10-818-009FIN15H 5CHE[;)UL PARTITION TYPES FLR. WALL 11M CkENEFAL hQ!Ebi: ROOM DOOR I. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE APPROPRIATE�� ROME DETAILS HDW, SET CONSTRUCTION OF ALL WALL TYPES AND COORDINATION OF ALL MECHANICAL, AUTO. DOOR E� I jKj WALL (EXISTING) WTH. ELECTRICAL, PLUMBING AND EXISTING CONDITIONS ADJACENT TO SUCH WALLS. TH. NO. NO. SINCE THE WORK INVOLVES EXISTING BUILDING SYSTEMS AND FACILITIES, TYPE 2 HR FIRE RATED - UL #. M5 MAT. THE CONTRACTOR SHALL GIVE SPECIAL, CONSIDERATION TO EXAMINATION OF NO. EXPOSED COINC.* (A-D.) ANY.EXISTING CONDITIONS THAT WILL PREVENT THE CONSTRUCTION OF SUCH EXPOSED 100 EXISTCW-s MACHINE ROOM RATED WALLS AS PER PLANS. VARIATION OF TYPICAL RATED WALL TYPES H.M. BOTTOM OF FINISH STRUCTURAL DECK 1. -0. DETAILS SHALL BE ANTICIPATED AND SHALL ESE EXPRESSLY INCLUDED AS HM J -1 H -I PART OF THE WORK WHENEVER REQUIRED, AT NO ADDITIONAL COST TO THE * - W- OWNER. A/E WILL SUPPLY THE DIFFERENT DETAILS FOR SUCH WALLS IF EXISTING CAULK SMOKE TIGHT (TOP t BOTTOM) 123 NEEDED. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY (REFER TO ROOM FINISH SCHEDULE RELIEVE HIM OF THE OISLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER S (REFER TO PARTITION THIS CONTRACT. - -- 2. GENERAL CONTRACTOR SHOULD MARK ALL SMOKE WALLS / FIRS WALLS ABOVE THE CEILING - OUTLINE OF SUSPENDED ACOUSTICAL CEILING WHERE APPLICABLE A- WITH PAINT TO READ ACCORDING TO THE WALL RATING AS SUCH: LETTERS MUST BE 1 1/2' FOR FIN15H J'CHEDULE NOTEOJ 1, ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS: ONE HOUR WALLS AND 3' FOR TWO HOUR AND SMOKE WALL$ AS FOLLOWS: 9. ALL EXISTING DOOR FRAMES IN AREAS WHERE NEW WORK IS TO BE DONE, ARE TO RECEIVE EXISTING OR NEW INSUL ATION BOARD NEW PAINT/ STAN AS SELECTED BY ARCHITECTINTERIOR DESIGNER OR OWNER, SMOKE / FIRE WALL (PROTECT ALL PENETRATIONS) 1 1/2' (TYPICAL) 10. EX15TING AREAS TO BE RETAINED. PATCH AND REPAIR / REPLACE AS REQUIRED CONCRETE MASONRY UNIT OR CONCRETE TO MATCH EXISTING ADJACENT FINISH. 3` TWO HOUR FIRE WALL (PROTECT ALL PENETRATIONS) 0 vISQUEEN YAPOR BARRIER IL ALL FINISHES TO MEET OR EXCEED NFPA 253 4 255. O ONE HOUR CORRIDOR WALL (PROTECT ALL PENETRATIONS) 12. ALL PAINT TO MEET OR EXCEED HEALTH SPEC .SHERWIN WILLIAMS, 4. ALL NEW GYPSUM WALLBOARD CEILINGS AND 5OFFIT5 TO BE 5/6' TYPE 'X'. 13. BASE TO MEET OR EXCEED H05PITAL STANDARDS; ONE HOUR SMOKE PARTITION (PROTECT ALL PENETRATIONS) 14, CONTRACTOR TO PROVIDE SHOP DRAWINGS AND /OR SAMPLES TO A/E FOR APPROVAL. 5. PROVIDE WATER- PE515TANT GYPSUM WALLBOARD IN ALL WET AREAS AND FIN15H WITH ENAMEL PAINT. 3. PROVIDE 2' WIDE PAINTED RED LINE AT ALL STORAGE ROOMS, LOCATED 18' BELOW 15. NOT USFD. REFINISHED AND REMODELED AREAS. 