10-818-039ABBREVIATIONS
SYMBOL DESCRIPTION
ABC
ABOVE COUNTER
ACLG
ABOVE FINISHED CEILING
AFF
ABOVE FINISHED FLOOR
AFG
ABOVE FINISHED GRADE
BKR
BREAKER
CB
CIRCUIT BREAKER
CKT
CIRCUIT
CL
CENTER LINE
CLG
CEILING MOUNTED DEVICE
DISC
DISCONNECT
DIV
DIVISION
ECB
ENCLOSED CIRCUIT BREAKER
EX
EXISTING
EXR
EXISTING, RELOCATED
F
FRAME
F/A
FIRE ALARM
FCU
FAN COIL UNIT
FLA
FULL LOAD AMPS
FU
FUSE
G
GROUND
HP
HORSE POWER
K
KILO
c
O
w
U
m
N
0
Ln
v
0
N
frl
O
0
0
N
N
E
P
N
LL]
z
cn
w
0
ABBREVIATIONS
SYMBOL DESCRIPTION
MCB
MAIN CIRCUIT BREAKER
MLO
MAIN LUGS ONLY
NCT
NURSE CALL TERMINAL CABINET
NEC
NATIONAL ELECTRIC CODE
NIC
NOT IN CONTRACT
NL
NIGHT LIGHT
OC
OVER CURRENT
OCP
OVER CURRENT PROTECTION
P
POLE
PH
PHASE
SMH
SPECIAL MOUNTING HEIGHT
TV
TELEVISION
TYP
TYPICAL
UH
UNIT HEATER
UG
UNDER GROUND ELECTRICAL
LION
UNLESS OTHERWISE NOTED
UON
UNINTERRUPTIBLE POWER SUPPLY
V
VOLT(S)
VA
VOLT - AMPS)
W
WATT(S), WIRE, WALL TELEPHONE OUTLET
WP
WEATHERPROOF DEVICE, NEMA 3R
XFMR
TRANSFORMER
LEGEND
SYMBOL DESCRIPTION MOUNTING
HEIGHT
LIGHTING
5
DESIGNATES FIXTURE TYPE - SEE LIGHTING FIXTURE SCHEDULE
NUMBER
O
ALL FIXTURES IN THIS SPACE SHALL BE THE SAME TYPE INDICATED
ELECTRICAL SCHEDULES, LEGENDS AND DRAWING INDEX
F1
DAYBRITE
VIN100112- GG +VINN
NORMAL BRANCH SURFACE OR RECESSED FLUORESCENT
120
SURFACE
I ELEVATOR PIT LIGHT WITH WIRE GUARD
ELECTRICAL
FIXTURE (TYPE DETERMINES MOUNTING)
SERVICE ELEVATOR 48 DEMOLITION & NEW WORK PLAN AT
ROOF LEVEL ELECTRICAL
E2.2
OR EQUIPMENT BRANCH SURFACE OR RECESSED
_
ROOF L_EV_EL. AND PIT ELECTRICAL
®CRITICAL
RECEIVING ELEVATOR #11 DEMOLITION & NEW WORK PLAN AT
FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING)
GROUND LEVEL ELECTRICAL
E2.4
®LIFE-
SAFETY BRANCH SURFACE OR RECESSED FLUORESCENT
E2.5
EMPOLYEE ELEVATOR #3 DEMOLITION & NEW WORK PLAN AT
_
GROUND LEVEL ELECTRICAL
FIXTURE (TYPE DETERMINES MOUNTING)
EMPOLYEE ELEVATORS #1 & 2 DEMOLITION & NEW WORK PLAN
0
NORMAL BRANCH SURFACE OR RECESSED FIXTURE
E2.7
PASSENGER ELEVATOR DEMOLITION & NEW WORK PLAN AT
(TYPE DETERMINES MOUNTING)
GROUND LEVEL ELECTRICAL
E2.8
®
®
CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED FIXTURE
ELECTRICAL
8
E4.0
PARTIAL ONE LINE DIAGRAM
(TYPE DETERMINES MOUNTING)
PARTIAL ONE LINE DIAGRAM
E5.0
®LIFE-
®
SAFETY BRANCH SURFACE OR RECESSED FIXTURE
E5.2
ELECTRICAL STUDIES
E5.3
ELECTRICAL STUDIES
(TYPE DETERMINES MOUNTING)
ELECTRICAL DETAILS
NORMAL BRANCH SURFACE OR SUSPENDED
®
FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING)
CRITICAL OR EQUIPMENT BRANCH SURFACE OR SUSPENDED
®
FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING)
LIFE- SAFETY BRANCH SURFACE OR SUSPENDED FLUORESCENT
®
FIXTURE (TYPE DETERMINES MOUNTING)
C�
NORMAL BRANCH WALL BRACKET FIXTURE
CRITICAL OR EQUIPMENT BRANCH WALL BRACKET FIXTURE
LIFE - SAFETY BRANCH WALL BRACKET FIXTURE
EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED
ON PLANS
BATTERY POWERED EMERGENCY LIGHT
SWITCHES
S
SINGLE POLE SWITCH - IVORY TOGGLE
3' -1011
AFF TO CL
SINGLE POLE SWITCH - RED TOGGLE
, 111 CL
AFF 0
POWER - RECEPTACLES
o
