10-640-006GENERAL NOTES: 2001 FBC, 2000 NFPA101
1. HANDICAP ACCESS TO BUILDING IS DESIGNED AND FIELD BUILT BY OTHERS AND
SUBJECT TO LOCAL JURISDICTION, ,
2. ALL DOORS SHALL BE OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A
KEY, TOOL, SPECIAL KNOWLEDGE OR EFFORT. MANUALLY OPERATED FLUSH BOLTS
OR SURFACE BOLTS SHALL NOT BE USED.
3. ALL GLAZING WITHIN A 24 INCH ARC OF DOORS, WHOSE BOTTOM EDGE IS LESS THAN
60 INCHES ABOVE THE FLOOR, AND ALL GLAZING IN DOORS SHALL BE SAFETY,
TEMPERED OR ACRYLIC PLASTIC SHEET.
4. FLOOR DESIGN LIVE LOAD -100 PSF CORRIDORS, LOBBY, 50 PSF ELSEWHERE
5. MAXIMUM WIND SPEED - 146 MPH
6. SEISMIC PERFORMANCE CATAGORY -A
7. OCCUPANCY IS BUSINESS
8, OCCUPANT LOAD IS BASED ON 1 PERSON PER 100 SQUARE FEET OF FLOOR AREA FOR EGRESS
9, ALL STEEL STRAPS REFERENCED ON FLOOR PLAN SHALL BE 1.5 INCH x 30 GA. WITH
(7)- 16 GA. x 7/16 INCH CROWN x 1 INCH PENETRATION STAPLES EACH END OF STRAP
(OR EQUIVALENT) FROM RIDGE BEAM TO COLUMN AND COLUMN TO FLOOR.
10, PORTABLE FIRE EXTINGUISHERS) PER N.F.P.A. -10 INSTALLED BY OTHERS ON
SITE, AND SUBJECT TO LOCAL JURISDICTION,
11, MINIMUM CORRIDOR WIDTH IS 44 INCHES.
12, MINIMUM CORRIDOR FINISH IS CLASS A (GYPSUM).
ELECTRICAL NOTES:1999 NEC
1, ALL CIRCUITS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH THE
APPROPRIATE ARTICLES OF THE NATIONAL ELECTRIC CODE (N,E.C.),
ALL BOXES IN RATED PARTITIONS SHALL BE METAL BOXES.
2. WHEN LIGHT FIXTURES ARE INSTALLED IN CLOSETS, THEY SHALL BE SURFACE
MOUNTED OR RECESSED. INCANDESCENT FIXTURES SHALL HAVE COMPLETELY
ENCLOSED LAMPS. SURFACE MOUNTED INCANDESCENT FIXTURES SHALL HAVE
A MINIMUM CLEARANCE OF 12 INCHES AND ALL OTHER FIXTURES SHALL HAVE
A MINIMUM CLEARANCE OF 6 INCHES FROM "STORAGE AREA" AS DEFINED BY
N.E.C. 410- -8(a).
3, WHEN WATER HEATERS ARE INSTALLED THEY SHALL BE PROVIDED WITH READILY
ACCESSIBLE DISCONNECTS ADJACENT TO THE WATER HEATER(S) SERVED. THE
BRANCH CIRCUIT SWITCH OR CIRCUIT BREAKER SHALL BE PERMITTED TO SERVE
AS THE DISCONNECTING MEANS ONLY WHERE THE SWITCH OR CIRCUIT BREAKER
IS WITHIN SIGHT FROM THE WATER HEATER OR IS CAPABLE OF BEING LOCKED
IN THE OPEN POSITION.