16. NOT USED, BOTTOM OF SPRINKLER HEAD /CEILING, WITH 2' HIGH RED LETTERS TO READ 'NO STORAGE w 1 ELEVATOR EXISTING (COLOR SELECTION BY OWNER) ABOVE RED LINE'. ---- 5/V TYPE 'X' STUCCO FINISH 4. PROVIDE PRESSURE TREATED FIRE - RETARDANT PAINTED WOOD SILL NAILER AT PERIMETER VESTIBULE (SEE BUILDING ELEVATION'S) GYPSUM WALLBOARD OF ALL ROOMS WITH WOOD BASE (SEE FINISH SCHEDULES) ON -I /V METAL FURRING 5. ALL PARTITIONS $HALL BE 4' NOMINAL DIMENSION UNLESS OTHERWISE NOTED ON PLANS. V o 16" ON CENTER (WHERE APPLICABLE) 6, INTERIOR WALLS, PERMANENT PARTITIONS (RATED OR NOT) AND TEMPORARY PARTITIONS SHOULD SUPPORT A MINIMUM OF (5) POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR EXISTING CONCRETE WALK- - TO THE WALL. 1 PROVIDE BACKING SUPPORT AT ALL PARTITIONS WHERE EQUIPMENT I$ INDICATED TO BE MOUNTED. NOTES: BASE ($EE FINISH SCHEDULED) S. INSTALL METAL STUDS AT 16' D.C. WITH GYPSUM WALLBOARD HUNG VERTICALLY. T SEALANT 9. GENERAL CONTRACTOR TO VERIFY ANY EXISTING PARTITIONS WITH NEW WALL TYPE DESIGNATIONS FINISH SCHEDULED It 1 AND UP -GRADE AS REQUIRED TO REFLECT NOTED WALL TYPES. 5, ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE DOORS. 10. SUPPORT OF SOFFITS FROM RATED PARTITION 1$ APPROVED, ONLY IF THEY ARE ATTACHED DIRECTLY TO SECTION T NO KNOCK -DOWN FRAMES SHALL BE PERMITTED THROUGHOUT. METAL STUDS AND /OR STRUCTURAL BACKING ONLY. ATTACHMENT TO GYP. WALLBOARD IS NOT ALLOWED. $. ALL '5' LABELED STAIR DOORS TO 5E 450' TEMP, RISE IN 30 MINUTES. II. ALL EXISTING/NEW EXTERIOR MASONRY WALLS TO HAVE SCHEDULE SCHEDULE FINISH ON 5 /8' TYPE 'X' 9. USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED). KNURLED LEVER HANDLES SHALL BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL, AND ELECTRICAL ROOMS. GYPSUM WALLBOARD ON 1 -5/8" METAL STUDS AT 16' O.G. OVER RIGID INSULATION BOARD (TYPICAL AT 1 O ROOM SIDE OF ALL FINISHED ROOM$ ONLY). 12. ALL EXTERIOR MASONRY WALLS TO HAVE ONLY RIGID INSULATION AT ALL UNFINISHED ROOM SIDE$. 13, PROVIDE CONTINUOUS (UNINTERRUPTED BY FURRING:) R -43 (MIN -) RIGID INSULATION BOARD AT ALL EXTERIOR BLOCK/CONCRETE WALLS FACING AIR CONDITIONED SPACES. INSTALL FROM FINISH SLAB TO UNDERSIDE OF STRUCTURAL DECK. GYPSUM WALLBOARD TO CONCEAL INSULATION TO UNDERSIDE OF FINISHED STRUCTURAL DECK. 14. ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE EITHER ROUGH (STUD TO STUD) OR MASONRY (MASONRY (MASONRY TO MASONRY OR MASONRY TO STUD) TYPICAL U.ON 15. IT IS THE INTENT FOR THE RATED BARRIER TO BE BUILT FIRST IN COMPLIANCE WITH THE UL. NO. AS QUOTED. ALL OTHER PARTITIONS ABUTTING RATED PARTITION SHALL NOT BE CONSTRUCTED UNTIL AFTER THE RATED PARTITION IS 100% COMPLETED, 16. IT IS REQUIRED THAT AFTER