120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE
1' -6"
ABBREVIATIONS FOR EXCEPTIONS)
AFF TO CL
120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT
AS NOTED OR
(REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS)
SEE SPECS
�—
120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT)
AS NOTED OR
SEE SPECS
120V. GFI RECEPTACLE
7AFF
V -6'
TO CL
TELEPHONE /DATA
TELEPHONE OUTLET WITH PLATE
1
AFF 70 CL
FIRE ALARM
,F
FIREFIGHTER'S TELEPHONE JACK
FIRE ALARM VISUAL STATION - LIGHT ONLY
F
FIRE ALARM MANUAL PULL STATION
3' -1011
AFF TO CL
FIRE ALARM CHIME WITH LIGHT
OO
FIRE ALARM SMOKE DETECTOR
CEILING
OH
HEAT DETECTOR
FS
SPRINKLER SYSTEM FLOW SWITCH
Ts
SPRINKLER SYSTEM TAMPER SWITCH
®
FIRE ALARM RELAY
MISCELLANEOUS
NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES)
q=
FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES)
O
JUNCTION BOX
s
PANELBOARD - FLUSH MOUNTED
PANELBOARD - SURFACE MOUNTED
WIRING
CONCEALED CONDUIT
CONDUIT CONCEALED IN FLOOR OR BELOW GRADE
HOMERUN TO PANELBOARD - NUMBER OF CIRCUITS IN MINIMUM 314 CONDUIT
�--�
UNLESS NOTED OTHERWISE
NOTES:
1, ONE NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR,ALTHOUGH NOT
INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED.
2• ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL
BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED.
3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE
CONDUCTORS (ONE PER PHASE) PLUS THREE (3) NEUTRAL CONDUCTORS AND
ONE (D GROUND CONDUCTOR IN EACH CONDUIT.
4, EACH CIRCUIT (PHASE AND NEUTRAL CONDUCTORS) SHALL BE GROUPED TOGETHER
USING CABLE TIES AT THE PANELBOARD AND ALL JUNCTION BOXES, PULL BOXES
AND ALL OTHER LOCATIONS WHERE TERMINATIONS, CONNECTIONS OR SPLICES ARE
MADE.
5. ALL CONDUCTORS SHALL BE #12 AWG UNLESS OTHERWISE NOTED.
ALL WORK SHALL COMPLY WITH THE 2008 EDITION OF THE NEC.
DEMOLITION NOTES
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE EXISTING EQUIPMENT As
REQUIRED TO ACCOMPLISH THE NEW WORK AS SHOWN OR REASONABLY IMPLIED. THE
CONTRACTOR SHALL REFER TO THE NEW ARCHITECTURAL, PLUMBING, FIRE PROTECTION,
MECHANICAL AND ELECTRICAL WORK SHOWN ON THE OTHER DRAWINGS OF THIS SET TO
DETERMINE THE EXTENT OF DEMOLITION REQUIRED.
WHEN REMOVING ELECTRICAL EQUIPMENT AND SYSTEMS, ALL PRECAUTIONS SHELL BE 1 AKEN
TO PREVENT STRUCTURAL DAMAGE TO THE BUILDING. THE CONTRACTOR SHALL COORDINATE
INSTALLATION OF ANY STRUCTURAL SUPPORTS REQUIRED, TEMPORARY OR PERMANENT.
THE CONTRACTOR SHALL EXERCISE CARE SO THAT ONLY THAT CONSTRUCTION INDICATED OR
REASONABLY IMPLIED TO BE REMOVED SHALL BE DEMOLISHED. THE EXI STI NG
CONSTRUCTION TO REMAIN SHALL BE LEFT INTACT AND UNDAMAGED. THE CONTRACTOR
SHALL PROTECT ALL ADJACENT SURFACES AND MATERIALS AS REQUIRED TO PREVENT
DAMAGE.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL, DEMOLI TI ON AND
CONSTRUCTION DEBRIS GENERATED FROM WORK ON ALL FLOORS. TAKING CARE TO PREVENT
EXCESSIVE LOADING OF FLOOR ASSEMBLIES.
THE CONTRACTOR SHALL MAINTAIN CONTINUITY OF CIRCUITS WHERE EXISTING EQUIPMENT IS
TO BE REMOVED AND DOWN STREAM DEVICES MAY BE EFFECTED.