4. HVAC EQUIPMENT SHALL BE PROVIDED WITH READILY ACCESSIBLE DISCONNECTS
ADJACENT TO THE EQUIPMENT SERVED. A UNIT SWITCH WITH A MARKED "OFF"
POSITION THAT IS A PART OF THE HVAC EQUIPMENT AND DISCONNECTS ALL
UNGROUNDED CONDUCTORS SHALL BE PERMITTED AS THE DISCONNECTING
MEANS INHERE OTHER DISCONNECTING MEANS ARE ALSO PROVIDED BY A
READILY ACCESSIBLE CIRCUIT BREAKER,
5. PRIOR TO ENERGIZING THE ELECTRICAL SYSTEM THE INTERRUPTING RATING
OF THE MAIN BREAKER MUST BE DESIGNED AND VERIFIED AS BEING IN COMPLIANCE
WITH SECTION 110 -9 OF THE N.E.C. BY LOCAL ELECTRICAL CONSULTANT.
6, THE MAIN ELECTRICAL PANEL AND FEEDERS ARE DESIGNED BY OTHERS, SITE
INSTALLED AND SUBJECT TO LOCAL JURISDICTION APPROVAL,
7. ALL CIRCUITS CROSSING OVER MODULE MATING LINE(S) SHALL BE SITE
CONNECTED WITH APPROVED ACCESSIBLE JUNCTION BOXES OR CABLE CONNECTORS,
8. RECESSED PORTIONS OF LIGHTING FIXTURE ENCLOSURES,OTHER THAN AT THE POINTS
OF SUPPORT, SHALL BE SPACED AT LEAST 1/2" FROM CUMBUSTIBLE MATERIALS.
9, THERMAL INSULATION SHALL NOT BE INSTALLED WITHIN 3" OF THE RECESSED
FIXTURE ENCLOSURE, WIRING COMPARTMENT, OR BALLAST, AND SHALL NOT BE
INSTALLED ABOVE THE FIXTURE SO AS TO TRAP HEAT AND PREVENT THE FREE
CIRCULATION OF AIR,
10. AT LEAST 1 ELECTRICAL OUTLET IN EACH ACCESSABLE SPACE
SHALL BE LOCATED NOT HIGHER THAN 48" AFF.
11. EXIT LIGHTING AND EMERGENCY LIGHTING SHALL BE LABELED AT BREAKER
PANEL AND SHALL BE ON LIGHTING CIRCUIT AHEAD OF SWITCH
MECHANICAL NOTES: 2001 FMC
1. ALL SUPPLY AIR REGISTERS SHALL BE INCHES BY INCHES ADJUSTABLE
WITH 8 INCHES BY 16 INCHES (INSIDE). x 5/8 INCH OVERHEAD FIBERGLASS
DUCT, UNLESS OTHERWISE SPECIFIED, DUCTS LOCATED IN VENTILATED ATTIC
SHALL HAVE AN INSULATION VALUE OF R -6, DUCTS LOCATED IN UNCONDITIONED
INTERIOR SPACES SHALL HAVE AN INSULATION VALUE OF R 4.2.
2, INTERIOR DOORS SHALL BE UNDERCUT 1.5 INCHES ABOVE FINISHED FLOOR
FOR AIR RETURN. ANY ON -SITE ADJUSTMENTS OF DOORS AFTER SET -UP
ARE NOT THE RESPONSIBILITY OF THE BUILDING MANUFACTURER,
3. VENT FANS SHALL BE DUCTED TO THE EXTERIOR AND TERMINATE AT AN
APPROVED VENT CAP,
4. HVAC EQUIPMENT SHALL BE EQUIPPED WITH OUTSIDE FRESH AIR INTAKE
PROVIDING 20 CFM FOR EACH OCCUPANT, OR 50 CFM FOR EACH
WATER CLOSET OR URINAL, WHICHEVER IS GREATER,
5. IN PRIVATE RESTROOMS CONTAINING ONE TOILET AND ONE LAVATORY,
RESTROOM VENT FANS SHALL PROVIDE ONE CFM PER SQUARE FOOT OF FLOOR AREA,
IN OTHER RESTROOMS FANS SHALL PROVIDE A MINIMUM OF TWO CFM
PER SQUARE FOOT OF RESTROOM SQUARE FOOT,
6, IN ANY BATHROOM THAT DOES NOT CONTAIN BATHTUBS, AND /OR SHOWERS,
MECHANICAL EXHAUST MAY BE OMITTED WHEN NATURAL VENTILATION OR
AN APPROVED RECIRCULATING AIR TREATMENT SYSTEM IS PROVIDED,
7. IF UNIT IS EQUIPPED WITH MECHANICAL ATTIC VENTILATION,
VENTILATOR SHALL BE CONTROLLED BY A HUMIDASTAT CALIBRATED TO ACTIVATE WHEN
RELITAVE HUMIDITY EXCEEDS 60%
PLUMBING NOTES:
