10-327R-016GENERAL r r A NOTES L FOUNDATIONS: 10. DETAILS AND SECTIONS: DEEP FOUNDATIONS: ZONE(4) ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED AREA POSITIVE TO BE TYPICAL, AND SHALL BE CONSTRUED TO APPLY TO ANY BASED ON SOIL BORINGS AND RECOMMENDATIONS MADE BY NEGATIVE SIMILAR SITUATION ELSEWHERE ON THE PROJECT, UNLESS A PROFESSIONAL SERVICE INDUSTRIES, THE FOUNDATIONS HAVE BEEN 111 PBF. DIFFERENT DETAIL, DR SECTION, IS SHOWN. DESIGNED WITH AUGERCAST PILES, WITH THE FOLLOWING CAPACITY 26 ft? to 50 Fe % P.SF. AND MINIMUM PILE PENETRATION DEPTHS. 11. GENERAL: 16" DIAMETER, 125 TONS IN COMPRESSION, AND 80 TONS IN 92 P.S.F. IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS, TENSION. 40' MINIMUM PENETRATION AND MINIMUM ROCK SOCKET 10' 116 PSF. SPECIFICATIONS, OR OTHER DOCUMENTS, THE CONTRACTOR MUST ALL COMPRESSION PILES SHALL BE REINFORCED WITH A CAGE OF 96 P.S.F. NOTIFY THE ARCHITECT AND ENGINEER, IN WRITING, OF THE SAME 5 -06 VERTICAL BARS AND 0 3 * 12" c/c TIES FOR THE TOP 15 FEET 251 ft. to 500 ft PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. IN THE EVENT AND I '9 THE FULL LENGTH OF THE PILE. V P.SF. THAT THE CONTRACTOR FAILS t0 GIVE NOTICE, OR PROVIDE 501 ft AND UP 11 F.S.F. SUFFICIENT TIME FOR A RESPONSE, CONTRACTOR IS RESPONSIBLE SHALLOW FOUNDATIONS: 85 P.SF. FOR THE RESULTS OF SUCH ERRORS OR OMISSIONS, AND FOR ALL BASE ON SITE OBSERVATION THE FOUNDATIONS HAVE BEEN DESIGNED FROM ANY CORNER OF TWIE BUILDING. ALL OTHER LOCATIONS COSTS FOR RECTIFYING SAME AND FOR ANY DELAYS OR ANY OTHER USING 2000 P.S.F NOTE: THE WIND PRESSURES INDICATED ON THE TABLES ARE TO BE USED COSTS INCURRED BY SAME.. 2. CONCRETE: 2'411 x 24" THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS TOGETHER ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE SEE DET. C /51.1 WITH THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS STRENGTH OF 5,000 PSI IN 28 DAYS, EXCEPT FOR SLABS ON GRADE NOT USE 8 -pro TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, THAT SHALL HAVE AN ULTIMATE COMPRESSIVE STRENGTH OF 3000 12°'x12" RECESSES, OPENINGS, REGLETS, BOLT SETTINGS, SLEEVES, PSI IN 28 DAYS. AGGREGATES TO BE CLEAN AND WELL GRADED, DIMENSIONS, ETC- POTENTIAL CONFLICTS SHALL BE TRANSMITTED MAXIMUM SIZE P. CONCRETE SLUMP: 3" MIN. TO 5" MAX. TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH T14E VERTICAL CONCRETE DROP NOT TO EXCEED 8'. 