Loading...
10-732-023r� ............9 IIIIIIIIWI t. A I 9 PANEL, INL3 OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINSCA), MLO CONTINUOUSCA), 225 LOCATION, DEVICE FAMILY, Bolt On MOUNTING, Flush WIRING, 3 -Phase 4 -Wire AIC RATING(A), 10000 FED FROM, PNL INLD1 VOLTAGE, 208/120 FAULT CURRENT(A) 6642 EXISTING PANEL CKT DESCRIPTION NOTES DEMAND VA OC PHASE DC VA DEMAND NOTES DESCRIPTION CKT 314 50 4 #8 & 1 #IOG. CODE 2 AMPS P 3 #6 & 1 #10G. AMPS P 60 CODE 1' 4 5 1 OFFICE 157 EXISTING RECEPTACLES 900 20 1 A 40 2 5554 GENERAL EOUI EXISTING REC. THERAP 156 KILN 2 3 OFF. 158/RECEPT 159 EXISTING RECEPTACLES 1080 20 1 B 20 1 - CONTINUOUS L EXISTING CORRIDOR 4 5 OFFICES 159 -160 EXISTING RECEPTACLES 1080 20 1 C 20 1 1080 RECEPTACLES EXISTING OFFICES 167 -168 6 7 OFFICES 152 -155 EXISTING LIGHTING 1193 20 1 A 20 1 1080 RECEPTACLES EXISTING OFFICE 169 e 9 REC THER. 156 EXISTING LIGHTING 1200 20 1 B 20 1 1080 RECEPTACLES EXISTING OFFICES 177 -178, 180 10 11 OFFICES 157-160 EXISTING LIGHTING 1360 20 1 C 20 1 1080 RECEPTACLES EXISTING OFF 191- 19UCDRR 186 12 13 OFFICES 167 -178 EXISTING LIGHTING 1200 20 1 A 20 1 1080 RECEPTACLES EXISTING OFFICES 194 -195 14 15 OFFICES 191 -196 EXISTING LIGHTING 1280 20 1 B 20 1 1080 RECEPTACLES EXISTING OFFICE 196 /GROUP 185 16 17 OFFICES 176,181 -183 EXISTING LIGHTING 1058 20 1 C 20 1 1080 RECEPTACLES EXISTING GROUP 185 /CORK 186 18 19 CORR 161,166,175,179 EXISTING LIGHTING 785 20 1 A 20 1 1080 RECEPTACLES EXISTING OFFICE 183 20 21 PHYSICAL THERAPY 170 EXISTING LIGHTING 1320 20 1 B 20 1 900 RECEPTACLES EXISTING GROUP 181 22 23 OFFICES 152,154 EXISTING RECEPTACLES 900 20 1 C 20 1 1080 RECEPTACLES EXISTING GROUP 176,182 24 25 OFFICE 155 /REC THER. EXISTING RECEPTACLES 720 20 1 A 20 1 540 RECEPTACLES EXISTING GROUP 176 26 27 FOOD SERV. 152 MICRO EXISTING RECEPTACLES 1000 20 1 B 20 1 1080 RECEPTACLES EXISTING CORRIDOR 175,179 28 29 FOOD SERV. 152 COFFE EXISTING RECEPTACLES 1000 20 1 C 20 1 900 RECEPTACLES EXISTING PHYSICAL THERAPY 170 30 31 SPARE EXISTING SPARE 0 20 1 A 20 1 720 RECEPTACLES EXISTING RMS 163 -164 32 33 REC, THERAPY 156 EXISTING RECEPTACLES 720 20 1 B 20 1 1080 RECEPTACLES EXISTING CORR 161,166 /OFFICE 34 35 REC. THERAPY COFFEE EXISTING RECEPTACLES 1000 20 1 C 20 1 540 RECEPTACLES EXISTING ROOF 36 37 REC. THERAPY MICRO EXISTING RECEPTACLES 1000 20 1 A 20 1 180 RECEPTACLES EXISTING SURACE REC RM 154 38 39 REC. THERAPY RANGE EXISTING