10-818-026c N N a 0 Ln 0 N 0 0 0 N N r� E Q C LL LL z Cr LL a 0 U 0 0 N, N 00 1--. Q 0 PASSENGER ELEVATORS TM9 & 10 NEW WORK PLAN AT ROOF LEVEL 111111111 1 a GENERAL NOTES: 1. CONTRACTOR SHALL PATCH WALLS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING, FIXTURES, EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED, BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 5. PLUMBING VENTS SHALL BE A MINIMUM 25 -FEET FROM ANY AIR INTAKE, DOOR, WINDOW OR OTHER OPENING IN THE BUILDING REROUTE EXISTING VENTS AS REQUIRED. 6. ALL CONDENSATE PIPING SHALL BE SLOPED AT 1 14 / FT UNLESS OTHERWISE NOTED. PLUMBING_ RUN V CD FROM AHU (3 TONS) AND SPILL OVER NEAREST ROOF DRAIN. PROVIDE PIPING WITH SUPPORTS. MIRO INDUSTRIES MODEL # 1.5 ROOF PIPE SUPPORTS. PROVIDE PIPE STRAP AND 1 /11 #8 O STAINLESS STEAL SCREWS TO SECURE PIPE TO SUPPORT. LOCATE SUPPORTS A MAX OF 10 FT ON CENTER.ATTA6H BASE AND FLASH TO ROOF (SEAL WATER TIGHT) WITH MIN. 3 ' EXPANSION BOLTS AT EACH CORNER. VERIFY ATTACHMENT TO ROOF AND FLASHING WITH ARCH. DRAWINGS. LABEL PIPING "CONDENSATE" A MINIMUM OF ONCE EVERY 20 FT. ON CENTER. (TYPICAL) CONSTRUCTION LEGEND DESCRIPTION ffNEW EXISTING TO REMAIN Q NEW CONSTRUCTION CONNECT T O EXIST. AT THIS POINT PASSENGER V. 9 10 NORTH TOWER r r , MAIN BUILDING PAVILION VISITORS BUILDING PARKING. GARAGE LOCATION, PLAN ROOF LEVEL NORTH REVISIONS: A A 0 0 Ln N N M ul M ca z CD 0 Q� < O m �� �X Q Q Q LL- 0 (n zo wT r^V / Q M 1 1, 0 00 C1 0 X T w Q l en I O N O w Ul 7 �1 cn En �i �I O � x A 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 Jolty E. Moulder PE - 33200 Michael A. St—d PE - 66701 Dennis Davie PE - 68688 SSR JOB # 1032045.0 •� # V z V) 12 1— CL w -.I w W � � J CDCLL z 0 0 woo V =L W F- n zQ DRAWN; CHECKED: DATE: 06 -30 -10 1G E C1 rr 1J r No, �i [ Ne 0. I JOB ts 2M13 I 0 Q I— U �W � T C) U3 0 a Q SR Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 Jolty E. Moulder PE - 33200 Michael A. St—d PE - 66701 Dennis Davie PE - 68688 SSR JOB # 1032045.0 •� # V z V) 12 1— CL w -.I w W � � J CDCLL z 0 0 woo V =L W F- n zQ DRAWN; CHECKED: DATE: 06 -30 -10 1G E C1 rr 1J r No, �i [ Ne 0. I JOB ts 2M13 I