10-640-000ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGaugeFlaCom v1.22 FORM 40OB -2001 Component Performance Method for Commercial Buildings Jurisdiction: DADE COUNTY, DADE COUNTY, FL (23 1000) Short Desc: MDS006954 Project: MOD SPACE Owner: MOD SPACE Address: UNKNOWN UNKNOWN City: UNKNOWN State: FLORIDA PermitNo: 0 -- Zip: 0 Storeys: I Type: Office (Business) GrossArea: 1400 Class: New Finished building Net Area: 1400 Max Tonnage: 4 (if different, write in) Compliance Summary Component Design Criteria Result ENVELOPF, 34.98 75.31 PASSES Other Envelope Requirements - B LIGHTING POWER LIGHTING CONTROLS EXTERNAL LIGHTING HVAC 8Y5'FEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES 1,349.04 2,659.62 PASSES PASSES PASSES PASSES PASSES PASSES PASSES Yes /No /NA IMPORTANT NOTE. An input report Print -Out from EnergyGauge FlaCom of this design building must be submitted along with this Compliance Report. 6/2/10 EnergyGauge FlaCom FLCCSB v1.22 W i4 COMPLIANCE C:ERI'll"IC NI'lON: I hereby certify that the plans and Review of the plans and specifications covered by this specifications covered by this calculation are calculation indicates compliance with the Florida Energy in compliance with the Florida Energy Code. Before construction is completed, this building will be Eff iciency Code. inspected for compliance in accordance with Section PREPARED BY: 553.908, F.S. BUILDING OFFICIAL: DATE: Z D DATE: rj 6 _ D ? _ I hereby certify t is building is in compliance with the Florida ergy Eff iciency Code. OWNER AGENT DATE: If required by Florida law, I hereby certify ( *) that the system design is in compliance with the Florida Energy Code. REGISTRATION No. ARCHITECT: ELECTRICAL SYSTEM DESIGNER LIGHTING SYSTEM DESIGNER: MECHANICAL SYSTEM DESIGNER: PLUMBING SYSTEM DESIGNER: ( *) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed /sealed Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (23 1000) (WEA File: Miami.tmy) Envelope Compliance Design Load Criteria Zone Heating Cooling Heating Cooling OFFICE AREAS (CONDITIONED) -0.80 34.18 -7.59 67.73 Total Loads: DesiLyn = 34.984 Criteria = 75.314 F PASSES 6/2/10 EnergyGauge FlaCom FLCCSB v1.22 a Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Miami.tmy) Other Envelope Requirements Item Zone Description Design Limit Meet Req. OFFICE AREA % Skylight - Max % Limit 0.00 6.70 Yes OFFICE ARE OFFICE AREF Exterior Roof - Max Uo Limit 0.05 0.08 Yes Meets Other Envelope Requirements Project: NMS006954 Allowance (W) (W) Title: MOD SPACE 2.660 Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Miami.tmy) External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Exit (with or without Canopy) 25.00 3.0 75 60 Ext Light 2 Exit (with or without Canopy) 25.00 3.0 75 60 Ext Light 3 Exit (with or without Canopy) 25.00 3.0 75 60 Design: ,180 (W) PASSES Allowance: 225 (W) Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Miami.tmy) Lighting Power Compliance Space Ashrae Description Area Height No. of AF Design ID (sq.ft) (ft) Spaces (W) OFFICE 29 Offices (Partitions 3.5 -4.5 ft 1.400 8.0 1 1.00 1927 An r ^ ° below ceiling) Open plan offices 900 ft or larger with partitions 3. Design : 1927.2 (W) Effective: 1349.04 (W) Allowance: 2659.62 (W) 6/2/10 EnergyGauge FlaCom FLCCSB v1.22 Effective Allowance (W) (W) 1349 2.660 PASSES 3 Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Miami.tmy) Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance OFFICE AREAS 29 Offices (Partitions 3.5 -4.5 ft below 1.400 7 20 8 PASSES ceiling) Open plan offices 900 ft or larger with partitions 3. PASSES Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Miami.tmy) System Report Compliance FLOOR System 