GENERAL EDUI 7280 50 2 B 20 1 540 RECEPTACLES NOTE 1 EXAM 165 40 41 SPARE EXISTING SPARE - of C 20 1 0 SPARE EXISTING SPARE 42 ALL CONNECTED KVA MAX PH AMPS ■ PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 47.83 156.4 ■ A -N 13351.4 11112 CONNECTED 47.83 TOTAL DEMAND 26.83 94.7 x B -N 18783.4 156.4 DEMAND 26.83 TOTAL DESIGN 27.77 97.9 ■ C -N 15937.2 132.7 DESIGN 27.77 NOTE to USE EXISTING C. B. PANEL, iLSLl OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINSCA), MLO CONTINUOUSCA)i 100 LOCATION, DEVICE FAMILY, Bolt On MOUNTING, Surface WIRING, 3 -Phase 4 -Wire AIC RATING(f), 10000 FED FROM, PNL 2LSLD1 VOLTAGEa 208/120 FAULT CURRENT(A) 5249 EXISTING PANEL CKT DESCRIPTION NOTES DEMAND VA OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT 314 50 4 #8 & 1 #IOG. CODE 2 AMPS P 3 #6 & 1 #10G. AMPS P 60 CODE 1' 4 5 1 GENERATOR ROOM EXISTING RECEPTACLES 360 20 1 A 20 1 920 CONTINUOUS L EXISTING CORRIDOR/LOBBY 2 3 GENERATOR ROOM EXISTING LIGHTING 200 20 1 B 20 1 880 CONTINUOUS L EXISTING CORRIDOR 4 5 FACP EXISTING GENERAL EDUI 400 20 1 C 20 1 400 CONTINUOUS L EXISTING SOUTH WALL EXTERIOR 6 7 FATC EXISTING GENERAL EOUI 400 20 1 A 20 1 500 LIGHTING EXISTING FLOOD LTS SW WALL 8 9 ELEVATOR CAB LTS EXISTING LIGHTING 400 20 1 B 20 1 500 LIGHTING EXISTING FLOOD LTS NE WALL 10 11 MGAP FIBRIOD CENTER NOTE 1 GENERAL EOUI 500 20 1 C 20 1 0 SPARE EXISTING SPARE 12 13 SPARE EXISTING SPARE 0 20 1 A 20 1 0 SPARE EXISTING SPARE 14 15 SPARE 700 SPARE 0 20 1 B 20 1 0 SPARE EXISTING SPARE 16 17 SPARE 3 -3' SPARE 0 20 1 C 20 1 0 SPARE EXISTING SPARE 18 19 SPARE EXISTING SPARE 0 20 1 A 20 1 0 SPARE EXISTING SPARE 20 21 SPARE EXISTING SPARE 0 20 1 B 20 1 0 SPARE EXISTING SPARE 22 23 SPARE EXISTING SPARE 0 20 1 C 20 1 0 SPARE EXISTING SPARE 24 25 SPARE EXISTING SPARE 0 20 1 A 20 1 0 SPARE EXISTING SPARE 26 27 SPARE EXISTING SPARE 0 20 1 B 20 1 0 SPARE EXISTING SPARE 28 29 SPARE EXISTING SPARE 0 20 1 C 20 1 0 SPARE EXISTING SPARE 30 31 SPARE EXISTING SPARE 0 20 1 A 20 1 0 SPARE EXISTING SPARE 32 33 SPARE EXISTING SPARE 0 20 1 B 20 1 0 SPARE EXISTING SPARE 34 35 SPARE EXISTING SPARE 0 20 1 C 20 1 0 SPARE EXISTING SPARE 36 37 SPARE EXISTING SPARE 0 20 1 A 20 1 0 SPARE EXISTING SPARE 38 39 SPARE EXISTING SPARE 0 20 1 B 20 1 0 SPARE EXISTING SPARE 40 41 SPARE EXISTING SPARE 0 20 I G 20 1 0 SPARE EXISTING SPARE 42 ALL CONNECTED KVA MAX PH AMPS ■ PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 5.46 18.2 ■ A -N 2180. 