Loading...
10-640-008LISTED TRUSSES AT 10^ D.C. LISTED ROOF TRUSS DESIGN LOADS: LIVE LOAD 30 PSF TOP CHORD DEAD LOAD 10 PSF TOP CHORD DEAD LOAD 10 PSF BOTTOM CHORD RIM MEMBER 2x4 SYP #2 W|N. THERMOPLASTIC SINGLE PLY ROOF COVER|NOVNTH ASTM D4434 OR CGS637-CP-54W RBERTIQHT BY MULE-HIDE PRODUCTS SPACE PLY LAPS 51^ O.C. WITH 4~ MINIMUM OVERLAPS FASTEN WITH FTR MAGNUM FASTENERS AT ALL EDGES AND PLY LAPS AT THE FOLLOWING SPACINGS 4" O.C. WITHIN 4' OF THE BUILDING CORNERS 8^ O� WITHIN 4' OF ALL OTHER EDGES .. ' ' SITE INSTALLED 3/8'' X 5^ LAG SCREWS � D.C. ELSEWHERE ' � � " '' STAGGERED FROM SIDE TO SIDE - - - ----� - - ^ � LAYERS 3/4 18 TEC L�w ROOF COVERING OVER 3/4^ PLYWOOD x o."v��n�u ,nv� o.u� .* ".u� RATED SHEATHING, MINIMUM EXp-1 32/18 RIDGE BEAM BOTH UNITS AT 16 0.C, MAXIMUM. LAG SCREWS SEE SPAN CHART |N MUST PENETRATE 1 J/4^ MINIMUM INTO SEE C0NST PK0 FOR OTHER APPROVED MATERIALS ' SEE SHEATHING DETAIL, APPROVED STRUCTURAL ADJACENT MODULE R|DgEBEAW OR PACKAGE TRUSS. \ \ ..\ / \ \ 2u\ �24 . RIDGE BEAM 3 LAYERS 3/4"x 24" TEC LAM LVL RIDGE BEAM BOTH UNITS SEE SPAN CHART IN APPROVED STRUCTURAL PACKAGE RIDGE BEAM MUST BE CONTINUOUS OVER CLEAR SPAN BEAMS SUPPORTED BY ENDWALL COLUMNS MUST EXTEND CONTINUOUS OVER COLUMNS TO EXTERIOR FACE OF ENDWALL, MULTIPLE UNITS ARE TO BE CLUED & NAILED TOGETHER TO ACT AS ONE UNIT, INSTALL 2X4 X DEPTH OF BEAM SPF #3 BEARING STIFFENER OVER SUPPORT COLUMNS WHEN SPECIFIED ON FLOOR PLAN; FASTEN THE FACE OF STIFFENER TO THE RIDGE BEAM WITH 100% GLUE COVERAGE AND SEE STRUCTURAL PKG FOR ALTERNATE RIDGE BEAM CONST, SEE STRUCTURAL PK0, FOR--/ R- 19 KRAFTBACK DUCT SPECIFICATIONS, ROOF INSULATION FASTEN RIDGE BEAM TO EACH TRUSS WITH NO LESS THAN 6-15 CA, STAPLES WITH 1' PENETRATION INTO TRUSS KING POST OR EQUIVALENT FASTENING. DOUBLE TOP PLATE 2X4 SPF #2 NOTE INSTALL A J 1/2" PLYWOOD STRIP AT TOP PLATE THE SAME THICKNESS AS THE CEILING FINISH SEE STRUCTURAL PACKAGE FOR FLOOR DECKING T--2x SYP #2 FLOOR J0|9T3. SEE \ 2X5 @16" O.C.,3EE SHEET #1 FOR 100# LOAD AREAS WlOx8.5 |-BEAM INSTALL (1) 3/8^XJ^ LAG SCREW INTO FRAME CLIP, TYP, EACH FLOOR JOIST 8.4 SQUARE FEET NET FREE AREA OF ATTIC VENTILATION TO BE PROVIDED BY ROOF AND/0R GABLE YENTS, TRUSS DESIGN UNIVERSAL #SF05961 1/4' MIN SLOPE PER FOOT 20 *INSTALL STUDS 12" O,C. WITHIN 4'-0" FROM ENDS OF BUILDING TO ACCOMMODATE END ZONE REQUIREMENTS 48" TYPICAL T&Q JOINT (TYPICAL) PER PLAN SITE INSTALLED J/O^ LAC SCREWS STAGGERED FROM 