12 -08 WORK CONTRACTOR TO PROVIDE ADEQUATE TIME FOR RESPONSE SEE DET. C /51.1 F/4 FROM ARCHITECT/ENGINEER 3. CONCRETE COVER: 03 6 12" SEE DET. C/51.1 TO BE AS FOLLOWS: BOTTOM TOP SIDES 12. SHORING AND RE- SNORING: FOOTINGS 311 211 311 SEE DET. C /81.1 CONTRACTOR WILL PROVIDE SHORING AND RE- SHORING DRAWINGS, GRADE BEAMS 3" 2" 211 12 -08 ALONG WITH RE- SHORING SCHEDULE FOR ALL ELEVATED STRUCTURAL COLUMNS - -- - -- 1'1/2" F/'1 COMPONENTS, INCLUDING BUT NOT LIMITED TO: BEAMS, SLABS, AND BEAMS 11/2 It 11/2" I1/211 0'3 tv 12" PRECAST JOISTS. DRAWINGS TO BE SIGNED AND SEALED BY A SLABS !" !" 1" 24" x 24" FLORIDA REGISTERED PROPES81ONAL CIVIL OR STRUCTURAL. 4. REW- ORCINCs STEEL: SEE DET, C /81.1 ENGINEER, FOR REVIEW AND APPROVAL BY THE ARCHITECT AND THE TO BE NEW HIGH STRENGTH BILLET STEEL DEFORMED AS PER ASTM MARK STRUCTURAL ENGINEER NO ELEVATED WORK MAY PROCEED WITHOUT A -305 - AND fNCx TO ASTM A 615 b0. REINFORCING THIS SUBMITTAL AND ITS APPROVAL BY ARCHITECT AND ENGINEER - - LAP CONTINUOUS TOP AND BOTTOM BARS 48 BAR DIAMETERS, AT MID B CONTRACTOR TO ALSO A 1T?AG OR AL RETAIN SAME ENGINEER TO PROVIDE FIELD SPAN FOR TOP, AND AT SUPPORTS FOR BOTTOM. PROVIDE "L" BARS E INSPECTIONS, ALONG WITH REPORTS, THAT ALL OF THE SHORING AND 30 X30 FOR TOP AND BOTTOM BARS, AT ALL CORNERS OF ALL TIE 4 RE- SHORING I6C4MPLETED AS PER HIS DRAWINGS AND BEAMS. HOOK DISCONTINUOUS ENDS OF ALL TOP BARS FOR DEPTH= 48" SPECIFICATIONS, FOR EACH LEVEL OF WORK SHORING SCHEDULE TO STRUCTURAL BEAMS (NON TIE - BEAMS). REINFORCING STEEL TO BE WIDE TIME THAT SHORES MAY BE REMOVED IN ORDER TO REMOVE FORMWORK. DETAILED AND FABRICATED IN ACCORDANCE WITH "MANUAL OF NOTE, IF THESE SHORING AND RE- SHORING CONFLICT WITH ANY STANDARD PRACTICE OF DETAILING REINFORCING CONCRETE DIRECTIVES CONTAINED IN THE JOB SPECIFICATIONS, THEN THE STRUCTURES ", AND THE ACI BUILDING CODE 318, LATEST EDITION. GOVERNING GUIDELINES WILL BE THESE. SUBMIT SHOP DRAWINGS FOR APPROVAL. 5. MASONRY: 13. CONSTRUCTION JOINTS: A. ALL CONCRETE BLOCK TO BE GRADE N -2, CONFORMING TO ASTM 8 -'r9 FOR CONSTRUCTION JOINTS IN SLABS ON FILL REFER TO SLABS ON C -90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 40 FILL SECTION AND COORDINATE WITH ARCHITECTURE. FOR BEAMS, 1,900 PSI, AND A PRISM STRENGTH OF 1,500 PSI $ -2 PROVIDE BULKHEADS AT MID -SPAN OF BEAM, AND PROVIDE BEAM (MINIMUM). MORTAR SHALL BE TYPE M, WITH A MINIMUM 8 -08 POCKET, 4" DEEP X 2/3 DEPTH OF BEAM X 2/3 WIDTH OF BEAM, STRET1GtH OF 200 PSI (USE PORTLAND TYPE CEMENT). CENTERED IN THE BEAM. PROVIDE EXPOSED REINFORCING TO TEST MASONRY UNITS AND MORTAR BY TESTING LAB AT A RATE SEE DET. D /81.1 ADEQUATELY SPLICE THE REINFORCING FOR A CLASS "C" TENSION OF EVERY 1000 SQUARE FEET OF WALLS ERECTED. 