THE CONTRACTOR SHALL COORDINATE ALL POWER INTERRUPTIONS WITH OWNER. SEE
SPECIFICATIONS.
WHEN EXISTING ELEMENTS OF ELECTRICAL EQUIPMENT AND SYSTEMS ARE REMOVED, ALL
REMAINING OPENINGS IN THE SLAB AND WALLS SHALL BE FILLED IN BY THE CONTRACTOR.
REMOVE ALL MISCELLANEOUS FIXTURES AND EQUIPMENT RETAINING ITEMS TO BE IDENTIFIED
FOR SALVAGE AND STORAGE AT THE DIRECTION OF THE OWNER.
THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND
CONSTRUCTION TO MAINTAIN THE INTEGRITY AND OPERATION OF EXISTING LIFE SAFETY AND
EMERGENCY EGRESS EQUIPMENT.
THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND
CONSTRUCTION TO MAINTAIN ACCESS 70 ALL MEANS OF EGRESS CORRIDORS, DOORWAYS AND
STAI RS.
THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND
CONSTRUCTION TO PERMIT EFFECTED AREAS TO CONTINUE TO FUNCTION TO THE GREATEST
EXTENT POSSI BLE. THIS EFFORT SHALL INCLUDE SCHEDULED COORDINATION WITH OWNER OF
ELECTRICAL SHUTDOWNS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL FLUORESCENT AND HID
TYPE LAMPS AND PROPER DISPOSAL OF SAID LAMPS AND SHALL PROVIDE VERIFICATION
OF LAMP DISPOSAL TO THE OWNER UPON REQUEST.
ALL CONDUIT, JUNCTION BOXES AND WIRING DEVICES THAT ARE NOT INTENDED TO RE -USED
MUST BE DEMOLISHED BACK TO THE SOURCE.
THE FIRE ALARM SYSTEM MUST BE MAINTAINED DURING CONSTRUCTION. THE CONTRACTOR MAY
COVER SMOKE DETECTORS WHILE PRESENT BUT MUST LEAVE A FULLY FUNCTIONAL FIRE ALARM
SYSTEM WHEN NOT PRESENT. DURING TIMES WHEN IT IS NOT POSSIBLE TO A FULLY
FUNCTIONAL FIRE ALARM SYSTEM, A FIRE WATCH MUST BE INSTITUTED.
LIGHTING FIXTURE SCHEDULE
TYPE MANUFACTURER CATALOG NO. LAMPS VOLTS MOUNTING RMARKS
GENERAL LIGHTING FIXTURE NOTES:
1. CONTRACTOR MUST QUOTE SPECIFIED LIGHTING FIXTURES AS BASE BID. ANY ALTERNATE LIGHTING
PRODUCTS MUST BE SHOWN AS AN EXCEPTION TO BASE BID, AND MUST BE ACCOMPANIED BY UNIT
PRICES AND TOTAL DOLLAR DEDUCT FROM THE BASE BID.
2. ANY PROPOSED ALTERNATES SHALL MATCH SPECIFIED LIGHTING FIXTURE CHARACTERISTICS AS FOLLOWS:
a. ALL RATINGS INCLUDING, BUT NOT LIMITED TO, WATTAGE, FIRE RATINGS, AND SPECIAL LOCATION
RATINGS SUCH AS DAMP OR WET LABELS, HAZARDOUS LOCATION, CLEAN ROOM, TAMPER PROOF, ETC.
b. PHYSICAL SIZE AND DIMENSION
c. CONSTRUCTION
d. MATERIAL
e. LAMP AND BALLAST TYPE
f. LENS AND REFLECTOR TYPE
g. PAINT APPLICATION PROCESS
h. PHOTOMETRIC CHARACTERISTICS
3. PROVIDE DIMMABLE BALLASTS FOR ANY FIXTURE SHOWN BEING CONTROLLED WITH A DIMMER SWITCH.
DRAWING INDEX
SHEET
0
NUMBER
SHEET TITLE
EO.I
ELECTRICAL SCHEDULES, LEGENDS AND DRAWING INDEX
F1
DAYBRITE
VIN100112- GG +VINN
1 -100W A21
120
SURFACE
I ELEVATOR PIT LIGHT WITH WIRE GUARD
GENERAL LIGHTING FIXTURE NOTES:
1. CONTRACTOR MUST QUOTE SPECIFIED LIGHTING FIXTURES AS BASE BID. ANY ALTERNATE LIGHTING
PRODUCTS MUST BE SHOWN AS AN EXCEPTION TO BASE BID, AND MUST BE ACCOMPANIED BY UNIT
PRICES AND TOTAL DOLLAR DEDUCT FROM THE BASE BID.