'SIDE TO SIDE AT 48° D.C. MAX. LAG SCREWS MUST PENETRATE 1 3/4^ MINIMUM INTO ADJACENT MODULE RIM JOIST. , t /�[}T|/lN�| T��U��{� �/�[� F\�Fl[ �`/�UNTV SHINGLES �// //`//�/`�_ //`�/`�`� FOR �//`�/�- �/����/x / / LISTED TRUSSES 0 10" O.C. MAX. LISTED ROOF TRUSS DESIGN LOADS: LIVE LOAD 30 PFS TOP CHORD DEAD LOAD 10 pSF TOP CHORD ULAU~'`^ '^^~ ^~ ~~- ~~--^'' ~'^R~ RIM MEMBER 2x4 SYP #2 W|N. DADE COUNTY APPROVED SHINGLES OVER 5/8~ PLYWOOD RATEDED�SHEATH|NG. MINIMUM EXP-1 20/0 SEE ROOF QWF'Armu(' nPTxx EXTERIOR WALL FINISH, EXTERIOR WALL STRUCTURAL BRACING S|DEWALLS: BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF A 4` MINIMUM WIDTH SHEET EXTENDING CONTINUOUSLY FROM TOP TO BOTTOM PLATE WITH ALL SHEATHING EDGES EXTENDING 3/4^ MINIMUM OVER 2" NOMINAL LUMBER OF THE SAME SIZE AND GRADE AS EXTERIOR WALL FRAMING. BRACING SHALL BE LOCATED AS CLOSE TO EACH CORNER OF BUILDING AS P0SS|BLE, BRACING MATERIAL: 5/8'^ APA RATED SHEATHING EXP, 1.-2 EXT OR 5/8" APA RATED SIDING EXT. FASTENED WITH Dd GALVANIZED COMMON OR BOX AT 4" O.C. EDGES, 8" O.C. FIELD. ENDWALLS: BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF A 4' MINIMUM WIDTH SHEET EXTENDING CONTINUOUSLY FROM TOP TO BOTTOM PLATE WITH ALL SHEATHING EDGES EXTENDING 3/4^ MINIMUM OVER 2" NOMINAL LUMBER OF THE SAN[ SIZE AND GRADE AS EXTERIOR WALL FR4W|NG, BRACING SHALL BE LOCATED AS CLOSE TO EACH CORNER OF BUILDING AS POSSIBLE. BRACING MATERIAL: 5/8~ APA RATED SHEATHING EXP, 1.-2 EXT OR 5/8^ APA RATED 3|0N8 EXT, FASTENED WITH 8d GALVANIZED COMMON OR BOX AT 4^ D.C. EDG[S, 8^ D.C. FIELD. O[lOA FRAMING NUN[)0Vy FRAMING HEADERS 2-2x4 SYP #2 PLATE YP #2 )LE STUDS YP #2 5" O.C. 20" 26 GA, x 1-1/2" STEEL STRAP FROM TRUSS TO WALL STUD @ 16" O,C. WITH 6-14 GA. X 1" STAPLES PER STRAP ASTM A36, YIELD STRENGTH = 36 KSI, AND COMPLY WITH AISC END. (TYPICAL SIDEWALLS) DOUBLE STRAPPING AT EACH STUD FOR FLOOR LOAD 10 PSF DL FIRST 4' IN FROM EACH CORNER, 5/16" = 60 KSI MINIMUM TRUSSES THAT DO NOT FALL DIRECTLY dz/ OVER WALL STUDS SHALL BE STRAPPED TO WIND LOAD 146 MPH TOP PLATE AND TOP PLATE SHALL BE 3, SEE FOUNDATION PLAN FOR PIER AND TIE DOWN STRAPPING STRAPED TO NEAREST AJACENT WALL STUD WITH EQUIVALENT STRAPPING ROOF' 10 PSF DL 4. SEE FBC TABLE 2324.1 FOR FASTENING REQUIREMENTS NOT OUTLINED ON THIS PACE. 5, ALL STRAPS SHALL BE GALVANIZED WITH A CURRENT PRODUCT WINDOW HEADER, SEE SPAN CHART FOR SPECS TYP. WINDOW, SEE SHEET #2 FOR SPECS WALL INTERIOR FINISH, SEE