10-732-018E D C B A 1 T 1 7 Z A A 6 ABBREVIATIONS SYMBOL DESCRIPTION ABC ABOVE COUNTER ACLG ABOVE FINISHED CEILING AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE BKR BREAKER CB CIRCUIT BREAKER CKT CIRCUIT CL CENTER LINE CLG CEILING MOUNTED DEVICE DISC DISCONNECT DIV DIVISION ECB ENCLOSED CIRCUIT BREAKER EX EXISTING EXR EXISTING, RELOCATED F FRAME F/A FIRE ALARM FCU FAN COIL UNIT FLA FULL LOAD AMPS FU FUSE G GROUND HP HORSE POWER K KILO ABBREVIATIONS SYMBOL DESCRIPTION MCB MAIN CIRCUIT BREAKER MLO MAIN LUGS ONLY NCT NURSE CALL TERMINAL CABINET NEC NATIONAL ELECTRIC CODE NIC NOT IN CONTRACT NL NIGHT LIGHT OC OVER CURRENT OCP OVER CURRENT PROTECTION P POLE PH PHASE SMH SPECIAL MOUNTING HEIGHT TV TELEVISION TYP TYPICAL UH UNIT HEATER UG UNDER GROUND ELECTRICAL LION UNLESS OTHERWISE NOTED LION UNINTERRUPTIBLE POWER SUPPLY V VOLT(S) VA VOLT- AMP(S) W WATT(S), WIRE, WALL TELEPHONE OUTLET WP WEATHERPROOF DEVICE, NEMA 3R XFMR TRANSFORMER LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT LIGHTING EP ®NORMAL EO.0 BRANCH SURFACE OR RECESSED FLUORESCENT (PULL CORD TO EXTEND WITHIN 2' A.F.F.) PARTIAL FIRST FLOOR - DEMOLITION - ELECTRICAL Q STAFF STATION FIXTURE (TYPE DETERMINES MOUNTING) © DOME LIGHT PARTIAL FIRST FLOOR - NEW CONSTRUCTION - POWER & SYSTEMS SOUND SYSTEM OR EQUIPMENT BRANCH SURFACE OR RECESSED CEILING PAGING SPEAKER CEILING MTD. ®CRITICAL q= FLUORESCENT FIXTURE (TYPE DETERMINES MOUNTING) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) LIFE- SAFETY BRANCH SURFACE OR RECESSED FLUORESCENT MOTOR CONNECTION UH UNIT HEATER CONNECTION FIXTURE (TYPE DETERMINES MOUNTING) ❑D O NORMAL BRANCH SURFACE OR RECESSED FIXTURE O JUNCTION BOX (TYPE DETERMINES MOUNTING) s PANELBOARD - FLUSH MOUNTED ® (2) CRITICAL OR EQUIPMENT BRANCH SURFACE OR RECESSED FIXTURE WG A-P MEDICAL GAS ALARM PANEL (TYPE DETERMINES MOUNTING) CARD READER ®LIFE- ® SAFETY BRANCH SURFACE OR RECESSED FIXTURE CONCEALED CONDUIT (TYPE DETERMINES MOUNTING) CONDUIT CONCEALED IN FLOOR OR BELOW GRADE EXIT LIGHT, PROVIDE DIRECTIONAL ARROWS AS INDICATED HOMERUN TO PANELBOARD - NUMBER OF PHASE CONDUCTORS IN MINIMUM 314 ON PLANS CONDUIT UNLESS NOTED OTHERWISE SWITCHES S SINGLE POLE SWITCH - IVORY TOGGLE 31-10' AFF TO CL INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. SINGLE POLE SWITCH - RED TOGGLE 3' -10' AFF TO CL S3 THREE WAY SWITCH - IVORY TOGGLE 31-10' AFF TO CL $T MOTOR RATED SWITCH WITH THERMAL OVERLOAD CONDUCTORS (ONE PER PHASE) PLUS THREE (3) NEUTRAL CONDUCTORS AND POWER - RECEPTACLES ALL RECEPTACLES SHALL BE IVORY, EXCEPT WHERE INDICATED WITH SUBSCRIPT. SUBSCRIPT 'C' SHALL INDICATE EMERGENCY — PROVIDE RED DEVICE AND PLATE 4. MULTI -WIRE BRANCH CIRCUITS THAT SHARE A COMMON NEUTRAL SHALL NOT BE 120V. DUPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE 11-6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL USING CABLE TIES AT THE PANELBOARD AND ALL JUNCTION BOXES, PULL BOXES 120V. DUPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) ". SEE SPECS 6. ALL CONDUCTORS SHALL BE *12 AWG UNLESS OTHERWISE NOTED. 