2411 x 26" LAP SPLICE. FOR SLABS, PROVIDE BULKHEADS AT A MID -SPAN B. MASONRY WALLS SHALL BE REINFORCED HORIZONTALLY WITH 6 LOCATION OF SLAB, AND PROVIDE A CONTINUOUS SHEAR KEY, GAUGE DEFORMED GALVANIZED STEEL, SPACED AT 16" C/C 20194 "c% EE $AL 6 8 "c /c CENTERED IN THE SLAB FACE. PROVIDE EXPOSED REINFORCING VERT. EXTEND HORIZONTAL REINFORCING 4" INTO ADJACENT +12' -ro" STEEL TO SPLICE THE REINFORCING. CONTRACTOR TO SUBMIT, FOR COLLk NS. PROVIDE TRUSS TYPE FOR NON - REINFORCED MASONRY 8 -+'10 APPROVAL, LOCATIONS OF BULKHEADS FOR ALL STRUCTURAL AND LADDER TYPE FOR REINFORCED MASONRY. 4d 15AL ELEMENTS THROUGHOUT JOB, PRIOR TO COMMENCEMENT OF ANY WORK C. FOR VERTICAL REINFORCEMENT, SEE SCHEDULE AND LAP 48 $ -5 +12' -811 BAR DIAMETERS MINIMUM. PROVIDE RILL BED OF MORTAR FOR ro-*8 ro -01 REINFORCED MASONRY. 14. ANCHORING EPDXY: D. PROVIDE CLEANOUTS WHEN GROUTING BLOCK CELLS, AND CLEAN SEE DET. D /81.1 FOR ANCHORING REINFORCING STEEL IN EXISTING CONCRETE USE OUT BLOCK CELLS OF ALL MORTAR DROPPINGS. MAXIMUM MARK HILTI HIT HY 150 INJECTION ADHESIVE ANCHOR OR EQUAL. OTHER VERTICAL DROP FOR GROUTING IS 4' -011. HORIZONTAL REINFORCING AVAILABLE EPDXIES ARE MADE BY ULTRA BOND OR RAWL. DRILL W -1 12" HOLES 1/8" BIGGER THAN THE DIAMETER OF THE REINFORCING STEEL 05 S 12" EACH FACE (STEEL ROD). THE DEPTH OF THE HOLES ARE TO BE A MINIMUM OF b. WIND DESIGN CRITERIA: 5 ", UNLESS OTHERWISE NOTED IN THESE PLANS, OR UNLESS ALL STRUCTURAL ELEMENTS, EXPOSED TO WIND, HAVE BEEN DESIGNED OTHERWISE INSTRUCTED BY THE MANUFACTURER'S RECOMMENDATIONS. PER THE GUIDELINES OF THE ASCE 1 -2005 BUILDING CODE. FOR WIND UPLIFT ON THE ROOFS, SEE INDIVIDUAL ROOF PLANS FOR 15. EXPANSION BOLTS. DIAGRAMS AND TABLES DICTATING THE ZONES AND THE NET UPLIFT FORCES. ALL EXPANSION BOLTS, NOTED IN PLANS, ARE TO BE HILTI TYPE KWIK BOLTS 3, OR EQUAL. FOR SUBSTITUTION, SUBMIT TO 1. SLABS ON FILL: STRUCTURAL ENGINEER FOR REVIEW AND APPROVAL. FILL AND BACKFILL TO BE COMPACTED UNDER THE SUPERVISION OF A SPECIALTY ENGINEER TO A MINIMUM OF S OF MAXIMUM DRY DENSITY FOR ALL LAYERS AS VERIFIED BY FIELD DENSITY TESTS. TESTS SHALL BE MADE IN ACCORDANCE WITH METHODS OF TESTS FOR MOISTURE DENSITY RELATIONS OF SOILS, ASTM D -1551 MODIFIED TO USE 25 BLOWS ON FIVE LAYERS WITH A 10 POUND HAMMER DROPPING 18 INCHES. IN ADDITION, A MINIMUM OF ONE IN -PLACE FIELD DENSITY TEST SHALL BE PERFORMED FOR EACH 2500 SQUARE FEET, OR FRACTION THEREOF, FOR EACH LIFT OF COMPACTED SOIL, AND SUCH TESTING SHALL BE PERFORMED IN ACCORDANCE WITH EITHER ASTM D 1556, STANDARD TEST METHOD FOR DENSITY OF SOIL IN- PLACE BY THE