THE METAL STUD FRAMING IS COMPLETED ON A RATED PARTITION THAT THE COMPANY PROVIDING THE SYSTEM INSPECTS AND CERTIFIES IN WRITING THAT THE FRAMING HAS BEEN PERFORMED IN COMPLIANCE WITH THEIR REQUIREMENTS AND UL. LABEL. SAME CERTIFICATION $HALL BE PROVIDED FOR GYPSUM WALLBOARD INSTALLATION, SCREWING AND TAPING, CONTRACTOR I$ RESPONSIBLE FOR PLACING ELECTRICAL, MEDICAL GAS AND OTHER OUTLETS AND BOXES IN SUCH A FASHION AS TO NOT VIOLATE INTEGRITY OR STC RATING OF PARTITION. IT ALL EXISTING, MASONRY WALLS OR CONCRETE COLUMNS IN AREAS AFFECTED BY NEW RENOVATIONS SHALL RECEIVE SCHEDULED FINISH ON 518' TYPE 'X' GYPSUM WALLBOARD ON "I/8' METAL FURRING STRIPS AT 16' O.C. (TYPICAL UNLESS OTHERWISE NOTED ON PLANS). Ia. BLOCK UP ALL PENETRATIONS THROUGH EXISTING EXTERIOR WALLS DUE TO THE REMOvAL OF EXISTING EQUIPMENT WITH RINKER TYPE T -1S OR T -11A, RE- STUCCO EXTERIOR FACE AND PAINT TO MATCH EXISTING ADJACENT. (SEE MECHANICAL DRAWINGS) � ,4i -TITI i"' G14461If ggtHRjM. 1, A• SMOKE PARTITIONS SHALL BE CONTINUOUS FROM EXTERIOR WALL TO EXTERIOR WALL, AT POINTS OF INTERSECTION WITH OTHER PARTITIONS, THE INTEGRITY OF THE SMOKE WALL MUST BE MAINTAINED AND THE INTERSECTING PARTITIONS BUTTED TO IT, THE SMOKE PARTITION IS ALSO TO BE CONTINUOUS FROM FLOOR SLAB TO'UNDER$IDE OF STRUCTURE (SLAB) ABOVE. B. IN SMOKE AND CORRIDOR PARTITIONS, ALL PENETRATIONS, INCLUDING CONDUITS, A/C DUCTS ETC., MUST BE SEALED TO MAINTAIN THE FIRE RATING INTEGRITY AS REQUIRED BY A.H.C,A AND ALL GOVERNING AUTHORITIES. C. ALL DUCT PENETRATIONS OF SMOKE PARTITIONS AND FIRE RATED PARTITIONS MUST BE DAMPEREP ACCORDING TO THE SPECIFIC FIRE RATING REQUIRED; SMOKE PARTITIONS - COMBINATION S.D./FD. FIRE PARTITIONS -FIRE DAMPER HORIZONTAL EXIT - COMBINATION SDJFD. CORRIDOR WALL -SMOKE DAMPER FLOOR ASSEMBLY OR VERTICAL $HAFT - COMBINATION SD./FD. HAZARDOUS ROOMS - COMBINATION SD-/FD. D. ACCESS DOORS SHALL BE PROVIDED (FIRE RATED WHERE REQUIRED) AND LOCATED IN THE INACCESSIBLE AREAS ADJACENT TO SMOKE AND FIRE PARTITIONS TO ALLOW ALL PARTS OF PARTITIONS TO BE VISUALLY INSPECTED, MAXIMUM SPACING OF PANELS SHALL BE 30'. HIGHEST PRIORITY E. ALL PIPES, CONDUITS AND DUCTS AT ALL SMOKE/FIRE WALL PENETRATIONS SHALL BEE DONE AT W DEGREES ON BOTH SIDES. F. ANY RECESSED ITEM IN THE SMOKE PARTITION OVER 4'X4' MUST BE ENCASED IN A FIVE SIDED 5/8' TYPE 'X' GYPSUM WALLBOARD BOX. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE BACK BOXING FOR ITEMS (EXCEEDING 16 50. W.) RECESSED IN A FIRE PARTITION BACK BOXING $HALL BE OF SUCH CON$TRUCTION AS TO COMPLY WITH FIRE RATING LOWEST PRIORITY REQUIREMENTS FOR THE PARTITION THESE ITEMS INCLUDE, JUNCTION ARE NOT LIMITED TO; ELECTRICAL JUNCTION BOXES MED. GAS OUTLETS, VALVE BORE$ AND ALARM BOXES CwJ' 1,!