10-818-001Affiliate of Baptist Health S L- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENT TO Be PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER, 2,- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS, CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL, THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON- TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE RE -DONF. 4.- SHUTDOWN OF UTILITIES= IF A SHUTDOWN OR ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAC TOP MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL, CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6,- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMETS UP DURING THE CONSTRUCTiON,IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7,- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8,- THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC TION CONTRACT, 9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. II,- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL. 12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. 13,- CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NON - CONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION, 14.- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15,- DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME. 16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17,- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA, CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS A$ REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING, I8.- ELEVATION AND LEVELS: A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB, UNLESS NOTED OTHERWISE. i9,- ALL INTERIOR GYPSUM WALL BOARD IS 5/8" TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W,B. 20.- PROVIDE WATER RESISTANT TYPE X G.W.B, IN ALL TOILETS. AND JANITOR'S CLOSETS, 21.- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22.- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK. 23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES, THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO INSTALLATION. 24,- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS: A. ELECTRIC CLOSETS C, MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26.- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL. 27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH, 28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES, 29,- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS EA, SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2' -0 UNLESS OTHERWISE NOTED, 30. CONTRACTOR. SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE- MENTS, CONTRACTORSPALL PROVIDE ALL NECESSARY INSULA- TION /FIRE PROTECTIVE COATINGS, 31, THE DEPARTMENT FOR APPROVAL (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. of South Fl ELEVATORS RENOVATION SOLiTH dViIAMI HOSPITAL 6200 SW 73RD ST MIAMI ,FL. 33145 TEL: (786) 662 - 4659 FAX: (305) 662 - 4653 AHCA STAGE III - PROJECT ID #: 158 -001 JUNE 309 2010 (INTERIOR REMODELING ONLY) rn ,' � td F%Aq"� I =03 DIAMETER I DIAL 4 AND � DMENSION r j SCI Ise 1ENGTH 1�1� DN LAM LAMINATE F%Aq"� I =03 DIA DIAMETER I DIAL 4 AND DM DMENSION L ANGLE L 1ENGTH ® AT DN LAM LAMINATE C CENTERING DOOR OPENING LAV LAVATORY O DIAMETER LB5 POUNDS N POUND OR NUMBER LSS /HR POUNDS PER HOUR DRAWINGS 3F LD LINEAR DIFFUSER SG LP LOw POINT 1 LT LIGHT A/C AIR CONDITIONING EA EACH ACI AMERICAN CONCRETE INSTITUTE EPDXY COATING 51M ACP ASBESTOS CEMENT PIPE M EL ACSC ASPHALTIC CONCRETE SURFACE COURSE EJ EXPANSION JOINT ACU AIR CONDITIONING UNIT MATL MATERIAL ACT ACOUSTICAL CEILING TILE MAX MAXIMUM AD AREA DRAIN MC MEDICINE CABINET ADJ ADJUSTABLE MECH MECHANICAL A/E ARCHITECT/ENGINEER MEMS MEMBRANE AF ACCESS FLOORING MFR MANUFACTURER AFF ABOVE FINISHED FLOOR MIN MINIMUM AGGR AGGREGATE Mier— MIK_ELANEOU5 AHU AIR HANDLINGS UNIT MO MASONRY OPENING, ALT ALTERNATE MTD MOUNTED AL ALUMINUM MTL METAL ANN ANNUNCIATOR MUL MULLION ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MULT MULTIPLE ANT ANTENNA T FD AP ACCESS PANEL FG FIBERGLASS APL ACCESS PLENUM N TEL APROX APPROXIMATE TEMP FDC ARCH ARCHITECTURAL FDR FIRE DOOR ASS ASBESTOS N NORTH ASPH ASPHALT NEC NATIONAL ELECTRIC CODE A51T'l AMERICAN SOCIETY OF TESTING R MATERIALS NIC NOT IN CONTRACT TPRD FF NO