10-732-037Eft C im F F{� ,r 4 I 13 A I f PARTIAL FIRST FLOOR PLAN -NEW CONSTRUCTION - PLUMBING LEGEND L DESCRIPTION rCONSTRUCTION EXISTING TO REMAIN NEW CONSTRUCTION CONNECT TO EXIST. AT THIS POINT 14 GENERAL NOTES. 1. CONTRACTOR SHALL PATCH WALLS TO MATCH EXISTING FINISHES FOR DEMOLITION AND INSTALLATION OF PIPING, FIXTURES, EQUIPMENT, ETC UNLESS NOTED OTHERWISE ON ARCH. DRAWINGS. 2. THE HOSPITAL IS OPEN 24 HOURS A DAY, 7 DAYS A WEEK. THE CONTRACTOR SHALL HAVE TO PERFORM WORK WITHIN ACTIVE PATIENT CARE AREAS. CONTRACTOR SHALL: A. COORDINATE SHUTDOWN OF EXISTING SYSTEMS WELL IN ADVANCE WITH OWNER. B. PERFORM WORK AT SUCH TIMES AND UNDER SUCH CONDITIONS AS PRESCIBED BY OWNER. C. PERFORM WORK WITHIN THE GUIDELINES OF THE ICRA REPORT PREPARED FOR THIS PROJECT BY THE OWNER. D. SEQUENCE DEMOLITION AND NEW CONSTRUCTION TO MINIMIZE NUMBER & DURATION OF SHUTDOWNS REQUIRED. 3. CONTRACTOR SHALL COORDINATE WORK WITH EXISTING CONDITIONS (STRUCTURE, DUCTWORK, PIPING, CONDUIT, ETC.). PROVIDE OFFSETS AS REQUIRED TO INSTALL NEW WORK. 4. ALL WASTE, STORM AND CONDENSATE PIPING 2' & LESS TO BE SLOPED 01 /4 /FT. ALL WASTE, STORM PIPING 21/1 & LARGER TO BE SLOPED a I /d /FT. 5. CONTRACTOR SHALL LABEL EXISTING PIPING TO REMAIN WITH IN AREA OF WORK PER SPECIFICATIONS. 6. WORK MAY NOT BE LIMITED TO SCOPE OF WORK OR PHASING AREAS INDICATED, BUT ALSO MAY INCLUDE WORK OUTSIDE OF THE SCOPE OF WORK OR PHASING AREAS AS INDICATED BY CONTRACT DOCUMENTS. 7. CONTRACTOR SHALL FIELD VERIFY WITH HOSPITAL LOCATION OF EXISTING SERVICE VALVES FOR SHUTDOWN OF CW AND HW. COORDINATE TIMING, DURATION AND AREA AFFECTED BY SHUTDOWN WITH HOSPITAL. KEYED NOTES: 0 RECONNECT HW, CW, VENT AND WASTE TO SINK. EXTEND 1/2 HW WATER TO CLINICAL SINK AND RECONNECT WASTE, VENT AND COLD WATER. .t a -Arch itpatv re Engineering Planning Anterior Cesigl Landscape Architecture 2601 Soizh- Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 MEP ENGINEER: Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (454) 421 -1260 FAX: (954) 421 -1466 www.ssr - inc.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A. Steward PE - 65701 SSR JOB # 1032062.0 t%%111111111., It., % ♦,t,N . Mo!jz % 3 ik = R PERMIT' SUBMITTAL CD PHASE REVISIONS: PROJECT NAME: SOUTH MIAMI HOSPITAL EAST TOWER FIBROID CENTER B PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 0 COMM. NO. 40062.100 SCALE: DATE: JUNE 30.2010 DRAWN: A CHECKED: CADD FILE: DRAWING TITLE: PARTIAL FIRST FLOOR NEW CONSTRUCTION PLUMBING SHEET NO. s.