Loading...
10-640-007i r' f i-y 0 I 13' -3 3/4" 56' -0" 52' -0" 54 ° -0" 54'-0" Ln L, 00 N I 56' -0" 52' -0" r 13 ° -3 3/4" 60 ° -0" 14' -0 3/4' 1o' -o" 10 ° -0" 46' -8 1/4" 32' -7 1/2- 22 ° -7 1/2" 42' -8 3/4" 36' -0 3/4" 26 ° -8 3/4" 17 °--4 3/4" d-" 7 F F— d' 3680 2453VS 2453VS 2 EXIT s t 42 ° -8" 38' -8" 3680 3680 0 36` -8" cc w M p— 3680 E 3680 3680 I. v 44' -0" F71 F71 38' -0" 40 ° -0" 36' -0" 30' -8" v � ry 1 20'-0' L26'-8 3/4" 22'-7 1/2" i 4' -3 1/2- 8` -4" 12. -7 1/2- 148--4" ®--- 8'-10 1/2" 3680 IL I L4 3680 v i LlIw0 3/4'° ' 12�' -7�1 /2" 10 ° -0" I/ 3" VTR /I o C1� rm � 1t V -1 1 /4" 3 TON HVAC INSTALLED PER MFG'R, SPEC. W /10 KW HEAT STRIP 1005 CFM @ .5 IWC ESP WITH FRESH AIR INTAKE 240V 1 0 `- -CKT #1A &2A 28'° X 14" R/A GRILLE THRU WALL 3 TON HVAC INSTALLED PER MFG °R. SPEC, W /10 KW HEAT STRIP 1005 CFM @ .5 IWC ESP WITH FRESH AIR INTAKE 240V 1 0 CKT #1B &28 28" X 14°' R/A GRILLE THRU WALL GFI rs 100 AMP ELECT. PANEL 120V/240V 1 PHASE (TYP) L'6-_8 3/4" 12 ° -7 1/2" i J 7" I I LAV 3., 1 1/2" 3„ W.C. N.T,S. TTO WASTE TERM, AUTOVENT I SINK 1 1 /2" 1 1/2" i COLUMN /STRAPPING SCHEDULE BREAKER (AMPS) (2) 2x4 SPF #2 THIS HALF 0 (2 ) 2x4 SPF #2 EACH HALF { 3) 2x4 SPF #2 THIS HALF O (3) 2x4 SPF #2 EACH HALF O{4) 2x4 SPF #2 THIS HALF (4) 2x4 SPF #2 EACH HALF (5) 2x4 SPF #2 THIS HALF (5) EXIT HALF NOTES: 4A —B LIGHTS 1. ALL COLUMN STUDS SHALL BE GLUE /NAILED TOGETHER 1P PVA GLUE WITH 100% COVERAGE SHALL BE USED _y 2. INSTALL 2 STEEL STRAPS AT EACH STUD OF EACH COLUMN. 20A 3680 BORED. 2453VS P. 43' -1 1 /2" 36' -0 3/4" 46 ° ° -7--"3 /4" rV 1 /2" .442'- 433/4" 10 32' -7 1 9'-9 1/4- v � ry 1 20'-0' L26'-8 3/4" 22'-7 1/2" i 4' -3 1/2- 8` -4" 12. -7 1/2- 148--4" ®--- 8'-10 1/2" 3680 IL I L4 3680 v i LlIw0 3/4'° ' 12�' -7�1 /2" 10 ° -0" I/ 3" VTR /I o C1� rm � 1t V -1 1 /4" 3 TON HVAC INSTALLED PER MFG'R, SPEC. W /10 KW HEAT STRIP 1005 CFM @ .5 IWC ESP WITH FRESH AIR INTAKE 240V 1 0 `- -CKT #1A &2A 28'° X 14" R/A GRILLE THRU WALL 3 TON HVAC INSTALLED PER MFG °R. SPEC, W /10 KW HEAT STRIP 1005 CFM @ .5 IWC ESP WITH FRESH AIR INTAKE 240V 1 0 CKT #1B &28 28" X 14°' R/A GRILLE THRU WALL GFI rs 100 AMP ELECT. PANEL 120V/240V 1 PHASE (TYP) L'6-_8 3/4" 12 ° -7 1/2" i J 7" I I LAV 3., 1 1/2" 3„ W.C. N.T,S. TTO WASTE TERM, AUTOVENT I SINK 1 1 /2" 1 1/2" i COLUMN /STRAPPING SCHEDULE BREAKER (AMPS) (2) 2x4 SPF #2 THIS HALF 0 (2 ) 2x4 SPF #2 EACH HALF { 3) 2x4 SPF #2 THIS HALF O (3) 2x4 SPF #2 EACH HALF O{4) 2x4 SPF #2 THIS HALF (4) 2x4 SPF #2 EACH HALF (5) 2x4 SPF #2 THIS HALF (5) 2x4 SPF #2 EACH HALF NOTES: 4A —B LIGHTS 1. ALL COLUMN STUDS SHALL BE GLUE /NAILED TOGETHER 1P PVA GLUE WITH 100% COVERAGE SHALL BE USED _y 2. INSTALL 2 STEEL STRAPS AT EACH STUD OF EACH COLUMN. 20A 3. COLUMN STUDS SHALL NOT BE NOTCHED OR BORED. 6A —B 4, ALL STEEL STRAPS AT SUPPORT COLUMN LOCATIONS RECEPTS SHALL BE 1 1/2" X 30 GA. WITH 14, 16 GA.X 7 16" CROWN 1P 1 1/8" LONG STAPLES EACH DOUBLE STRAP END OR EQUAL FROM RIDGE BEAM TO COLUMN AND COLUMN TO FLOOR UNLESS OTHERWISE 20A NOTED. 