`� WALL "" I gRlTY LEGEND FIRE EXTINGUISHER CABINETS WATER COOLERS FIRE H05E CABINET$ TELEPHONES FILM ILLUMINATORS ACCESSORIES TWO HOUR FIRE AND SMOKE WALL "" PRIORITY I HIGHEST TWO HOUR FIRE WALL PRIORITY 2 TWO HOUR SHAFT WALL ONE HOUR FIRE AND SMOKE WALL PRIORITY 3 ONE HOUR FIRE WALL PRIORITY 4 NON RATED WALL PRIORITY 5 LOWEST N -QT . 1. SCHEDULE CONSTRUCTION OF WALLS ACCORDING TO PRIORITY, 2, ALL PRIORITY I THRU 4 WALLS SHOULD BE FRAMED WITH ONE SIDE DRYWALLED AT THE 40% CONSTRUCTION SURVEY. 3. BOTH SIDES OF PRIORITY I THRI 4 WALLS SHALL BE SEALED AND STENCILED AT THE 80%& CONSTRUCTION SURVEY. FIN15H 5CHE[;)UL D00 &CHEDUL ROOM FLR. DOOR ROOM DOOR DOOR BOOR 512E ROME DETAILS HDW, SET LA13EL AUTO. DOOR REMARKS WTH. HGT. TH. NO. NO. NAME TYPE MAT- MAT. JAMS HEAD SILL NO. EXPOSED COINC.* (A-D.) - EXPOSED 100 EXISTCW-s MACHINE ROOM A H.M. 3' -0. 1. -0. 1 -3/4' HM J -1 H -I EXISTYao * - W- 7K SEE NOTE 10 W1 DOOR CLOSER EXISTING 123 ROOM NUMBER SYMBOL (REFER TO ROOM FINISH SCHEDULE PARTITION TYPE$ SYMBOL S (REFER TO PARTITION TYPE DETAILS AND NOTES) - -- - (UNHATCHED DENOTES EXISTING) - SECTION 5YM50L A- W/ DRAWING AND 5HEIET NUME3ER5 FIN15H J'CHEDULE NOTEOJ 1, ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS: ALL INTERIOR FINISHES SHALL BE CLASS 'A' WITH FLAME SPREAD 0 -25 AND SMOKE DEVELOPED 0 -450, 9. ALL EXISTING DOOR FRAMES IN AREAS WHERE NEW WORK IS TO BE DONE, ARE TO RECEIVE ALL FLOOR FINISH IN CORRIDORS AND EXITS SHALL BE CLASS 'I' MINIMUM 0:45 WATTS PER $a CM. NEW PAINT/ STAN AS SELECTED BY ARCHITECTINTERIOR DESIGNER OR OWNER, EXCEPTIONS: CLASS '5' INTERIOR FINISH WITH FLAME SPREAD 26 -15 AND SMOKE DEVELOPED 0 -450 10. EX15TING AREAS TO BE RETAINED. PATCH AND REPAIR / REPLACE AS REQUIRED MAY BE USED IN SMALL INDIVIDUAL ROOMS OF NOT OVER FOUR PERSONS CAPACITY, OTHER THAN TO MATCH EXISTING ADJACENT FINISH. EXITS AND ACCESS TO CORRIDOR EXITS, 0 2, ALL WALLS a CEILING FINISHES TO BE GLASS 'A' FINISH (0 -25) FLAME. IL ALL FINISHES TO MEET OR EXCEED NFPA 253 4 255. 3, INTERIOR FINISH IN CORRIDORS SHALL BE CLASS 'I'. 12. ALL PAINT TO MEET OR EXCEED HEALTH SPEC .SHERWIN WILLIAMS, 4. ALL NEW GYPSUM WALLBOARD CEILINGS AND 5OFFIT5 TO BE 5/6' TYPE 'X'. 13. BASE TO MEET OR EXCEED H05PITAL STANDARDS; REMAIN. (SEE ENGINEERING DWG'5) 14, CONTRACTOR TO PROVIDE SHOP DRAWINGS AND /OR SAMPLES TO A/E FOR APPROVAL. 5. PROVIDE WATER- PE515TANT GYPSUM WALLBOARD IN ALL WET AREAS AND FIN15H WITH ENAMEL PAINT. 6. CONTRACTOR TO REPAIR, PATCH, AND REPAINT ALL DAMAGED FINISHES AS REQUESTED IN ALL EXISTING 15. NOT USFD. REFINISHED AND REMODELED AREAS. 