1, CUSTOMER ASSUMES ALL RESPONSIBILITY FOR DRINKING WATER FACILITIES
DRINKING FOUNTAINS SHALL BE INSTALLED IN ACCORDANCE WITH SECTION
407 SPC 2001 EDITION, AND SECTION 415 OF THE FLORIDA ACCESSIBILITY CODE & ADAAG.
2. ALL PLUMBING FIXTURES SHALL HAVE SEPARATE SHUT- -OFF VALVES.
3, STORAGE TYPE W/H SHALL HAVE A SHUT- OFFVALVE WITHIN 3 FEET ON COLD WATER SUPPLY LINE.
4. WATER SUPPLY LINES SHALL BE POLYBUTYLENE, CPVC, OR COPPER; WHEN POLYBUTYLENE
SUPPLY LINES ARE INSTALLED, THE MAXIMUM WATER HEATER TEMPERATURE IS 180 DEGREES F.
THE POLYBUTYLENE PIPE INSTALLER SHALL VERIFY THAT IT'S USE WILL BE RESTRICTED
TO THE PRODUCT MANUFACTURER'S CONDITITIONS AND LIMITATIONS INCLUDING CHLORINE
CONCENTRATION LEVELS.
5. WATER CLOSETS ARE TANK TYPE WITH FLUSH LEVER ON WIDER SIDE OF TANK AND
URINALS ARE FLUSH VALVE TYPE UNLESS OTHERWISE SPECIFIED.
6. DWV SYSTEM SHALL BE EITHER ABS OR PVC -DWV.
7. BUILDING DRAIN AND CLEANOUTS ARE DESIGNED AND SITE - INSTALLED BY OTHERS,
SUBJECT TO LOCAL JURISDICTION APPROVAL,
8. TOILETS SHALL BE ELONGATED TYPE WITH NON - ABSORBENT OPEN FRONT SEATS,
9. RESTROOM WALLS SHALL BE COVERED WITH NON - ABSORBENT MATERIAL TO A
MINIMUM HEIGHT OF 48" A.F,F,
10. HOT WATER SUPPLY TO A FIXTURE REQUIRING HOT WATER SHALL BE INSTALLED ON LEFT SIDE
OF FIXTURE,
11. WATER SERVICE PIPING SHALL BE NOT LESS THAN ONE INCH INSIDE DIAMETER FOR GALVANIZED
FERROUS PIPING, OR 3/4" INSIDE NOMINAL DIAMETER FOR COPPER, OR APPROVED NON
CORROSIVE PIPE OR TUBE.
12, SHOWERS(WHEN PROVIDED) SHALL BE CONTROLLED BY AN APPROVED MIXING VALVE WITH A
MAXIMUM WATER OUTLET TEMPERATURE OF 120 DEG. F.
13. LAVATORIES OF PUBLIC RESTROOMS SHALL BE EQUIPPED WITH OUTLET DEVICES WHICH LIMIT
THE FLOW OF HOT WATER TO A MAXIMUM OF 0.5 GPM., OR BE EQUIPPED WITH SELF - CLOSING
VALVES (NON HANDI- CAPPED APPLICATIONS ONLY), MAXIMUM WATER TEMPERATURE IS 110 DEG,
14. INSULATE EXPOSED PIPES OF ACCESSABLE LAVITORIES
i
l
HANDICAPPED ACCESSIBILITY: ADA / ANSI A117.1 / FACBC
1.
