Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10-1098-002
.• 2X4 'S 12' D/C FIRST 4 FEE r 2 2x6 END WALLS CONTINUOUS TO --a BOTTOM OF ROOF DECKING co tn PASSIVE GABLE VENT n N 26' i GAL WIN 1.01f 2X4 -S 72" 0/ 12014., 10 ctr FIRST 4 FEET 120— 9., 3" VTR 3" LAV 3" 1 1/2" 3" W. C, D.W.V. RISERS N T. S. TO WASTE TERM. 3 TON HVAC W/10 KW HEAT STRIP 1095 CFM ♦ .5 IWC ESP 2AOV„ 10 HVAC UNIT PROVIDED WITH FRESH AIR INTAKE. CRT #1,3A BARD WH361 -A10 CFM GABLE VENT FAN X19" X5 /4" OVERHEAD IERGLASS JUMP DUCT f14 "X14" RETURN GRILLS, 'URBED INTO PLENUM 4ED with 1/2" GYPSUM, 3 ION HVAC W /10 KW NEAT STRIP 1005 CFM • .5 IWC ESP 24OV„ 1i HVAC UNIT PROVIDED WITH FRESH AIR INTAKE. CRT 41.39 BARD M4341 -AIO 2X6 END WALLS CONTINUOUS TO BOTTOM OF ROOF DECKING COLUMN /STRAPPING SCHEDULE (2) 2x4 SPF #2 THIS HALF O ( 2) iB O (3) 2x4 SPF #2 THIS HALF Op (3) 2x4 SPF #2 EACH HALF (4) 2x4 SPF #2 THIS HALF O (4) 2x4 SPF #2 EACH HALF I O(5) 2x4 SPF #2 THIS HALF O ( 5) 2x4 SPF #2 EACH HALF NOTES: LIGHTS RECEPTS 1, ALL COLUMN STUDS SHALL BE GLUE /NAILED TOGETHER OFFICE Ln EACH COLUMN, 3, COLUMN STUDS SHALL NOT BE NOTCHED OR 17LE vI I SHALL BE 1 1/2" X 30 GA, WITH 14, 16 GA,X 7 16" CROWN 1 1/8" LONG STAPLES EACH DOUBLE STRAP 28 I UNLESS OTHERWISE NOTED, 15A—B LIGHTS RECEPTS 20A 1P 12 -2 12' -.. 2 QI I 20A 1P 12 -2 ALL PORTABLE APPLIANCES, INCLUDING W /H, TO HAVE DISCONNECT IF NOT WITHIN VIEW OF ELECTRIC PANEL. I L --------------------------------- 3 1" OVERHANG SIDES (T17') 2X4'5 12" 01C FIRST 4 FEET 26' i GAL WIN 1.01f 2X4 -S 72" 0/ 12014., 10 ctr FIRST 4 FEET 120— 9., 3" VTR 3" LAV 3" 1 1/2" 3" W. C, D.W.V. RISERS N T. S. TO WASTE TERM. 3 TON HVAC W/10 KW HEAT STRIP 1095 CFM ♦ .5 IWC ESP 2AOV„ 10 HVAC UNIT PROVIDED WITH FRESH AIR INTAKE. CRT #1,3A BARD WH361 -A10 CFM GABLE VENT FAN X19" X5 /4" OVERHEAD IERGLASS JUMP DUCT f14 "X14" RETURN GRILLS, 'URBED INTO PLENUM 4ED with 1/2" GYPSUM, 3 ION HVAC W /10 KW NEAT STRIP 1005 CFM • .5 IWC ESP 24OV„ 1i HVAC UNIT PROVIDED WITH FRESH AIR INTAKE. CRT 41.39 BARD M4341 -AIO 2X6 END WALLS CONTINUOUS TO BOTTOM OF ROOF DECKING COLUMN /STRAPPING SCHEDULE (2) 2x4 SPF #2 THIS HALF O ( 2) 2x4 SPF #2 EACH HALF O (3) 2x4 SPF #2 THIS HALF Op (3) 2x4 SPF #2 EACH HALF (4) 2x4 SPF #2 THIS HALF O (4) 2x4 SPF #2 EACH HALF I O(5) 2x4 SPF #2 THIS HALF O ( 5) 2x4 SPF #2 EACH HALF NOTES: LIGHTS RECEPTS 1, ALL COLUMN STUDS SHALL BE GLUE /NAILED TOGETHER PVA GLUE WITH 100% COVERAGE SHALL BE USED 2. INSTALL 2 STEEL STRAPS AT EACH STUD OF EACH COLUMN, 3, COLUMN STUDS SHALL NOT BE NOTCHED OR BORED. 