0 18.2 CONNECTED 5.46 TOTAL DEMAND 4.28 13.9 ■ B -N 1980. 0 16.5 DEMAND 4.28 TOTAL DESIGN 4.99 16.2 ■ C -N 1300.0 10.8 DESIGN 4.99 NOTE to USE EXISTING C. B. Q A PANEL, ICLI OC DEVICE TYPE, Breaker ENCLOSURE, NEMA 1 MAINS(A), MLO CONTINUOUSCA), 150 LOCATION, DEVICE FAMILY, Bolt On MOUNTING, Surface MIRING, 3 -Phase 4 -Wire AIC RATING(A), 22000 FED FROM, PNL 2CLD1 VOLTAGE, 208/120 FAULT CURRENT(A) 9904 EXISTING PANEL CKT DESCRIPTION NOTES DEMAND VA I OC PHASE OC VA DEMAND NOTES DESCRIPTION CKT 314 50 4 #8 & 1 #IOG. CODE 2 AMPS P 3 #6 & 1 #10G. AMPS P 60 CODE 1' 4 5 1 REC OFFICE 134 -136 EXISTING RECEPTACLES 540 20 1 A 20 1 360 RECEPTACLES EXISTING TELECOM ROOM 125 2 3 REC RM 133 /137 EXISTING RECEPTACLES 540 20 1 B 20 1 360 RECEPTACLES EXISTING TELECOM ROOM 125 4 5 REC RM 138 /142 /143 EXISTING RECEPTACLES 540 20 1 C 20 1 1280 LIGHTING EXISTING LIGHTING NW WING 6 7 REC RM 144 /146 EXISTING RECEPTACLES 540 20 1 A 20 1 1250 LIGHTING EXISTING LOCK 131 /MAINT /OFF. 8 9 REC RECEPTION 141 EXISTING RECEPTACLES 540 20 1 B 20 1 1413 LIGHTING EXISTING TREAT 104 - 109 /STO/EQ 10 11 REC RM 139 /140 EXISTING RECEPTACLES 720 20 1 C 20 1 1520 LIGHTING EXISTING OCC. THER 110 /MASSAG 12 13 REC LBY 149/ RM 114 EXISTING RECEPTACLES 360 20 1 A 20 1 887 LIGHTING EXISTING PHY THER 170 /STO 115 14 15 SPARE 700 SPARE 0 20 1 B 20 1 853 LIGHTING EXISTING GROUP RMS 176,181,85 16 17 SPARE 3 -3' SPARE 0 20 1 C 20 1 1283 LIGHTING EXISTING REC. THER 15 /REC 159 18 19 LOCKSMITH 131 EXISTING RECEPTACLES 720 20 1 A 20 1 360 RECEPTACLES EXISTING TELECOM ROOM 125 20 21 LOCKSMITH 131 EXISTING RECEPTACLES 720 20 1 B 20 1 1080 RECEPTACLES EXISTING OFFICES 157 -159 22 23 LOCKSMITH 131 EXISTING RECEPTACLES 360 20 1 C 20 1 720 RECEPTACLES EXISTING OFF 152 - 155 /REC THER 24 25 LOCKSMITH 131 EXISTING RECEPTACLES 360 20 1 A 20 1 900 RECEPTACLES EXISTING REC. THERAPY REF, 26 27 MAINT 128 /HOUSEK 129 EXISTING RECEPTACLES 900 20 1 B 20 1 900 RECEPTACLES EXISTING OFF. 160,167 - 169,177 28 29 TREAT/OCC. THER. 110 EXISTING RECEPTACLES 720 20 1 C 20 1 1080 RECEPTACLES EXISTING OFF. 183,191,194 -196 30 31 ATM 147 EXISTING RECEPTACLES 360 20 1 A 20 1 900 RECEPTACLES EXISTING FOOD SERVICE DISPLAY 32 33 OCC. THERAPY 110 EXISTING RECEPTACLES 720 20 1 B 20 1 800 RECEPTACLES EXISTING VENDING MACHINE 34 35 PHYSICAL THERAPY 170 EXISTING RECEPTACLES 540 20 1 C 20 1 800 RECEPTACLES EXISTING VENDING MACHINE 36 37 