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN SHALL BE DISPLAYED ON THE WALL AT ALL
ACCESSIBLE RESTROOM FACILITIES AND AT ACCESSIBLE BUILDING ENTRANCES UNLESS
NOTE THAT THIS LIST DOES NOT NECESSARILY LIMIT THE
ALL ENTRANCES ARE ACCESSIBLE. INACCESSIBLE ENTRANCES SHALL HAVE
ITEMS OF WORK AND MATERIALS THAT MAY BE REQUIRED
DIRECTIONAL SIGNS INDICATING THE ROUTE TO THE NEAREST ACCESSIBLE ENTRANCE,
FOR A COMPLETE INSTALLATION, ALL SITE RELATED ITEMS
2,
ACCESSIBLE DRINKING FOUNTAINS SHALL HAVE A SPOUT HEIGHT NO HIGHER THAN
ARE SUBJECT TO LOCAL JURISDICTION APPROVAL.
36 INCHES ABOVE THE FLOOR AND EDGE OF THE BASIN NO HIGHER THAN 34 INCHES
THE COMPLETE FOUNDATION SUPPORT AND TIE DOWN SYSTEM,
ABOVE THE FLOOR FOR INDIVIDUALS IN WHEELCHAIRS. ADDITIONALLY, DRINKING WATER
RAMPS, STAIRS, AND GENERAL ACCESS TO THE BUILDING,
PROVISIONS SHALL BE MADE FOR INDIVIDUALS WHO HAVE DIFFICULTY IN BENDING PROVIDE
PORTABLE FIRE EXTINGUISHER(S), MIN, 2A: 20B: C CURRENTLY TAGGED AND
STANDARD TYPE OF FOUNTAIN
DATED BY A LICENCED FIRE EQUIPMENT COMPANY. AND SHALL
3.
WHERE STORAGE FACILITIES SUCH AS CABINETS, SHELVES, CLOSETS AND DRAWERS
MOUNTED NOT TO EXCEED 48" AFF.
ARE PROVIDED, AT LEAST ONE OF EACH TYPE PROVIDED SHALL CONTAIN STORAGE
DRINKING WATER APPARATUS (WHEN NOT SHOWN ON PLAN),
SPACE COMPLYING WITH THE FOLLOWING: DOORS, ETC, TO SUCH SPACES SHALL BE
BUILDING DRAINS, CLEANOUTS, AND CONNECTION TO THE
ACCESSIBLE (ie. TOUCH LATCHES, U- SHAPED PULLS); SPACES SHALL BE WITHIN 15
PLUMBING SYSTEM,
;
INCHES MINIMUM AND 48 INCHES MAXIMUM OF THE FLOOR FOR FORWARD REACH OR 9
ELECTRICAL SERVICE CONNECTION (INCLUDING FEEDERS) TO
INCHES MINIMUM AND 54 INCHES MAXIMUM, OF THE FLOOR FOR SIDE REACH; CLOTHES
THE BUILDING.
RODS SHALL BE A MAXIMUM OF 54 INCHES ABOVE THE FLOOR (48 INCHES MAXIMUM
THE MAIN ELECTRICAL PANEL AND SUB - FEEDERS (MULTI -UNITS ONLY).
WHEN DISTANCE FROM WHEELCHAIR TO ROD EXCEEDS 10 INCHES)
CONNECTION OF ELECTRICAL CIRCUITS CROSSING OVER MODULE
4,
CONTROLS, DISPENSERS, RECEPTACLES, AND OTHER OPERABLE EQUIPMENT SHALL BE NO
MATING LINES) (MULTI -UNITS ONLY),
HIGHER THAN 48 INCHES ABOVE THE FLOOR FOR FRONT APPROACH OR 54 INCHES
STRUCTURAL AND AESTHETIC INTERCONNECTIONS !BETWEEN
ABOVE THE FLOOR FOR SIDE APPROACH. RECEPTACLES ON WALLS SHALL BE MOUNTED
MODULES (MULTI -UNITS ONLY).
