10-264-013ELECTRICAL REMODELING AND DEMOLITION NOTES: I. ALL WORK AND MATERIALS SHALL BE NEW AND PROVIDED 13Y THIS CONTRACTOR UNLESS OTHERWISE NOTED AS EXISTING TO REMAIN OR 13E RELOCATED. WORK SHALL ALSO INCLUDE THE REMOVAL AND DISPOSAL OF MATERIALS FROM THE SITE AND THOROUGH CLEANING OF THE PREMISES UPON COMPLETION OF THE WORK AS DIRECTED BY ARCHITECT/TENANT AND LANDLORD, 2. WORK SHALL INCLUDE PROVISIONS OF ALL MATERIALS, CUTTING, EXTENSIONS, CONNECTIONS, PATCHING, PAINTING, REPAIRING, ADAPTING AND OTHER WORK INCIDENTAL THERETO, TOGETHER WITH SUCH TEMPORARY CONNECTIONS AS MAY BE REQUIRED. 3. ANY WORK NOT SHOWN OR SPECIFICALLY MENTIONED ON PLANS AND /OR SPECIFICATIONS BUT CONSIDERED NECESSARY FOR COMPLETION OF THE WORK IN THE PROPER MANNER SHALL BE PROVIDED BY THIS CONTRACTOR WITHOUT ADDITIONAL CHARGE. 4. WHERE PRESENT WORK IS DAMAGED IN THE EXECUTION OF THIS CONTRACT, OR WHERE OPENINGS ARE LEFT DUE TO THE REMOVAL OF PIPES, EQUIPMENT OR APPARATUS, THE SAME SHALL BE REPAIRED OR CLOSED UP TO CORRESPOND IN MATERIAL, QUALITY, SHAPE AND FINISH WITH THAT OF SIMILAR AND ADJOINING WORK, UNLESS OTHERWISE CALLED FOR WHEN DAMAGE IS UNREPAIRABLE, NEW ITEMS OR EQUIPMENT SHALL BE PROVIDED. PROVIDE ALL NECESSARY WATERPROOFING, FIRE STOPPING AND SEALING OF PENETRATIONS LEFT FROM REMOVED EQUIPMENT OR PRODUCED BY THIS WORK 3. INTERRUPTION OF EXISTING SERVICES AND /OR OPERATION OF FACILITIES SHALL BE KEPT TO A MINIMUM. CONTRACTOR SHALL FURNISH ALL MATERIALS REQUIRED WHENEVER TEMPORARY CONNECTIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE. INTERRUPTION OF EXISTING SERVICES, THE INSTALLATION OF TEMPORARY FACILITIES, AND THE WORK OF MAKING FINAL CONNECTIONS TO THE NEW WORK SHALL BE DONE ONLY AT SUCH TIMES PERMITTED AND SCHEDULED IN ADVANCE BY THE ARCHITECT/TENANT AND LANDLORD WITHOUT ADDITIONAL COST. CARE MUST BE USED IN REMOVING SERVICES TO AREAS BEING DEMOLISHED SO THAT SERVICES TO OTHER AREAS WHICH MIGHT BE SERVED THROUGH THESE AREAS WILL NOT BE INTERRUPTED. 6. WHERE DEMOLITION WORK REQUIRES TEMPORARY INTERRUPTION OF ELECTRICAL, TELEPHONE, TV, ALARM OR COMMUNICATION SERVICES, RESPECTIVE UTILITIES AND /OR COMPANY REPRESENTATIVES SHALL BE NOTIFIED AS NECESSARY AND ALL WORK DONE UNDER THEIR SUPERVISION AND ESTABLISHED STANDARDS. 1. ALL LIG14TING FIXTURES, RECEPTACLES, SWITCHES, WIRING DEVICES, SPECIAL OUTLETS, TELEPHONE CABLES, TV CABLES, MISCELLANEOUS SYSTEM WIRING, POWER CONDUCTORS, CONDUITS, ELECTRICAL BOXES, RACEWAYS AND ANY OTHER ELECTRICAL SYSTEM COMPONENTS LOCATED IN THE AREAS SHOWN AS BEING DEMOLISHED OR NOT USED AFTER WORK IS COMPLETED SHALL BE REMOVED UNLESS OTHERWISE NOTED AS EXISTING TO REMAIN OR EsE RELOCATED. RELOCATED LIGHTING FIXTURES SHALL BE RELAMPED/REBALLASTED, WITH DIFFUSERS REPLACED/REFURBISHED AS REQUIRED. CONDUITS RUN IN SLAB IN FINISHED AREAS SHALL BE CUT FLUSH, PLUGGED