SHEET #1 FOR SPECS. TYP. WINDOW SILL 2X4 SYP#2 96" WALL HEIGHT TYP UNLESS NOTE ON SHEET #2 SPECIFIES OTHERWISE SEE CONSTRUCTION PACKAGE FOR CONST, R-11 KRAFTBACK WALL INSULATION BOTTOM PLATE R-11 UNFACED FLOOR INSULATION 26 GA. x 1-1/2" STEEL STRAP FROM WALL STUD TO FLOOR JOIST AT OPENING STUDS AND INSTALL DOUBLE STRAPPING AT EACH STUD FOR FIRST 4' IN FROM EACH CORNER, INSTALL (3) 3/8"XY LAG SCREWS FROM TOP FLANGE OF OUTRIGGER INTO FLOOR, AND/OR RIM JOIST ABOVE (TYP, EACH OUTRIGGER) OUTRIGGER AND CROSSMEMBER INSTALLED IN ACCORDANCE WITH STATE PACKAGE THERMOPLASTIC SINGLE PLY ROOF COVER|NOVNTH ASTM D4434 OR CGS637-CP-54W RBERTIQHT BY MULE-HIDE PRODUCTS SPACE PLY LAPS 51^ O.C. WITH 4~ MINIMUM OVERLAPS FASTEN WITH FTR MAGNUM FASTENERS AT ALL EDGES AND PLY LAPS AT THE FOLLOWING SPACINGS 4" O.C. WITHIN 4' OF THE BUILDING CORNERS 8^ O� WITHIN 4' OF ALL OTHER EDGES .. ' ' SITE INSTALLED 3/8'' X 5^ LAG SCREWS � D.C. ELSEWHERE ' � � " '' STAGGERED FROM SIDE TO SIDE - - - ----� - - ^ � LAYERS 3/4 18 TEC L�w ROOF COVERING OVER 3/4^ PLYWOOD x o."v��n�u ,nv� o.u� .* ".u� RATED SHEATHING, MINIMUM EXp-1 32/18 RIDGE BEAM BOTH UNITS AT 16 0.C, MAXIMUM. LAG SCREWS SEE SPAN CHART |N MUST PENETRATE 1 J/4^ MINIMUM INTO SEE C0NST PK0 FOR OTHER APPROVED MATERIALS ' SEE SHEATHING DETAIL, APPROVED STRUCTURAL ADJACENT MODULE R|DgEBEAW OR PACKAGE TRUSS. \ \ ..\ / \ \ 2u\ �24 . RIDGE BEAM 3 LAYERS 3/4"x 24" TEC LAM LVL RIDGE BEAM BOTH UNITS SEE SPAN CHART IN APPROVED STRUCTURAL PACKAGE RIDGE BEAM MUST BE CONTINUOUS OVER CLEAR SPAN BEAMS SUPPORTED BY ENDWALL COLUMNS MUST EXTEND CONTINUOUS OVER COLUMNS TO EXTERIOR FACE OF ENDWALL, MULTIPLE UNITS ARE TO BE CLUED & NAILED TOGETHER TO ACT AS ONE UNIT, INSTALL 2X4 X DEPTH OF BEAM SPF #3 BEARING STIFFENER OVER SUPPORT COLUMNS WHEN SPECIFIED ON FLOOR PLAN; FASTEN THE FACE OF STIFFENER TO THE RIDGE BEAM WITH 100% GLUE COVERAGE AND SEE STRUCTURAL PKG FOR ALTERNATE RIDGE BEAM CONST, SEE STRUCTURAL PK0, FOR--/ R- 19 KRAFTBACK DUCT SPECIFICATIONS, ROOF INSULATION FASTEN RIDGE BEAM TO EACH TRUSS WITH NO LESS THAN 6-15 CA, STAPLES WITH 1' PENETRATION INTO TRUSS KING POST OR EQUIVALENT FASTENING. DOUBLE TOP PLATE 2X4 SPF #2 NOTE INSTALL A J 1/2" PLYWOOD STRIP AT TOP PLATE THE SAME THICKNESS AS THE CEILING FINISH SEE STRUCTURAL PACKAGE FOR FLOOR DECKING T--2x SYP #2 FLOOR J0|9T3. SEE \ 2X5 @16" O.C.,3EE SHEET #1 FOR 100# LOAD AREAS WlOx8.5 |-BEAM INSTALL (1) 3/8^XJ^ LAG SCREW INTO FRAME