10-818-024C U) v i 0 n E o. i O U-) Q- O N (D O 0 cv N Y) F LL LL z U C a. O N N U O O N N co �z 0 PLUMBING NEW CONSTRUCTION NOTES 1. PLUMBING INSTALLATION OF ALL FIXTURES, EQUIPMENT, AND PIPING SHOWN ON THESE DRAWINGS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE, LOCAL AND HEALTH CODES REQUIREMENTS. 2. CONTRACTOR SHALL FIELD VERIFY EXISTING INVERT ELEVATIONS, SIZES AND LOCATIONS OF EXISTING PLUMBING PRIOR TO BIDDING. IF DISCREPANCIES ARE FOOND, THEY ARE TO NOTIFY ENGINEER. 3. ALL PLUMBING FIXTURES TO COMPLY WITH TABLE 604.3 OF THE FLORIDA BUILDING CODE - 2007 4. CONTRACTOR SHALL COORDINATE EQUIPMENT CONNECTIONS & MOUNTING HEIGHTS WITH KITCHEN EQUIPMENT, EQUIPMENT AND ARCHITECTURAL DRAWINGS AND SUPPLIER. INSTALL EQUIPMENT AND MAKE FINAL CONNECTIONS FURNISHING CUTOFF VALVES, P- TRAPS, FITTINGS, P.R.V.'S, AND PIPING AS REQUIRED. CONTRACTOR SHALL OBTAIN A SET OF THE EQUIPMENT DRAWINGS PRIOR TO BIDDING IN ORDER TO DETERMINE ALL REQUIRED CONNECTIONS. 5. ALL NEW VALVES INSTALLED IN DOMESTIC WATER SYSTEMS SHALL BE NSF -61 CERIFIED. 6. PROVIDE 12'X12' ACCESS PANELS FOR ALL VALVES LOCATED ABOVE HARD CEILINGS. INSTALL VALVES SO AS TO BE WITHIN REACH OF ACCESS DOOR. 7. CONTRACTOR SHALL PROVIDE ROUGH -INS AND MAKE FINAL CONNECTIONS FOR EACH PIECE OF EQUIPMENT REQUIRING PLUMBING CONNECTION, INCLUDING TAILPIECES, TRAPS, LINE STRAINERS, STOP VALVES, GAUGES, VACUUM BREAKERS, REDUCING VALVES. SPECIAL FITTINGS, THERMOMETERS, GLOBE SOLENOID VALVES, INSULATION, AND ALL NECESSARY DEVICES FOR A COMPLETE AND OPERATIVE SYSTEM. COORDINATE EXACT REQUIRED PLUMBING ROUGH -INS WITH VENDOR SUPPLIER DRAWINGS. 8. THE CONTRACTOR SHALL INSTALL PLUMBING PIPING IN LOCATIONS INDICATED ON THE CONTRACT DOCUMENTS. THE ONLY DEVIATION FROM THIS WOULD BE IF ADDITIONAL OFFSETS ARE REQUIRED TO COORDINATE WITH OTHER TRADES. IF THE THE CONTRACTOR DESIRES TO CHANGE THE PLUMBING ROUTING FOR ANY OTHER REASON, HE SHALL COMPENSATE THE ENGINEER AT A RATE OF DPE x 2.75 TO REVISE THE PLUMBING DRAWINGS, RISER DIAGRAMS AND FOR THE TIME INVOLVED IN REISSUING DRAWINGS TO THE AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL CONTACT ENGINEER FOR ESTIMATED TIME REQUIRED AND SCHEDULE FOR PERFORMING WORK. 9. PAINT ALL EXPOSED PIPING AT EXTERIOR TO MATCH BUILDING COLOR. 10. EXISTING UTILITIES, WHICH ARE NOT SHOWN, THAT ARE DISCOVERED DURING DEMOLITION SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE BY THE CONTRACTOR FOR PROPER CO- ORDINATION. CONTRACTOR SHALL REMOVE, REWORK AND /OR REROUTE THE EXISTING UTILITIES AS DIRECTED BY THE OWNER'S REPRESENTATIVE. 11. ALL MATERIALS, EQUIPMENT, AND APPARATUS SHALL BE NEW, EXCEPT THAT CALLED FOR AS BEING RE -USED OR FURNISHED BY OTHERS. 