10-818-047c Ire N w / ID Q) / 0 Ln O N Ir1 0 0 0 N (\j rl-) E 4v -i- z c� U C C a N M u 0 0 N 0 CL no DEMOLITION LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN EXISTING TO BE REMOVED --- EMPLOYEE ELEVATOR #3 DEMOLITION PLAN AT GROUND LEVEL I�IL� oErnouTioN GENERAL NOTES:. A. LIGHT FIXTURES AND SWITCHES WITHIN THE ELEVATOR MACHINE ROOM SHALL BE EXISTING TO REMAIN. B. EXISTING SERVICE RECEPTACLES SHALL BE EXISTING TO REMAIN. C. EXISTING ELEVATOR CAB LIGHT SHALL BE REMOVED AND REPLACED WITH NEW AND TO RECEIVE NEW LIFE SAFETY CIRCUIT FOR CONECTION TO NEW LIGHTS. D. REMOVE EXISTING ELEVATOR MOTOR AND PUMP WIRING. E. DISCONNECT AND REPLACE EXISTING ELEVATOR PIT SUMP PUMP. REMOVE RECEPTACE SERVING SUMP PUMP; REMOVE CONDUIT AND WIRES BACK TO SOURCE OF POWER, DEMOLITION KEYED NOTES: D1 EXISTING EXHAUST FAN TO BE REMOVED. REMOVE CONDUIT AND WIRES BACK TO SOURCE OF POWER. D2 EXISTING STORAGE CABINET TO BE REMOVED AND TURNED OVER TO OWNER. D3 EXISTING PANEL TO BE DEMOLISHED ALONG WITH ASSOCIATED FEEDER. EXISTING BRANCH FEEDERS SHALL BE DISCONNECTED BUT MAINTAINED FOR CONNECTION TO NEW PANEL. REFER TO NEW WORK ON THIS SHEET. EXISTING BRANCH CIRCUITS NOT IDENTIFIED ON PANEL DIRECTORY SHALL BE TRACED, IDENTIFIED AND CONNECTED TO NEW REPLACEMENT PANEL. NEW WORK GENERAL NOTES: A. CONTRACTOR SHALL PROVIDE WIRE GUARDS FOR EXISTING LIGHT FIXTURES AS REQUIRED WITHIN THE ELEVATOR MACHINE ROOM. B. HEAT DETECTORS SHALL BE INSTALLED WITHIN 24" OF SPINKLER HEADS, C. CONTRACTOR SHALL FURNISH AND INSTALL NEW WIRING FOR PUMPING UNIT MOTOR, PUMPS AND VALVES. D. FURNISH AND INSTALL NEW EQUIPMENT BRANCH CIRCUIT, E. FURNISH AND INSTALL NEW LIFE SAFETY CIRCUIT FOR ELEVATOR CAB LIGHTS. F. LIGHT SWITCH IN MACHINE ROOM SHALL BE LOCATED WITHIN 18' OF LOCK JAMB SIDE OF ACCESS DOOR. G. GFI RECEPTACLES TO BE FURNISHED AND INSTALLED ON WALLS OF THE MACHINE ROOM. H. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE SERVICE RECEPTACLES WITHIN THE ELEVATOR MACHINE ROOM AND ELEVATOR PIT WITH THE EQUIPMENT VENDOR. I. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE ELEVATOR PIT LIGHTS WITH THE EQUIPMENT VENDOR. J. CONTRACTOR SHALL COORDINATE THE REPLACEMENT OF THE EXISTING SUMP PUMP WITH ALL TRADES. THE NEW SUMP PUMP CONTROLLER LOCATION SHALL BE COORDINATED ON SITE WITH THE OWNER'S REPRESENTATIVE. PROVIDE ALL REQUIRED SIGNAL WIRING AND CONDUIT FROM SUMP PUMP TO CONTROLLER. INSTALL PER MANUFACTURES REQUIREMENTS. REFER TO TYPICAL SUMP PUMP CONNECTION DIAGRAM ON SHEET E2.3. K. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE NEW OIL INTERCEPTOR WITH ALL TRADES. THE OIL INTERCEPTOR MONITORING PANEL LOCATION SHALL BE COORDINATED ON SITE WITH THE OWNER'S REPRESENTATIVE. PROVIDE ALL REQUIRED SIGNAL WIRING AND CONDUIT FROM OIL INTERCEPTOR TO MONITORING PANEL. INSTALL PER MANUFACTURES REQUIREMENTS. REFER TO TYPICAL OIL INTERCEPTOR CONNECTION DIAGRAM SHEET E2.3. NEW WORK KEYED NOTES: NEW CONSTRUCTION I1 O"FEND SYMBOL DESCRIPTION .................................... ..............................: EXISTING TO REMAIN NEW CONSTRUCTION EMPLOYEE ELEVATOR ELECTRICAL � NEW WORK PLAN AT 01 11 21 4' 81 12' (D LOCKABLE, HEAVY DUTY DISCONNECT SWITCH FOR ELEVATOR CONTROLLER; FURNISH AND INSTALL FUSES PER MANUFACTURER RECOMMENDATIONS. MAKE FINAL CONNECTIONS TO ELEVATOR CONTROLLER AS REQUIRED. FIELD COORDINATE EXACT LOCATION. CONTRACTOR SHALL PROVIDE FACEPLATE INDENTIFYING SOURCE OF POWER. �2 CONNECT TO LIFE SAFETY CIRCUIT. COORDINATE THE INSTALLATION OF NEW CAB LIGHTS WITH OWNER /VENDOR AND RECIRCUIT AS REQUIRED. POWER FOR "AC- 3A' /'AC -3B' RECEIVED FROM CONDENSER UNIT THROUGH FIELD - SUPPLIED INTERCONNECTED WIRING. �4 CONDENSER UNIT "COND- 3A' /'COND -313". FOLD COORDINATE LOCATION OF DISCONNECT SWITCH. NEW 30KVA TRANSFORMER '1HE8' TO BE STACKED ON TOP OF EXISTING 45KVA TRANSFORMER. REFER TO STACKED TRANSFORMER DETAIL ON SHEET E2.8 FOR ADDITIONAL INFORMATION. #3 GROUNG LEVEL - POWER LEVEL - LIGHTING_ PAVILION BUILDING ' 0 EMPLOYEE ELEV. V 3 PLO E'S P RKING G RAGE EDUCATION CENTER REVISIONS: A A 0 0 0 Ln Ln �00 N in Ln !n z ' O Q �° �i Q j :v X Q � Q Q LL. L-1 O (n zo w= U� Q �, Ox Li.l Q I wV O� j� / tND Iow b ff o 0 O I- QU �W C) . ry Q o Q SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A.8WW -J PE -66701 Dunnie Davie PE - 68688 SSR JOB # 1032045.0 z� Q Q J U W f- n rr U # OW 0::� W CD .Q W W � Z � W W _J 0;6 - J W o w z W —� O O O (D n :�E :�EWI- WC-)<C DRAWN: CHECKED: DATE: 06 -30 -10 1,/ r Aa# � ',�aY it . `�F � Aeb p• b LOCATION PLAN GROUND LEVEL NORTH b is 4 °%'a • U -) s 4� b �� tdd4+44 � i � s ! y fti t4 l.7 l 1P Sheet No. E2.5 or- J013 # 201013