RECESSED STATION TOP COMPARTMENT
RECESSED AND ULTRA STATION SPECIFICATIONS:
POWER REQUIREMENTS:
105 to 125VAC, 60 Hz,1 Ph, 3A
Dedicated /unswitched circuit required.
Ultra Station requires one 105 to 125VAC, 60 Hz, 3A
dedicated /unswitched circuit per control panel.
ENVIRONMENTAL REQUIREMENTS:
OPERATING TEMPERATURE: 0 to 100° F
STORAGE TEMPERATURE: -20 to 180° F
RELATIVE HUMIDITY: 0 to 90%
CONTROL REQUIREMENTS:
4- conductor PVC insulated cable, #22 AWG shielded
twisted pair with ground wire. 5VDC maximum open
circuit voltage, 200 mA maximum short circuit current
TERMINATION BOARD
(SEE DETAILS)
SIX INCH BLOWER POWER REQUIREMENTS, FUSING, AND CIRCUIT BREAKERS
SQUARE D
3 PHASE
FULL LOAD
DISCONNECT
FUSE
INVERSE
PART NUMBER
SIX INCH BLOWER DESCRIPTIONS
VOLTAGE
CURRENT
(AMPS)
HP
(CLASS
RK5, TIME
TIME
CIRCUIT
240V OR LESS
HRK30
(VAC)
NEMA 12
DELAYN)
BREAKER
67122103
BLWR ASY, 6inE- Net,460V,w /oCov,w /AF &GS3VF
460
11.5
10
25A, 600V
35A
NOTE:
ELECTRICAL INSTALLATION MUST ALSO MEET ALL NEC AND
ANY SUPERSEDING LOCAL ELECTRICAL CODES.
ADDITIONAL POWER REQUIREMENTS:
115VAC, 60 Hz, 1 Ph, 5.4A Dedicated /unswitched circuit required
CONTROL REQUIREMENTS:
4- conductor PVC insulated cable, 422 AWG shielded twisted pair w /ground wire
5 VDC maximum open circuit voltage, 200 mA maximum short circuit current
MAX. VACUUM /PRESSURE: (at 5000 ft)
3-1/2 psig
MAX, OUTPUT: (at zero pressure and 5000 ft)
165 SCFM for 4 -inch 330 SCFM for 6 -inch
10 6" Blower Wiring & Specifications
Not to scale
REFER TO DETAIL 4 FOR 115VAC
POWER TERMINATIONS INSIDE J -BOX
TO 115 VAC ELECTRICAL
POWER SOURCE (BY OTHERS)
VACUUM BYPASS
VALVE, SEE DETAILS T
DISCONNECT REQUIREMENTS
SQUARE D
3 PHASE
CLASS R
DISCONNECT
ENCLOSURE
VOLTAGE
FUSE KIT
SWITCH
RANGE
H321N
NEMA 1
240V OR LESS
HRK30
H321 NAWK
NEMA 12
H361 N
NEMA 1
0
H361NAWK
NEMA 12
600V OR LESS
HRK30H
REFER TO DETAILS FOR
115VAC POWER
TERMINATIONS INSIDE J -BOX
FRONT VIEW
MOTOR CONTROL ASSEMBLY
POWER OUTLET FOR VACUUM
BYPASS VALVE
PLUG —�
U TRANSFER UNIT
ENCLOSURE
CABLE TIES
f e
FLEX CONDUIT (BY OTHERS) t
SEE DETAILS
1 Vacuum Bypass Valve Wiring
1 1/2 11-011
POWER CONDUIT
ENTRANCE
GROUNDING STUD,
SEE DETAILS
DO
FROM TO NOT
PRECEDING NEXT USE
UNIT UNIT
CONDUIT CLAMP
TYPE SVT OR SV CORD
RUBBER GROMMET SEAL
1/2" CONDUIT TO TRANSFER UNIT
CONDUIT FITTING
RING TERMINAL---/ z
3/16" QUICK CONNECT WITH INSULATORS
7 Vacuum Bypass J -Box
Not to scale
{r �?
Qt 75 A..
O� ,
goa t L
g a
< a2,
'c
Eu� o U.°
3�ac) 0 <C
cn
Mtn,
i
A `n
0
Hw
0
�1
• r a r a �I � -_, 1�
r=
• : .