12. WITH PENETRATIONS FIR EISTANCERINDEX FOR THROUGH PENETRATION FIRE STOP SYSTEMS. COORDINATE REQUIREMENTS WITH ARCHITECTURAL PLANS AND SPECIFICATIONS. 13. CONTRACTOR SHALL TEST WATER FROM DOMESTIC COLD AND HOT WATER SYSTEMS WHICH HAVE BEEN MODIFIED BY THE RENOVATION AFTER MODIFICATIONS ARE COMPLETE FOR CONTAMINANTS. PROVIDE COPY OF TEST REPORT ONE WEEK PRIOR TO FINAL AHCA INSPECTION. 14. CLEANOUT COVERS SHALL NOT BE INSTALLED ON THE CORRIDOR SIDE OF ANY WALL OR IN ANY CORRIDOR FLOORS. IF DISCREPANCIES ARE FOUND ON PLANS CONTRACTOR SHALL NOTIFY PLUMBING ENGINEER PRIOR TO INSTALLATION. 15. PIPING SHALL NOT BE RUN OVER ANY ELECTRICAL EQUIPMENT, PANELS AND PHONE PANELS. 16. ALL NON PRESSURIZED CONDENSATE PIPING SHALL BE SLOPED AT 1 141 FT UNLESS OTHERWISE NOTED. 17. ALL EXP SEDTEDIPE AND FITTINGS IN FINISHED AREAS SHALL BE 18. THE PLUMBING CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS AS THE JOB PROGRESSES. NO MAJOR CHANGE SHALL BE MADE TO PLUMBING DESIGN ENGINEERING UNLESS IT HAS BEEN COORDINATED, DRAWN AND SUBMITTED FOR APPROVAL. 19, ALL REQUIRED INSURANCES SHALL BE PROVIDED AND MAINTAINED BY THE CONTRACTOR FOR THE PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE, AND OTHER INSURANCES REQUIRED BY THE OWNER, FOR THE DURATION OF THE WORK. 20. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES TO EXISTING PIPING AND FIXTURES DUE TO NEW CONSTRUCTION AND SHALL RESTORE EXISTING WORK DISTURBED TO IT'S ORIGINAL CONDITION AT NO COST TO THE OWNER. 21. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE ROUTING PROBLEMS. 22. PROVIDE OFFSETS AND FITTINGS AS REQUIRED. 23. ALL VENTS SHALL BE A MINIMUM OF 25'-0" AWAY FROM A/C INTAKES, AND OPERABLE WINDOWS. 24. CONTRACTOR SHALL PROVIDE ALL LOW VOLTAGE WIRING AND CONDUIT FOR OIL INTERCEPTOR ALARM PANELS AND SHALL COORDINATE WITH DIVISION 16. CONTRACTOR SHALL HOLD A LOW VOLTAGE WIRING LICENSE. 25. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTS. 26. COORDINATE INSTALLATION OF PLUMBING SYSTEMS WITH ALL CASEWORK. CONTRACTOR SHALL OBTAIN ARCHITECTURAL DRAWINGS AND REVIEW PRIOR TO INSTALLATION. ?7. ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY AND PROPERLY OPERATIVE, AND IN COMPLIANCE WITH APPLICABLE CODES AND GOVERNING AUTHORITIES AND SUBJECT TO ACCEPTANCE BY OWNER /ENGINEER. 28. ALL UNDERGROUND CLEANOUTS SHALL BE HEAVY DUTY TYPE. WITH REINFORCED CONCRETE BASE. 29. CONTRACTOR SHALL GIVE 24 HOURS NOTICE TO APPLICABLE UTILITY COMPANY PRIOR TO PERFORMING WORK INVOLVING UTILITIES. 30. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FROM DRAWINGS. BUT FIT WORK TO ACTUAL CONDITION AND SPACE REQUIREMENTS. 