CLIP, TYP, EACH FLOOR JOIST 8.4 SQUARE FEET NET FREE AREA OF ATTIC VENTILATION TO BE PROVIDED BY ROOF AND/0R GABLE YENTS, TRUSS DESIGN UNIVERSAL #SF05961 1/4' MIN SLOPE PER FOOT 20 *INSTALL STUDS 12" O,C. WITHIN 4'-0" FROM ENDS OF BUILDING TO ACCOMMODATE END ZONE REQUIREMENTS 48" TYPICAL T&Q JOINT (TYPICAL) PER PLAN SITE INSTALLED J/O^ LAC SCREWS STAGGERED FROM 'SIDE TO SIDE AT 48° D.C. MAX. LAG SCREWS MUST PENETRATE 1 3/4^ MINIMUM INTO ADJACENT MODULE RIM JOIST. , t /�[}T|/lN�| T��U��{� �/�[� F\�Fl[ �`/�UNTV SHINGLES �// //`//�/`�_ //`�/`�`� FOR �//`�/�- �/����/x / / LISTED TRUSSES 0 10" O.C. MAX. LISTED ROOF TRUSS DESIGN LOADS: LIVE LOAD 30 PFS TOP CHORD DEAD LOAD 10 pSF TOP CHORD ULAU~'`^ '^^~ ^~ ~~- ~~--^'' ~'^R~ RIM MEMBER 2x4 SYP #2 W|N. DADE COUNTY APPROVED SHINGLES OVER 5/8~ PLYWOOD RATEDED�SHEATH|NG. MINIMUM EXP-1 20/0 SEE ROOF QWF'Armu(' nPTxx EXTERIOR WALL FINISH, EXTERIOR WALL STRUCTURAL BRACING S|DEWALLS: BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF A 4` MINIMUM WIDTH SHEET EXTENDING CONTINUOUSLY FROM TOP TO BOTTOM PLATE WITH ALL SHEATHING EDGES EXTENDING 3/4^ MINIMUM OVER 2" NOMINAL LUMBER OF THE SAME SIZE AND GRADE AS EXTERIOR WALL FRAMING. BRACING SHALL BE LOCATED AS CLOSE TO EACH CORNER OF BUILDING AS P0SS|BLE, BRACING MATERIAL: 5/8'^ APA RATED SHEATHING EXP, 1.-2 EXT OR 5/8" APA RATED SIDING EXT. FASTENED WITH Dd GALVANIZED COMMON OR BOX AT 4" O.C. EDGES, 8" O.C. FIELD. ENDWALLS: BRACING INSTALLATION: STRUCTURAL SHEATHING SHALL CONSIST OF A 4' MINIMUM WIDTH SHEET EXTENDING CONTINUOUSLY FROM TOP TO BOTTOM PLATE WITH ALL SHEATHING EDGES EXTENDING 3/4^ MINIMUM OVER 2" NOMINAL LUMBER OF THE SAN[ SIZE AND GRADE AS EXTERIOR WALL FR4W|NG, BRACING SHALL BE LOCATED AS CLOSE TO EACH CORNER OF BUILDING AS POSSIBLE. BRACING MATERIAL: 5/8~ APA RATED SHEATHING EXP, 1.-2 EXT OR 5/8^ APA RATED 3|0N8 EXT, FASTENED WITH 8d GALVANIZED COMMON OR BOX AT 4^ D.C. EDG[S, 8^ D.C. FIELD. O[lOA FRAMING NUN[)0Vy FRAMING HEADERS 2-2x4 SYP #2 PLATE YP #2 )LE STUDS YP #2 5" O.C. ~-� ~-~ ...-- �. .~` DUCT �PEC1RCA�ONS. SEE SHEET #1 FOR CEILING INT. FINISH ROOF INSUL�TION :1 -� | � 2. _� -=��=-1 1/4" CROS3W[MBER SECTION INSTALL D|ApHRNN BLOCKING WITHIN 4,_0, FROM END-WALL! WITH 2X SYP#2 LUMBER LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1879 CONSTRUCTION CODES AND ADHERE T0 THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY B ALLOWABLE # OF FLOORS 1 WIND VELOCITY 146 FIRE RATING