16. NOT USED, 1. ALL EXTERIOR PATCH UP WORK TO BE REPAIRED AND RESTORED TO MATCH EXISTING FINISHES AND COLORS. w 1 ELEVATOR EXISTING (COLOR SELECTION BY OWNER) 8. ALL INTERIOR WALL SURFACES WITHIN EXIT STAIRS TO BE PAINTED CEMENT PLASTER FINISH. * ELEVATOR VESTIBULE EXISTING CONC. MASONRY WALL V SH EXISTING CONCRETE WALK- - LU t- X NOTES: L DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 10 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO CLOSE TO A POINT OF 3 INCHES FROM THE LATCH, 2. THE MAXIMUM FORCE FOR PU5HING OR PULLING AN INTERIOR HINGED DOOR SHALL BE: 5 LBF T 3, FOR TYPICAL DOOR AND FRAME DETAILS SEE SHEET A -11 X 4. GROUT ALL METAL HOLLOW FRAMES IN CONCRETE BLOCK AND/OR POURED CONCRETE. It 1 5, ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE DOORS. 6. PROVIDE SMOKE TIGHT CAULKING AROUND THE ENTIRE PERIMETER OF DOORS. T NO KNOCK -DOWN FRAMES SHALL BE PERMITTED THROUGHOUT. $. ALL '5' LABELED STAIR DOORS TO 5E 450' TEMP, RISE IN 30 MINUTES. 9. USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED). KNURLED LEVER HANDLES SHALL BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL, AND ELECTRICAL ROOMS. �c 10. NEW HARDWARE SHALL MATCH EXISTING SOUTH MIAMI HOSPITAL SPECIFICATION STANDARDS AND SHALL INCLUDE WEATHERSTRIPPING. FIN15H 5CHE[;)UL LR ROOM / e 1. WALL OR PARTITION WITH WAINSCOT CEILING 0 1 NO. ROOM NAME: FLOOR SASE WALLS REMAiRKS - MAT. _- HCxT. MAT. HGT. Q j 100 E�CISTW. MACHI1� P00M C,ow- NOW EXPOSED COINC.* - - EXPOSED '-O' 7�c ALL EiXISTW. PARTITION TO REMAIN � - (COORDINATE W/ DOOR SCHEDULE „ 1 NOTE: BROKEN LINE DOOR INDICATES W- DOUBLE: ACTING DOOR EXISTING 123 ROOM NUMBER SYMBOL (REFER TO ROOM FINISH SCHEDULE PARTITION TYPE$ SYMBOL S (REFER TO PARTITION TYPE DETAILS AND NOTES) - -- - (UNHATCHED DENOTES EXISTING) - SECTION 5YM50L A- W/ DRAWING AND 5HEIET NUME3ER5 FIN15H J'CHEDULE NOTEOJ 1, ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS: ALL INTERIOR FINISHES SHALL BE CLASS 'A' WITH FLAME SPREAD 0 -25 AND SMOKE DEVELOPED 0 -450, 9. ALL EXISTING DOOR FRAMES IN AREAS WHERE NEW WORK IS TO BE DONE, ARE TO RECEIVE ALL FLOOR FINISH IN CORRIDORS AND EXITS SHALL BE CLASS 'I' MINIMUM 0:45 WATTS PER $a CM. NEW PAINT/ STAN AS SELECTED BY ARCHITECTINTERIOR DESIGNER OR OWNER, EXCEPTIONS: CLASS '5' INTERIOR FINISH WITH FLAME SPREAD 26 -15 AND SMOKE DEVELOPED 0 -450 10. EX15TING AREAS TO BE RETAINED. PATCH AND REPAIR / REPLACE AS REQUIRED MAY BE USED IN SMALL INDIVIDUAL ROOMS OF NOT OVER FOUR PERSONS CAPACITY, OTHER THAN TO MATCH EXISTING ADJACENT FINISH. EXITS AND ACCESS TO CORRIDOR EXITS, 2, ALL WALLS a CEILING FINISHES TO BE GLASS 'A' FINISH (0 -25) FLAME. IL ALL FINISHES TO MEET OR EXCEED NFPA 253 4 255. 3, INTERIOR FINISH IN CORRIDORS SHALL BE CLASS 'I'. 