12 -2 8A--B LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1979 CONSTRUCTION CODES AND ADHERE TO THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY B ALLOWABLE # OF FLOORS 1 WIND VELOCITY 146 FIRE RATING OF EXTERIOR WALLS 0 PLAN NQ. MOS006954 ALLOWABLE FLOOR LOAD 50/100 APPROVAL DATE 06/02/2010 MANUFACTURER PER DCA LETTER APPROVED FOR HIGH VELOCITY WIND ZONE YES M.D.S. Lur-1 ModSpacit SYMBOLS: DUPLEX RECEPT @ 16" AFF DUPLEX RECEPT @ 42" AFF RECEPT 220 VOLT > FLOOR RECEPTACLE _ SWITCH �3 3 WAY SWITCH -- PHONE JACK @ 16" AFF FLOOR PHONE JACK �T THERMOSTAT INCANDESCENT LIGHT 60W. MAX. —Q—W, p. WATER PROOF PORCH LIGHT 60W. MAX. FLUORESCENT FIXTURE 87.6 W. MAX. RECESSED FLUORESCENT 87,6 W. MAX. ® JUNCTION BOX — ® JUNCTION BOX ® 100 CFM EXHAUST FAN EXHAUST FAN WITH LIGHT _ EMERGENCY LIGHT J BOX FOR MANUAL PULL STATION & BELL EP J BOX FOR MANUAL PULL STATION ®p 12 "x12" SUPPLY AIR REGISTER qp 12 "x12" RETURN AIR GRILLE IN 8x18 JUMP INTO PLENUM ELECTRIC SCHEDULE CIRCUIT # NOMENCLATURE BREAKER (AMPS) WIRE SI2 CU. NM. W/C 1 & 2 HVAC SIZED PER MFR. SPECS, 3B WATER HEATER w 1P 12 -2 4A —B LIGHTS RECEPTS 20A 1P 12 -2 _y LIGHTS RECEPTS 20A 1P 12 -2 LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1979 CONSTRUCTION CODES AND ADHERE TO THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY B ALLOWABLE # OF FLOORS 1 WIND VELOCITY 146 FIRE RATING OF EXTERIOR WALLS 0 PLAN NQ. MOS006954 ALLOWABLE FLOOR LOAD 50/100 APPROVAL DATE 06/02/2010 MANUFACTURER PER DCA LETTER APPROVED FOR HIGH VELOCITY WIND ZONE YES M.D.S. Lur-1 ModSpacit SYMBOLS: DUPLEX RECEPT @ 16" AFF DUPLEX RECEPT @ 42" AFF RECEPT 220 VOLT > FLOOR RECEPTACLE _ SWITCH �3 3 WAY SWITCH -- PHONE JACK @ 16" AFF FLOOR PHONE JACK �T THERMOSTAT INCANDESCENT LIGHT 60W. MAX. —Q—W, p. WATER PROOF PORCH LIGHT 60W. MAX. FLUORESCENT FIXTURE 87.6 W. MAX. RECESSED FLUORESCENT 87,6 W. MAX. ® JUNCTION BOX — ® JUNCTION BOX ® 100 CFM EXHAUST FAN EXHAUST FAN WITH LIGHT _ EMERGENCY LIGHT J BOX FOR MANUAL PULL STATION & BELL EP J BOX FOR MANUAL PULL STATION ®p 12 "x12" SUPPLY AIR REGISTER qp 12 "x12" RETURN AIR GRILLE IN 8x18 JUMP INTO PLENUM ELECTRIC SCHEDULE CIRCUIT # NOMENCLATURE BREAKER (AMPS) WIRE SI2 CU. NM. W/C 1 & 2 HVAC SIZED PER MFR. SPECS, 3B WATER HEATER 20A 1P 12 -2 4A —B LIGHTS RECEPTS 20A 1P 12 -2 5A —B LIGHTS RECEPTS 20A 1P 12 -2 6A —B LIGHTS RECEPTS 20A 1P 12 -2 7A —B LIGHTS RECEPTS 20A 1P 12 -2 8A--B LIGHTS RECEPTS 20A 1P 12 -2 9A —B LIGHTS RECEPTS 20A 1P 12--2 ALL PORTABLE APPLIANCES, INCLUDING W /H, TO HAVE DISCONNECT IF NOT WITHIN VIEW OF ELECTRIC PANEL. PANEL "A" KVA GENERAL LIGHTING .0035 KW SF x 607 SF x 1.25 2.66 13 RECEPTS @ 180 VA /1000 2.34 HVAC 10.9 1 FAN @ .3 KW x 1.25 .75 TOTAL 16.6A TOTAL /240x1000 69.17 INSTALL 100 AMP PANEL 120/240V 10 PANEL "B" KVA GENERAL LIGHTING .0035 KW SF x 607 SF x 1.25 2.66 10 RECEPTS @ 180 VA /1000 1.8 HVAC 10.9 TOTAL 14.46 TOTAL /240x1000 60.25 INSTALL 100 AMP PANEL 120/240V 10 J N A. Z Al i 3637 4TH STREET NORTH SAINT PETERSBURG, FLORIDA 33704 A IT T LICENSE #AR- 0005065 M.D.S. 2730 12TH STREET SOUTH MDS006954 LSTINLISTING �p SAINT PETERSBURG, FLORIDA 33705 G AGENCY 1 PHONE #813- 898 -6004 DATE SCALE QUOTE SER. NO. 06/02/2010 —NTS— MDS006954 02, , 2010 SIZE CODE TYPE USE CHM(EO BY [REV. APP V L # PAGE PER PRINT 2001 FBC VI B MDS JOD 0 5s54 2 OF 4 $ �