SANDCONEt OR ASTM D 2922, STANDARD TEST METHODS ' FOR DENSITY OF SOIL AND SOIL AGGREGATE IN PLACE BY NUCLEAR METHODS OR OTHER APPROVED METHODS. COMPACTION LAYERS NOT TO EXCEED 12 ". BACKFILL MATERIAL TO BE APPROVED BY SOIL ENGINEER SLABS TO BE PLACED CONTINUOUSLY, HOWEVER, MUST BE SAW CUT SAME DAY IT IS PLACED AND LIMITED TO 400 SF, AND 15 FEET IN ANY DIRECTION, COORDINATE WITH ARCHITECTURE FOR LOCATIONS OF T14E SAW CUTS. SUBMIT LAYOUT OF ALL SAW CUTS FOR APPROVAL. SAW CUT t0 BE A MINIMUM OF 1 INCH DEPTH AND 1/4 INCH WIDTH. PROVIDE VAPOR BARRIER BELOW ALL SLABS ON FILL (10 MIL). REFER TO ARCHITECTURE FOR REQUIRED SOIL POISONING BENEATH ALL SLABS ON GRADE. S. EXCAVATIONS: GENERAL CONTRACTOR TO NOT EXCAVATE ADJACENT TO OR NEAR NEW STRUCTURES TURES AFTER THEY HAVE BEEN CONSTRUCTED. EXCAVATIONS FOR UTILITIES ADJACENT TO OR NEAR NEW STRUCTURES TO BE COMPLETED BEFORE THE NEW STRUCTURES ARE CONSTRUCTED. COORDINATE ALL UTILITIES WITH STRUCTURAL DRAWINGS. IF CONFLICTS EXIST CONTACT ARCHITECT AND STRUCTURAL ENGINEER GENERAL CONTRACTOR TO EXERCISE CAUTION DURING EXCAVATIONS ADJACENT TO THE EXISTING STRUCTURES. IF THERE EXISTS A DEVIATION OF THE EXISTING FOUNDATION FROM WHAT IS SHOWN IN THESE PLANS, CONTACT ARCHITECT AND STRUCTURAL ENGINEER GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR THE BRACING AND LATERAL SUPPORT, AND FOR MAINTAINING THE INTEGRITY OF THE EXISTING STRUCTURE DURING ALL PHASES OF THE CONSTRICTION. S. SHOP DRAWINGS: NO SHOP DRAWING SHALL BE SUBMITTED FOR ARCHITEGTMIGINEER'S REVIEW UNTIL AFTER THEY HAVE BEEN REVIEWED AND NOTED FOR CONSTRUCTION METHOD, DIMENSIONING, AND OTHER TRADE REQUIREMENTS BY THE CONTRACTOR AND STAMPED WITH THE CONTRACTOR'S APPROVAL SEAL. ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS, QUANTITIES, ERRORS OR OMISSIONS, AS A RESULT OF CHECKING AND REVIEWING ANY SHOP DRAWINGS. WINDLOAD PRESSURE FOR SOWS, WIND LOAD PRESSURES FOR ROOFING DEI SIGN (POUNDS PER SQUARE POOI) REINFORCEMENT ZONE(4) ZONE* AREA POSITIVE WINDLOAD PRESSURE FOR SOWS, DOORS AND PANELS. (POUNDS PER SQUARE POOI) REINFORCEMENT ZONE(4) ZONE* AREA POSITIVE NEGATIVE POSITIVE NEGATIVE 10 fe to 25 It' 102 FLF. 111 PBF. 102 P.SF. 131 RSF. 26 ft? to 50 Fe % P.SF. 105 P.SR 96 P.SF. 125 P.SF. 51 ft' to 100 re 92 P.S.F. 100 P.SF. 92 F.S.F. 116 PSF. 101 ft. to 250 ft 81 RSR 96 P.S.F. 81 P.SR 106 F.S.F. 251 ft. to 500 ft 81 P.aF. 90 P.S.F. V P.SF. 94 P.SF. 501 ft AND UP 11 F.S.F. 85 P.SF. 11 FAR 85 P.SF. NOTES: I. ZONE Q5 IS DEFINED AS ANY DOOR OR WINDOW WITHIN V -m" FROM ANY CORNER OF TWIE BUILDING. ALL OTHER LOCATIONS ARE DEFINED