RECEIVING ELEVATOR #11
DEMOLITION PLAN AT UNDERGROUND LEVEE
iii
01 11 21 4' W 12'
DEMOLITION LEGEND
SYMBOL
DESCRIPTION
EXISTING TO REMAIN
e y
EXISTING TO BE REMOVED
- - -�
REMOVE EXISTING TO THIS POINT
--�
GENERAL NOTES:
PLUMBING_
1. CONTRACTOR SHALL PATCH WALLS AND FLOORS TO MATCH EXISTING FINISHES FOR DEMOLITION AND
INSTALLATION OF PIPING, FIXTURES, EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON
ARCH. DRAWINGS.
2. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE
TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL:
A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER.
B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCIBED BY OWNER.
C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT
BY THE OWNER.
D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF
SHUTDOWNS REQUIRED.
3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK,
PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK.
4, ALL UNDERGROUND PIPING SHALL BE BURIED A MINIMUM OF 3' - 0 ".
0
RECEIVING ELEVATOR #11
NEW WORK PLAN AT UNDERGROUND LEVEL - PLUMBING
/TT
111111111 1 0 1
01 11 21 4' 81 12'
NEW CONSTRUCTION LEGEND
SYMBOL
DESCRIPTION
EXISTING TO REMAIN
e y
NEW CONSTRUCTION
- - -�
CONNECT TO EXIST. AT THIS POINT
KEYED NOTES:
O REMOVE AND REPLACE EXISTING SUMP PUMP.
CONNECT TO EXISTING 2" RAIN WATER LEADER WITH NEW 2" STORM LINE
O RECESSED OIL INTECEPTOR. PROVIDE WITH HEAVY DUTY TRAFFIC BEARING LID. SEE DETAIL.
O PROVIDE OIL INTERCEPTOR WITH 2" VENT WITH 2" GOOSENECK AS REQUIRED
tI k
y
" p
1 � c
,, uu
Pik �4d
x;
e y
NORTH Ni 4IN
TOWE� 8W ILDING
RECEIVING
ELEV, u II
PAVILION
VISITORS BUILDING
PARKING
GARAGE
i
LOCATION PLAN
ROOF LEVEL NORTH
y
4
f� REVISIONS -
IA
0
A
0
0
Lr) LO
�CK)
N
M lf7
M
z '
O Q `°
�- 4
LIZ
o�
X
Q � Q
Q W
n
O (n
Z 0
W Z
co
CC _
Q M
F:
O
F—
X
W
� N
0 �o
L1-1 ) V N W
v I
�y
I�Lji W
a
P" PONy
cc
o
O
0
I-
QU
�W
tt
a
O Q
Smith
SR Seckman
Reid, Inc.
600 West Hillsboro, Suite 300
Deerfield Beach, FL 33441
(954) 421 -1260
FAX: (954) 421-1466
www.ssr- inc.com
Firm Certification - EB- 0000857
John E. MoW&r PE - 33200
M!�hnel A, 9tt¢ -,1 PE - 11701
�eo�yn ➢uv;a PE -60688
$$R JOB # 1032045.0