Loading...
10-327-037Calculation Summary Label IcalcType I Units I Avg I Max I Min I Avg/Min I Max /Min Construction Pa Illuminance JFc 13.75 16.5 11.4 12.68 14.64 WUP WUP — — ow .�, WUP CONSTRUCTION TRAILER 0 2SCALE: 1/16" = T-0" I PHOTOMETRICS MIAMI HO~ WUP W WUP SUP A SUP FITTER, POLE -- GROUND BROUGHT OUT THRU TENON, BOND TO FIXTURE INTERNALLY NOTE: PROVIDE MANUFACTURER'S CERTIFICATION THAT ENTIRE ASSEMBLY IS RATED TO WITHSTAND A SUSTAINED WIND VELOCITY OF NOT LESS THAN 110 MPH. WITH A GUST FACTOR OF 1.2 R 0 I Q N GRADE 6 I 0 LIGHTING FIXTURE PRECAST TAPERED CONCRETE POLE HAND HOLE WITH ALUMINUM COVER PLATE CONCRETE PULL BOX BROOKS SERIES 36 WITH COVER PLATE. 2 Cu. FT. 3/4" CRUSHED STONE — COPPER CLAD GROUND ROD 5/8' X 10' -0" 03POLE MOUNTING DETAIL SCALE: N,s 6 1 Z' I 1 I I I I I 1YryIINIn Il O O t , U PANEL: LC FED FROM: FPL NORMAL LOCATION: TRAILER SITE WIRES: 3W + G NEUTRAL BUS: No MAIN BUS: 225A ENCLOSURE NEMA 3R GROUND BUS: Yes MCB: 200A BUS TYPE: Copper ISOLATED GROUND BUS. No VOLTAGE 208/120 MOUNTING: Surface 200% NEUTRAL: No NC: 10,000A PANEL LUGS: Main Circuit Breaker FEED THROUGH LUGS: Yes CKT NO. DESCRIPTION TOTAL LOAD VA CIRCUIT BREA10 PHASE CIRCUIT BREAKER TOTAL LOAD VA DESCRIPTION CKT NO AMPS POLES AMPS POLES 1 EXISTING PANEL "A" NOTE 1 8000 100 2 A 100 2 8000 EXISTING PANEL "B" NOTE 1 2 3 - 8000 - - B - - 8000 - 4 5 SPACE - A 25 1 1800 GATE NOTE 2 6 7 PARKING LOT LIGHTING WEST NOTE 3 1800 20 1 B 20 1 - PARKING LOT LIGHTING EAST NOTE 3 8 9 - A - 10 11 - B - 12 13 - A - 14 15 - B - 16 17 - A - 18 NOTES: NOTE 1: PROVIDE A 2P -100A CB WITH 39, 1#8G IN 1 1/4 "C. NOTE 2: PROVIDE A 1P -20A CB WITH 2110, 11106 IN 3/4 "C. TO BE CONTROLLED VIA NEW N&A 313 TIMECLOCK. NOTE 3: PROVIDE A 1P -25A CB WITH 2110, 111OG IN 3/4 "C. 'LC' LOAD SUMMARY LTS RCPTS MISC TOTAL (KVA) TOTAL (AMPS) TOTAL CONNECTED LOAD 1.8 0.0 33.8 35.8 171.2 DEMAND FACTOR SEE DEMAND FACTOR TABLE TOTAL DEMAND LOAD 1.8 0.0 1 33.8 1 35.8 1 171.2 CONTINUOUS (DESIGN) FACTOR 1.25 1.00 1 1.00 TOTAL DESIGN LOAD 2.2 0.0 1 33.8 1 36.0 1 173.3 D 0CONSTRUCTION TRAILER ELECTRICAL 1 �a� 1/16" . ,-� KEYED NOTES: Oj RUN CONDUIT UNDERGROUND TO CORRESPONDING PANELS INSIbE TRAILER. 20 OPROVIDE 2#12, 1112G IN 3/4 "C AND NEW 2P -20A CIRCUIT BREAKER. BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 2601 South Bayshore Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 PLANNING ARCHITECT: W I LMOT SANZ A R C H I T E C T U R E P L A N N II N G is s o 2w -tea -� ao+-e0"50 STRUCTURAL ENGINEER: ❑P®RO a Du0W8W %,JqM DADA M. ALBAI8A �m.14"A MEP ENGINEER: 2121 Ponce de Leon Blvd., Suite 350 Coral Gables, FL 33134 Professional Consulting Engineers phone: 305.569.1692 fox: 305.569.1693 Dallas . Houston . Nashville Miami . Richmond Austin . Denver . Phoenix . Washington D.C. ccrd project number: 409337 EB00007658 IT CONSULTANT: GENE BURTON & ASSOCIATES 1893 General George Patton Drive 5840 West (-20, Suite 150 Franklin, Tennessee 37067 Arlington, Texas 76017 Phone: 615.376.3100 Phone: 817.563.2486 Fax: 615.376.3114 Fax: 817.563.2753 Website.- www.gbain ,.con Medical Equipment and Communications Planners 11111/11 PERMIT SET EVISIONS: 2 03.19.2010 MEP COORDINATION 15 11.11.2010 CLIENT REQUEST 20 02.11.2010 CLIENT REQUEST PROJECT NAME: SMH- CLINICAL EXPANSION SITE PACKAGE PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 KEY PLAN COMM. NO. SCALE: - DATE: 04 -08 -2010 DRAWN: CCRD CHECKED: CCP,11) CADD FILE: DRAWING TITLE: CONSTRUCTION TRAILER - ELECTRICAL SHEET NO. ET1,01 l' 0