12. ALL PAINT TO MEET OR EXCEED HEALTH SPEC .SHERWIN WILLIAMS, 4. ALL NEW GYPSUM WALLBOARD CEILINGS AND 5OFFIT5 TO BE 5/6' TYPE 'X'. 13. BASE TO MEET OR EXCEED H05PITAL STANDARDS; REMAIN. (SEE ENGINEERING DWG'5) 14, CONTRACTOR TO PROVIDE SHOP DRAWINGS AND /OR SAMPLES TO A/E FOR APPROVAL. 5. PROVIDE WATER- PE515TANT GYPSUM WALLBOARD IN ALL WET AREAS AND FIN15H WITH ENAMEL PAINT. 6. CONTRACTOR TO REPAIR, PATCH, AND REPAINT ALL DAMAGED FINISHES AS REQUESTED IN ALL EXISTING 15. NOT USFD. REFINISHED AND REMODELED AREAS. 16. NOT USED, 1. ALL EXTERIOR PATCH UP WORK TO BE REPAIRED AND RESTORED TO MATCH EXISTING FINISHES AND COLORS. iK 11. EXPOSED FLOOR, WALLS, AND CEILINGS SHALL BE PAINTED WITH FLAT FINISH PAINT 1 ELEVATOR EXISTING (COLOR SELECTION BY OWNER) 8. ALL INTERIOR WALL SURFACES WITHIN EXIT STAIRS TO BE PAINTED CEMENT PLASTER FINISH. MASONRY LOW WALL CTYPJ EXISTING EXTERIOR WALK - EXISTING: ELECTRICAL ROOM �J .. EXISTING WALL OR / e 1. WALL OR PARTITION WITH m I I I f 0 1 y'--__ -- -EXISTING D Et -I'OL. I T I ON. NOTES: MACHINE REPLACE WITH NEW. ROOM EXISTING REMOVE EXISTING METAL LOUVER - 51-OCK AND PATCH EXISTING WINDOW OPENING TO MATCH EXISTING. ELEVATOR lID0 EQUIPMENT ® UP w (SEE EL.00R ELANSL LOCATION EXISTING WALL OR GROUND LEVEL _ _ NItN PARTITION TO REMAIN � - (COORDINATE W/ DOOR SCHEDULE „ 1 NOTE: BROKEN LINE DOOR INDICATES DOUBLE: ACTING DOOR EXISTING 123 ROOM NUMBER SYMBOL (REFER TO ROOM FINISH SCHEDULE PARTITION TYPE$ SYMBOL S (REFER TO PARTITION TYPE DETAILS AND NOTES) STAIRWELL (UNHATCHED DENOTES EXISTING) 1 SECTION 5YM50L A- W/ DRAWING AND 5HEIET NUME3ER5 DETAIL 5YM50L W/ DRAWING AND SHEET NUMBERS IC REVISION SYMBOL (REFER TO COVER SHEET I ki OUT OF SCOPE NOTES. 1. NOT ALL 5YME3OL5 ARE APPLICAPLE 2, ALL EXISTING ELECTRICAL OUTLETS TO REMAIN. (SEE ENGINEERING DWG'5) I -t -I I -I -I I -I -I I--I -1 I -I -I EXISTING 1 ELEVATOR EXISTING * ELEVATOR VESTIBULE EXISTING CONC. MASONRY WALL FL I SH EXISTING CONCRETE WALK- - LU t- X uj T X EXISTING It 1 PARKING STALL --,--. EXISTING: ELECTRICAL ROOM �J .. EXISTING WALL OR / e 1. WALL OR PARTITION WITH m I I I f 0 1 y'--__ -- -EXISTING D Et -I'OL. I T I ON. NOTES: MACHINE REPLACE WITH NEW. ROOM EXISTING REMOVE EXISTING METAL LOUVER - 51-OCK AND PATCH EXISTING WINDOW OPENING TO MATCH EXISTING. ELEVATOR lID0 EQUIPMENT ® COLUMN OR CONCRETE WALL w (SEE EL.00R ELANSL L L EXISTINGa COVERED PARKING GARAGE W/ EXPOSED CONC. DRIVEWAY CTYPJ Et'*1 FL.O'''EE ELEV ATOF�,' #. 3 DEMOLITION FLAN AT GfROUNI) LEVEL SCALE: 1/4' a I' -0' NOTE: SEE ME.P, DRAWINGS FOR ADDITIONAL SCOPE OF WORK OF REQUIRED DEMOLITION EMf=L 0)- EE EL EVATOF, #. 3 FAfRTIAL. EOUIFMENT FLAN AT GROUND LEVEL SCALE: 1/4' - 1' -0' NOTE5: 1, SEE M.E.P. DRAWINGS FOR SCOPE OF WORK OF 'NEW UPGRADES °. 