120V. QUADPLEX RECEPTACLE - IVORY (REFER TO RECEPTACLE 1' -6' ABBREVIATIONS FOR EXCEPTIONS) AFF TO CL 120V. QUADPLEX RECEPTACLE - IVORY - SPECIAL MOUNTING HEIGHT AS NOTED OR (REFER TO RECEPTACLE ABBREVIATIONS FOR EXCEPTIONS) SEE SPECS �}- 120V. GFI RECEPTACLE (SPECIAL MOUNTING HEIGHT) AS NOTED OR SEE SPECS Q- 120V. GFI RECEPTACLE AFF TO CL TELEPHONE /DATA q COMBINATION DATA /TELEPHONE OUTLET WITH PLATE AFF TO CL 4 COMBINATION DATA /TELEPHONE OUTLET WITH PLATE AS NOTED (SPECIAL MOUNTING HEIGHT) SEE SPECS. CONTRACTOR SHALL PROVIDE 4'X4' BACKBOX WITH 3 /CONDUIT WITH BUSHING STUBBED TO ACCESSIBLE CORRIDOR CEILING - WIRING BY OTHE S. FIRE ALARM FIRE ALARM VISUAL STATION - LIGHT ONLY FIRE ALARM CHIME WITH LIGHT a FIRE ALARM SMOKE DETECTOR CEILING ®s DUCT SMOKE DETECTOR - SUPPLY DUCT SEAL PENETRA'''^ "`' TO MAINTAIN R, WALL FOR FIRE FIRE RATED WALL CONDUIT ENDS SO AS STING OF WALL FOR FIRE PROOFING. RATED WALL PENETRATIONS LEGEND SYMBOL DESCRIPTION MOUNTING HEIGHT NURSE CALL EP EMERGENCY PULL CORD STATION EO.0 ELECTRICAL LEGENDS, SCHEDULES,AND DRAWING INDEX (PULL CORD TO EXTEND WITHIN 2' A.F.F.) PARTIAL FIRST FLOOR - DEMOLITION - ELECTRICAL Q STAFF STATION E2.1 © DOME LIGHT PARTIAL FIRST FLOOR - NEW CONSTRUCTION - POWER & SYSTEMS SOUND SYSTEM Ps CEILING PAGING SPEAKER CEILING MTD. MISCELLANEOUS q= NON- FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) FUSIBLE SAFETY SWITCH, SIZE AS NOTED (AMP RATING /POLES) MOTOR CONNECTION UH UNIT HEATER CONNECTION DUCT HEATER CONNECTION O JUNCTION BOX s PANELBOARD - FLUSH MOUNTED PANELBOARD - SURFACE MOUNTED WG A-P MEDICAL GAS ALARM PANEL cR CARD READER WIRING CONCEALED CONDUIT CONDUIT CONCEALED IN FLOOR OR BELOW GRADE HOMERUN TO PANELBOARD - NUMBER OF PHASE CONDUCTORS IN MINIMUM 314 CONDUIT UNLESS NOTED OTHERWISE NOTES: ---,� 1. ONE NEUTRAL CONDUCTOR FOR EACH PHASE CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 2. ONE INSULATED GREEN GROUNDING CONDUCTOR, ALTHOUGH NOT INDICATED, SHALL BE INCLUDED IN EACH RACEWAY UNLESS OTHERWISE NOTED. 3. HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CONDUCTORS (ONE PER PHASE) PLUS THREE (3) NEUTRAL CONDUCTORS AND ONE (1) GROUND CONDUCTOR IN EACH CONDUIT. 4. MULTI -WIRE BRANCH CIRCUITS THAT SHARE A COMMON NEUTRAL SHALL NOT BE PERMITTED FOR INDIVIDUAL LINE -TO- NEUTRAL LOADS. 5. EACH CIRCUIT (PHASE AND NEUTRAL CONDUCTORS) SHALL BE GROUPED TOGETHER USING CABLE TIES AT THE PANELBOARD AND ALL JUNCTION BOXES, PULL BOXES AND ALL OTHER LOCATIONS WHERE TERMINATIONS, CONNECTIONS OR SPLICES ARE MADE. 6. ALL CONDUCTORS SHALL BE *12 AWG UNLESS OTHERWISE NOTED. ALL WORK SHALL COMPLY WITH THE 2008 EDITION OF THE NEC. DRAWING INDEX SHEET NUMBER :SHEET TITLE EO.0 ELECTRICAL LEGENDS, SCHEDULES,AND DRAWING INDEX E1.1 PARTIAL FIRST FLOOR - DEMOLITION - ELECTRICAL E1.2 PARTIAL FIRST FLOOR REFERENCE PLAN - ELECTRICAL E2.1 PARTIAL FIRST FLOOR - NEW CONSTRUCTION - LIGHTING E3.1 PARTIAL FIRST FLOOR - NEW CONSTRUCTION - POWER & SYSTEMS E4.1 PARTIAL ELECTRICAL RISER DIAGRAM & PANEL SCHEDULES E5.1 ELECTRICAL STUDIES E6.1 ELECTRICAL SPECIFICATIONS Archil.60 lre Ein ineeririy Manning A" interior Design Landsca�eArshitecture p 2s0', Sock(. Eayshore Driva'lMh Floor Miami, Florida 33133 E (305) 859 -2050 Fax (305) 860 -3700 MEP ENGINEER: 2aSmith Seckman Reid, Inc. 600 West Hillsboro, Suite 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421-1466 www.ssr- inc.com Firm Certification - EB- 0000857 John E. Moulder PE - 33200 Michael A. Steward PE - 65701 SSR JOB # 1032062.0 7 C W/O PERMIT SUBMITTAL CD PHASE REVISIONS: PROJECT NAME: SOUTH MIAMI HOSPITAL EAST TOWER FIBROID CENTER B PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 KEY PLAN COMM. NO. 40062.100 SCALE: DATE: JUNE 30.2010 DRAWN: A CHECKED: CADD FILE: DRAWING TITLE: ELECTRICAL LEGEND SCHEDULES AND DRAWING INDEX SHEET NO. EO.0