2. ANY PROPOSED ALTERNATES SHALL MATCH SPECIFIED LIGHTING FIXTURE CHARACTERISTICS AS FOLLOWS:
a. ALL RATINGS INCLUDING, BUT NOT LIMITED TO, WATTAGE, FIRE RATINGS, AND SPECIAL LOCATION
RATINGS SUCH AS DAMP OR WET LABELS, HAZARDOUS LOCATION, CLEAN ROOM, TAMPER PROOF, ETC.
b. PHYSICAL SIZE AND DIMENSION
c. CONSTRUCTION
d. MATERIAL
e. LAMP AND BALLAST TYPE
f. LENS AND REFLECTOR TYPE
g. PAINT APPLICATION PROCESS
h. PHOTOMETRIC CHARACTERISTICS
3. PROVIDE DIMMABLE BALLASTS FOR ANY FIXTURE SHOWN BEING CONTROLLED WITH A DIMMER SWITCH.
DRAWING INDEX
SHEET
0
NUMBER
SHEET TITLE
EO.I
ELECTRICAL SCHEDULES, LEGENDS AND DRAWING INDEX
E1.0
GROUND FLOOR NEW WORK LOCATION PLAN
E1.1
GROUND FLOOR LOCATION PLAN ELECTRICAL
E1.2
GROUND FLOOR & SECOND FLOOR CONDUIT ROUTING PLAN
ELECTRICAL
E2.1
SERVICE ELEVATOR 48 DEMOLITION & NEW WORK PLAN AT
ROOF LEVEL ELECTRICAL
E2.2
PASSENGER ELEVATORS #9 & 10 DEMOLITION & NEW WORK
_
ROOF L_EV_EL. AND PIT ELECTRICAL
E2.3
RECEIVING ELEVATOR #11 DEMOLITION & NEW WORK PLAN AT
GROUND LEVEL ELECTRICAL
E2.4
RECEIVING ELEVATOR #11 DEMOLITION & NEW WORK PLAN AT
SECOND FLOOR LEVEL ELECTRICAL
E2.5
EMPOLYEE ELEVATOR #3 DEMOLITION & NEW WORK PLAN AT
_
GROUND LEVEL ELECTRICAL
E2.6
EMPOLYEE ELEVATORS #1 & 2 DEMOLITION & NEW WORK PLAN
_
AT GROUND LEVEL ELECTRICAL
E2.7
PASSENGER ELEVATOR DEMOLITION & NEW WORK PLAN AT
GROUND LEVEL ELECTRICAL
E2.8
PARTIAL SEVENTH FLOOR PLAN NEW WORK ELECTRICAL
E2.9
PARTIAL EIGHTH FLOOR MECHANICAL PENTHOUSE NEW WORK
ELECTRICAL
8
E4.0
PARTIAL ONE LINE DIAGRAM
E4.1
PARTIAL ONE LINE DIAGRAM
E5.0
PANEL SCHEDULES
E5.1
PANEL SCHEDULES
E5.2
ELECTRICAL STUDIES
E5.3
ELECTRICAL STUDIES
E6.0
ELECTRICAL DETAILS
REVISIONS:
0
0
0
A
Ln in
�00
in Ln
M 1
Z
�J a
in
QO r°n
0
V= X
Q �a
.a ILL
o cA
z0
Ll =
— co
O
w
Q 1
ryj � N
W 3
I O V) O
�I O M
W () W F-
Lot
1 f-
{A
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
(954) 421 -1260
FAX: (954) 421 -1466
www.ssr-inc.com
Firm Certification - EB-0000857
John E. Moulder PE - 03200
Mlchnel A.8tew 1 PE 6570t
I), 6D_iy YNI -59688
SSIt JOB #F 1032045.0
V7
W
0
W
U
a
z
W
C.�
W
I
J
Q
C�
U
W
J
W
DRAWN:
CHECKED:
9,
{
DATE;
•� p Yl )'1
I
SF-AL
f we
1llo4
,xti °,
ea ,l £y44 d� /i1f 111 Rt iS4'lr >�"
Sheet No.—
E0,1
of
r JOB # 201013
0
QU
�W
a
O Q
Smith
Seckman
Reid, Inc.
1 f-
{A
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
(954) 421 -1260
FAX: (954) 421 -1466
www.ssr-inc.com
Firm Certification - EB-0000857
John E. Moulder PE - 03200
Mlchnel A.8tew 1 PE 6570t
I), 6D_iy YNI -59688
SSIt JOB #F 1032045.0
V7
W
0
W
U
a
z
W
C.�
W
I
J
Q
C�
U
W
J
W
DRAWN:
CHECKED:
9,
{
DATE;
•� p Yl )'1
I
SF-AL
f we
1llo4
,xti °,
ea ,l £y44 d� /i1f 111 Rt iS4'lr >�"
Sheet No.—
E0,1
of
r JOB # 201013