10-1035-024GENERAL STRUCTURAL NOTES 1. PILE FOUNDATIONS: BASED ON SOIL BORINGS AND RECOMMENDATIONS MADE BY PROFESSIONAL SERVICE INDUSTRIES, THE FOUNDATIONS HAVE BEEN DESIGNED WITH AUGERCAST PILES, WITH THE FOLLOWING CAPACITY AND MINIMUM PILE PENETRATION DEPTHS. 16" DIAMETER, 125 TONS IN COMPRESSION, AND 80 TONS IN TENSION. 40' MINIMUM PENETRATION AND MINIMUM ROCK SOCKET 10 FEET. ALL COMPRESSION PILES SHALL BE REINFORCED WITH A CAGE OF 5 % VERTICAL BARS AND 03 1111 12" c/c TIES FOR THE TOP I5 FEET AND 1 09 THE FULL LENGTH OF THE PILE. ALL TENSION PILES SHALL BE REINFORCED WITH A CAGE OF 6 08 VERTICAL BARS AND 03 ID 12" c/c TIES FOR THE THE FULL LENGTH OF THE PILE. ALL PILES LABELED "TENSION" ARE TENSION PILES, AND MUST PROVIDE A MINIMUM 24" LENGTH OF EXPOSED PILE REINFORCING STEEL TO BE EMBEDDED IN THE PILE CAP. ALL PILES IN 1 -PC AND 2 -PC PILE CAPS MUST BE PROVIDED WITH A MINIMUM OF 24" LENGTH OF EXPOSED PILE REINFORCING STEEL TO BE EMBEDDED INTO THE PILE CAP (OR GRADE BEAM). 2. CONCRETE: ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 4,000 PSI IN 28 DAYS, EXCEPT FOR SLABS ON GRADE THAT SHALL HAVE AN ULTIMATE COMPRESSIVE STRENGTH OF 3,000 PSI IN 28 DAYS. AGGREGATES TO BE CLEAN AND WELL GRADED, MAXIMUM SIZE R ". CONCRETE SLUMP: 3" MIN. TO 5" MAX. VERTICAL CONCRETE DROP NOT TO EXCEED 8' -0" (UN.O.) 3. CONCRETE COVER- TO BE AS FOLLOWS: BOTTOM TOP SIDES FOOTINGS 3" 2" 31' GRADE BEAMS 311 211 211 WALLS - -- - -- 11/211 COLUMNS � MNS - -- - -- 111/2 BEA ► IS 1112II 11/2II 111/211 SLABS 111 III III 4. REINFORCING STEEL: TO BE NEW HIGH STRENGTH BILLET STEEL DEFOFTIED AS PER ASTM A- 305, AND CONFORMING TO ASTM A -615, GRADE 60. LAP CONTINUOUS TOP AND BOTTOM BARS 48 -5AR DIAMETERS, AT MID - SPAN FOR TOP, AND AT SUPPORTS FOR BOTTOM. PROVIDE "L" BARS 30" X 30" FOR TOP AND BOTTOM BARS, AT ALL CORNERS OF ALL TIE BEAMS. HOOK DISCONTINUOUS ENDS OF ALL TOP BARS FOR STRUCTURAL BEAMS (NON TIE - BEAMS). REINFORCING STEEL TO BE DETAILED AND FABRICATED IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE OF DETAILING REINFORCING CONCRETE STRUCTURES ", AND THE ACI BUILDING CODE 318, LATEST EDITION. SUBMIT SHOP DRAWINGS FOR APPROVAL. 