AND ABANDONED AFTER CONDUCTORS ARE REMOVED* WHERE PREVIOUSLY APPROVED BY ARCHITECT/TENANT AND LANDLORD, CUT 6 INCHES FROM SLAB AND CAP ACf.ORDINGLY WHERE TERMINATED IN OTHER AREAS. NO WIRING SHALL BE LEFT ABANDONED AFTER WORK IS COMPLETED. S. EXISTING AREAS WHERE NO ELECTRICAL WORK IS TO BE DONE SHALL REMAIN CONNECTED TO EXISTING PANEL($) OR BE RECONNECTED TO CIRCUITS AS NOTED ON PLANS. DISCONNECTS, PROTECTION AND WIRING SHALL MATCH EXISTING WIRING CONNECTION. % EXISTING EQUIPMENT TO BE RELOCATED OR TO REMAIN SHALL BE RECONNECTED TO CIRCUIT BREAKERS ORIGINALLY FEEDING SUCH EQUIPMENT UNLESS OTHERWISE NOTED. 10. CIRCUIT BREAKERS INSTALLED IN EXISTING PANELS SHALL BE FULLY COMPATIBLE AND OF THE SAME TYPE, RATING, MODEL AND MANUFACTURER AS PANEL. 11_ EXISTING NON - GROUNDING: TYPE RECEPTACLES SHALL BE REPLACED WITH GROUNDING TYPE RECEPTACLES. OUTLETS AND RECEPTACLES WITHIN 6 FEET FROM SINKS AS WELL AS WET AND /OR OUTDOOR LOCATIONS SHALL BE PROVIDED WITH GFI RECEPTACLES OR CIRCUITS. 12. WHERE PREVIOUSLY APPROVED BY THE ARCHITECT/ENGINEER, CONTRACTOR MAY REUSE EXISTING RACEWAYS DEEMED IN ACCEPTABLE CONDITION IN ORDER TO MINIMIZE CUTTING OF SLABS, PLASTER PARTITIONS, CEILINGS AND FLOORS, ANY CUTTING OF EXISTING SURFACES SHALL BE LIMITED TO THE NARROWEST CUT OR TRENCH THAT WOULD ACCOMMODATE BRANCH CIRCUITING AND OUTLET BOXES. 13. AFTER THE WORK IS COMPLETED ALL CONDUCTORS SHALL BE COPPER RUN IN RACEWAYS_ ALUMINUM WIRING AND ROMEX TYPE NON - METALLIC GABLE ARE NOT ACCEPTABLE* ANY WIRING FOUND DURING REMODELING SHALL BE REPLACED WITH COPPER CONDUCTORS OF EQUAL OR GREATER AMPACITY RUN IN CONDUIT. SCALE; 1/4" = T -0" - LABOR AND DELIVERY ELECTRICAL LEGEND (DEMO PLAN ONLY) ,z 20A, 120V, DUPLEX RECEPTACLE (D: 20A, 120V, GFCI DUPLEX RECEPTACLE Y 20A, 120V, ABOVE COUNTER GFCI DUPLEX RECEPTACLE PHONE i DATA OULET Q DATA OULET ® TV OULET E EXISTING DEVICE TO REMAIN ER EXISTING DEVICE TO BE RELOCATED, SEE PROPOSSED PLAN FOR NEW LOCATION. D DEVICE TO BE DEMOLISHED Ln LIC -44T SWITCH T 3 -WAY LIGHT SWITCH O RECESSED MOUNTED CEILING LIGHT FIXTURE 2'X4' FLUORESCENT LAMP - DEMOLITION PLAN n c C A n s C z a CL EIRJA DE] edward lewis architects Imawllnxf eT YUMM OF PMMKff 1 SAY. R =W �1111 Ll ARCID119 M NL AACNIM &m AND �A NWW J 0 P ElNG14HERNO GROUP PA MIAMI, FLORIDA EW 000071863 fp8041 N.W. 14TH STREET DORAL, FLORIDA, 33126 (305) 436 -9292 FAX (305) 436 -9272 E -MAIL- JGPMIAMI@BELLSOUTH.NET JOSE G. PUIG FLORIDA P.9, # 47817 JOSE G. PUIG JR. FLORIDA P.E. # 49148 HECTOR M. BLgSCO FLORIDA P.E. # 56113 Y • ' RNrNlO� PION WAOM- 00 -058 Dd February, 2010 ftm Tft ELECTRICAL DEMOLITION PLAN I I ? Dry by KL CUSM bar Munn I �t NN■16� E -02 Uj aIm J o cc =c000 m °-O = o � o ol W woo 0 0 ,j Y • ' RNrNlO� PION WAOM- 00 -058 Dd February, 2010 ftm Tft ELECTRICAL DEMOLITION PLAN I I ? Dry by KL CUSM bar Munn I �t NN■16� E -02