Loading...
11-1103-006EMERGENCY 1500KVA ATO 1500KVA PREFERRED 1500KVA FPL_VAULT _ _ _ _ _ CENTRAL ENERGY PLAN - - -- - - - - -- - -- ------------------------------------------------------------------------------------------- 3000A BUS DUCT ,, 3000A BUS DUCT NMSB1 NMSB2 3000A BUS 3000A BUS 480/277V 0 3000A 3000A 480/277V 65KAIC NC MI NC M2 65KAIC 3000A T1 � 1 NO 1200AT 800AT ) 900ATF 600AT 600AT 1000AT 800AT 800AT 600AT 900AT 300AT 600AT i)800AF 6 400AT 600AT 600AT 1200AT 1660OAT J J / 1 OOAT LSI G SPARE SPARE 800.4 1000.4 600.4 600.4 800.4 600.4 1000.4 F3-00- .3 600.3 600.4 400.4 600.4 600.4 (4 SETS) 4 #250 KCMIL T T 1DL VIA ATS -1 ATS -3 MAIN BLDG 1 #2 /OG IN 3 "C 1NHDX 1MCC 2DL VIA CHILLER #2 CHILLER #3 ATS -4 ATS -2 ATS -11 500KVA VIA 500KVA XMFR Ll oe,noH u AFFECTED PANELS - EXISTING TO ,RrtaAIN Y i 1 - 3U K VA 1EQL1 EQUIP. BRANCH SYSTEM 1NHD1 800A BUS 480/277V 2205AT�) 250AT, 2255AT n 100A 60A ATS -E 8MCC CWP #3 CWP #2 ATS -8 260A LIFE SAFETY BRANCH 35KAIC LSDPA c FE SAFET YSTEM G 800 KW G 800 KW G 800 KW 480/277V 480/277V 480/277V F1 2 0 0.41 11200.41 1200.4 5 SETS OF 4 #500KCMIL, 250 #G IN 3 1/2 "C NSB2 SWB 1600A BUS 480/277V 65KAIC 400 \ 1200AF 400AT � J 1000AT ATS -5 5 SETS OF 4 #500KCMIL, 250 #G IN 3 1 /2 "C G 800 KW 480/277V 1200.4 (5 SETS) - 4 #750KCM -4 "C. MSN2 SWB 2000A BUS 480/277V 2000A MSBH4 v ,) v 800AF V 120OAT 0 800AT 0 1200AT 0 5AT 0 �1200AT ATS -E 1600AF PARALLELING SWITCHBOARD 1200AT 3P 480/277V; 5000A BUS NORTH 5000A BUS SPARE MSBH4 EDP1, 1200A BUS 480/277\L EDP3 1200A BUS 480/277V SPACE 0 J 100A / 100A ) 150A / 150A ) 200A 400A \ 600A 600A 400A 1 600A \ 1000A 400A SPARE I I I J I I J I I I J 4 J Q ,L4J. �. I_IJ_V.`h.l I LJU�'t L.. 1pril 2l, 2008 �M"&M= Ms ESSENTIAL SYSTEM - - - - -- AVAILABLE FAULT 1600AT 1600AF 1200AT 1600AF 1200AT ATS -E 1600AF PARALLELING SWITCHBOARD 1200AT 3P 480/277V; 5000A BUS NORTH 5000A BUS N11.ry N11, F'L:33143 TOWER 5000A BUS 34464.6 EDP4 1600AF 1600AF ) 1600AF SPACE 1600AF SPACE 480. 1200AT 1200AT ) 1200AT 480. 1200AT EDP1, 1200A BUS 480/277\L EDP3 1200A BUS 480/277V SPACE 0 J 100A / 100A ) 150A / 150A ) 200A 400A \ 600A 600A 400A 1 600A \ 1000A 400A SPARE I I I J I I J I I I J 4 J Q ,L4J. �. I_IJ_V.`h.l I LJU�'t L.. 1pril 2l, 2008 �M"&M= Ms VOLTAGE - - - - -- AVAILABLE FAULT ----- - - - - -- CURRENT 1000A L -L ATS -E ATS -1 NORTH NORTH ATS -4 ATS -9 N11.ry N11, F'L:33143 TOWER TOWER 34464.6 EDP4 FPL MAIN (ATS -1) FIRE PUMP 8.0 600A BUS i EXISITING ONE-LINE ELE V 1 SCALE: NTS 480/277V SPACE SPACE SPACE eN ATS -4N ),50A 250AT v 400ATv 400AT v )250AF 150AT v )400AF 400AT ALDIAGRAM ATS ATS -2LS ATS 2 ATS 3 ATS 1 ATS 2C MAIN (5 SETS) 4 #750KCM -4 "C. PAVILION SWBD MSN1 2000A BUS 2000A 480/277V � ).1 1200AT� � 600AT � � 800AT „ � 600AT � � 800AT PP1 ATS -10 MCCN ATS -9 HM (PAVILLION) (PAVILLION) (PAVILLION) Mark Karris P(,)Nvci' SyAmis C ''ustomer Pr« ject .NI anagcr 305 - 387 -6664 GENERAL NOTES: A. REFER TO SHEET E4.00 FOR FEEDER SCHEDULE AND TRANSFORMER SCHEDULE. KEYED NOTES: ow FAULT ANALYSIS SUMMARY� 1pril 2l, 2008 �M"&M= Ms ATS -6 VOLTAGE - - - - -- AVAILABLE FAULT ----- - - - - -- CURRENT 1000A L -L StIC'ITI - MIAN411I0SPITAL 7400 S\V 72 ST BUS ATS112 EQUIPMENT 38855.5 N11.ry N11, F'L:33143 BUS ATS#6 BRANCH 34464.6 2.6 FPL MAIN 50KAIC 51849.01 8.0 PNL 1EQHD2 480. 