10-818-0431. DEMOLITION LEGEND ffL DESCRIPTION ELEVATOR EXISTING TO REMAIN NEW NEW EXISTING TO BE REMOVED SERVICE ELEVATOR #8 DEMOLITION PLAN AT ROOF LEVEL - ELECT 0' F 2' 4' 8' 12' MOUNT TO ELEVA PIT WALL EPTACLE SHALL BE WIRED AD OF SWITCHING SERVICE SYMBOL ELEVATOR ELEVATOR #8 NEW NEW WORK WORK AT GROUND PLAN_,AT CONTRACTOR SHALL FURNISH AND INSTALL NEW ELEVATOR PUSH BUTTON ASSEMBLY. COORDINATE FLOOR REQUIREMENTS WITH VENDOR ROOF PIT LEVEL -ELECT E. - POWER 0' 1' 2' 4' 8' 12' RICAL RICAL_ N 1) NEW CONSTRUCTION LEGEND SYMBOL DESCRIPTION ELEVATOR EXISTING TO REMAIN NEW NEW CONSTRUCTION SERVILE NEW WORK GENERAL NOTES: ELEVATOR #8 NEW ELEVATOR MACHINE ROOM. WORK B. HEAT DETECTORS SHALL BE INSTALLED WITHIN 24' OF SPINKLER HEADS. PLAN_,AT CONTRACTOR SHALL FURNISH AND INSTALL NEW ELEVATOR PUSH BUTTON ASSEMBLY. COORDINATE REQUIREMENTS WITH VENDOR ROOF D. LEVEL E. - POWER F. LIGHT SWITCH IN MACHINE ROOM SHALL BE LOCATED WITHIN 18" OF LOCK JAMB SIDE OF ACCESS DOOR. 0' 1' 2' 4' 8' 12' DEMOLITION GENERAL NOTES: A. LIGHT FIX 1 URES AND SWITCHES WITHIN THE ELEVATOR MACHINE ROOM SHALL BE EXISTING TO REMAIN. B. EXISTING SERVICE RECEPTACLES SHALL BE EXISTING TO REMAIN. C. EXISTING ELEVATOR CAB LIGHT SHALL BE REMOVED AND REPLACED WITH NEW AND TO RECEIVE NEW LIFE SAFETY CIRCUIT FOR CONECTION TO NEW LIGHTS. D. EXISTING ELEVATOR PUSH BUTTON ASSEMBLY TO BE REMOVED AND TO BE REPLACED WITH NEW. DEMOLITION KEYED NOTES:. D1 EXISTING ELEVATOR DISCONNECT SWITCH TO BE RE -FED. REMOVE EXISTING SERVICE FEEDERS BACK TO SOURCE OF POWER. D2 EXISTING EXHAUST FAN TO BE REMOVED. REMOVE CONDUIT AND WIRES BACK TO SOURCE OF POWER. D3 EXISTING ELEVATOR SHUNT TRIP BREAKER TO BE REMOVED AND RELOCATED. COORDINATE NEW LOCATION WITH OWNER /VENDOR. D4 EXISTING ELEVATOR CAB LIGHTS DISCONNECT TO REMAIN AND TO RECEIVE NEW LIFE SAFETY CIRCUIT. .Ma i Qv; d rp' SERVICE ELEVATOR "8 LIGHTING PLAN AT ROOF LEVEL 1! - LIGHTING Rm N M-F-A 0 NORTH TOWER O VISITOR'S PARKING GARAGE SEKVICE ELEV. # 8 PAVILION BUILDING LOCATION PLAN,,, ROOF LEVEL NORTH REVISIONS: A 0 0 0 �L0 r. N I'n Lfl M z 1 W tD O_ 0 4 OM QI^ _ }C Q LL. LL O V) za co W = � Q O w Q W I O �o �I o W V) w� C� 0 . pmI 12 � 0 x a 0.1 0 a e � 0� o QU LU f-- g e T DC � Q o Q hstSmith Reckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 John E. M..Ider PE - 99200 Michael A.8te d PE 65701 Donn in Dg ie PE 58509 SSR JOB # 1032045.0 i W Q U oc) 0 F-- # W O W W I— ZJ Q W Ld W J Z J W 0 L LLI I— O U —1 0 O I2:� W W I-- () r-) Q DRAWN: CHECKED: D�I�TE 06 -30 -10 S ,�(L e „a is . .