5. MASONRY: A. ALL CONCRETE BLOCK TO BE GRADE N -2, CONFORMING TO ASTM C -90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1,900 PSI, AND A PRISM STRENGTH OF 1,500 PSI (MINIMUM). MORTAR SHALL BE TYPE M, WITH A MINIMUM STRENGTH OF 2,500 PSI (USE PORTLAND TYPE CEMENT). TEST MASONRY UNITS AND MORTAR BY TESTING: LAB AT A RATE OF EVERY 1,000 SQUARE FEET OF WALLS ERECTED. B. MASONRY WALLS SHALL BE REINFORCED HORIZONTALLY WITH 8 GAUGE DEFORMED GALVANIZED STEEL, SPACED AT 16" C/C VERT. EXTEND HORIZONTAL REINFORCING 4" INTO ADJACENT COLUMNS. PROVIDE TRUSS TYPE FOR NON - REINFORCED MASONRY AND LADDER TYPE FOR REINFORCED MASONRY. C. FOR VERTICAL REINFORCEMENT, SEE SCHEDULE AND LAP 48 BAR DIAMETERS MINIMUM. PROVIDE FULL BED OF MORTAR FOR REINFORCED MASONRY. D. A TIE- BEAM 8" X 12 ", WITH FOUR "5 CONT. AND 03 TIES AT 48" C /C. BEAM MUST BE DOWELED INTO WALLS AT EACH END, AND AT INTERSECTIONS. AT INTERMEDIATE POINTS, PROVIDE LATERAL BRACING, AS SHOWN IN DETAILS IN PLANS. E. PROVIDE CLEANOUTS WHEN GROUTING BLOCK CELLS, AND CLEAN OUT BLOCK CELLS OF ALL MORTAR DROPPINGS. MAXIMUM VERTICAL DROP FOR GROUTING IS 4' -011. F. AT THE END OF EACH DAY COVER ALL MASONRY WALLS. 6. STRUCTURAL STEEL: SHALL CONFORM TO ASTM A512, GRADE 50, DETAILED, FABRICATED AND ERECTED IN ACCORDANCE AISC SPECIFICATIONS, LATEST EDITION. STEEL TUBES TO CONFORM TO A -500, GRADE B (fy= 46 KSI). SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATION. ALL STRUCTURAL STEEL EXPOSED TO THE ELEMENTS TO BE HOT DIPPED GALVANIZED. i. WELDING: ALL WELDING TO BE DONE BY DADE COUNTY CERTIFIED WELDERS HOLDING CURRENT WELDING CERTIFICATES, AND MUST PRESENT SAME AT JOB SITE AT ALL TIMES. ALL WELDING PER PLANS AND PER GUIDELINES OF THE AMERICAN WELDING SOCIETY. 8. WIND DESIGN CRITERIA: ALL STRUCTURAL ELEMENTS, EXPOSED TO WIND, HAVE BEEN DESIGNED PER THE GUIDELINES OF THE ASCE 1-2002 BUILDING CODE. FOR WIND UPLIFT ON THE ROOFS, SEE INDIVIDUAL ROOF PLANS FOR DIAGRAMS AND TABLES DICTATING THE ZONES AND THE NET UPLIFT FORCES. 9. SLABS ON FILL: FILL AND BACKFILL TO BE COMPACTED UNDER THE SUPERVISION OF A SPECIALTY ENGINEER TO A MINIMUM OF 95% OF MAXIMUM DRY DENSITY FOR ALL LAYERS AS VERIFIED BY FIELD DENSITY TESTS. TESTS SHALL BE MADE IN ACCORDANCE WITH METHODS OF TESTS FOR MOISTURE DENSITY RELATIONS OF SOILS, ASTM D -1551 MODIFIED TO USE 25 BLOWS ON FIVE LAYERS WITH A 10 POUND HAMMER DROPPING 18 INCHES. IN ADDITION, A MINIMUM OF ONE IN -PLACE FIELD DENSITY TEST SHALL BE PERFORMED FOR EACH 2500 SQUARE FEET, OR FRACTION THEREOF, FOR EACH LIFT OF COMPACTED SOIL, AND SUCH TESTING SHALL BE PERFORMED IN ACCORDANCE WITH EITHER ASTM D 1556, STANDARD TEST METHOD FOR DENSITY OF SOIL IN- PLACE BY THE SANDCONE* OR ASTM D 2522, STANDARD TEST METHODS FOR DENSITY OF SOIL AND SOIL AGGREGATE IN PLACE BY NUCLEAR METHODS OR OTHER