2. EXISTING EQUIPMENT LAYOUT AS SHOWN I$ FOR REFERENCE ONLY. THE NEW EQUIPMENT LAYOUT AND EQUIPMENT PROFILE SHALL BE SIMILAR, 3. ELEVATOR EQUIPMENT SUPPLIER SHALL 5U5MIT NEW EQUIPMENT LAYOUT ALONG WITH SHOP DRAWINGS FOR ARCHITECT'5 REVIEW AND APPROVAL. NkW UNDERCaROUNp PRIH -FAB OIL INTERCEPTOR U1/ HEAVY DUTY (ANTI -SKID) TRAFFIC LID- SEE M.E.P. DMS_ AND SPECS FOR DETAILS "'-�-- EXISTING PARKING $TALL - NEW STEEL BOLLARD - SEE DETAIL 'H' ON SHEET A -11 Et-I 'L.O`rEE ELEVATOi;;,;> #: 3 F,4fRTIAL FL00F� FLAN AT C;f;P,0UN SCALE: 1 /4' = 1' -0' I I m I I m I I TOR *e m I I m EXISTING COVERED PARKING GARAGE 7 gh EXPOSED CEILING EXIST'G FIN. EL- + S' -O' SMOKE: DETECT NEW HEAT (TYR) DETECTOR ' TYP.) A H S EXISTING MACHINE ROOM 1IDID _ 1 XIST'G LIGHT FIXTURES CTYPJ_ &1117 ® 'I EMF'LO`' EE ELEV;4TOF� #. 3 PARTIAL REFLECTED CEILING FLAN AT GROUND 1. EYE SCALE: 1/4' = 1' -0' q{ { �' � , 11 0,KTt NOTES: 1. EXISTING CEILING IS EXPOSED CONCRETE. CLEAN AND PAINT AS REQUIRED (COL�OR� � SELECTION DY OWNER) �,�U; °(UT�J` 2. EXISTING CEILING MOUNTED I" X 4' FLUORESCENT LIGHT FIXTURES SHALL REMAIN - SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ED yap_ .. EXISTING WALL OR ELEV. #' 3 e 1. WALL OR PARTITION WITH m I I I f 0 1 y'--__ -- (SEE DEMOLITION LEGENP) D Et -I'OL. I T I ON. NOTES: OREMOVE EXISTING DOOR AND FRAME - REPLACE WITH NEW. /;� REMOVE EX15TING EXHAUST FAN - SEE MEP �% DRAWING& FOR ADDITIONAL INFORMATION. REMOVE EXISTING METAL LOUVER - 51-OCK AND PATCH EXISTING WINDOW OPENING TO MATCH EXISTING. REMOVE AND REPLACE EXISTING SUMP PUMP - SEE M.E.P. DWGS. FOR DETAILS. - EXISTING REINFORCED CONC. ® COLUMN OR CONCRETE WALL w (SEE EL.00R ELANSL LOCATION EXISTING WALL OR GROUND LEVEL _ _ NItN PARTITION TO REMAIN � WITH NEW DOOR AND DOOR NUMf3E (COORDINATE W/ DOOR SCHEDULE „ 1 NOTE: BROKEN LINE DOOR INDICATES DOUBLE: ACTING DOOR u 123 ROOM NUMBER SYMBOL (REFER TO ROOM FINISH SCHEDULE PARTITION TYPE$ SYMBOL S (REFER TO PARTITION TYPE DETAILS AND NOTES) ELEVATION MARKS (HATCHING DENOTES NEW) (UNHATCHED DENOTES EXISTING) 1 SECTION 5YM50L A- W/ DRAWING AND 5HEIET NUME3ER5 DETAIL 5YM50L W/ DRAWING AND SHEET NUMBERS IC REVISION SYMBOL (REFER TO COVER SHEET � FOR REVISION INFORMATION) EMF'LO`' EE ELEV;4TOF� #. 3 PARTIAL REFLECTED CEILING FLAN AT GROUND 1. EYE SCALE: 1/4' = 1' -0' q{ { �' � , 11 0,KTt NOTES: 1. EXISTING CEILING IS EXPOSED CONCRETE. CLEAN AND PAINT AS REQUIRED (COL�OR� � SELECTION DY OWNER) �,�U; °(UT�J` 2. EXISTING CEILING MOUNTED I" X 4' FLUORESCENT LIGHT FIXTURES SHALL REMAIN - SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. ED yap_ DEMOLITION FLAN LEry EN[ ) .. EXISTING WALL OR ELEV. #' 3 e z WALL OR PARTITION WITH m I I