OF EXTERIOR WALLS 0 PLAN NO. WDSUO8y54 ALLOWABLE FLOOR LOAD 00 APPROVAL DATE 06/02/2010 MANUFACTURER PER DCA LETTER APPROVED FOR HIGH VELOCITY WIND ZONE YES M.D.S. FULL LENGTH 3/15^ FILLET WELDS ONE SIDE OF ALL FLANGES AND WEBS AT ALL OUTRIGGERS AND CROSSWEMB[RS. 1-1/2" 12 GA. OUTTRIGGER r 1-l/2~ ---^- 7' 12 GA. CR0SSWEM8ER. (T0 BE LOCATED OPPOSITE 1-1/2^ 0UTR|CQER AS SHOWN) OUTRIGGER SECTION FRAME DETAIL Lj cn STAGGER JOINTS 48~ O.C. ENDWALL 3/4' RATED SHEATU|NG, PLYWOOD TO BE FASTENED TO TRUSSES WITH #10d NAILS AT 4^ O.C. AT 4' FROM END-WALLS. WITH #106 NAILS AT 8'' O.C. AT ALL OTHER AREAS SEE STRUCTURAL PKG FOR ALTERNATE SHEATHING METHODS ROOF SHEATHING DETAIL SIZE CODE TYPE PER PRINT 2001 FBC N � � ��_ GENERAL CROSS SECTION NOTES DESIGN CRITERIA 1, UNLESS OTHERWISE SPECIFIED, ALL STEEL MUST COMPLY WITH ASTM A36, YIELD STRENGTH = 36 KSI, AND COMPLY WITH AISC FLOOR LOAD 50 PSF LL 2. ALL LAG SCREWS MUST COMPLY WITH ANSI/ASME B18.2.1 FLOOR LOAD 10 PSF DL 5/16" = 60 KSI MINIMUM WIND LOAD 146 MPH 3, SEE FOUNDATION PLAN FOR PIER AND TIE DOWN STRAPPING ROOF; 30 PSF LL LOCATIONS, ORIENTATIONS, AND SPECIFICATIONS. ROOF' 10 PSF DL 4. SEE FBC TABLE 2324.1 FOR FASTENING REQUIREMENTS NOT OUTLINED ON THIS PACE. 5, ALL STRAPS SHALL BE GALVANIZED WITH A CURRENT PRODUCT CONTROL APPROVAL ~-� ~-~ ...-- �. .~` DUCT �PEC1RCA�ONS. SEE SHEET #1 FOR CEILING INT. FINISH ROOF INSUL�TION :1 -� | � 2. _� -=��=-1 1/4" CROS3W[MBER SECTION INSTALL D|ApHRNN BLOCKING WITHIN 4,_0, FROM END-WALL! WITH 2X SYP#2 LUMBER LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1879 CONSTRUCTION CODES AND ADHERE T0 THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY B ALLOWABLE # OF FLOORS 1 WIND VELOCITY 146 FIRE RATING OF EXTERIOR WALLS 0 PLAN NO. WDSUO8y54 ALLOWABLE FLOOR LOAD 00 APPROVAL DATE 06/02/2010 MANUFACTURER PER DCA LETTER APPROVED FOR HIGH VELOCITY WIND ZONE YES M.D.S. FULL LENGTH 3/15^ FILLET WELDS ONE SIDE OF ALL FLANGES AND WEBS AT ALL OUTRIGGERS AND CROSSWEMB[RS. 1-1/2" 12 GA. OUTTRIGGER r 1-l/2~ ---^- 7' 12 GA. CR0SSWEM8ER. (T0 BE LOCATED OPPOSITE 1-1/2^ 0UTR|CQER AS SHOWN) OUTRIGGER SECTION FRAME DETAIL Lj cn STAGGER JOINTS 48~ O.C. ENDWALL 3/4' RATED SHEATU|NG, PLYWOOD TO BE FASTENED TO TRUSSES WITH #10d NAILS AT 4^ O.C. AT 4' FROM END-WALLS. WITH #106 NAILS AT 8'' O.C. AT ALL OTHER AREAS SEE STRUCTURAL PKG FOR ALTERNATE SHEATHING METHODS ROOF SHEATHING DETAIL SIZE CODE TYPE PER PRINT 2001 FBC N � � ��_