33502.2 Re- Available Fault Current for SOt 111 MIAMI I'IOSPI' AI 480. 31339.8 Dear SOUTH MIAMI HOSPITAL: PNL 1EQL1 208. 1837.2 Thank Nou t6r contacting fTL about the av ti able fault current at SOC;TH NIi Ldil 480. 47709.9 HOSPITAL. Based Oil the pl MS you have pi ovided dated April 21 2008, the calculated 480. 43752.5 available dwee phase fault current at the trans former Secondary terminals is estimated to 480. 23038.7 be 51819 symmetricai amperes at 277/480 wilts. The tc ansfio mer is protected by a 65 800.4 208. anip type K case. This eal: ul ited svinnietrical fault c urreni is not intended L`ot use as the 0.6 basis fUr motor starting calculation's and does not include: r Q u 1EQHD3 I ConsideraLion tier any motor contribution Or I MARK: REMARKS: • Fault, cinant ;;tsti'nrnretr�. Ilecause- of potei'ttial input oil uansf'ormer si /e and fault current WIN, changes i,11 I equipment or load will be need to be commulicated in �vritirig. This fault current BRANCH inf6rination is based oil the FPI, distribution . ys(etii iio%v in place and the oustomer SYSTEM I system represented in the plaits. As the construction project progrc,sses any questum or nil'orni ttion )+tu may noted can be QdltllI)Mnn.atcd throagli lne. I havc uneLoscd ray business card for easy rvIuctict; and lock forward to I'iearing fivrri you in the near tUture , Sincerely, Mark Karris P(,)Nvci' SyAmis C ''ustomer Pr« ject .NI anagcr 305 - 387 -6664 GENERAL NOTES: A. REFER TO SHEET E4.00 FOR FEEDER SCHEDULE AND TRANSFORMER SCHEDULE. KEYED NOTES: ow i FAULT ANALYSIS SUMMARY� -- �M"&M= Ms ----------------------------------- BUS NAME VOLTAGE - - - - -- AVAILABLE FAULT ----- - - - - -- CURRENT mtz L -L 3 PHASE X/R UiE /GRND X/R BUS ATS112 480. 38855.5 2.9 BUS ATS#6 480. 34464.6 2.6 FPL MAIN 480. 51849.01 8.0 PNL 1EQHD2 480. 33502.2 2.5 PNL 1EQHD3 480. 31339.8 2.5 PNL 1EQL1 208. 1837.2 0.5 PNL NMS82 480. 47709.9 4.2 SWB NSB2 480. 43752.5 ,. 3.7 XF 1EQL1 PRI 480. 23038.7 0- 1.0 XF 1EQL1 SEC 208. 1920.0 0.6 FAULT ANALYSIS REPORT COMPLETED OJ N i O f L C� 1 N mtz >� m� CAM ilk o. o` O O O cc) a� m 'O a N `t vi Ln Lo C N O 16 P O O H OO N t�-0 O CM C7 D LZ O 0 N �� z w q: E Lo N O X % C cwt U Q o N .- O IU U CD N .� O - L I Qw ,gX .m Q- C P� 0) U 0 U 0- � eL Iu OJ N Q u REVISIONS MARK: REMARKS: J a �w � 0: mow - caw a�a n CL Sao 0 T . FAQ a 7882 �? tJ t YAK-Z-F_-71, . Job No: t 411427.000 Date: 08-26 -2011 Sheet Title: EXISTING ONE -LI`E ELECTRICAL DIAGRAM Sheet No: E3.00 II