10-818-007EXISTING CONCRETE MASONRY PARAPET WALL OPEN -7 NEW PRE -FA15 GALV. STEEL COVER W/ INSULATION OVER EXISTING METAL EQUIPMENT CURS - SHALL MEET THE REQUIREMENTS FOR HURRICANE PROTECTION PER F.B.C. 15222 II i( I I I mml OUTLINE OF EXISTING - - I I ELEVATOR SHAFT I I 1 I I 1 1 BELOW (TYP.) I I ' -0,1 1 1 LL - - -- \ f = —� NEW GALV. STEEL STAND - SEE DETAILS 'A', 'e', 'C' E 'D' ON SHEET A -II EXISTING MEMBRANE ROOFING (TYP.) AN AT SECOND FLOOR I \I OUTLINE OF EXISTING MACHINE ROOM 5ELOW (TYP.) I I SCALE: 1/4' a 1' -0' NOTE. *VERIFY SIZE OF NEW STAND W/ HVAC EQUIPMENT SPECS - CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ARCHITECT'S REVIEW AND APPROVAL. EXISTING CONC. MASONRY LOW WALL TO REMAIN (TYP.) EXISTING CONCRETE WALK (TYP.) ---- \ RECEIVING ELEVATOR #: 11 FzL F =VATOfi�' PIT DEMOL.ITI� SCALE: 1/4' = 1'-0' EX15TING SUMP PUMP W/ METAL GRATING TO BE REMOVED �C AN EXISTING CONC. MASONRY WALL (TYPICAL) NOTE. * 5EE M.E.P. DRAWINGS FOR ADDITIONAL SCOPE OF WORK OF REQUIRED DEMOLITION NEW UNDERGROUND PRE -FAB OIL INTERCEPTOR W/ HEAVY DUTY (NON -SKID) TRAFFIC LID - SEE M.E.P. DWG5. AND SPECS FOR DETAILS EX15TING CONIC. MA50NRY LOU) WALL - tu - - FLUSH NEW SUMP PUMP - SEE — — M.E.P. DRAWINGS AND L _ ° SPECS FOR ADDITIONAL in INFO. (TYP.) WALL MOUNTED HEAT DETECTO o O o (TYP.) EX15TINC -c :D ELEVATOR 'N it = I I m III m I I m FREG IVING� ELEVATOR #: 11 ELEVATOR PIT FLOOR FLAN V% MIA01 jvvRON f OUTLINE OF SECOND FLOOR A50VE REMOVE EXISTING SIDE WALL MOUNTED FIRE SPRINKLER HEAD AND REPLACE W/ NEW 1 4'i2' MIN. FOR TOE SPACE SCALE. 1/4' - 1' -0' NOTE: SEE M.E.P. DRAWINGS FOR ADDITIONAL NEW WORK REQUIRED IN THIS SPACE, RECEIVING DOCK DEMOLITION FLAN LF�P' r C) — ---- -- — EXISTING WALL OR UILDING PARTITION TO BE REMOVED RECEIVING WALL OR PARTITION WITH ' r i EXISTING DOOR TO BE REMGVED z P-" DEMOLITION 5YMBOL PAVILION (SEE DEMOLITION LE -- -END) 77 t-IOL_ I T (ON NOTES: 1 REMOVE EXISTING METAL ACCESS LADDER - PATCH AND REPAIR AS REQUIRED. REMOVE EXISTING SUMP PUMP AND REPLACE WITH NEW. FLOOR FLAN L- (aEN1:) MAIN ONE HOUR FIRF RATE7_ WALL OR PARTITION UILDING (SEE PARTITION TYPES) RECEIVING ONE HOUR FIRE /SMOKE RATED r i WALL OR PARTITION z P-" (SEE PARTITION TYPES) PAVILION TWO HOUR FIRE / 5MOKE RATED BUILDING WALL OR PARTITION (SEE PARTTION TYPES) � O NEW METAL 5TUD PARTITION (SEE FLOOR PLANS AND (PARTITION TYP DETAILS) PLAN GROUND LEVEL NOMlf!! EXISTING REINFORCED CONC. w COLUMN OR CONCRETE WALL (SF,E FLOOR PLANS) EXISTING WALL OR PARTITION TO REMAIN WALL OR PARTITION WITH NEW DOOR AND DOOR NUMIBF (COORDINATE W/ DOOR SCHEDULE ii NOTE- BROKEN LINE DOOR INDICATE n DOUBLE ACTING DOOR WALL OR PARTITION WITH EX15TING DOOR TO REMAIN 1 34 ROOM NUM15ER SYMBOL (REFER TO ROOM FINISH SCHEDULE PARTITION TYPES SYMBOL 8 (REFER TO PARTITION TYPE DETAILS AND NOTES) ` ELEVATION MARKS (HATCHING DENOTES NEW) (UNHATCHED DENOTES EXISTING) 1 SECTION SYMBOL A- W/ DRAWING AND SHEET NUMBERS I DETAIL 5YMC30L A- W/ DRAWING AND SHEET NUMBERS REVISION SYMBOL (REFER TO COVER SHEET 3 FOR REVISION INFORMATION) OUT OF SCOPE NOTES: I• NOT ALL SYMBOLS ARE APPLICABLE 2. ALL EXISTING ELECTRICAL OUTLETS TO REMAIN. (51HE ENGINEERING DWG's) �h '+ "9 b ' ray 17 ,� �� 3.�; r�.� ` `y ,° C)r J�JJ. i rl [ d� w is ``J soy- it MIMM ANG DEPT- T�ijrTIJFIAL SECTION ',,.PROVED gY:.. NORTH MAIN TOWER UILDING RECEIVING \ ELEV. 11 r F� z P-" O PAVILION VISITOR'S BUILDING PARKING GARAGE � O LOCATION PLAN GROUND LEVEL NOMlf!! t A A IA_ z1 o< , >O ax z W " 04 M/ O < Enl W 0 1 Pon" el • Pw�.l IC) F�1 0 16 0 V) 1 "V a O Rf R bRAWK 1'1- (RECKM L.E.N. DATL 06-30 -10 SCALEs AS SNOWN \} sf f Sheet No. A -5 OF 15 JOB # 201013 Z Ra" 0 Z O O F� z P-" O A z < Z MGM >I I�1 W � O , O w bRAWK 1'1- (RECKM L.E.N. DATL 06-30 -10 SCALEs AS SNOWN \} sf f Sheet No. A -5 OF 15 JOB # 201013