL DISTANCE TO AN EXIT TRAVEL DISTANCE TO ADJACENT SMOKE ZONE PROJECT INFORMATION PROJECT NAM E BAPTIST H EAL TH SOU TH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET, SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER— CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 APPLICABLE CODES REFERENCE TAG — BUILDING CODE: 2007 FLORIDA BUILDING Co Dk PIU M$ER LII E SAFETY CQMMENT/tSSUE PLAN FOR IMf'RC +VEIVIENT (PF,I} NFPAIQ! zraa PROVIDED LIFE SAFETY COMMENTS 1, 1 hr Rated wal I not stenciled Add 1 hr stencil Per AHCA req s. 2 2 hr Rated wal I not stenciled Add 2 fir stencil Per AIICA,req's 3 Non Rated wall stenciled Remove wall stencil Per AHC4 req's SAFETY CODE 2006 STAIR /.3 Rem.9ye 1 ilr stencil - Replace with 2 hr CODE W/2009 4 2 hr Rated wall stenciled l HR stencil Per"AkttA req s —STATE FIRE MARSHALL'S RULE 69A1012 FAC: D 10 _ Remove 2 hr stencil - Replace yyith 1 hr FOR PORTABLE 5 1 hr Rated wall stenciled 2HR stencil Per AFILAreq`s NFPA 13 -2002. STANDARD FOR THE 147 18.3,7,4. 6 Unsealed fire xated wall penetrations Seal all pe net ratioris with fi re,oaut king 8.5 -6 + + + + CODE 588 .t8.3.7,a 7 Unsealed smoke wail penetraitions Seal ;aU penetrations with caulking Extend wall:to underside of the floor or WINDOWS NFPA 99 -2005. STANDARD roof dack above -seal any penetrations R Corridor wall is not continous through th,e wait for smoke resistance 19.3162 SMOKE CONTROL DOOR Extend wall to bottom of"structum- ;.seal STANDARD ON FIRE WALLS AND FIRE arty penetrations throu h the walM;avith. ...1 9 1 hr Wall does not go up to deck fire cau,lki ng- add ;lhr stencil Extend veal I to bottor6 of structure can both' 10 Gypsum board goes up on one silde only sides 19.3.6,2 18.x3,7- (4) 11 hoar needs astragal, Add doer astragal tr1.3.6.x1 12 Door needs positive latching _..__ Add positive latching to door ____ _....... _ _.__W.. _ 19.3.6 3,s 13 Door needs closer Add door close r 19,3.x,3,5 14 Door not smoke tight Add smoke seals 19,3,6.3:1 Clearance between bottom of,tha corridor door and the floor covering 15 exceeds lin Add sweela 193,63A 16 No door 'frame rating Install rated doorfrarj*6rfield rate 19.3.6,3.12 17 Label ran door was painted over Install new label 19.3.T.1.12 18 No door rating- needs 45 min install 45 min fire 'rated door orfiei.d, rate 19.1.trT 19 No door rating - needs 90min Install 90 min fire rated doororfie'ldrate 19311 '20 Exit sign missing direction arrow Acid direction arrow 7401? 21 Exit sign not required Remove e xt si n 22 Missing exit sign Add new exit sign , 2,10Al2 Seal large openingTllisoccurs in Level l; where the registration is located, one option is to combine compartments 11-1' 19.1.21 23 6'valI opening in rated wall and 1I 7 ' Gift Shop needs to be.resistantto smoke, 24 it exceeds 500sgft Apply notes: 9, 13 and 14 19.3.E .1(4) 25 Unsealed slab penetration Seat :openinginslab 82.3 25 Hole i,n,,slab for,00nduit; Seat openingin slat+ Verify, they ariK located within a suite, if 27 Med eases openn to corridor not, close roam with smoke resistant wall 1931.4 Penetrations in l.hrwall are seaiedwlth Verify that all peneirationsand head of 28 wrong caulking wall are sealed with proper fire caulkin 81510 Duct penetrating, lhrwall doesn't,see.m Verify fire dampers on all dracts 29 to have fire damper penetrating walls Plywood is,beirig used to seal I emgve plywood and seal penetrations 30 111;1, te.n.e ._tra _ ti_o.n.