AS ZONE 4 2,- VALUES INDICATED CAN BE INTERPOLATED. NOTE: THE WIND PRESSURES INDICATED ON THE TABLES ARE TO BE USED WITH LOAD COMBINATIONS OF ASCE -1 -05 ' »u - III -II ;11111 PILE CAP SIZE, < REINFORCING AS SCHEDULED 01 COLUMN SIZE, REINF-G, 4 CONC. STRENGTH AS NOTED IN COLUMN SCHEDULE - FOR COL. TIES, SEE TYPICAL COLUMN DETAILS. IIIEIIII � �- STD. 9 HOOK RZ u.t. = 1� I'Li TYPICAL COLUMN TO FOOTING DETAIL i�DETAIL SI3 SCALE = N.T.S. SEE PLAN ? I I FOR REINFORCING NOTE: DO NOT --� "BRICK" OFF OF PILES TO SUPPORT REINFORCING COMPRESSION PILE DETAIL i�DETAIL SI3 SCALE = N.T.S. GRADE BEAM SYMMETRICAL A60UT CENTERLINE, NOT SHOWN FOR CLARITY. SEE PLAN CONC. COL. BEYOND SEE PLAN AS SCHEDULED TOP BARS AS SCHEDULED 807TOM BARS AS SCHEDULED EL. 0' -0" T.O. SLAB 38 Bar diam Ah EL. SEE PLAN T.O. PILE GAP i =� 1 GRADE BEAM SEE PLAN _ AS SCHEDULED =I I 2 -01 BARS, 4811 LONG IIiII II ► r (SHEAR FRICTION) CLEAR 4" IN SHEARWALL PILECAP, 3" IN ALL OTHER PILECAPS PILE PILE CAP BEYOND, SEE PLAN AS SCHEDULED. TYPICAL PILE TO GRADE BEAM CONNECTION DETAIL N.T.S. ► o 12 5ARS CV MAI • �� i • • - . - • - • - i - - -- - -- - - - - -- - - - - - - -- c a_ - = LAP 24 BAR DIA • I•: 1 (UNLESS NOTED AS CONTINUOUS) LCM Es 1 1/2" COVER ALL SIDES L1 1 1 L2 1 TYPICAL BEAM DIAGRAM N.T.S. NOTES: -. 1.- "C" BARS ARE TOP BARS AT NON - CONTINUOUS ENDS. 2: "E" BARS ARE TOP BARS OVER RIGHT INTERIOR SUPPORTS. 3.- TOP BARS CALLED FOR AS CONTINUOUS, WHEN SPLICED, SHALL BE SPLICED IN THE MIDDLE THIRD OF THE SPAN. 4. REFER TO INTERMEDIATE BEAM REINFORCING FOR ADDITIONAL REINFORCING. 5.- PROVIDE AT ALL NON- BEARING BLOCK WALLS, A TIE -BEAM 8"x12" (MIN) W/2 -05 TOP AND BOTTOM CONT., 03 TIES, 4 AT 12 "c% EACH END, BAL. AT 48 "c% TIE -BEAMS MUST BE DOWELED INTO WALLS AT EACH END, AT INTERSECTIONS, AT INTERMEDIATE POINTS. 6.- PROVIDE 2 -+5 CORNER BARS (EXTEND 30 IN EACH DIRECTION FROM CORNER) AT ALL NON - BEARING BLOCK WALLS. 1.- TIE BEAM DEPTH, AS SCHEDULED, IS MINIMUM CAN BE INCREASED AS REQUIRED TO MATCH BLOCK COURSING. PROVIDE 1+5 EFIADDTL) IF INCREASE IN DEPTH EXCEEDS 8". 8. WHERE POSSIBLE TOP BEAM REINFORCEMENT SHALL EXTEND INTO THE SLAB BEYOND, FAR FACE OF COLUMN BY A DEVELOPMENT LENGTH. 