10-818-058a O O N N W 0 n GROUP ALL DISCONNECTS AND DEVICES TOGETHER. I TYPICAL FOR ALL ELEVATOR HEAT DETECTORS COORDINATE ; INDICATING SHUT CONTACT RATINGS WITH CONTROL FIRE ALARM MODULE OFF VALVE VOLTAGE FOR ELEVATOR R CAB LIGHTS NEW FIRE ALARM FOR ELEVATOR I TAMPER SWITCH 2000 SPRINLE CONTROL CIRCUIT. , CONTROLS (TYPICAL) FEEDER BREAKERS TRANSFORMER ; HEAD (TYPICAL) SHALL BE SHUNT \\\`� XXX SMOKE DETECTOR TRIP (TYPICAL) EQUIP. ; ° SYSTEM I FUSED uj ~ ELEVATOR POWER SHUNT DISCONNECT J ° -- SEE DRAWING EXXX TRIP CONTROL OCP & ; SWITCH w"# TYPICAL FLOOR FOR ELEVATOR POWER. DISCONNECT I ELEVATOR HOISTWAY MOTOR I ELECTRIC CLOSET ELEVATOR MACHINE ROOM TYPICAL ELEVATOR SHUNT TRIP SCHEMATIC DETAIL NTS MACHINE ROOM NOTES: 1ST FLOOR I. MULTIPLE ELEVATORS IN COMMON SHAFTS SHALL USE THE SAME SHUNT TRIP CIRCUIT. PIT 2. PROVIDE SHUNT TRIP OPERATORS ON CIRCUIT BREAKERS SERVING THE ELEVATORS. THE CIRCUIT BREAKERS 1350 HEAT DETECTOR SHALL BE LOCATED OUTSIDE OF THE MACHINE ROOM. (TYPICAL) 3, COORDINATE ENTIRE INSTALLATION WITH THE ELEVATOR INSTALLER. 4. THE CONTROL CIRCUIT TO SHUTDOWN ELEVATOR POWER SHALL BE MONITORED FOR THE PRESENCE OF NOTES: OPERATING VOLTAGE. LOSS OF VOLTAGE TO THE CONTROL CIRCUIT FOR THE DISCONNECTION MEANS SHALL 1. LOBBY SMOKE DETECTOR REQUIRED AT ALL LEVELS. LOBBY AND CAUSE A SUPERVISORY SIGNAL TO BE INDICATED AT THE CONTROL PANEL AND REMOTE ANNUNCIATOR. EQUIPMENT ROOM SMOKE DETECTORS SHALL INITIATE PHASE -1 RECALL. 5. THE ADDRESSABLE MODULES SHALL BE INSTALLED WITHIN 3 FEET OF THE ELEVATOR CONTROLLER FOR 2.135 0HEAT DETECTOR TO AUTOMATICALLY DISCONNECT POWER TO THE PHASE 2 RECALL. COORDINATE EXACT REQUIREMENTS WITH ELEVATOR VENDOR AND SIMPLEX. ELEVATOR PRIOR TO THE APPLICATION OF WATER, HYDRALIC ELEVATOR FIRE ALARM R INTERCONNECTING DIAGRAM P2�, �, ,— I/2 x12" AIR TERMINAL 3/4C. MIN. TYPICAL REFER TO FLOOR PLANS —FOR QUANTITY OF DEVICES EXISTING F F F FACP FIRST FLOOR FIRE ALARM RISER DIAGRAM NO SCALE FIRE ALARM SYSTEM NOTES: A. CONTRACTOR SHALL REFER TO SPECIFICATIONS. B. CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING VENDOR SHOP DRAWINGS INDICATING ALL MODEL NUMBERS, WIRING REQUIREMENTS AND BATTERY CALCULATIONS. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY FLORIDA REGISTERED ENGINEER. C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL SYSTEMS EQUIPMENT AND CABLE AND ALL INSTALLATIONS. D. REFER TO FIRE ALARM MANUFACTURERS' RECOMMENDATIONS FOR CONDUIT AND CONDUCTOR SIZE AND TYPES. REFER TO SPECIFICATIONS. E. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HARDWARE AND SOFTWARE TO SUPPORT EXTENSION OF FIRE ALARM SYSTEM. F. VISUAL DEVICES TO BE IN SYNC WITH EACH OTHER AND AUDIBLE DEVICES TO BE IN SYNC WITH EACH OTHER. G. AUDIBLE AND VISUAL DEVICES TO BE ON DIFFERENT CIRCUITS. H. STROBES TO BE 75 CANDELA EVERYWHERE. I. VOLTAGE DROP AND BATTERY LOAD CALCULATIONS TO BE PROVIDED AND VERIFIED AT SUBMITTAL PROCESS. J. FIRE ALARM SYSTEM SHALL BE NETWORKED WITH EXISTING SYSTEM. K. FURNISH TVSS PER SPECIFICATIONS ON ALL COPPER CABLING ENTERING THE BUILDING. L. THE CONTRACTOR SHALL PROVIDE CONNECTION TO THE OWNERS EXISTING FIRE ALARM