Loading...
10-732-019mum IIIIIIIIIIIA -? W 2 AREA OF WORK AREA OF WQR 3 4 >a [ __ ._ _._..._ __ -- _ [ ILSLLI -4 . ,. I N - I L3 32 1CL — .� 1 I 1CLI -18 1CL1 -18 .F I INL3 -9 INL3 -9 INL3 -19 0 0 10 w �. : �, ., .� INL3 - INL3 env IC„I [ INL3— 2 — 3 L1 37 7 2 ILSL1 -4 I INL3 -9 INL3 -9 1LSL1 -4 [ I r } x Skl J17-1 :F I [ I 1CLI -1�` 1CLI -18 I 1 11 :. r TYPICAL FOR ALL t .. ....... ...... ........ .: „ C� , A l `nd .,. A �f I ,_INL3 -11 INL3 -lI INL3 -7 INL3 -7 PARTIAL FIRST FLOOR PLAN - DEMOLITION - ELECTRICAL 0' 1' 2' 4' W 12' GENERAL NOTES: A. UNLESS OTHERWISE NOTED, ALL POWER, DATA AND SYSTEMS SHALL BE EXISTING TO REMAIN. B. REFER TO SHEET EI.2 FOR LOCATION OF EXISTING ELECTRICAL PANELS. C. THE FIRE ALARM SYSTEM MUST BE MAINTAINED DURING CONSTRUCTION. THE CONTRACTOR MAY COVER SMOKE DETECTORS WHILE PRESENT BUT MUST LEAVE A FULLY FUNCTIONAL FIRE ALARM SYSTEM WHEN NOT PRESENT OR PROVIDE A COUNTY APPROVED FIRE WATCH Fl 1 �1 EXISTING THREE WAY SWITCH TO BE REPLACED WITH NEW SINGLE POLE SWITCH. REFER TO NEW WORK ON SHEET E2.1. 2 EXISTING THREE WAY SWITCH AND ASSOCIATED CONDUIT AND WIRES TO BE REMOVED. �3 DISCONNECT EXISTING LIGHT FIXTURE FROM EXISTING SWITCH CIRCUIT. REFER TO NEW WORK ON SHEET E2.1 FOR NEW SWITCHING. �4 EXISTING EXIT LIGHT TO BE REMOVED AND REPLACED WITH NEW DOUBLE FACE EXIT LIGHT. MAINTAIN CIRCUIT FOR CONNECTION TO NEW EXIT LIGHT. REFER TO SHEET E2.1 FOR NEW WORK. �5 EXISTING RECEPTACLE TO RELOCATED. EXTEND CONDUIT AND WIRES TO NEW LOCATION AS REQUIRED. REFER TO SHEET E3.1 FOR NEW LOCATION. 6 EXISTING PUBLIC ADDRESS SPEAKER TO BE RELOCATED TO ACCOMODATE INSTALLATION OF NEW WALL. REFER NEW WORK ON SHEET E3.1 FOR NEW LOCATION. 7 EXISTING RECEPTACLE TO BE RECIRCUITED. PROVIDE NEW ENGRAVED DEVICE PLATE. REFER TO SHEET E3.1 FOR NEW CIRCUITING. 8 REMOVE EXISTING LIGHT FIXTURES. TURN OVER ONE FIXTURE TO OWNER AND RELOCATE OTHER FIXTURE PER NEW WORK SHOWN ON SHEET E2.1. REMOVE EXISTING RECEPTACLE. EXTEND CONDUIT AND WIRE TO NEW GFI RECEPTACLE AT NEW CLEAN UTILITY. REFER TO SHEET E3.1 FOR NEW WORK. 10 RELOCATE EXISTING FIRE ALARM VISUAL DEVICE TO NEW WAITING ROOM. REFER TO SHEET E3.1 FOR NEW LOCATION. EXTEND ALL CONDUIT AND WIRE AS REQUIRED. PROVIDE FIRE ALARM CERTIFICATION AT COMPLETION OF WORK. 11 EXISTING LIGHT FIXTURE SHALL REMAIN AND SHALL BE RE— CIRCUITED. DISCONNECT FROM EXISTING SWITCH. REFER TO NEW WORK ON SHEET E2.1 FOR NEW CIRCUIT SERVING LIGHT FIXTURE. 1 3 1CLI —i8'.. € INL3 -11 INL3 -11 �t r [ U t I 2 DEMOLITION LEGEND SYMBOL DESCRIPTION EXISTING TO REMAIN EXISTING TO BE REMOVED IN • 1 • IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE EXI STI NG EQUI PMENT AS REQUIRED TO ACCOMPLISH THE NEW WORK AS SHOWN OR REASONABLY I MPLI ED. THE CONTRACTOR SHALL REFER TO THE NEW ARCHITECTURAL, PLUMBING, FIRE PROTECTION, MECHANICAL AND ELECTRICAL WORK SHOWN ON THE OTHER DRAWINGS OF THIS SET TO DETERMINE THE EXTENT OF DEMOLITION REQUIRED. WHEN REMOVING ELECTRICAL EQUIPMENT AND SYSTEMS, ALL PRECAUTIONS SHALL BE TAKEN TO PREVENT STRUCTURAL DAMAGE TO THE BUILDING. THE CONTRACTOR SHALL COORDINATE INSTALLATION OF ANY STRUCTURAL SUPPORTS REQUIRED, TEMPORARY OR PERMANENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL DEMOLITION AND CONSTRUCTION DEBRIS GENERATED FROM WORK ON ALL FLOORS. TAKING CARE TO PREVENT EXCESSIVE LOADING OF