31. THIS CONTRACTOR SHALL BASE HIS PROPOSAL UPON THE EQUIPMENT AS SCHEDULED OR SPECIFIED, USING THE MANUFACTURERS AND MODEL NUMBERS AS CALLED FOR IN THE SPECIFICATIONS AND SCHEDULED ON THE DRAWINGS. IF MORE THAN ONE MANUFACTURER OF EQUIPMENT IS SPECIFIED ANY ONE OF THE MANUFACTURERS OF EQUIPMENT MAY BE USED IN THIS CONTRACTOR'S PROPOSAL. IF THIS CONTRACTOR WISHES TO USE EQUIPMENT NOT SPECIFIED HE MUST, AT THE TIME OF BIDDING, SUBMIT SEPARATELY ON LETTERHEAD STATIONARY OF THE BIDDER THE EQUIPMENT HE WOULD SUBSTITUTE AND THE COST TO BE ADDED bR TO BE DEDUCTED FROM HIS PROPOSAL. 32. THE CONTRACTOR IS EXPECTED TO ORDER ALL MATERIALS IN SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DELIVERIES WILL NOT BE CONSIDERED A JUSTIFIABLE REASON FOR SUBMISSION OF SUBSTITUTE MATERIALS. 33. WARRANTY /GUARANTEE A. THE CONTRACTOR SHALL WARRANTY /GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE YEAR. B. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS, APPEARING DURING THE ABOVE MENTIONED PERIOD, MUST BE IMMEDIATELY REPAIRED BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIR THERETO. 34. Y ES, HEDULED 1. THE DURATION OF EACH SHUTDOWN SHALL BE LIMITED TO NIGHTS AND /OR WEEKENDS WITH THE TIME FRAME FOR SHUTDOWNS AS SPECIFIED BY THE OWNER. THE CONTRACTOR SHALL NOTIFY THE OWNER IN WRITING FORTY -EIGHT (48) HOURS IN ADVANCE OF EACH REQUIRED INTERRUPTION OF EXISTING SERVICE. 2. THE CONTRACTOR SHALL INCLUDE IN BID PRICE ALL PREMIUM TIME CHARGES FOR LABOR AND EQUIPMENT REQUIRED FOR ALL NIGHT AND WEEKEND OVERTIME WORK, AS NECESSARY, TO COMPLETE THE SCOPE OF THE CONTRACT. 35. CONTRACTOR SHALL PROVIDE DRY CONTACTS AND RELAYS ON ALL EQUIPMENT, INTERFACES, MODBUS, SIGNAL WIRING AND CONDUIT FOR CONNECTION INTO BMS (BUILDING MANAGMENT SYSTEM). COORDINATE WITH HOSPITALS CONTROLS VENDOR AND PROVIDE SHOP DRAWINGS OF COMPLETE SYSTEM FOR REVIEW AND APPROVAL. 36. ALL STORM PIPING AND CONDENSATE PIPING SHALL BE INSULATED THROUGHOUT ENTIRE SYSTEM. 37. PROVIDE A MINIMUM OF 6 INCHES BETWEEN ALL PIPING AND FIRE RATED AND SMOKE TIGHT PARTITIONS FOR REQUIRED INSPECTIONS. ANY PIPING WITHIN THIS 6 INCHES SPACE SHALL BE REQUIRED TO BE MOVED AND REROUTED. ANY COST IMPACT TO OTHER TRADES WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 38. INSULATION, FITTINGS COVERS AND ALL FINISHES AND MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50. 39. PROVIDE THE REQUIRED CLEARANCES AND SPACE FOR ALL PLUMBING FIXTURES. PLUMBING CONTRACTOR SHALL VERIFY AND COORDINATE PRIOR TO THE START OF CONSTRUCTION. 40. CONTRACTOR SHALL OBTAIN FROM THE OWNER A COPY OF THE INFECTION CONTROL RISK ASSESSMENT (ICRA) PREPARED FOR THIS PROJECT. CONTRACTOR SHALL REVIEW THE REQUIREMENTS IN THE REPORT AND PERFORM ALL WORK IN ACCORDANCE WITH THOSE REQUIREMENTS. SEE MECHANICAL DRAWINGS FOR COORDINATION OF VENTILATION REQUIREMENTS REQUIRED BY ICRA. PLUMBING DEMOLITION NOTES I. EXISTING SERVICES INDICATED ON THESE DRAWINGS WERE DERIVED FROM EXISTING DRAWINGS AND LIMITED FIELD OBSERVATIONS. THESE DRAWINGS MAY NOT BE ALL INCLUSIVE OF SERVICES THAT EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY SERVICES, LOCATION, TYPE, AND SIZE PRIOR TO ANY CONSTRUCTION. ANY DEVIATIONS IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE ARCHITECT FOR COORDINATION PRIOR TO CONSTRUCTION. 