NO LESS THAN 15 INCHES ABOVE THE FLOOR, EXCEPTION: HEIGHT LIMITATIONS DO
REQUIRED PLUMBING FACILITIES NOT PROVIDED IN THE MODULAR
NOT APPLY WHERE THE USE OF SPECIAL EQUIPMENT DICTATES OTHERWISE OR WHERE
BUILDING ARE TO BE LOCATED IN ADJACENT BUILDING(S), SEE
ELECTRICAL RECEPTACLES ARE NOT NORMALLY INTENDED FOR USE BY BUILDING
ATTATCHED LETTER.
OCCUPANTS,
DRAINAGE PIPING BELOW FLOOR JOIST LEVEL
5.
WHERE EMERGENCY WARNING SYSTEMS ARE PROVIDED, THEY SHALL INCLUDE BOTH
FIRE ALARM SYSTEM (IF APPLICABLE)
STRUCTURAL LOAD
AUDIBLE AND VISUAL ALARMS. THE VISUAL ALARMS SHALL BE LOCATED THROUGHOUT,
SPRINKLER SYSTEM (INSTALLED BY A LICENCED INSTALLER)
LIMITATIONS
PROOF
INCLUDING RESTROOMS, AND PLACED 80 INCHES ABOVE THE FLOOR OR 6 INCHES
EMERGENCY LIGHTING IF REQUIRED PER LOCAL GOVERNMENT SHALL BE PROVIDED AND INSTALLED
BELOW CEILING, WHICHEVER IS LOWER.
INSTALLED BY OWNER /LEASE - HOLDER.
6.
DOORS TO ALL ACCESSIBLE SPACES SHALL HAVE ACCESSIBLE HARDWARE (ie, LEVER -
GUTTERS AND DOWNSPOUTS WHEN REQUIRED AND NOT ON BUILDING ARE TO BE SITE
WIND LOAD
OPERATED, PUSH -TYPE, U- SHAPED) MOUNTED NO HIGHER THAN 48 INCHES ABOVE
INSTALLED BY OWNER /LEASE - HOLDER.
A. 146 MPH........ HIGH VELOCITY HURRICANE ZONE
THE FLOOR.
FIRE SAFETY INSPECTION COMPLYING WITH CHAPTER 663
7.
FLOOR SURFACES SHALL BE STABLE, FIRM, AND SLIP- RESISTANT. CHANGES IN
STORM SHUTTERS WHEN NOT INSTALLED WILL BE SUPPLIED AND SITE INSTALLED BY OWNER/LEASEE
C, C ..................WIND EXPOSURE CATEGORY
LEVEL BETWEEN 0,25 INCH AND 0.5 INCH SHALL BE BEVELED WITH A SLOPE NO
D. GCpi = 0,18........ WIND EXPOSURE CATEGORY
GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN 0.5 INCH REQUIRE RAMPS.
E. Pw = 65.6 PSF...... WALL COMPONENT AND CLADDING LOAD
CARPET PILE THICKNESS SHALL BE 0.5 INCH MAXIMUM, GRATINGS IN FLOOR SHALL HAVE
F. Pr = 123,7 PSF...,.... ROOF COMPONENT CLADDING LOAD
ALL
SPACES NO GREATER THAN 0.5 INCH WIDE IN ONE DIRECTION WITH LONG DIRECTION
G, THIS BUILDING IS NOT DESIGNED TO BE LOCATED ON A HILL
WITH
PERPINDICULAR TO ROUTE OF TRAVEL DOORWAY THRESHOLDS
OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT
ALL
SHALL NOT EXCEED 0.5 INCH IN HEIGHT.
8,
ALL DOORS SHALL BE OPERABLE BY A SINGLE EFFORT. ACCESSABLE DOORS CLEAR WIDTH TO
BE 32" MIN.
CARPET HAS A CRITICAL RADIENT FLUX OF 0.22 WATTS /SQ. CM
THE MAXIMUM FORCE REQUIRED TO OPEN A DOOR SHALL NOT EXCEED 8.5 LBS. FOR EXTERIOR
SWINGING
TESTED IN ACCORDANCE WITH NFiPA 253
DOORS AND 5 LBS. FOR ALL SLIDING, FOLDING, AND INTERIOR SWINGING DOORS.