PYS THER/ RM 164/165 EXISTING RECEPTACLES 540 20 1 A 20 1 800 RECEPTACLES EXISTING VENDING MACHINE 38 39 STORAGE 115 EXISTING RECEPTACLES 360 20 1 B 20 1 600 GENERAL EQUI EXISTING NCT 40 41 TELECOM ROOM 125 EXISTING RECEPTACLES 360 20 1 C 20 1 180 RECEPTACLES EXISTING SECURITY CORR #161 42 43 SEC GATE VALET PARKI EXISTING GENERAL EaUI 500 20 1 A 20 1 0 SPARE SPARE 44 45 EXAM 164 NOTE 1 RECEPTACLES 360 20 1 B 20 1 0 SPARE SPARE 46 47 EXAM 165 NOTE 1 RECEPTACLES 360 20 1 C 20 1 0 SPARE SPARE 48 49 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 50 51 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 52 53 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 54 55 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 56 57 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 58 59 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 60 61 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 62 63 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 64 65 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 66 67 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 68 69 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 70 71 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 72 73 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 74 75 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 76 77 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 78 79 SPARE SPARE 0 20 1 A 20 1 0 SPARE SPARE 80 81 SPARE SPARE 0 20 1 B 20 1 0 SPARE SPARE 82 83 SPARE SPARE 0 20 1 C 20 1 0 SPARE SPARE 84 ALL CONNECTED KVA MAX PH AMPS ■ PHASE TOTALS VA AMPS BUS TOTALS KVA TOTAL CONNECTED 29.99 87.1 ■ A -N 9377.0 78.1 CONNECTED 29.99 TOTAL DEMAND 12.65 36.8 R B -N 10146.0 84.5 DEMAND 12. 65 TOTAL DESIGN 13.50 38.7 ■ C -N 10463.0 87.1 DESIGN 13.50 NOTE V USE EXISTING C. B. r, 6 FEEDER SCHEDULE BASED ON N.E.C. TABLE 310 -16 FOR COPPER CONDUCTORS FEEDER SYMBOL CONDUCTORS (3 PHASE, 3 WIRE) WITH GROUND RACEWAY SIZE CONDUIT NOMINAL AMPERE RATING CONDUCTORS (3 PHASE, 4 WIRE) WITH GROUND RACEWAY SIZE CONDUIT FEEDER SYMBOL 1 3 #8 & 1 #10G. 314 50 4 #8 & 1 #IOG. }' 2 3 3 #6 & 1 #10G. 314 60 4 #6 & 1 #10G. 1' 4 5 3 #4 & 1 #8G. 1' 70 4 #4 & 1 #8G. 1 114 6 7 3 #3 & 1 #8G. 1 114 100 1 4 #3 & 1 #8G. 1 114 8 9 3 #1 & 1 #6G. 1 1/1 125 4 #1 & 1 #6G. 2' Q 11 3 #1/0 & 1 #6G. 1 1/1 150 4 #1 /0 & 1 #6G. 2' 12 13 3 #2/0 & 1 #6G. 2' 175 4 #2/0 & 1 #6G. 2' 14 15 3 #3/0 & 1 #6G. 2' 200 4 #3/0 & 