�.,i> •� t l S E2.1 or- JOB U 2M13 i i a NEW WORK GENERAL NOTES: A. CONTRACTOR SHALL PROVIDE WIRE GUARDS FOR EXISTING LIGHT FIXTURES AS REQUIRED WITHIN THE ELEVATOR MACHINE ROOM. B. HEAT DETECTORS SHALL BE INSTALLED WITHIN 24' OF SPINKLER HEADS. C. CONTRACTOR SHALL FURNISH AND INSTALL NEW ELEVATOR PUSH BUTTON ASSEMBLY. COORDINATE REQUIREMENTS WITH VENDOR D. FURNISH AND INSTALL NEW EQUIPMENT BRANCH CIRCUIT. E. FURNISH AND INSTALL NEW LIFE SAFETY CIRCUIT FOR ELEVATOR CAB LIGHTS. F. LIGHT SWITCH IN MACHINE ROOM SHALL BE LOCATED WITHIN 18" OF LOCK JAMB SIDE OF ACCESS DOOR. G. GFI RECEPTACLES TO BE FURNISHED AND INSTALLED ON ALL WALLS OF THE MACHINE ROOM. H. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE SERVICE RECEPTACLES WITHIN THE ELEVATOR MACHINE ROOM AND ELEVATOR PIT WITH THE EQUIPMENT VENDOR. {4„ 1. CONTRACTOR SHALL COORDINATE THE LOCATION OF THE ELEVATOR PIT LIGHTS WITH THE EQUIPMENT VENDOR. NEW WORK KEYED NOTES: 10 I LOCKABLE, HEAVY DUTY DISCONNECT SWITCH FOR ELEVATOR CONTROLLER; FURNISH AND INSTALL FUSES PER MANUFACTURER RECOMMENDATIONS. MAKE FINAL CONNECTIONS TO ELEVATOR CONTROLLER AS REQUIRED. FIELD COORDINATE EXACT LOCATION. CONTRACTOR SHALL PROVIDE FACEPLATE IDENTIFYING I' SOURCE OF POWER. O CONNECT TO LIFE SAFETY CIRCUIT. COORDINATE THE INSTALLATION OF NEW CAB LIGHTS WITH OWNER /VENDOR AND RECIRCUIT AS REQUIRED. POWER FOR "AC- 8A' / "AC -8B' RECEIVED FROM CONDENSER UNIT THROUGH FIELD - SUPPLIED INTERCONNECTED WIRING. �4 CONDENSER UNIT "COND- SA " / "COND -8B" ON ROOF. FIELD COORDINATE LOCATION OF DISCONNECT SWITCH ' AND SUPPORT ON GALVANIZED UNISTRUT RACK. CONNECT UNIT TO EXISTING LIGHTNING PROTECTION SYSTEM. REFER TO LIGHTNING PROTECTION DETAIL ON SHEET EG.O FOR ADDITIONAL INFORMATION. SERVICE ELEVATOR "8 LIGHTING PLAN AT ROOF LEVEL 1! - LIGHTING Rm N M-F-A 0 NORTH TOWER O VISITOR'S PARKING GARAGE SEKVICE ELEV. # 8 PAVILION BUILDING LOCATION PLAN,,, ROOF LEVEL NORTH REVISIONS: A 0 0 0 �L0 r. N I'n Lfl M z 1 W tD O_ 0 4 OM QI^ _ }C Q LL. LL O V) za co W = � Q O w Q W I O �o �I o W V) w� C� 0 . pmI 12 � 0 x a 0.1 0 a e � 0� o QU LU f-- g e T DC � Q o Q hstSmith Reckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 John E. M..Ider PE - 99200 Michael A.8te d PE 65701 Donn in Dg ie PE 58509 SSR JOB # 1032045.0 i W Q U oc) 0 F-- # W O W W I— ZJ Q W Ld W J Z J W 0 L LLI I— O U —1 0 O I2:� W W I-- () r-) Q DRAWN: CHECKED: D�I�TE 06 -30 -10 S ,�(L e „a is . .�.,i> •� t l S E2.1 or- JOB U 2M13 i i a