�s _ w _it ..h proper caulking __ ,,,,, F8C6 . . 3w 1 1111..... 3:1 Access door has broken handle Install new handle 19,3.6.3;5 32 Access door doesn`t have a closer Add access door closer Facility maywanttrl'canside ;rre- routing pipe and conduit to ;cornlply ±,rl th current' 33 Conduit and exhaust pipe in stair well code standards, 7,1.3.2.1(6) 7.2,224:1.1 34 No handrail on side of stairs Fasten new handrail to wall 35 No handrail on either side of stairs Install handrails on both side of stairs 7.21A A- 36 No extension on handrail _.— ___._.._._...._.._.. Replace handrail to have proper extension -- 7.2.2,4,4, �._,w.. Missing door between corridor and 37 microbiology within a suite Add smoke door Missing wall to seal corridor between: 38 soiled utility room and nurse station Add new corridor smoke wail Verify if beam,ls,gravlty loaded, if it is it 39 beam_ needs to be fire�rracrf � �_ 40 w _ .. _. Door needs flush bolts and coordinator Add automatic flush Wt and coord nator, 19.3.6;x.9 There is a 3" pipe above ceiling.thakrs,cgd Seal penetration zitound pipe,witll 'proper 41 not sealed around or capped and close pipe with proper cap 8:5.s 42 -caulking Hole in slab for conduit i9C!r slab Glass doorih lhrWall to corridor needs'to Reolace,dQor with prQperfire rated glass 8,33 ' 43 be rated door 19.3.6,3-1'; Glass wall to corridor,, window opening Verify wall end window,, r.e smoke 44 34 "x34" resistant 'verify that d,�or is,fire rated and add proper label, If not, install new proper fire 45 No tabel on door rated duor'or field rate 19,11.1 46 Door is, missing, knob Add knob to door 193,63 Storage room needs to be rated and Extend wall to bottom of structure - add 47 ceilingtiles are in bad condition 1hr stencil - replace ceilingtiles 48 Doordoesn't have a coordinator Add door coordinator 19.3,6.36 Walls around labs need to be A rated Extend wall to bottom of' structure '- add 49 and doors should be 45 min rated door stencil.- install 45 min rated door Walls around "shaft" doesn't go all the 50 way up to deck and have stencil Verify existence of,shaft, 51 Not an exit_ ldeOtt d pr as a not exit door 7111.813 2 Exit discharge from P -Stair 2 is defleient Take exit designations off stair $3.1,Itemgve doors to provide lipe,pf sight to exit 5312 Add exit Ogpr in Doctor's Lounge 5,3.3 Add new double egress doors to 53 Exit disc_ harge_from P Stair 3 is deficient extend smoke zone 1D 544'M9ve stair do©rto corridor 54:2 Move doer. to Mech. Ranh to corridor 54 Exit discharge-from M13 -Stair Its deficient $4.3,Upgrade walls.to 2hr and add stencil A roc A nE tArnO V LIFE SAFETY PLAN LEGEND 1 HR FIRE BARRIER 1 HR I SMOKE BARRIER 1 HR FIRE BARRIER /SHAFT WALL 2 HR FIRE BARRIER 2 HR FSMOKE BARRIER 