4. ALL STEEL STRAPS AT SUPPORT COLUMN LOCATIONS SHALL BE 1 1/2" X 30 GA, WITH 14, 16 GA,X 7 16" CROWN 1 1/8" LONG STAPLES EACH DOUBLE STRAP END OR EQUAL FROM RIDGE BEAM TO COLUMN AND COLUMN TO FLOOR UNLESS OTHERWISE NOTED, 15A—B SYME?rDLS: DUPLEX RECEPT 0 16" AFF DUPLEX RECEPT © 42" AFF RECEPT 220 VOLT FLOOR RECEPTACLE SWITCH 3 WAY SWITCH PHONE JACK ® 16" AFF ® FLOOR PHONE JACK O THERMOSTAT INCANDESCENT LIGHT 60W, MAX. -(;)-W. p, WATER PROOF PORCH LIGHT 60W. MAX. FLUORESCENT FIXTURE 157,6 W, MAX, RECESSED FLUORESCENT 87,6 W. MAX. 0 JUNCTION BOX Q JUNCTION BOX © 100 CFM EXHAUST FAN Ij EXHAUST FAN WITH LIGHT 11 Dl EMERGENCY LIGHT L' JV J BOX FOR MANUAL PULL STATION k BELL MP J BOX FOR MANUAL PULL STATION ® 12 "x12" SUPPLY AIR REGISTER 12 "x12" RETURN AIR GRILLE IN 9x18 JUMP INTO PLENUM ELECTRIC SCHEDULE CIRCUIT # NOMENCLATURE BREAKER (AMPS) IWIRE SIZ CU. NM. IW/G 1 k 2 HVAC SIZED PER MFR. SPECS, 36 WATER HEATER 20A 1P 12--2 4A —B LIGHTS RECEPTS 20A 1P 12 -2 5A —B LIGHTS RECEPTS 20A 1P 12 -2 6A —B LIGHTS RECEPTS 20A 1P 12 -2 7A —B LIGHTS RECEPTS 20A 1P 12 -2 15A—B LIGHTS RECEPTS 20A 1P 12 -2 9A —B LIGHTS RECEPTS I 20A 1P 12 -2 ALL PORTABLE APPLIANCES, INCLUDING W /H, TO HAVE DISCONNECT IF NOT WITHIN VIEW OF ELECTRIC PANEL. ANY CHANGES OR REVISIONS CUSTOMER APPROVAL PANEL "A" KVA GENERAL LIGHTING .... . CHARGES. SPACE 2008 GA. 31533 FAX 912 383 -7821 FAX 912 384 -9209 0035 KW SF x 607 SF x 1,25 2.66 6 REVISION DATE. SIZE 24X60' 5 RECEPTS 9 180 VA /1000 .9 DATE 10 -8 -2003 HVAC 10.9 RAWING TITLE 1 FAN ,3 KW x 1,25 .75 CARPET TOTAL 15,21 TRIM COLOR TOTAL /2400000 63.38 SEALS FL INSTALL 100 AMP PANEL 120/240V 10 OTHER PANEL "B" KVA GENERAL LIGHTING .0035 KW SF x 607 SF x 1,25 2.66 5 RECEPTS Q 180 VA /1000 •9 HVAC 10.9 AUTOVENT I� SINK TOTAL 14.46 1 1/2" TOTAL /2400000 60.25 INSTALL 100 AMP PANEL 120/240V 10 1 1/2" ANY CHANGES OR REVISIONS CUSTOMER APPROVAL TO THIS FLOOR PLAN CLIENT; DESTINATION OR THE ORIGINAL QUOTE WILL RESULT IN ADDITIONAL DESIGN P, 0' DOUGLAS 912 384 -9211 CHARGES. SPACE 2008 GA. 31533 FAX 912 383 -7821 FAX 912 384 -9209 I JUAN ( REV19N # GE CAPITAL MODULAR SPACE MIAMI FL. 6 REVISION DATE. SIZE 24X60' i- -30 -04 SERIAL # 14055 DATE 10 -8 -2003 DRAWN BY M THOMAS RAWING TITLE DRAWING # I T14055AB CARPET EXTERIOR COLOR TRIM COLOR SCALE APPROVED BY TYPE =ecsl , CODES 3 16 1' FB C SEALS FL VCG OTHER LISTING AGENCY APPROVAL THESE PRINTS COMPLY WITH THE FLORIDA MANUFACTURED BUILDING ACT OF 1979 CONSTRUCTION CODES AND ADHERE TO THE FOLLOWING CRITERIA: CONST. TYPE VI OCCUPANCY B ALLOWABLE # OF FLOORS 1 WIND VELOCITY 146 FIRE RATING OF EXTERIOR WALLS 0 PLAN NO. MDS00362_7 ALLOWABLE FLOOR LOAD 50/100 APPROVAL DATE 01 31 2004 MANUFACTURER PER DCA LETTER APPROVED FOR HIGH VELOCITY WIND ZONE YES DESIGN SPACE INC. P.O. BOX 2008, DOUGLAS, GA. 31533 JOHN A. BODZIAK 36374TH STREET NORTH p SAINT PETERSBURG, FLORIDA 33704 A R C H I T rp�+ E C T LICENSE #AR-- 0005065 M.D.S. 2730 12TH STREET SOUTH M D S O V .J O SAINT PETERSBURG. FLORIDA 33705 LISTING AGENCY PHONE #813 --994-6004 DATE SCALE QUOTE SER. N0. 01/31/2004 — N TS— MDS003627 41�X 4 SIZE CO DE TYPE USE cNCcl- rr REV, APAGE PER PRINT 2001 FBC VI B MDS M 2 OF 4