2. EXISTING SERVICES, EQUIPMENT, AND FIXTURES, TO REMAIN OR TO BE RELOCATED, SHALL BE REPAIRED TO ORIGINAL OPERATION OR REPLACED, SHOULD THEY BE DAMAGED DURING CONSTRUCTION. 3. ALL EXISTING WORK NOT SHOWN ON THESE DRAWINGS (UNLESS NOTED OTHERWISE) SHALL REMAIN AS IS. 4. ALL PENETRATIONS OR OPENINGS FROM REMOVED PIPES THROUGH EXISTING BUILDING WALLS AND FLOORS SHALL BE SLEEVED AND /OR PATCHED TO MATCH ORIGINAL. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING PIPING , FIXTURES, IVIED GAS OUTLETS OR EQUIPMENT DUE TO NEW CONSTRUCTION AND SHALL RESTORE EXISTING WORK TO ITS ORIGINAL CONDITION AT NO COST TO THE OWNER. 6. CONTINUITY OF SERVICES: EXISTING BUILDING WILL REMAIN IN USE DURING CONSTRUCTION OPERATIONS. WHEN AN INTERRUPTION OF AN EXISTING SERVICE IS NECESSARY, CONTRACTOR SHALL COORDINATE WITH AUTHORIZED HOSPITAL PERSONNEL BEFORE MAKING THE NECESSARY INTERRUPTION. 7. CONTRACTOR TO FIELD VERIFY THAT ALL EXISTING PLUMBING TO BE REMOVED DOES NOT AFFECT OTHER AREA'S OF THE HOSPITAL THAT ARE NOT IN CONSTRUCTION AND MUST STAY OPERATIONAL. IF DISCREPENCIES ARE FOUND THE CONTRACTOR IS TO NOTIFY THE ENGINEER. 8, CONTRACTOR SHALL REMOVE EXISTING PLUMBING TO FIXTURES, AND EQUIPMENT TO BE REMOVED AS SHOWN ON DRAWINGS OR AS REQUIRED. CONTRACTOR SHALL CAP SERVICES NEXT TO SERVICE MAINS IN CEILINGS, WALLS OR BELOW FLOOR. CONTRACTOR SHALL REROUTE ALL ACTIVE PLUMBING SERVICES IN CHASES OR WALLS TO BE REMOVED, TO NEW CHASE AREAS OR NEW WALLS AS REQUIRED. 9, CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF PLUMBING FIXTURES AND /OR EQUIPMENT THAT ARE TO BE REMOVED TO THE LOCAL OWNER'S REPRESENTATIVE. ALL ITEMS THAT THE LOCAL OWNER'S REPRESENTATIVE WISHES TO RETAIN SHALL BE TURNED OVER TO THE OWNER AND THE REMAINDER SHALL BE REMOVED FROM THE SITE AND LEGALLY DISPOSED. PLUMBING LEGEND C.W SYMBOL DESCRIPTION SYMBOL DESCkiPTl4M - -- COLD WATER HOT WATER BALL VALVE - - -- HOT WATER O10•F) HOT WATER RECIRC CHECK VALVE - - - -- HOT WATER RECIRCULATION P -1,ETC FIXTURE WENTF'CATION -SS- SANITARY SEWER (UNDERGROUND) WASTE (INTERIOR) CONNECTION TO GY1S_ INS CAP ON LINE -- -W- WASTE LINE 3 --V-- VENT PIPE (ABOVE OR BELOW GROUND) S.W. PIPE TURNED UP -RWL- RAIN WATER LEADER 9 PIPE TURNED DOWN - SW- STORM WATER (UNDERGROUND) '5- -GI- BALANCING Vt LYF 1RCUIT SETTER W /CHE( ti VALVE SET RT 0.5G "M C.D. CLEANOUT (ABOVE CEILING) -D- DRIP TROUGH DRAIN LINE ---CD- CONDENSATE DRAIN LINL R.D. PRESSURE REDUCING VALVE . UNDERGROUND COLD WATER F.D. FLOOR DRAIN - _PCD- PUMPED CONDENSATE F.F.EL FINISHED FLOOR ELEVATION PLUMBING ABBREVIATIONS C.W COLD WATER P.R.V. PRESSURE REDUCING VALVE H.W. HOT WATER R.P.B.P. REDUCED PRESSURE BACKFLOW PREVENTER H.W.R. HOT WATER RECIRC A.F.F. ABOVE FINISHED FLOOR V.T.R. VENT THRU ROOF A.F.G. ABOVE FINISHED GRADE W. WASTE (INTERIOR) A.P. ACCESS PANEL R.W.L. RAIN WATER LEADER W.C.O. WALL CLEANOUT S.W. STORM WATER S.S. SANITARY SEWER I.E. INVERT ELEVATION V.I.V. VALVE IN VERTICAL C.O. CLEANOUT C.D. CONDESATE OFCI OWNER FURNISHED CONTRACTOR INSTALLED LE INVERT ELEVATION R.D. ROOF DRAIN F.C.U. FAN COIL UNIT F.D. FLOOR DRAIN F.F.EL FINISHED FLOOR ELEVATION PUMP SCHE _ L SYSTEM TYPE MFGR MODEL G.P.M. HEAD PUMP H.P. VOLTAGE REMARKS No. FTR BOOST SUMP PUMP P -1 SIMPLEX GOULDS 50 EACH I PROVIDE W/ HEAVY DUTY (ELEVATOR PIT) SUBMER. WS0511B 20 I NA /2 HP 115 - IPH FLOAT SWITCH. NOTE *1 NOTES: 1. CSI CONTROLS MODEL: RKSF115CB -X. SIMPLEX CONTROL PANEL, IPH, 25AMPS MAX W /FLOAT SWITCHES CONTACTORS, H.O.A. AND RUN LIGHTS AUDIO- VISUAL HIGH WATER ALARM W /SILENCE, NEMA 4X ENCLOSURE. 2. COORDINATE FINAL LOCATION OF CONTROL PANEL WITH OWNER PRIOR TO INSTALLATION. 3. PROVIDE W /DRY CONTACTS FOR REMOTE MONITORING OF EQUIPMENT TO BMS -- BUILDING MANAGEMENT SYSTEM, COORDINATE FINAL LOCATION OF PANEL WITH OWNER, AND COORDINATE WITH BMS CONTRACTOR. 4. PROVIDE HEAVY DUTY FLOAT SWITCHES AND STAINLESS STEEL MOUNTING BRACKET. 5. PROVIDE CHECK VALVES MOUNTED IN THE HORIZONTAL DISCHARGE. SEE DETAILS P5.1. 6. REFER TO DETAILS ON P5.1 FOR TYPICAL INSTALLATION DETAILS. DRAWING INDEX SHEET NUMBER SHEET TITLE PO.1 PLUMBING LEGENDS, SCHEDULES AND DRAWING INDEX P2.1 SERVICE ELEVATOR #8 MACHINE ROOM = NEW WORK - PLUMBING P2.2 PASSENGER ELEVATOR #9 & 10 MACHINE ROOM - NEW WORK - PLUMBING P2.3 RECEIVING ELEVATOR #11 - DEMOLITION & NEW WORK AT UNDERGROUND LEVEL - PLUMBING P2.4 RECEIVING ELEVATOR #11 SECOND FLOOR PLAN - NEW WORK - PLUMBING P2.5 EMPLOYEE ELEVATOR #3 GROUND LEVEL - DEMOLITION & NEW WORK - PLUMBING P2,6 EMPLOYEE ELEVATORS #1 & 2 GROUND LEVEL - DEMOLITION & NEW WORK - PLUMBING P2.7 PASSENGER ELEVATORS CHILDRENS CENTER GROUND LEVEL - DEMOLITION & NEW WORK - PLUMBING P5.1 PLUMBING DETAILS ♦ ♦ b REVISIONS, 0 A z 0-1 I- Q 0� z0 W= U Q 0 Q W 0 WV) Ln Ln v m M u' co m Ln CD fnn J U^ �a < w r� v v f- x w N � N r-to r_ to 31: Ln V) o� N W W F- E 0 (n c� �W ry r 0 A§ SRSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 John L. Moulder PLC - 33200 IIE6 -1 A. SLe d PE - 65701 De .it D-i. r>; - 68se8 SSR JOB # 1032046 -0 V) W � X ° W W° Uz V) aU r z z� wQ CD LLJ zz m r2 DRAWN: CHECKED: - DATE: 06 -30 -10 SCAL 111 i No. 00 . s 1,091ey No. ON I JOB n 201013 I