I f 0 DEMOLITION $YM130L. y'--__ -- (SEE DEMOLITION LEGENP) D Et -I'OL. I T I ON. NOTES: DEMOLITION FLAN LEry EN[ ) - -' --- -- -- EXISTING WALL OR ELEV. #' 3 PARTITION TO BE REEMOVED z WALL OR PARTITION WITH m I I I EXISTING DOOR TO BE REwM:7YEp EA tPLO E'S DEMOLITION $YM130L. l i / (SEE DEMOLITION LEGENP) D Et -I'OL. I T I ON. NOTES: OREMOVE EXISTING DOOR AND FRAME - REPLACE WITH NEW. /;� REMOVE EX15TING EXHAUST FAN - SEE MEP �% DRAWING& FOR ADDITIONAL INFORMATION. REMOVE EXISTING METAL LOUVER - 51-OCK AND PATCH EXISTING WINDOW OPENING TO MATCH EXISTING. REMOVE AND REPLACE EXISTING SUMP PUMP - SEE M.E.P. DWGS. FOR DETAILS. FLOOR FLAN LEGENF,) m iiiiiiiw WALL OR PARTITION ELEV. #' 3 (61HE PARTITION TYPES)_ z ONE HOUR FIRE /SMOKE RATED m I I I WALL OR PARTITION EA tPLO E'S (SE TYPES) ARKIN TWO HOUR FIRE: /SMOKE RATED ARAGE ' WALL OR PARTITION 0 (SEE PARTTION TYPES) w NEW METAL STUD PARTITION (SEE FLOOR PLANS AND (PARTfTIQN TYPE TA( S) 11.1 aA,.A - EXISTING REINFORCED CONC. ® COLUMN OR CONCRETE WALL w (SEE EL.00R ELANSL LOCATION EXISTING WALL OR GROUND LEVEL _ _ NItN PARTITION TO REMAIN � WALL OR PARTITION WITH NEW DOOR AND DOOR NUMf3E (COORDINATE W/ DOOR SCHEDULE „ 1 NOTE: BROKEN LINE DOOR INDICATES DOUBLE: ACTING DOOR u 123 ROOM NUMBER SYMBOL (REFER TO ROOM FINISH SCHEDULE PARTITION TYPE$ SYMBOL S (REFER TO PARTITION TYPE DETAILS AND NOTES) ELEVATION MARKS (HATCHING DENOTES NEW) (UNHATCHED DENOTES EXISTING) 1 SECTION 5YM50L A- W/ DRAWING AND 5HEIET NUME3ER5 1 DETAIL 5YM50L A_ W/ DRAWING AND SHEET NUMBERS REVISION SYMBOL (REFER TO COVER SHEET � FOR REVISION INFORMATION) OUT OF SCOPE NOTES. 1. NOT ALL 5YME3OL5 ARE APPLICAPLE 2, ALL EXISTING ELECTRICAL OUTLETS TO REMAIN. (SEE ENGINEERING DWG'5) f New wow No-rEs /';1 INSTALL NEW WALL MOUNTED A/C UNIT ABOVE D EXISTING DOOR - SEE MEP DWC;5, FOR DETAILS, 5LOCK AND PATCH EXISTING LOUVER OPENING PER DETAIL 'I=' ON SHEET A -11 OEX15TING I5" piA EXHAUST FAN OPENING SHALL 5E BLOCKED AND PATCHED W/ (4) # 5 STEEL DOWELS SET AT 12'0,C. IN EACH DIRECTION PLACED IN 5/S" X 4" HOLES FILLED W/ EPDXY GROUT THEN FILL W/ SOLID CONCRETE AND FIN15H W/ STUCCO TO MATCH EX15TING EXTERIOR FINISH. NEW CONDENSING UNIT SECURED TO NEW CONC. �J PAD W/ (2) HURRICANE METAL STRAPS AT (o' FROM EACH END - 5EE DETAIL "A' ON SHEET A -11 (SIMILAR) NEW 4' CONC. PAD - 5EE DETAIL 'G° ON SHEET A -11 (VERIFY SIZE OF A/C UNIT) U rl ul O (d I EMPLOYEE 0 ELEV. #' 3 PAVILION z BUILDING EA tPLO E'S ARKIN I� ARAGE ' 0 0 w i�AG 11.1 aA,.A EDUCATION CENTER w ® LOCATION FLAN GROUND LEVEL _ _ NItN U rl ul O (d I DE Vft I.P. CHECKED: L.EN. DATE: 06 -30 -10 AS 0 z I� O 0 0 w i�AG 11.1 aA,.A T w ® Z 4� � ® W c DE Vft I.P. CHECKED: L.EN. DATE: 06 -30 -10 AS