11-1004-001NEW 8 CONCI BEAM (2) -05 (2) -"6 i'3 TIE; (F'c =4 FINISI - GENERAL STRUCTURAL NOTES: I I SLAB - REPAIR PROCEDURE I.- GENERAL: I.- REMOVE ALL DAMAGED OR UNSOUND CONCRETE. THE CONTRACTOR SHALL COORDINATE THESE PR4U11NCsS WITH THE 2: SAID CUT THE PERIMETER OF THE REPAIR AREA FORMING A SHOULDER PERPENDICULAR cYi4-rinle-: FACILITIES IN THE UIORKINCs AREA. TO THE SUBSTRATE. _ t L _ L L POTENTIAL CONFLICTS SHALL 5E TRANSMITTED TO 3.- CHIP OUT THE CONCRETE TO EXPOSE THE ENTIRE CIRCUMFERENCE OF THE REBAR - l ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE WORK. IN ST AT LEAST CONTRACTOR TO PROVIDE ADEQUATE TIME FOR RESPONSE FROM ENGINEER. 2.- CONCRETE: ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 4,000 PSI IN 28 DAPS. AC- ;GREGATE TO 5E CLEAN AND WELL GRADED, MAXIMUM SIZE P. CONCRETE SLUMP: 3" MIN, TO 5" MAX. VERTICAL CONCRETE DROP NOT TO EXCEED 8' -0" 3.- CONCRETE COVER: TO BE AS FOLLOWS: BOTTOM TOP SIDES SEAMS 11/2 11 11/2 11 11/2 11 4.- REINFORCING STEEL: TO 5E NEW HIGH STRENGTH BILLET STEEL DEFORMED AS PER ASTM A-305, AND CONFORMING TO ASTM A-615, GRADE 60. REINFORCING STEEL TO 5E DETAILED AND FABRICATED IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE OF DETAILING REINFORCING CONCRETE STRUCTURES ", AND THE ACI BUILDING CODE 318, LATEST. BUBMIT SHOP DRAWINGS FOR APPROVAL. 5.- ANCHORING EPDXY: FOR ANCHORNG REINFORCING STEEL IN EXISTING CONCRETE, USE HILTI HIT RE 500 EPDXY ADHESIVE ANCHOR OR EQUAL. OTHER AVAILABLE EPDXIES ARE MADE 5Y SIMPSON, ULTRA BOND OR RAWL. DRILL HOLES 1 /S" BIGGER THAN THE DIAMETER OF THE REINFORCING STEEL (STEEL ROD). THE OTHERWISE NOTED IN THESE PLANS, OR Ut4LESS OTHERWISE INSTRCUTED BY THE MANUFACTURERS ECOMMENDATIONS. S E C T I O N EXISTING 6" CONC. SLA5 FIELD VERIFY EL. 0' -0" TOP OF EXISTING FIRST FLOOR SLAB FINISHED GRADE _1 03,m HOOKED 5AR5 x 1' -011 LONG AT 1811c /c. DRILL AND EPDXY INTO EXISTING CONCRETE 5EAM AT CENTERLINE OF BEAM, USE HILTI HIT RE500 EPDXY ADHESIVE 'ANCHOR. DRILL AND EPDXY TOP 4 50TTOM REINFORCING 6" INTO EXISTING CONCRETE COLUMNS. USE HILTI HIT RE500 EPDXY ADHESIVE ANCHOR, TYPICAL EACH 5AR- G.G. NOTE: AVOID CONFLICTS WITH COLUMN VERTICAL REINFORCING. G.C. NOTE: ( #) DENOTES EXISTING PIPE FIELD VERIFY EXACT DIAMETER AND LOCATIONS, E' i, (NG/�11x2011 ONC. WLUMI t/ REMOVAL SHALL CONTINUE ALONG THE LENGTH OF THE REINI =ORC C EEL 6 OF THE UNCORRODED REBAR 15 OBSERVED. EXCAVATE CONCRETE TO A MINIMUM DEPTH OF 3/4" BELOW THE RE5AR TO ENABLE AN EXAMINATION OF THE LOSS OF CROSS- SECTION AND TO ALLOW FOR NEW MATERIAL TO COMPLETELY ENCAPSULATE THE REBAR 4.