Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-264-010
©OSTING CORRIDOR v r I I I I I � 3rd FLOOR - LABOR AND DELIVERY PLUMBING LAYOUT SCALE: 1/4" = 1' -0" GENERAL NOTES: O ALL PLUMBING INSTALLATION SHALL BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, AND ALL OTHER LOCAL AUTHORITIES HAVING JURISDICTION. O RISER CLAMPS FOR COPPER PIPES SHALL BE COPPER FINISH. O ALL SANITARY AND VENT PIPING SHALL BE CAST IRON NO HUB OR COPPER. ALL WATER PIPING SHALL BE COPPER TYPE 'L' CASTM -B -306). O ALL PIPING TO BE IN ACCORDANCE WITH FBC 1210%1 , 603A , AND 6043. O METAL HANGERS SHALL BE USED. CARE SHALL BE EXERCISED NOT TO COMPRESS AND DISTORT THE PIPE. HANGERS SHALL BE COPPER CLAD. THE PLUMBING CONTRACTOR SHALL SECURE APPROVAL AND ADVICE FROM THE O ARCHITECT AND STRUCTURAL ENGINEER FOR THE LOCATION OF PIPES INSIDE WALLS OR SLABS. O PLUMBING CONTRACTOR MUST COORDINATE WITH FIXTURE SUPPLIER FOR EXACT LOCATION OF ROUGHING -IN. O FOR EXACT LOCATION OF PLUMBING FIXTURE COORDINATE WITH ARCHITECTURAL DRAWINGS. OCONTRACTOR SHALL INSTALL A COMPLETE PLUMBING SYSTEM AS SHOWN N DRAWINGS 9 AND AS CALLED FOR IN THE SPECIFICATIONS. ALL CAST IRON OR COPPER PIPING SHALL BE SUPPORTED AT INTERVALS OF NOT MORE O THAN FOUR (4) FEET AT END OF BRANCHES AND ALL FONTS N CHANGES OF DIRECTION TRAP ARMS N EXCESS OF THREE (3) FEET SHALL BE SUPPORTED AS CLOSE AS POSSIBLE TO THE TRAP. it SUBMIT FOR ENGINEER'S APPROVAL, LITERATURE OF PIPES MATERIAL, VALVES, FLOOR DRAINS, FIXTURES, FOR REVIEW AND APPROVAL. O THE CONTRACTOR SHALL PROVIDE PROTECTION FOR THE SURFACES OF ALL PLUM- BING FIXTURES FROM DAMAGE BEFORE, DURING: AND AFTER THEIR INSTALLATION AND UNTIL WORK IS COMPLETED AND ACCEPTED. CONTRACTOR AND SUBCONTRACTOR SHALL NOT USE PLUMBING FIXTURES FOR THE STORAGE OF TOOLS OR MATERIALS, NOR AS SUPPORTS OR PLATFORM. EVERY PRECAUTION SHALL BE TAKEN DURING THE PERIOD OF CONSTRUCTION TO AVOID DAMAGE TO FIXTURES AND FITTINGS. ANY FIXTURE OR FITTING THAT 18 DAMAGES PRIOR TO ACCEPTANCE SHALL BE REPLACED, AT NO ADDITIONAL COST TO THE OWNER. ALL WORK BELOW MUST FOLLOW INFECTIOUS CONTROL PROCEDURES FL.UM51NG 51''1" 50L. LEGEND SYMBOL DESCRITION -- - - - - -- SANITARY, VENT, CW 4 HW LINE EXISTING. TRAP SANITARY LINE -- - - - - -- VENT LNE -- -. -- COLD WATER LINE - -- - - -- HOT WATER LINE 1/2' GATE VALVE f-- CLEANOUT CONNECTION TO EXISTING .�U) WATER ISOMETRIC N.T.S. THESE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND ARE INTENDED TO CONVEY THE O SCOPE OF THE WORK AND INDICATE GENERAL ARRANGEMENT OF EQUIPMENT, PIPING AND FIXTURES. DO NOT SCALE DRAWING, REFER TO DIMENSIONED ARCHITECTURAL DRAWINGS. � THE LOCATION OF ALL ITEMS SHOWN ON THE DRAWINGS ARE NOT DEFINITELY FIXED l�J BY DIMENSIONS ARE APPROXIMATE ONLYTHE EXACT LOCATIONS NECESSARY TO SECURE THE BEST CONDITIONS AND RESULTS MUST BE DETERMINED BY THE CONTRAC- TOR AT THE PROJECT AND SHALL BE ILLUSTRATED IN THE REQUIRED SHOP DRAWINGS FOR THE ARCHITECT'S APPROVAL BEFORE ACTUAL INSTALLATION. O THE SPECIFICATIONS AND DRAWINGS CALL FOR FINISHED