INCOMING 115VAC TO PTS
EQUIPMENT (BY ELECTRICAL
CONTRACTOR OR OWNER)
SWITCH DUPLEX I BLACK (HOT)
IN
WHITE
(NEUTRAL)
(GROUND)
FACTORY- INSTALLED WIRE
Station, TU, Blower 115 V.A.C. Connections
4x4 Outlet Box Inside Units
Not to scale
SIL AL ]IF 19
vvlss�'10
TRA1 SLOGIC
Swisslog Healthcare Solutions
Phone: (800) 525 -1841
www.swisslog.com
As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of
Swisslog Healthcare Solutions. No part thereof shall be copied, disclosed to others, or used in connection with any work or project
other than the specific project for which they have been prepared and developed without the written consent of Swisslog
Healthcare Solutions. Visual contact with these drawings stall constitute conclusive evidence of acceptance of these restrictions.
South Miami Hospital
Miami, FL
Clinical Expansion
CTS -630 Matrix ESP
SWISSLOGPROJECTNUMBER L08290
DATE 2011 /Aug/24 DRAWN BY - CHECKED BY -
SCALE As indicated °ffICE Concord
W
Electrical Details
LU
ta PT -41 0
W
TRANSFER UNIT SPECIFICATIONS
DRIVE MECHANISM: Electromechanical
POWER REQUIREMENTS:
105 to 125VAC, 60 Hz,1 Ph, 3A
0
Dedicated / unswitched circuit required
ENVIRONMENTAL REQUIREMENTS:
OPERATING TEMPERATURE: 0 to 100° F
000
STORAGE TEMPERATURE: -20 to 180° F
COMMUNICATION
RELATIVE HUMIDITY: 0 to
CABLE ENTRANCE
90%
BACK VIEW
MAXIMUM VACUUM OR PRESSURE: 4 psig
POSITIONING TIME: Typically 2 seconds (3 seconds
maximum)
CONTROL REQUIREMENTS:
4- conductor PVC insulated cable, #22 AWG shielded
1X4 Transfer Unit shown. 1x2 and 1x6 Units are
twisted pair with ground wire. 5VDC maximum open
similar.
circuit voltage, 200 mA maximum short circuit current
4 Transfer Unit Wirin
Not to scale
GROUNDING STUD,
SEE DETAILS
DO
FROM TO NOT
PRECEDING NEXT USE
UNIT UNIT
CONDUIT CLAMP
TYPE SVT OR SV CORD
RUBBER GROMMET SEAL
1/2" CONDUIT TO TRANSFER UNIT
CONDUIT FITTING
RING TERMINAL---/ z
3/16" QUICK CONNECT WITH INSULATORS
7 Vacuum Bypass J -Box
Not to scale
{r �?
Qt 75 A..
O� ,
goa t L
g a
< a2,
'c
Eu� o U.°
3�ac) 0 <C
cn
Mtn,
i
A `n
0
Hw
0
�1
• r a r a �I � -_, 1�
r=
• : .
INCOMING 115VAC TO PTS
EQUIPMENT (BY ELECTRICAL
CONTRACTOR OR OWNER)
SWITCH DUPLEX I BLACK (HOT)
IN
WHITE
(NEUTRAL)
(GROUND)
FACTORY- INSTALLED WIRE
Station, TU, Blower 115 V.A.C. Connections
4x4 Outlet Box Inside Units
Not to scale
SIL AL ]IF 19
vvlss�'10
TRA1 SLOGIC
Swisslog Healthcare Solutions
Phone: (800) 525 -1841
www.swisslog.com
As instruments of service, all designs, ideas, and information shown on these drawings are and shall remain the property of
Swisslog Healthcare Solutions. No part thereof shall be copied, disclosed to others, or used in connection with any work or project
other than the specific project for which they have been prepared and developed without the written consent of Swisslog
Healthcare Solutions. Visual contact with these drawings stall constitute conclusive evidence of acceptance of these restrictions.
South Miami Hospital
Miami, FL
Clinical Expansion
CTS -630 Matrix ESP
SWISSLOGPROJECTNUMBER L08290
DATE 2011 /Aug/24 DRAWN BY - CHECKED BY -
SCALE As indicated °ffICE Concord
W
Electrical Details
LU
ta PT -41 0
W