2 Packaged Terminal Systems No. of Units A &B 2 Component Category Capacity Design Eff Design IPLV Comp - Eff Criteria IPLV Criteria liance Cooling System PTAC > 15000 Btu/h 10.00 7.60 PASSES (Cooling Mode) IIeating Systcm Electric Fumacc 1.00 1.00 PASSES Air Handling System Air Handler (Supply) - 0.80 0.80 PASSES - Supply Constant Volume PASSES Plant Compliance Description Installed Size Design Min Design Min Category Comp No Eff Eff IPLV IPL liance None 6/2/10 EnergyGauge FlaCom FLCCSB v1.22 C Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, FL (231000) (WEA File: Miami.tmy) Category Water Heater Compliance Design Description Type Category Min Design Max Comp Efl Eti Loss Loss liance Water Heater 1 Storage Water Heater - < =120 [gal] & <= 1.00 0.92 PASSES Electric 12 [kW] PASSES PASSES Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, F Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu -inthr Thick [in] Thick [in] [F] SF.F] Heating System (Steam, Steam 0.25 True 105.00 0.28 1.00 0.69 PASSES Condensate, & Hot Water) PASSES 6/2/10 EnergyGauge FlaCom FLCCSB v1.22 q v Project: MDS006954 Title: MOD SPACE Type: Office (Business) Location: DADE COUNTY, DADE COUNTY, F Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O&M 102.1 Operation/maintenance manual will be provided to owner Roof /Ceil 404.1 R -19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge FlaCom attached? 6/2/10 EnergyGauge FlaCom FLCCSB 0.22 6 ••• . . . • V STATE OF FLORIDA .� • 0: :. DEPARTMENT OF COMM:0i1TY:.A.F "Dedicated to making Florida a better place to call home" 0000 0000. CHARLIE CRIST • • • 0000 • Governor • • • •••• • 0.000 • January 25, 2010 George Britton ModSpace -Miami 5000 N.W. 72nd Avenue Miami, FL 33166 RE: Manufacturer Certification, ID MFT -6709; Expiration Date: May 31, 2013 Dear George Britton ••• 0000 TV OMAR G. PELHAM • • • • Secretary It is my pleasure to inform you that ModSpace- Miami, located at 5000 N.W. 72nd Avenue, Miami FL 33166, has been approved under the Manufactured Buildings Program, as provided for under Chapter 553, Part I, Florida Statutes, to manufacture Manufactured Buildings for installation in Florida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency is a contractor for the Department and has statutory authority and responsibilities that must be met to maintain approved status. You may expect and demand quality plans review and inspections. Each Code change will make your plans obsolete until they have been reviewed, approved and indicated [on the cover page of the plans] for compliance with the Code by your Third Party Agency for plans review. Please ensure that your plans are in compliance and are properly posted on our website. All site - related installation issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain in compliance with the rules and regulations of this program. Your certification is approved for three years from this date. You will receive a renewal notice by Email generated by.the BCIS (www.floridabuilding.org) for online renewal. If you have questions you may contact me at Leola Baldwin at 850 - 921 -0956 or our FAX at 850 - 414 -8436. Please visit our website at www.floridabuilding.org to see valuable information on the Florida Manufactured Buildings Program. A copy of this letter must accompany applications for local building permits. Sincerely, Robert Lorenzo Manufactured Buildings Program cc: Professional Service Industries 2555 SHUMARD OAK BOULEVARD ♦ TALLAHASSEE. FL 32399 -2100 850-488-8466 (p) # 850-921-0781 (f) • We b s i t e: www.dca.state.fl.us ♦ COMMUNITY PLANNING 850-488-2356(p) 850-488-3309(q • HOUSING AND COMMUNITY DEVELOPMENT 850-488-7956(p) 850-922-5623(f)