WORK,TESTED AND READY FOR OPERATION.ANY APPARATU6,MATERIAL OR WORK NOT SHOWN ON THE DRAW - INGS OR SPECIFICATION BUT NECESSARY TO MAKE THE PLUMBING WORK COMPLETE SHALL BE PROVIDED BY CONTRACTOR AS IF SPECIFICALLY CALLED FOR BY THESE CONTRACT DOCUMENTS, CONTRACTOR SHALL VERIFY IN THE FIELD ALL INVERT AND GRADE ELEVATIONS AND O MAKE ANY NECESSARY ADJUSTMENTS AS REQUIRED BY THE FIELD CONDITIONS, AND REQUIRED TO OBTAIN THE PROPER SLOPE. O THE CONTRACTOR MUST INSPECT PROJECT SITE AND MUST COORDINATE HIS WORK. WITH THAT OF OTHER TRADES PRIOR TO SUBMITTING HIS PROPOSAL FOR THIS WORK. AFTER CONTRACT IS AWARDED, NO EXTRAS WILL BE ALLOWED FOR COORDINATION OR FOR PROJECT SITE CONDITIONS. O ALL CUTTING REQUIRED TO PERFORM THE WORK UNDER THIS CONTRACT WILL BE DONE BY MECHANICAL CONTRACTOR. ANY CUTTING OF STRUCTURE MUST BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO EXECUTION OF WORK n GENERAL CONTRACTOR TO COORDNATE LOCATIONS AND SIZES OF ALL ACCESS DOORS WITH ARCHITECTURAL DRAWINGS. PLUMBING CONTRACTOR MUST VERIFY THE SIZES OF THE PLUMBNG CHASES PRIOR TO sra THE START OF CONSTRUCTION AND REPORT ANY CONFLICTS TO ARCHITECTS. PLEASE REFER TO ARCHITECTURAL DRAWING FOR PLUMBING CHASE DIMENSIONS- COMPLETE SYSTEM FIXTURES AND EQUIPMENT SHALL BE GIVEN AN sl N- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. O ALL PLUMBING FIXTURES TO COMPLY WITH MDC ORDINACE 831 FLUM51NG F1XTUfi�'.E 5CHEI ULE ITEM DESCRIPTION WATER SUPPLY TRAP VENT GOLD Not SK SINK 1/2' 1/2' 1 -1/2' 1 -1/2' LOUNGE: ADVANCE TABCO MODEL: 0I -1 -5 SELF -RIM FOR HAND SINK USE. MEDICAL GAS NOTE: 1- CONTRACTOR MUST COORDINATE W/HOSPITAL PERSONNEL TIE -IN FONTS FOR MEDICAL GASES AND ANY REQUIREMENTS BY THE HOSPITAL FOR ZONE ALARMS AND SHUT OFF VALVES. 2 -. ALL COMPONENTS REQUIRED TO PROVIDE A COMPLETE, PERMITABLE AND WORKING SYSTEM SHALL BE INCLUDED IN THE CONTRACTORS BID. CONTRACTOR SHALL COORDINATE W/ HOSPITAL PERSONNEL ALL COMPONENTS REQUIRED BY HOSPITAL STANDARDS, TO PROVIDE MEDICAL GAS SERVICE. 3- COMPONENTS SHALL BE MANUFACTURED BY AMIGO CORPORATION. 4- EXACT LOCATION TO BE DETERMINATE BY END USER AND THE PROJECT MANAGER GC IS TO COORDINATE. 5- ALL PLATES ARE TO MATCH EXISTING. GC TO COORDINATE WITH THE PROJECT MANAGER 6- All MEDICAL GAS CONSTRUCTION SHALL COMPLY WITH NFP.A 99 < I 11 T • y \\���.0 Ig'f• � AogH' r I I�I SANITARY ISOMETRIC N.T.S. NOTES AND DETAILS (610� A*' v 3 X edward lewis architects Mi4 iw 1S! i111RT VLL MII OP PALMffM SAY, FL3'IW PP" 2344M IF(7"a24Ip �INAM LdwM MfS/I�C'IS„ NC. C, E MIAM I�MRM MUP 11140ow J Q P ENGREEFNQ GROUP PA MIAMI, FI -OKIDA ER"000ff I84 8041 N.W. 14TH STREET DORAL, FLORIDA, 33126 <305) 436 -9292 FAX (305) 436-9272 E -MAILi JGPMIAMIBDELLSOUTHAET JOSE G. PUIG FLORIDA P.E. it 47817 JOSE G. PUIG JR. FLORIDA P.E. # 49148 HECTOR M. BLASCO FLORIDA P.E. # 56115 sbr0rtllrrl d1�NK W „a C0 =� ®Q 0 0. o -m = o o "' � � o o Uj IL ~ 8 0 0J to U. U projed mmobw 09 -056 Deb February, 2010 8md TNN 0 .-, 0 N Dna by KL c(U C#oOkmill bp 11111=1a d SbNit MA■IbW P -01 0 a-