9.. PROVIDE FULL TENSION LAP SPLICE AT ALL REINFORCEMENT INDICATED AS CONTINUOUS. MASONRY BLOCK WALL SCHEDULE MARK THICKNESS �C�) REINFORCEMENT REMARKS VERTICAL HORIZONTAL 125W -524 12" (2)S6 24 "EF. No.9 GAGE DURO WALL MASONRY REINFORCED. FILL REINF. CELL WITH CONC. GROUT. $W -532 8°' 05'1 32 "c /c No-g GAGE DURO WALL MASONRY REINFORCED. FILL REINF. CELL WITH CONC. GROUT. $W -546 ' 8" 050 48 "c% Nog GAGE DURO WALL MASONRY REINFORCED. FILL REINF. CELL WITH CONC. GROUT. CONCRETE FOOTING SCHEDULE MARK TH SIZE DE REINFORCEMENT REMARKS WF -3roM 3ro" (W) x 16" (D) 4 -"5 LONG WAY $ OTTOM SEE PLAN FOR TRANSV. $ARS MONOLITHIC FOOTING. -1roM fro" CW) x 12" CD) 2-5 LONG WAY 50TTOI'1 'I'3�48" TRANSV. $QTTOM MONOLITHIC FOOTING. T.E. 8" (W) x 12" (D) 2- 04 CONT., $ OOTOM THICKENED EDGE CONCRETE COLUMN SCHEDULE MARK GRIDLINE SIZE (INCHES) REINFORCING VERTICAL STIRRUPS C) 2'411 x 24" 12 -*8 )'Zl� 03 6 1211 SEE DET. C /51.1 1 C2 4 G3 NOT USE 8 -pro 12°'x12" *3tv 811 F/3 24" x 24" 12 -08 03 � 12" SEE DET. C /51.1 F/4 24" x 24" 12 -O8 03 6 12" SEE DET. C/51.1 F/5 24" x 24" 12 -08 03 � 12" SEE DET. C /81.1 F/6 24" x 24" 12 -08 03 6 12" SEE DET. C /81.1 F/'1 24" x 24" 12-09 0'3 tv 12" SEE DET. C /81.1 G/3 24" x 24" 12 -OS 03 9 12" SEE DET, C /81.1 E.E. ■EACI -I E"° INTMNINTER""ATE BE A M SCHEDULE EF. -EACH FADE MARK TOP OF BEAM LEV S� (in) REINFORCING STIRRUPS REMARKS B T C E Na. in 4 DEPTH= 48" PILE DIA.= 16" 12 -W B. HOOKED, EACH WAY $ -1 +12' -ro" 24" x 26" 8 -*8 8 -'r9 40 20°8 "c% EE $AL '� 81 °C /C SEE DET. D /51.1 $ -2 +12' -6" 2411 x 2(011 8 -08 8 -*5 40 206ro "c% EE $AL 6 8 "c /c SEE DET. D /81.1 $ -3 +12' -ra" 2411 x 26" 8 -*9 8 -x'10 40 20194 "c% EE $AL 6 8 "c /c SEE DET. D /51.1 $ -4 +12' -ro" 24" x 2ro" 8 -+'9 8 -+'10 4d 15AL 20194 "c% EE -1 8 "c /c SEE DET. D /81.1 $ -5 +12' -811 241' x 24" ro-*8 ro -01 30 11011011 SEE DET. D /81.1 CONCRETE WALL SCHEDULE MARK TICKN. VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W -1 12" "5 a 1211 EACH FACE 05 S 12" EACH FACE I n CI, N � I � 3' -10 3/411 L21-011L21-0% 31-10'3/411 11' -91 /s 11 3 P.C. SCALE: Ns1° =1' -0" DEPTH= 42" PILE DIA.= 16" 5 -03 B. HOOKED, 3 WAYS, T. 4 B. c it I �f- cfJ cn C4 2' -311 41 -011 21 -311 4 P.C. SCALE: 3 /s"=11 -0u DEPTH= 44" PILE DIA.= 16°' '5-10 B. HOOKED, EACH WAY ARCHITECT: v €: ...... -BERM-Ell-0 AJAMIL & PARTNERS, INC. Architecture Engineering Planning IntariorDes;gn Landscape Architecture 2601 i5autK Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 PLANNING ARCHITECT: WILMOT SANZ A R C H I T E C T U R E P L A N N I N G 18310 Montgomery Village Avenue Gaithersburg, Maryland 20879 301- 590 -2900 (Fax) 301- 590 -8150 STRUCTURAL pENGINEER: P q aiiNBUL TIN %INE[NmRRSS NEEA' ❑RAMON R. DONNELL avrs • ❑PEDRO J. DLOLIESDE P.E. 0022764 avaisreuc'r DADA K ALBAISA P.E. s�O y, W N .M74•r OT. NAM. -v .. SuTa Cr a,o"loA . AVTHOFMT= Nr =00 MEP ENGINEER: f'MP' 2121 Ponce de Leon Blvd. Suite 350 Carol Gables, FL 33134 •emnrxi C.orm.,rc'g "«;:;ems phone: 305.564.1692 fox 305.569.1693 Dallas . Houston . Nashville . Miami . Richmond Austin . Denver . Phoenct . Washington D.C. ccrd project number. 