2 HR BARRIER /SHAFT WALL 4 HR FIRE BARRIER SMOKE PARTITION (NON RATED) NON RATED EXIT ACCESS CORRIDOR EXIT PASSAGE 2 HOUR INSTITUTIONAL OCCUPANCY BUSINESS OCCUPANCY ASSEMBLY OCCUPANCY SMOKE COMPARTMENT WALL EXIT EXIT SIGN — HATCH INDICATES EXIT TEXT AND ARROW INDICATES DIRECTION FIRE DEPARTMENT CONNECTION FIRE EXTINGUISHER CABINET FIRE EXTINGUISHER PULL STATION STROBE LIGHT / HORN TOTAL TRAVEL DISTANCE TO AN EXIT TRAVEL DISTANCE TO ADJACENT SMOKE ZONE PROJECT INFORMATION PROJECT NAM E BAPTIST H EAL TH SOU TH MIAMI HOSPITAL LIFE SAFETY SURVEY ADDRESS: 6200 SW 73 STREET, SOUTH MIAMI, FL 33143 PROPOSED USE: LIFE SAFETY SURVEY OWNER— CONTACT PERSON: LUIS FERNANDEZ DE CASTRO PHONE: 786 - 6624660 (1) 4) 4+ BUILDING PLANNING OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) F DC MIXED OCCUPANCY? YES NO REQUIRED FIRE SEPARATION: 1 HR FEC FE 0- ?PL-o" „> TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220 — TYPE 11 (2 -2 -2) PARTIAL FOURTH FLOOR LIFE'! SAFETY PLAN SCALE: 1116'=1' -0' EXITING SUMMARY APPLICABLE CODES EXIT TYPE /FACTOR — BUILDING CODE: 2007 FLORIDA BUILDING CODE W/2009 OCCUPANT SUPPLEMENTS AND AIA GUIDELINES FOR PROVIDED DESIGN AND CONSTRUCTION OF HOSPITALS LOAD AND HEALTHCARE FACILITIES -2006 EDITION SLEEPING —FIRE CODE: 2006 NFPA 1. UNIFORM FIRE CODE / 120 SF FLORIDA FIRE PREVENTION CODE 2007 —LIFE SAFETY CODE: NPFA 101 — LIFE SAFETY CODE 2006 STAIR /.3 — ACCESIBILITY CODE: 2007 FLORIDA BUILDING CODE W/2009 Q' SUPPLEMENTS — CH,11 —STATE FIRE MARSHALL'S RULE 69A1012 FAC: D 10 NFPA 10 -2002, STANDARD FOR PORTABLE 44" FIRE EXTINGUISHERS 55 MB —STAIR 1 NFPA 13 -2002. STANDARD FOR THE 147 INSTALLATION OF SPRINKLER SYSTEMS STAIR /.3 NFPA 72 -2002, NATIONAL FIRE ALARM + + + + CODE 588 + + + NFPA 80 -1999, STANDARD FOR FIRE + + + + DOORS AND FIRE WINDOWS NFPA 99 -2005. STANDARD FOR HEALTH- CARE FACILITIES NFPA 105 -2003. SMOKE CONTROL DOOR ASSEMBLIES NFPA 221 -2006, STANDARD ON FIRE WALLS AND FIRE BARRIER WALLS (1) 4) 4+ BUILDING PLANNING OCCUPANCY: INSTITUTIONAL GROUP 1 (FBC 2006) F DC MIXED OCCUPANCY? YES NO REQUIRED FIRE SEPARATION: 1 HR FEC FE 0- ?PL-o" „> TYPE OF CONSTRUCTION CONSTRUCTION TYPE: FBC TYPE IB — NFPA 220 — TYPE 11 (2 -2 -2) PARTIAL FOURTH FLOOR LIFE'! SAFETY PLAN SCALE: 1116'=1' -0' EXITING SUMMARY EXIT TYPE /FACTOR WIDTH IN INCHES CAPACITY IN OCCUPANT COMPARTMENT PROVIDED PERSONS PER PERSON LOAD r 4A SLEEPING 10,835 120 SF 90 3: P —STAIR 1 STAIR /.3 44" 147 Q' D 10 P —STAIR 3 STAIR /.3 44" 147 55 MB —STAIR 1 STAIR /.3 44" 147 240 SF MB —STAIR 2 STAIR /.3 44" 147 189 EXIT CAPACITY AVAILABLE 588 EXIT CAPACITY REQUIRED 189 SMOKE COMPARTMENT SUMMARY SMOKE PRIMARY AREA OCCUPANT OCCUPANT COMPARTMENT USE SF PER PERSON LOAD r 4A SLEEPING 10,835 120 SF 90 D 0 W 4B TREATMENT 13,085 240 SF 55 4C TREATMENT 10,480 240 SF 44 TOTAL - FOURTH LEVEL 34,400 189 • w SALTZ MICHELSON A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266 -2701 sma@saltzmichelson.com N W - 310 U oaf i t E� yk l d,v� ro r ikl Charles Michelson AR0009976 iY Pro eet No.: 21.1 -166 Drawn By: Checked By: LS Date: 09 -12 -11 3 l