9,
ACCESSIBLE WATER CLOSETS SHALL BE 17 T019 INCHES FROM THE FLOOR TO
THE TOP OF THE SEAT. GRAB BARS SHALL BE 36 INCHES LONG MINIMUM WHEN
LOCATED BEHIND WATER CLOSET AND 42 INCHES LONG MINIMUM WHEN LOCATED ALONG
SIDE OF WATER CLOSET, AND SHALL BE MOUNTED AT 33 TO 36 INCHES FROM THE FLOOR TO
THE
TOP OF THE RAIL .
10.
ACCESSIBLE URINALS SHALL BE STALL -TYPE OR WALL -HUNG WITH ELONGATED RIMS AT
A MAXIMUM OF 17 INCHES ABOVE THE FLOOR.
11,
ACCESSIBLE LAVATORIES SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES
ABOVE THE FLOOR AND A CLEARANCE OF AT LEAST 29 INCHES ABOVE THE FLOOR TO
THE BOTTOM OF THE APRON.
12,
ACCESSIBLE SINKS SHALL BE MOUNTED WITH THE RIM NO HIGHER THAN 34 INCHES
ABOVE THE FLOOR AND A KNEE CLEARANCE OF AT LEAST 27 INCHES HIGH, 30 INCHES WIDE,
AND 19 INCHES DEEP UNDERNEATH SINK, THE SINK DEPTH SHALL BE 6.5 INCHES
MAXIMUM.
PAPER ROLL IN ACCESABLE STALLS TO BE MOUNTED WITH CENTER LINE ® 8" AHEAD OF THE
WATER CLOSET
RIM, AND 4" BELOW GRAB BAR ALONG SIDE OF THE WATER CLOSET
PAPER TOWEL DISPENSERS, HAND DRIERS, SANITARY NAPKIN DISPENCERS
TO BE MOUNTED NOT HIGHER THAN 48" AFF.
13. HOT WATER AND DRAIN PIPES UNDER ACCESSIBLE LAVATORIES AND SINKS SHALL BE
INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT, THERE SHALL
BE NO SHARP OR ABRASIVE SURFACES UNDER ACCESSIBLE LAVATORIES AND SINKS.
14, ACCESSIBLE LAVATORIES AND SINKS SHALL HAVE ACCESSIBLE FAUCETS OPERABLE WITH
ONE HAND AND REQUIRING LESS THAN 5 LBS. OF FORCE TO ACTIVATE (ie LEVER -- OPERATED,
PUSH -TYPE, ELECTRONICALLY CONTROLLED). SEPARATE LAVATORIES FOR
PHISICALLY HAND]- CAPPED PERSONS SHALL NOT BE EQUIPPED WITH SELF CLOSING VALVES.
15. WHERE MIRRORS ARE PROVIDED IN RESTROOMS, AT LEAST ONE SHALL BE PROVIDED
WITH THE BOTTOM OF THE REFLECTIVE SURFACE NO HIGHER THAN 40 INCHES ABOVE THE FLOOR.
16. WHERE MEDICINE CABINETS ARE PROVIDED, AT LEAST ONE SHALL BE LOCATED WITH
A USABLE SHELF NO HIGHER THAN 44 INCHES ABOVE THE FLOOR.