405112.038 EBOOD07658 IT CONSULTANT: GENE BURTON & ASSOCIATES ;X'` 1993 Cenernl George Patton Drive 5840 West 1 -20, Suite 150 F.alin, Tennessee 37067 Arlington, Texas76017 Phone: 615.376.3100 Ph-, 9 1 7 3 63 2486 far :6153763114 Fax :817.5632753 Wehuw:- gbaiw, = Afedical Equipment and Communications Planners `r`rrrrr®®rxrr f .` NO 22764 ®"11`: STATE OF �: 2 .... 1`/ e� ®t ®rS ®pt A i° x'2764 PERMIT SET . TT AtD ,[ , - -, 0. REQUEST PROJECT NAME: SOUTH MIAMI HOSPITAL SITE PREPARATION PACKAGE PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 VVlvllve. 1`a V. 'iWJ 1.1w SCALE: DATE: 0414 -2010 DRAWN: CHECKED: BH CADD FILE: ILINSTITUTIONAL. DRAWING TITLE: SCHEDULES, NOTES AND DETAILS SHEET S1,3 Ct C V UTH MIANAlt 2 2 ` -10' -10 °' 1 r- UIL I IG DEPT- STRUCTU AL SE TODN 5 P.C. �pcPRC}VED BY: a SCALE: DEPTH= 48" PILE DIA.= 16" 12 -W B. HOOKED, EACH WAY ARCHITECT: v €: ...... -BERM-Ell-0 AJAMIL & PARTNERS, INC. Architecture Engineering Planning IntariorDes;gn Landscape Architecture 2601 i5autK Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 PLANNING ARCHITECT: WILMOT SANZ A R C H I T E C T U R E P L A N N I N G 18310 Montgomery Village Avenue Gaithersburg, Maryland 20879 301- 590 -2900 (Fax) 301- 590 -8150 STRUCTURAL pENGINEER: P q aiiNBUL TIN %INE[NmRRSS NEEA' ❑RAMON R. DONNELL avrs • ❑PEDRO J. DLOLIESDE P.E. 0022764 avaisreuc'r DADA K ALBAISA P.E. s�O y, W N .M74•r OT. NAM. -v .. SuTa Cr a,o"loA . AVTHOFMT= Nr =00 MEP ENGINEER: f'MP' 2121 Ponce de Leon Blvd. Suite 350 Carol Gables, FL 33134 •emnrxi C.orm.,rc'g "«;:;ems phone: 305.564.1692 fox 305.569.1693 Dallas . Houston . Nashville . Miami . Richmond Austin . Denver . Phoenct . Washington D.C. ccrd project number. 405112.038 EBOOD07658 IT CONSULTANT: GENE BURTON & ASSOCIATES ;X'` 1993 Cenernl George Patton Drive 5840 West 1 -20, Suite 150 F.alin, Tennessee 37067 Arlington, Texas76017 Phone: 615.376.3100 Ph-, 9 1 7 3 63 2486 far :6153763114 Fax :817.5632753 Wehuw:- gbaiw, = Afedical Equipment and Communications Planners `r`rrrrr®®rxrr f .` NO 22764 ®"11`: STATE OF �: 2 .... 1`/ e� ®t ®rS ®pt A i° x'2764 PERMIT SET . TT AtD ,[ , - -, 0. REQUEST PROJECT NAME: SOUTH MIAMI HOSPITAL SITE PREPARATION PACKAGE PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 VVlvllve. 1`a V. 'iWJ 1.1w SCALE: DATE: 0414 -2010 DRAWN: CHECKED: BH CADD FILE: ILINSTITUTIONAL. DRAWING TITLE: SCHEDULES, NOTES AND DETAILS SHEET S1,3