1 #6G. 2' 16 17 3 #4/0 & 1 #4G. 2' 225 4 #4 /0 & 1 #4G. 2 1/1 18 19 3 #250 KCMIL & 1 #4G. 2 1/1 250 4 #250 KCMIL & 1 #4G. 2 1/¢ Q 2l 3 #350 KCMIL & 1 #4G. 3' 300 4 #350 KCMIL & 1 #4G. 3' 2 3 3 #500 KCMIL & 1 #3G. 3 1/1 350 4 #500 KCMIL & 1#3G. 3 1/¢ 4 5 3 #600 KCMIL & 1 #3G. 3 1/1 400 4 #600 KCMIL & 1 #3G. 4' 6 7 6 #250 KCMIL & 2 #2G. 2-2 500 8 #250 KCMIL & 2 #2G. 2 -2 1/1 8 9 6 #350 KCMIL & 2 #1G. 2-3' 600 8 #350 KCMIL & 2 #IG. 2 -3' Q 31 6 #500 KCMIL & 2 #1 /OG. 2-3' 700 8 #500 KCMIL & 2 #1 /OG. 2 -3 1/¢ 2 3 6 #600 KCMIL & 2 #1 /OG. 2-3 1/1 800 8 #600 KCMIL & 2 #1 /OG. 2 -4' 4 5 9 #400 KCMIL & 3 #2 /OG. 3 -3' 1000 12 #400 KCMIL & 3 #2 /OG. 3 -3' 6 7 9 #600 KCMIL & 3 #3 /OG. 3 -3 1/1 1200 12 #600 KCMIL & 3 #3 /OG. 3 -4' 8 9 12 #600 KCMIL & 4 #4 /OG. 4 -3 1/1 1600 16 #600 KCMIL & 4 #4 /QG. 4 -4' 4O 41 15 #600 KCMIL & 5 #250G. 5 -3 1/1 2000 20 #600 KCMIL & 5 #250G. 5 -4' 42 43 18 #600 KCMIL & 6 #350G. 6-3 W 2500 24 #600 KCMIL & 6 #350G. 6 -4' 44 45 21 #750 KCMIL & 7 #400G. 7-4' 3000 28 #750 KCMIL & 7 #400G. 7 -5' 46 47 27 #750 KCMIL & 9 #500G. 9-4' 4000 36 #750 KCMIL & 9 #500G. 9 -5' 48 NOTES: 1.600 KCMIL AND 750 KCMIL FEEDERS SHALL BE COORDINATED WITH PROPER TERMINATION LUGS OR PROVIDED WITH MAC ADAPTERS AS REQUIRED TO COORDINATE WITH STANDARD BREAKER LUG SIZES. 2. SEE SPECIFICATIONS FOR ACCEPTABLE CONDUCTOR TYPES. THIRD FLOOR i L CONNECT SWITCHBOARD. PARTIAL ELECTRICAL RISER DIAGRAM NTS NOTE : ALL ELECTRICAL PANELS, FEEDERS, EQUIPMENT, ETC... ARE EXISTING TO REMAIN. KEYED NOTES: EXISTING PANEL MODIFIED UNDER THIS PROJECT. PROVIDE NEW PANEL DIRECTORY. 1�2 PROVIDE #IOAWG INSULATED GROUNDING CONDUCTOR BETWEEN GROUND BUSES OF PANELS 1CL1 AND 1NI-3 IN /2 CONDUIT WITH GROUNDING BUSHINGS. J z I XXX FLOOR WHERE 0 10 PANE IS LOCATED NORMA SYSTE milli , ski ..sk PANEL NAME C.B. SIZE FEEDING THIS PANEL BRANCH DESIGNATION I Architecture Engineering Planning Interior Design Landscape Architecture 2601 So-�th_Baysnore :Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 VIEP ENGINEER: 2nSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A. Steward PE - 65701 SSR JOB # 1032062.0 PERMIT SUBMIII TTAL CD PHASE PROJECT NAME: SOUTH MIAMI HOSPITAL EAST TOWER FMROTD CENTER B a' PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 GM COMM. NO. 40062.100 SCALE: DATE: JUNE 30.2010 DRAWN: A CHECKED: CADD FILE: DRAWING TITLE: PARTIAL ELECTRICAL RISER DIAGRAM & PANEL SCHEDULES SHEET NO. E4.1 a a