17. GRAB BARS REQUIRED FOR ACCESSIBILITY SHALL BE 1.5 INCHES IN DIAMETER WITH
1,5 INCHES OF CLEAR SPACE BETWEEN THE BAR AND THE WALL,
18. TOILET STALL DOORS SHALL BE THE SELF -- CLOSING TYPE,
19, A TOWEL DISPENSER SHALL BE LOCATED ADJACENT TO ALL ACCESSIBLE LAVATORIES,
D
i
2001 FBC WITH 2003 AMENDMENTS
LISTING AGENCY
APPROVAL
THESE PRINTS COMPLY WITH THE
FLORIDA MANUFACTURED BUILDING
ACT OF 1979 CONSTRUCTION CODES
AND ADHERE TO THE FOLLOWING
CRITERIA:
CONST. TYPE VI
OCCUPANCY B
ALLOWABLE #
OF FLOORS 1
WIND VELOCITY 146
FIRE RATING OF
EXTERIOR WALLS 0
PLAN NO. MDS006954
ALLOWABLE
FLOOR LOAD 50/100
APPROVAL DATE 06/02/2010
MANUFACTURER PER DCA LETTER
APPROVED FOR HIGH VELOCITY
WIND ZONE YES
M.D.S.
DATE - - -- 06/02/2010 ____ PLAN N
APPROVED BY SAM ACOSTA
MODULAR BUILDING PLANS EXAMINER
FLORIDA CERTIFICATE NUMBER SMP- 0000034
FIRESAFETY INSPECTOR�M
CERTIFICATE NUMBER 113873
r ModSpace
MDS006954 CFfCKp,
--------- - - - - -- ., ........ .
SH T......... .
;y � •.SH T•. �3 .. .
JOHN A. B Z IAK 3637 4TH STREET NORTH
SAINT PETERSBURG, FLORIDA 33704
ARCHITECT E LICENSE #AR- 0005065
rmum Immm azw= 2730 12TH STREET SOUTH
LISTING AGENCY SAINT PETERSBURG, FLORIDA 33705
PHONE #727 -- 898 --6004
DATE SCALE QUOTE SER. NO,
06/02/2010 1 - -NTS- I MDS006954
SIZE CODE TYPE USE I ctiEcKm By I REV
PER PRINT 2001 FBC VI B MDS
MDS006954
APF
MD
:r..
2 20
✓ F # k..,PAGE" Il : `�;;EC7,;-4: 1,N
1Q6954 1 OF 4
SITE - INSTALLED ITEMS:
NOTE THAT THIS LIST DOES NOT NECESSARILY LIMIT THE
ITEMS OF WORK AND MATERIALS THAT MAY BE REQUIRED
FOR A COMPLETE INSTALLATION, ALL SITE RELATED ITEMS
ARE SUBJECT TO LOCAL JURISDICTION APPROVAL.
1,
THE COMPLETE FOUNDATION SUPPORT AND TIE DOWN SYSTEM,
2.
RAMPS, STAIRS, AND GENERAL ACCESS TO THE BUILDING,
3.
PORTABLE FIRE EXTINGUISHER(S), MIN, 2A: 20B: C CURRENTLY TAGGED AND
DATED BY A LICENCED FIRE EQUIPMENT COMPANY. AND SHALL
MOUNTED NOT TO EXCEED 48" AFF.
4.
DRINKING WATER APPARATUS (WHEN NOT SHOWN ON PLAN),
BUILDING DRAINS, CLEANOUTS, AND CONNECTION TO THE
PLUMBING SYSTEM,
;
5.
ELECTRICAL SERVICE CONNECTION (INCLUDING FEEDERS) TO
THE BUILDING.
6.
THE MAIN ELECTRICAL PANEL AND SUB - FEEDERS (MULTI -UNITS ONLY).
7.
CONNECTION OF ELECTRICAL CIRCUITS CROSSING OVER MODULE
MATING LINES) (MULTI -UNITS ONLY),
8.
STRUCTURAL AND AESTHETIC INTERCONNECTIONS !BETWEEN
MODULES (MULTI -UNITS ONLY).
9,
REQUIRED PLUMBING FACILITIES NOT PROVIDED IN THE MODULAR
BUILDING ARE TO BE LOCATED IN ADJACENT BUILDING(S), SEE
ATTATCHED LETTER.
10.
DRAINAGE PIPING BELOW FLOOR JOIST LEVEL
11.
FIRE ALARM SYSTEM (IF APPLICABLE)
STRUCTURAL LOAD
12,
SPRINKLER SYSTEM (INSTALLED BY A LICENCED INSTALLER)
LIMITATIONS
PROOF
13.