SYSTEM. PROVIDE ALL NECESSARY SYSTEM CABINETS, POWER SUPPLIES, MICRO-CONTROLLERS, KEYBOARD DISPLAYS. LED DISPLAYS, BATTERIES, PERIPHERAL DEVICES, VOICE EVACUATION SYSTEMS, ETC. FOR A COMPLETE AND FUNCTIONING SYSTEM. FIRE ALARM SYSTEM COMPONENTS SHALL MATCH EXISTING. M. THE SYSTEM SHALL COMPLY WITH ALL CURRENT, APPLICABLE CODES INCLUDING THE FOLLOWING: 1. NATIONAL ELECTRICAL CODE ( NEC) 2. NATIONAL FIRE PROTECTION AGENCY a. NFPA 72 Edition b. NFPA 101 Life Safety Code 3. ALL APPLICABLE UL STANDARDS 4. AMERI CANS WI TH DI SABI LI TI ES ACT ( ADA) 5. LOCAL CODE REQUIREMENTS N. CONTROL PANEL 1. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY HARDWARE AND SOFTWARE PROGRAMMING NECESSARY TO ACCOMMODATE MODIFICATIONS INDICATED ON DRAWINGS. 0. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE EXISTING FIRE ALARM PROTECTION UNTIL NEW DEVICES HAVE BEEN PROPERLY CERTIFIED AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. ALL EXISTING WIRING, BOXES, CONDUITS SERVING THE DEVICES TO BE REMOVED SHALL BE DEMOLISHED. ALL INACTIVE WIRING SHALL BE LABELLED 'ABANDONED. DO NOT USE.' P. THE CONTRACTOR SHALL PROVIDE A RECORD OF COMPLETION FOR THE FIRE ALARM SYSTEM AND A SENSITIVITY REPORT FOR ALL SMOKE AND DUCT DETECTORS INSTALLED IN THE PROJECT AREA. Q. COORDINATE THE SHUTDOWN OF AIR HANDLER UNITS, EXHAUST FANS, ETC WITHIN THE PROJECT AREA WITH DIVISION 15. GREATER THAN 4' -0 ", NOT TO EXCEED 20' -0' V -4" MAXIMUM (TYPICAL FOUR CORNERS) \ E V -4" MAXIMUM (TYPICAL FOUR CORNERS) SECONDARY BONDING WIRE GREATER THAN 4'-0 ", NOT TO EXCEED 20' -0" li V NOTE: WHERE THE METAL BODY IS LESS THAN 3 /dNCHES THICK, A CONTINUOUS GROUND CONDUCTOR (NOT SHOWN HERE) PROVIDING TWO PATHS TO GROUND SHALL BE REQUIRED TO BOND ALL AIR TERMINALS. TYPICAL POINT SPACING DETAIL SECONDARY BONDING WIRE REVISIONS= SMOKE Q DETECTOR MACHINE ROOM Q 135° HEAT DETECTOR INDICATING S1 ;U- ' ?` 2000 SPRINKLER OFF VALVE" HEAD k TAMPER ' SW:.TCI-. J (TYPICAL) A �r „� 11 CAB ��Nt°� SMOKE, °'DETECTOR (TYPICAL) .;x _ Z , Ca M Q F,i�l HOISTWAY z0 W Z <( co cr --- o X 286° W SPRINKLER HEAD Q N in� N M PIT W 0 N Ln HEAT DETECTOR W °o (D I­- NOTES: PON* b 1. LOBBY SMOKE DETECTOR REQUIRED AT ALL LEVELS. LOBBY AND EQUIPMENT ROOM SMOKE DETECTORS SHALL INITIATE PHASE -1 RECALL. 2. 135° HEAT DETECTOR TO AUTOMATICALLY DISCONNECT POWER TO THE ELEVATOR PRIOR TO THE APPLICATION OF WATER, LOCATE WITHIN 2' OF SPRINKLER HEAD. TRACTION ELEVATOR FIRE ALARM INTERCONNECTING DIAGRAM SEAL PENETRATIMIC Cn AC TO MAINTAIN R WALL FOR FIRE RATED WALL PENETRATIONS bate ,k con _ o b p 0 (jr) Lu pj �U� 4 O''7 Q t: Smltr Beckman , Reid, Inc. 600`West Hillsboro !Suite 300 Deerfield Beach, FL 33441 (954)421 -1260 'FAX: (954) 421'14 6 ;i www.ssr- mc.com Firm Certification - EB- 0000857 John E. Moulder PE -.33200 Michael A.SWe d PE,-'657Q1 r nen ieDavis PE -PE SSR JOB # 1032045.0V 4, ?8i rl JI Q P ' Ww J DRAWN: rte` CHE, �4 firtq�a�� Y DATE . ila 06 ° 30 -;10 S��ALE�tai, SfC�LJ #`r0.J i$1��5 R t';h'�,a'i4Ya. •.ya; . �C�� , �f 6,ry,,�� a b tr � 't � �, n 1' dYl Y4k:jI i�x t i� ✓ � A p kffl�l�i��h1.�'� ���c i � r . Sleet Noofw� 1 OF JOB 201013