Loading...
10-535-006/ r^ ' � INE� OR MON R. DONNELL INE 0 // _ , / / f GENERAL GENERAL NOTES _ -- _ - - -= A. CONTRACTOR SHALL BE RESPONSIBLE FOR FERFOrvMING- A -- - WALK —THRU OF THE PROJECT PRIOR TO - 3lrBMl i I11MG 4 Bfv '�0 -11'E OWNER FOR IDENTIFYING POSSIBLE CRITGAL --NOT ALL- -ITEMS OAIDA M. ALBAISA 0 Az t CT. MIAMI, IM ' ` -ITEMS. TO BE DEMOLISHED ARE SHOWN ON THE PLAN. II: INSTITUTIONAL / / / / / . :� /! , / / B._ OPENINGS LEFT THROUGH RATED AND; SM7KE PARTITIONS DUE T0- REMOVAL OF DUCTWORK AND /OR CONDUITS' SHALL 8E - CLOSED BOTH SIDES AS PER APPLICABLE CODES. (SEE SHEET A601 FOR DETAILS) / / I 1 I I / / ' `/ / / i' � if / ♦ // /�iJ C._ SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL REMOVAL WORK OF LIGHTING, PLUMBING FIXTURES, EQUIPMENT, ETC. D._ THE CONTRACTOR SHALL COORDINATE ALL TEMPORARY WALL PARTITIONS LOCATIONS WITH OWNER. �R` .'''" '';'" - - - / / OR P T1T10 i / ! / i f // /i \\'�''" E._ THE CONTRACTOR SHALL COORDINATE WITH OWNER OR OWNER / T 9F?ARY•P �N ,% / , / :` i / REPRESENTATIVE TEMPORARY STORAGE OF ANY TYPE OF EQUIPMENT, FURNITURE, ETC., TO BE RELOCATED PRIOR TO ANY WORK. /' i // j �`�, // ;' F. THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND -`- C 'I / --�. j / DIMENSIONS PRIOR TO ANY WORK. JI z / 16 " / f / l / / ,/♦ L/ ; NOTES THIS DRAWING DOORS AND FRAME TO BE REMOVED. OPEN / WALLPAPER TO BE REMOVED. WALLS TO BE SKIM COATED. PATCH Q AND REPAIR AS NECESSARY. PAINT WALLS AS NECESSARY. H l , i'' / O ACOUSTICAL CEILING TO BE REPLACED. 1 DEMOLITION PLAN 2 DEMOLITION PLAN A101 SCALE: 1/4" = 1' -0" A101 SCALE: 1 /4" = 1' -0" j / V sL y,' I , %" ! ! j' : / / •�, �/ ' ' / / ' ',� ;:``; ,/" `' DEMOLITION LEGEND EXISTING WALL OR PARTITION TO REMAIN i/ ; ♦ / I E P9HARY P ,' j /` . ! ♦ / /% ,/ / TE P PAR ` ;' /` / ,'' / , / C WALL /PARTITION WITH EXISTING DOOR TO REMAIN / / i / , / ~.�- - -_w,, /; // ;,' / i / / ` ! ♦ / ,' / ,' �, //` ' EXISTING WALL OR PARTITION TO BE REMOVED /'" ! / / .' / I _ - - --, / WALL OR PARTITION WITH EXISTING DOOR TO BE REMOVED ♦ ;/ /`/ //` ,'`.''` ,'' ' ♦ 1 3 DEMOUTION PLAN 4-N DEMOLITION PLAN A101 SCALE: 1/4" = 1' -0" Al?M SCALE: 1/4" = 1' -0" BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 SOUTH MIAM HOSPITAL STRUCTURAL ENGINEER: r^ ' � INE� OR MON R. DONNELL INE 0 AS SHOWN OPEDRO J. DUQUESNE 4 06 -15 -2010 OAIDA M. ALBAISA 0 Az t CT. MIAMI, IM all TA 9 F FLORIDA — AUTHORIZATION No. I- ENGINEER: 0 0 f � `• c t ' L �( (, 6,. 74 1 e i:T�1�91:•l�� PROJECT NAME: SMH - EAST TOWER /MAIN BUILDING HURRICANE DOORS PROJECT ADDRESS: 7400 S.W. 62nd Ave. Soulh Miami, Florida 33143 KEY PLAN COMM. NO. 40009.100 SCALE: AS SHOWN DATE: 06 -15 -2010 DRAWN: Az CHECKED: all CADD FILE: II: INSTITUTIONAL DRAWING TITLE: DEMOLITION FLOOR PLAN SHEET NO. A107