FLOOR ASSEMBLIES. THE CONTRACTOR SHALL MAINTAIN CONTINUITY OF CIRCUITS WHERE EXISTING EQUIPMENT IS TO BE REMOVED AND DOWN STREAM DEVICES MAY BE EFFECTED. THE CONTRACTOR SHALL COORDINATE ALL POWER INTERRUPTIONS WITH OWNER. SEE SPECIFICATIONS. WHEN EXISTING ELEMENTS OF ELECTRICAL EQUIPMENT AND SYSTEMS ARE REMOVED, ALL REMAI NI NG OPENI NGS I N THE SLAB AND WALLS SHALL BE FI LLED I N BY THE CONTRACTOR. THE FIRE RATING OF THE EXISTING STRUCTURE SHALL BE MAINTAINED. REMOVE ALL MISCELLANEOUS FIXTURES AND EQUIPMENT RETAINING ITEMS TO BE IDENTIFIED FOR SALVAGE AND STORAGE AT THE DIRECTION OF THE OWNER. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO MAINTAIN THE INTEGRITY AND OPERATION OF EXISTING LIFE SAFETY AND EMERGENCY EGRESS EQUIPMENT. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO MAINTAIN ACCESS TO ALL MEANS OF EGRESS CORRIDORS, DOORWAYS AND STAIRS. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS DURING DEMOLITION AND CONSTRUCTION TO PERMIT EFFECTED AREAS TO CONTINUE TO FUNCTION TO THE GREATEST EXTENT POSSIBLE. THIS EFFORT SHALL INCLUDE SCHEDULED COORDINATION WITH OWNER OF ELECTRICAL SHUTDOWNS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL FLUORESCENT AND HID TYPE LAMPS AND PROPER DISPOSAL OF SAID LAMPS AND SHALL PROVIDE VERIFICATION OF LAMP DISPOSAL TO THE OWNER UPON REQUEST. REMOVE ALL LIGHTING FIXTURES, RECEPTACLES AND DEVICES IN THE AREA OF DEMOLITION AND PULL ALL CIRCUITS BACK TO NEXT ACTIVE DEVICE OR SOURCE OF POWER. ALL CONDUIT, JUNCTION BOXES AND WIRING DEVICES THAT ARE NOT INTENDED TO RE -USED MUST BE DEMOLISHED BACK TO THE SOURCE. PROVIDE PANEL SCHEDULES, TO THE ENGINEER, INDICATING THE CIRCUITS MADE SPARE BY DEMOLI TI ON AND THE EXI STI NG CI RCUI TS THAT REMAI N ACTI VE. I T SHALL BE THE RESPONSI BI LI TY OF THE CONSTRUCTI ON MANAGER ( CM) , GENERAL CONTRACTOR ( GC) , AND THE SUB - CONTRACTORS ( SC) TO STUDY ALL THE DRAWI NGS AND DETAI LS SO THAT THE I NSTALLATI ON OF ALL NEW WORK CAN BE FULLY COORDI NOTED. THE CM, GC, AND SC SHALL VI SI T THE SI TE, I NCLUDI NG DOI NG AN ABOVE CEI LI NG I NSPECTI ON, DURI NG BI DOI NG TO SATI SFY HI M /HER SELF THAT ALL PROVISIONS HAVE BEEN MADE FOR ALL ASPECTS OF THIS PROJECT. IF DISCREPANCIES EXIST BETWEEN DRAWINGS AND /OR SITE CONDITIONS, THE CONTRACTOR SHALL NOTI FY THE GENERAL CONTRACTOR I N WRI TI NG PRI OR TO BI D DUE DATE. FAILURE TO DO SO WI LL NOT BE ALLOWED ON A BASIS FOR ADDI TI ONAL COMPENSATION TO CORRECT A DIFFICULTY OF DIFFERENCE FROM CONDITIONS INFERRED OR INDICATED ON THE DRAWI NGS. DRAWI NGS ARE DI AGRAMMATI C AND DO NOT I NDI CATE ALL DEVI CES TO BE DEMOLI SHED. CONTRACTOR SHALL VI SI T JOB SI TE PRI OR TO BI D TO FI ELD CONFI RM ALL REQUI REMENTS. J i . - - - - Arch'.t =cure Engineering, Planning _IriIterior De -ign Landscape Ari;hitecture - 2501 -Scut! Bayah6e Drro -10t'1 Floor Miami, Florida 33133 E (305) 859 -2050 Fax (305) 860 -3700 MEP ENGINEER: Smith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A. Steward. PE - 65701 SSR JOB # 1032062.0 ,i C 4 /0 PERMIT SUBMITTAL CD PHASE REVISIONS: PROJECT NAME: SOUTH MIAMI HOSPrrAL EAST TOWER FIBROID CENTER. B PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 COMM. NO. 40062.100 SCALE: DATE: TUNE 30.2010 DRAWN: A CHECKED: CADD FILE: DRAWING TITLE: PARTIAL FIRST FLOOR DEMOLITION ELECTRICAL SHEET NO. E1.1