APPROVED METHODS. COMPACTION LAYERS NOT TO EXCEED 12 ". BACKFILL MATERIAL TO BE APPROVED BY SOIL ENGINEER SLABS TO BE PLACED CONTINUOUSLY, HOWEVER, MUST BE SAW CUT SAME DAY IT 15 PLACED AND LIMITED TO 400 SF, AND 15 FEET IN ANY DIRECTION. COORDINATE WITH ARCHITECTURE FOR LOCATIONS OF THE SAW CUTS. SUBMIT LAYOUT OF ALL SAW CUTS FOR APPROVAL. SAW CUT TO BE A MINIMUM OF 1 INCH DEPTH AND 114 INCH WIDTH. PROVIDE VAPOR BARRIER BELOW ALL SLABS ON FILL (10 MIL). REFER TO ARCHITECTURE FOR REQUIRED SOIL POISONING BENEATH ALL SLABS ON GRADE. 10. EXCAVATIONS: GENERAL CONTRACTOR TO NOT EXCAVATE ADJACENT TO OR NEAR NEW STRUCTURES AFTER THEY HAVE BEEN CONSTRUCTED. EXCAVATIONS FOR UTILITIES ADJACENT TO OR NEAR NEW STRUCTURES TO BE COMPLETED BEFORE THE NEW STRUCTURES ARE CONSTRUCTED. COORDINATE ALL UTILITIES WITH STRUCTURAL DRAWINGS. IF CONFLICTS EXIST CONTACT ARCHITECT AND STRUCTURAL ENGINEER. GENERAL CONTRACTOR TO EXERCISE CAUTION DURING EXCAVATIONS ADJACENT TO THE EXISTING STRUCTURES. IF THERE EXISTS A DEVIATION OF THE EXISTING FOUNDATION FROM WHAT 15 SHOWN IN THESE PLANS, CONTACT ARCHITECT AND STRUCTURAL ENGINEER GENERAL CONTRACTOR IS SOLELY RESPONSIBLE FOR THE BRACING AND LATERAL SUPPORT, AND FOR MAINTAINING THE INTEGRITY OF THE EXISTING STRUCTURE DURING ALL PHASES OF THE CONSTRUCTION. 11. SHOP DRAWINGS: NO SHOP DRAWING SHALL BE SUBMITTED FOR ARCHITECT/ENGINEER'S REVIEW UNTIL AFTER THEY HAVE BEEN REVIEWED AND NOTED FOR CONSTRUCTION METHOD, DIMENSIONING, AND OTHER TRADE REQUIREMENTS BY THE CONTRACTOR, AND STAMPED WITH THE CONTRACTOR'S APPROVAL SEAL. ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS, QUANTITIES, ERRORS OR OMISSIONS, AS A RESULT OF CHECKING AND REVIEWING ANY SHOP DRAWINGS. 12. METAL STUDS: SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (LATEST EDITION) AS FOR FABRICATION, ERECTION AND DETAILING. STEEL STUDS TO BE HOT DIPPED GALVANIZED, WITH G -90 GALVANIZING, AS PROVIDED BY DALE INDUSTRIES. PROVIDE Fy = 33 KSI MINIMUM YIELD STRESS FOR 18, 20, 22, AND 25 GAUGES. PROVIDE N = 50 KSI MINIMUM YIELD STRESS FOR 16, 14, AND 12 GAUGES. SUBMIT MILL REPORTS AND SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATION. PROVIDE MINIMUM 20 GAUGE METAL CEE- STUDS 11 -5/8 X 3 -5/8 ") SPACED AT 16" C /C, FOR ALL INTERIOR PARTITIONS, AS INDICATED IN THE ARCHITECTURE. NOTE, IF ARCHITECTURE DENOTES A HEAVIER GAUGE OR CLOSER SPACING, THEN USE THE HEAVIER GAUGE AND CLOSER SPACING. 