11-1210R-005I 18" MIN. R.O. (NO TUBES BEHIND STATION) 26" AS SHOWN POWER CONDUIT TO ELECTRICAL PANEL 322" R.O. AREA ABOVE STATIONS SHALL BE COORDINATED WITH SWISSLOG TO BE KEPT CLEAR OF OBSTRUCTIONS TO TUBING Th 8" MINIMUM CLEARANCE :• :� REQUIRED AROUND PRV FLAP ........... PRESSURE RELIEF VALVE (PRV) BEND I. •:• ;•;• ;• ;• ;• ;. ;• •I �. ' :' WALLS AND FRAMING 1 1 ..... : ;: BY GENERAL I" CONTRACTOR OR OWNER BOLTED 1... COUPLING f I I ` � a , G.C. TO NOTCH TRACK TO FIT STATION LEGS STATION ANCHORED TO SLAB 3 T -3.00 DETAIL 115 VAC SINGLE PHASE 3A POWER, BY ELECTRICAL CONTRACTOR OR OWNER, TERMINATED INSIDE HOUSING. SEE EQUIPMENT ELECTRICAL DETAILS. STATION FURR —IN BY GENERAL CONTRACTOR OR OWNER G.C. TO ORIENT THESE STUDS WITH FLAT SIDE AGAINST STATION HOUSING STATION HOUSING (TYPICAL), REFER TO EQUIPMENT DETAILS FOR DIMENSIONS INLINE PRESSURE RELIEVE VALVE (PRV) ASSEMBLY: FOR STATIONS FED VERTICALLY FROM THE FLOOR ABOVE. U Z J w U Li Az r=0') I r- STATION ANCHORED TO SLAB SIX INCH RECESSED STATION INSTALLATION SCALE: 1 /2" =1' -0" 323 16 7 POWER CONDUIT 58" ENTRY COMMUNICATION CABLE /CONDUIT ENTRY ova • o a 1 173" 10.L1 » 8 Ir 1 t-4:345 16 " 8 BOTTOM 9" 4-4 34„ TRIM FRAME _ /-- NIPPLE 44" 695" 8 218" 328" CONTROL PANEL CARRIER STORAGE RACKS ADJUSTABLE LEG ASSEMBLY RECESSED STATION SPECIFICATIONS POWER REQUIREMENTS 105 to 125 VAC, 1 Ph, 3A, dedicated unswitched circuit, terminated inside the station — supplied duplex outlet. CONTROL REQUIREMENTS Ethernet protocol available. Consult Swisslog. Traditional RS422 systems: 4— conductor Plenum rated PVC insulated cable, #22 AWG shielded twisted pair with ground wire. 5 VDC maximum open circuit voltage, 200 MA maximum short circuit current. Ultra Station requires one 105 to 125V ENVIRONMENTAL REQUIREMENTS Operating Temperature: 0' to 100' F Storage Temperature: —20' to 180' F Relative Humidity: 0% to 90% Weight: 240 lbs. For additional power connection and communication information, see 4/3.00 RECEIVE BIN ('1 D ETA I L PT -3.00 SIX INCH RECESSED STATION SCALE: 1 /2 " =1' -0" Date Created: 1.27.2012 L, Date Plotted: 1.27.2012 File: P: \Florida \Miami \South Miami Hospital \M00450 NICU 3rd Floor \Drawing \M00450- PT300_301.dwg HOLES FOR COMMI IA IIl,AT 1 I/A1 /�Ar-1 I HOLES FOR POWER CONDUIT 4X4 OUTLET BOX. SEE DETAIL 4 ON THIS SHEF� FOR 115VAC TERMINRTIONS z I �I� HATCHED AND DIMENSIONED AREA SHOWS ACCEPTABLE MOUNTING LOCATION FOR OWNER— SUPPLIED ETHERNET JACK INSIDE THE 4" AND 6" RECESSED STATION HOUSINGS. SEE DETAIL 1 FOR ETHERNET SPECIFICATION — TOP VIEW 4" MAXIMUM 1 " MINIMUM 1111111111 TERMINATION BOARD (SEE DETAIL 5a)- - RECESSED STATION TOP COMPARTMENT RECESSED AND ULTRA STATION SPECIFICATIONS: POWER REQUIREMENTS: 105 to 125VAC, 60 Hz, 1 Ph, 3A 4 Dedicated /unswitched circuit required. ._ Ultra Station requires one 105 to 125V C, 6,�'�, M.' dedicated /unswitched circuit per control p ENVIRONMENTAL REQUIREMENTS: %� -: U OPERATING TEMPERATURE: 0 to 100' F STORAGE TEMPERATURE: —20 to 180' F RELATIVE HUMIDITY: 0 to 90% o if+ i� AVZ , L c CONTROL REQUIREMENTS: �U ous 0Zo 4— conductor PVC insulated cable, #22 AWG shielded twisted pair with ground wire. 5VDC maximum open circuit voltage, 200 mA maximum o short circuit current _ ^, �th � M 4 DETAIL r U ow PT -3.00 RECESSED STATION SCALE: N.T.S. � rA en s SIMSS1 Swlsslog Heafthcare Sduhons :P9 g. Phone (800) 525-1841 www Swisslog corn TRANSLOGIC As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of Swisslog Healthcare Solutions. No part thereof shall be copied, disclosed to others, or used in connection with any work or project other than the specific project for which they have been prepared and developed without the written consent of Swisslog Healthcare Solutions. Visual contact with these drawings shall constitute conclusive evidence of acceptance of these restrictions. SOUTH MIAMI HOSPITAL SOUTH MIAMI, FL CTS -630 SIX INCH STATION EQUIPMENT DETAILS DRAWN BY: CHECKED BY: SHEET NUMBER: oMCE: CONCORD WJB I CH SWISSLOG PROJECT NUMBER: PT-3.00 DATE: 2011 /Jan /27 SCALE: AS NOTED M 0 0 4 5 0