EMERGENCY LIGHTING IF REQUIRED PER LOCAL GOVERNMENT SHALL BE PROVIDED AND INSTALLED
INSTALLED BY OWNER /LEASE - HOLDER.
LIVE LOAD 30 PSF
14.
GUTTERS AND DOWNSPOUTS WHEN REQUIRED AND NOT ON BUILDING ARE TO BE SITE
WIND LOAD
INSTALLED BY OWNER /LEASE - HOLDER.
A. 146 MPH........ HIGH VELOCITY HURRICANE ZONE
15,
FIRE SAFETY INSPECTION COMPLYING WITH CHAPTER 663
B. Iw = 1.0 .... .... IMPORTANCE FACTOR
16,
STORM SHUTTERS WHEN NOT INSTALLED WILL BE SUPPLIED AND SITE INSTALLED BY OWNER/LEASEE
C, C ..................WIND EXPOSURE CATEGORY
D. GCpi = 0,18........ WIND EXPOSURE CATEGORY
INTERIOR FINISH 2001 FBC CHAPTER 8
E. Pw = 65.6 PSF...... WALL COMPONENT AND CLADDING LOAD
F. Pr = 123,7 PSF...,.... ROOF COMPONENT CLADDING LOAD
ALL
CORRIDORS AND CEILING FINISH ARE CLASS "A" GYPSUM
G, THIS BUILDING IS NOT DESIGNED TO BE LOCATED ON A HILL
WITH
FLAME SPREAD 0 -25, ANDSMOKE DEVELOPED 0 -450
OR ESCARPMENT EXCEEDING 15 FEET IN HEIGHT
ALL
INTERIOR WALL FINISH IS CLASS "A" GYPSUM
WITH
FLAME SPREAD 0 -25, ANDSMOKE DEVELOPED 0 -450
CARPET HAS A CRITICAL RADIENT FLUX OF 0.22 WATTS /SQ. CM
AS
TESTED IN ACCORDANCE WITH NFiPA 253
i
2001 FBC WITH 2003 AMENDMENTS
LISTING AGENCY
APPROVAL
THESE PRINTS COMPLY WITH THE
FLORIDA MANUFACTURED BUILDING
ACT OF 1979 CONSTRUCTION CODES
AND ADHERE TO THE FOLLOWING
CRITERIA:
CONST. TYPE VI
OCCUPANCY B
ALLOWABLE #
OF FLOORS 1
WIND VELOCITY 146
FIRE RATING OF
EXTERIOR WALLS 0
PLAN NO. MDS006954
ALLOWABLE
FLOOR LOAD 50/100
APPROVAL DATE 06/02/2010
MANUFACTURER PER DCA LETTER
APPROVED FOR HIGH VELOCITY
WIND ZONE YES
M.D.S.
DATE - - -- 06/02/2010 ____ PLAN N
APPROVED BY SAM ACOSTA
MODULAR BUILDING PLANS EXAMINER
FLORIDA CERTIFICATE NUMBER SMP- 0000034
FIRESAFETY INSPECTOR�M
CERTIFICATE NUMBER 113873
r ModSpace
MDS006954 CFfCKp,
--------- - - - - -- ., ........ .
SH T......... .
;y � •.SH T•. �3 .. .
JOHN A. B Z IAK 3637 4TH STREET NORTH
SAINT PETERSBURG, FLORIDA 33704
ARCHITECT E LICENSE #AR- 0005065
rmum Immm azw= 2730 12TH STREET SOUTH
LISTING AGENCY SAINT PETERSBURG, FLORIDA 33705
PHONE #727 -- 898 --6004
DATE SCALE QUOTE SER. NO,
06/02/2010 1 - -NTS- I MDS006954
SIZE CODE TYPE USE I ctiEcKm By I REV
PER PRINT 2001 FBC VI B MDS
MDS006954
APF
MD
:r..
2 20
✓ F # k..,PAGE" Il : `�;;EC7,;-4: 1,N
1Q6954 1 OF 4