NUMBER FH FRE HYDRANT ROM FIN nr TV NFL NAME PLATE Tw FM NT5 NOT TO SCALE SAT BATTERY FLG SD BOARD FLOUR FLUORESCENT BITUM BITUMINOUS G BLDG, BUILDING US FOM BL-KG BLOCKING FOS FACE OF STUD SM SEAM OA OVERALL SOT BOTTOM 055 0155CURE FRENCH DRAIN UTIL aC ON CENTER �. FT OD OUTSIDE DIAMETER DIM) FTG FOOTING OFS OVERFLOW SCUPPER FOOT POUNDS OFF OPPOSITE CAB CABINET FUTURE CT CS CATCH BASIN P CEM CEMENT GI CER CERAMIC CITY g� �{ p 9 GAUGE CI 1 Y �,s1'" SOUTH MIAM pVF CFM CUBIC FEET PER MINUTE PC PRECAST CONCRETE CG CORNER GUARD Pi PIPE JOINT CHP CRICKET HIGH POINT PL PLASTIC CI CAST IRON P LAM PLASTIC LAMINATE GIG CAST RON COVER PLAS PLASTER CIP CAST IRON PIPE PLYWO PLYWOOD CJ CONTROL JOINT PNT PAINT CLG CF_ILING PT POINT OR PATIENT GLGD CEILING DIFFUSER PTD PAPER TOWEL DISPENCER CLKG CAULKING PTN PARTITION CLO CLOSET PTR PAPER TOWEL RECEPTACLE CLP CRICKET LOW POINT HB HOSE BIS CLR CLOSER Q CMP CORRUGATEp METAL PIPE HDWE CMU CONCRETE MASONRY UNIT HGT HEIGHT CNTR COUNTER QRT QUARTER CO CLEAN OUT QT QUARRY TILE COL COLUMN HR HOUR COMM COMMUNICATION HEATER CONC CONCRETE R HYD CONN CONNECTION 0 ID N51DE DIAMETER ( DIAM ) CONSTS CONSTRUCTION NCHES CONT CONTINUOUS R REAR CPT CARPET TILE RA RETURN AIR CT CERAMIC TILE RAP RADIUS CTR CENTER RS REINFORCED SEAM CTSK COUNTERSUNK RCPT RECEPTION RD ROOF DRAIN REF REFERENCE REINF REINFORCED REQ REQUIRED DBL DOUBLE RESL RESILIENT DEG DEGREE 1`0�7TR REGISTER DEPT DEPARTMENT p ROOU�GH OPENING DESIG DESIGNATION RWL RAIN WATER LEADER DET DETAIL DF DRINKING FOUNTAIN DG DOOR GRILLE DIA DIAMETER S DIAL DIAGRAM DM DMENSION 5 DISR DISPENSER c„yC DN DOWN SCHED DO DOOR OPENING SEC DSP DRY STANDPIPE. SD DS DOWN SPOUT SECT DWG5 DRAWINGS 3F DWR DRAWER SG SGR 1 SHR SHT EA EACH SIG EC EPDXY COATING 51M EHD ELECTRIC HAND DRYER $K EL ELEVATION 5M EJ EXPANSION JOINT SINK ELEC ELECTRICAL SND ELEV ELEVATOR SPEC EMER EMERGENCY SPKR ENCL ENCLOSURE SQ ENGR ENGINEER SC.�FT EPNL ELECTRICAL PANEL SST EQ EQUAL 5T EQPT EQUIPMENT STC EST ESTIMATE $Tp ET EXPANSION TANK ST -D EWC ELECTRIC WATER COOLER STL EXH EXHAUST STRL EXST EXISTING SUSP EXT EXTERIOR SYM 5YS R T FA FIRE ALARM FABL FIRE ALARM BELL T FD FLOOR DRAIN TB FG FIBERGLASS TG FCO FLOOR CLEANOUT TEL FD FIRE DAMPER TEMP FDC FIRE DEPARTMENT CONNECTOR T*:G FDR FIRE DOOR THK FDN FOUNDATIONS TOC Fpv FIRE DEPARTMENT VALVE TOPI' FEC FIRE EXTINGUISHER CABINET TO$ FEX FIRE EXTINGUISHER TPRD FF FINISH FLOOR I FH FRE HYDRANT T5 TSTAT FIN FINISH TV FL FLOOR Tw FM FACTORY MANUAL T7P FLASH FLASHING FLG FLANGE U FLOUR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH US FOM FACE OF MASONRY UL UNF FOS FACE OF STUD U OS FFRF FIREPROOF UOS FFM FEET PER MINUTE UTI FRD FRENCH DRAIN UTIL FS FULL 51ZE FT FOOT OR FEET v FTG FOOTING FT -LS FOOT POUNDS FURR FURRING VS FUT FUTURE CT VERT VEST GI GA CITY g� �{ p 9 GAUGE CI 1 Y �,s1'" SOUTH MIAM pVF BUILDING DEPT. TR GL V A GALVANIZED GRADE W GHN GENERATOR `il- RUCTURAL SECTION! GL GLASS WR GND GROUND W GLB GLASS BLOCK W/ GR GRILLE WC GRO GRADE (J woo GINS GYPSUM WALL S6A ObOVED BY: z WD GYP GYPSUM /)rU �r W/o UIUFS° 14 C T WT Wx HB HOSE BIS WWM HC HANDICAPPED HOWD HARDWOOD HDWE HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH POINT HR HOUR HTR HEATER HVAC HEATING, VENTILATION, 4 AIR CONDITICNMG HYD HYDRANT 0 ID N51DE DIAMETER ( DIAM ) IN NCHES INT • INTERIOR J JAN JANITOR JB JUNCTION BOX JCT JUNCTON JSK JANITORS SINK JT JOINT K KO KNOCK OUT e STUCCO SCREED CONCRETE SCHEDULE SECOND SMOKE DETECTOR SECTION SUPPLY FAN SPANDREL GLASS SYNTHETIC GRADE SHOWER SHEET SGNAL SIMILAR SINK SHEET METAL SMOKE SOUND SPECIFICATION SPEAKERS SQUARE SQUARE FEET STAINLESS STEEL STREET SOUND TRANSMISSION COEFFICIENT STANDARD STORM DRAIN STEEL STRUCTURAL SUSPENDED SYMMETRICAL SYSTEM TOILET TIE SEAM TIE COLUMN TELEPHONE TEMPERATURE TONGUE AND GROVE THICK TOP OF CURS TOP OF PARAPET TOP OF SLAB TOP OF PAVEMENT TREAD TUBULAR STEEL THERMOSTAT TELEvISION TOP OF WALL TYPICAL UNDERCUT UNDERWRITER'S LABORATORIES UNFINISHED UNLESS OTHERWISE NOTED UNLESS OTHER SPECIFIED URINAL UTILITY VINYL BASE VINYL COMPOSITION TILE VERTICAL VESTIBULE VERIFY IN FIELD VOLUME VAPOR TIGHT VENT THRU ROOF- WIRE WINDOW WTH WATER CLOSET WALL CLEANOUT WOOD WALL FABRIC WITHOUT WATER PROOF WAINSCOT WEIGHT WELDED WIRE FAF3RIC WELDED WIRE MESH "aAsr� • } 4