- VERTICAL AND HORIZONTAL SURFACES SHALL BE LEFT ROUGHENED WITH AT LEAST A 1/4" AMPLITUDE. 5.- SANDBLAST THE CONCRETE AND EXP05ED RE5AR INSERT NEW BARS OF EQUAL DIAMETER NEXT TO THOSE THAT HAVE DETERIORATED BY MORE THAN 150. ALL NEW STEEL SHALL BE ASTM A -615 GRADE 60. LAP SPLICES SHALL 5E IN ACCORDANCE WITH ACI 318 -05. 6.- COAT ALL NEW AND EXISTING RE5AR WITH 51KA ARMATEC 110 EPOCEM. i.- PATCH WITH SIKAREPAIR 223 FOLLOWING THE MANUFACTURER'S INSTRUCTIONS. S.- REPAIRS TO CONFORM TO ORIGINAL MEMBER SHAPE AND SIZE. EXISTING (8 "x18 ") CONC. BEAM TO BE REPAIRED, FIELD VERIFY (1) -05 x 3' -0" LONG AT TOP 2 AND AT 50TTOM OF EX I ST'G 5 -1 PIPE DENOTES DAMAGED AREA UNDER SLAB, SE= PLAN FOR LOCATION AND SLAB REPAIR PROCEDURE NOTE ABOVE, TYPICAL. CRACK IN BEAM, SEE REPAIR PROCEDURE NOTE -A 5ELOW. 4'411 MIN. Sf�LICE, TYPI NEW CONCRETE BEAM EXISTING GRADE rjoy, (f) L 4" I /611 PROVIDE A SLEEVE 2" LARGER THAN PIPE DIAMETER THRU NEW S E C T I O N CONCRETE BEAM. �_ISCALE: P =1' -O" CRACKED BEAM - REPAIR PROCEDURE NOTE -A: FILL EXISTING CRACK WITH SIKADUR 35, HI -MOD LV OR SIMILAR 5Y MEANS OF PRESSURE INJECTION. USE 51KADUR 33 (OR SIMILAR), TO SEAL CRACKS AND SECURE INJECTION PORTS. EXISTING 6 "x24" CONC. COLUMN BEYOND PROVIDE A SLEEVE 211 LARGER THAN PIPE DIAMETER THRU NEW CONCRETE SEAM. All f I II I I I 14 I I I— — - - - - -- - - -- L---- I I I I EL. +0' -0" T. O. EXISTING I SLAB EXISTING I CONCRETE EAM I 5ELOW TO BE REPAIRED A D UP NEW CONC. 5 AM L — = = 5ELOW, SEE EXISTING r I SECTION 1 4 STAIR 1 I I I 2 I 1 r I S -1 AREA DENO ES S -1 REPAIR UND R SLA5, SEE SLA5 I REPAIR I I I L----- - -__ -- PROCEDURE NOTE I r -- — — - -- — — — — - THIS SHEET, - VERIFY EXACT AREA. I . I I I I I- 11[101 '11"11111 r IIIII'1 PARTIAL FIRST FLOOR PLAN (FOR REFERENCE ONLY) r4( =!~q�� rs •1 Ar l: I(.! v i.�.`!� AS C-E I ^i.l+iti A� IV ��,_.=LDING DEPT. tJ!r,r.'I -DP.DE COUNTY IRE DEPARTMENT • STRUCTURAL SECTION BL G;� PER1.111 FIRE ALARM FIRE SUPPRESSION =TA ER MAII EXT. DATE�� I .r { 'jhD--D_A DONNELL, DUQUESNE & ALBAISA, P.A. 4930 S.W. i4th COL Miami, Florida. 331 ,5 Fax: 305.666.5259 State of Florida - Authorization No. 1306 website: www.ddaeng.com Job #2011 -35-A V 4� c . - •�- �CE/Vs. 0RIDP•'���� • A� REVISIONS: tF � 3 r� - — ti-'flROJECT NAME: .. _ •SMH,- CRAWL SPACE 91 AS REPAIR UNDER FIRST FLOOR PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 UUMM. NV. LU11 -J.1-A SCALE: "DATE: 08 -12 -2011 DRAWN: DDA CHECKED: DDA CADD FILE: DDA DRAWING TITLE: PARTIAL FLOOR PLAN - ••4w GENERAL NOTES ,. SECTIONS SHEET NO. S -1#