13. DEWATERING: ( IF APPLICABLE ) MUST EVACUATE ALL WATER FROM WITHIN FORMWORK BEFORE PLACEMENT OF ANY CONCRETE. AFTER DEWATERING AND BEFORE PLACING CONCRETE, MUST RINSE THE REINFORCING STEEL CLEAN OF ALL DELETERIOUS MATERIAL IF PREVIOUSLY LEFT SUBMERGED. 14. DETAILS AND SECTIONS: ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL, AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, UNLESS A DIFFERENT DETAIL, OR SECTION, IS SHOWN. 15. GENERAL: IF ANY ERRORS OR OMISSIONS APPEAR IN THE DRAWINGS, SPECIFICATIONS, OR OTHER DOCUMENTS, THE CONTRACTOR MUST NOTIFY THE ARCHITECT AND ENGINEER, IN WRITING, OF THE SAME PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. IN THE EVENT THAT THE CONTRACTOR FAILS TO GIVE NOTICE, OR PROVIDE SUFFICIENT TIME FOR A RESPONSE, CONTRACTOR IS RESPONSIBLE FOR THE RESULTS OF SUCH ERRORS OR OMISSIONS, AND FOR ALL COSTS FOR RECTIFYING SAME AND FOR ANY DELAYS OR ANY OTHER COSTS INCURRED BY SAME. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, OPENINGS, REGLETS, BOLT SETTINGS, SLEEVES, DIMENSIONS, ETC- POTENTIAL CONFLICTS SHALL BE TRANSMITTED TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE WORK. CONTRACTOR TO PROVIDE ADEQUATE TIME FOR RESPONSE FROM ARCHITECT/ENGINEER 16. SHORING: AND RE- SHORING: CONTRACTOR WILL PROVIDE SHORING AND RE- SHORING DRAWINGS, ALONG WITH RE- SNORING SCHEDULE FOR ALL ELEVATED STRUCTURAL COMPONENTS, INCLUDING BUT NOT LIMITED TO: BEAMS, SLABS, AND PRECAST JOISTS. DRAWINGS TO BE SIGNED AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER, FOR REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER NO ELEVATED WORK MAY PROCEED WITHOUT THIS SUBMITTAL AND ITS APPROVAL BY ARCHITECT AND ENGINEER. CONTRACTOR TO ALSO RETAIN SAME ENGINEER TO PROVIDE FIELD INSPECTIONS, ALONG WITH REPORTS, THAT ALL OF THE SHORING AND RE- SHORING IS COMPLETED AS PER HIS DRAWINGS AND SPECIFICATIONS, FOR EACH LEVEL OF WORK SHORING SCHEDULE TO PROVIDE TIME THAT SHORES MAY BE REMOVED IN ORDER TO REMOVE FORMWORK NOTE, IF THESE SHORING AND RE- SHORING CONFLICT WITH ANY DIRECTIVES CONTAINED IN THE JOB SPECIFICATIONS, THEN THE GOVERNING GUIDELINES WILL BE THESE. 11. CONSTRUCTION JOINTS: FOR CONSTRUCTION JOINTS IN SLABS ON FILL REFER TO SLABS ON FILL SECTION AND COORDINATE WITH ARCHITECTURE. FOR BEAMS, PROVIDE BULKHEADS AT MID -SPAN OF BEAM, AND PROVIDE BEAM POCKET, 4" DEEP X 2/3 DEPTH OF BEAM X 2/3 WIDTH OF BEAM, CENTERED IN THE BEAM. PROVIDE EXPOSED REINFORCING TO ADEQUATELY SPLICE THE REINFORCING FOR A CLASS "C" TENSION LAP SPLICE. FOR SLABS, PROVIDE BULKHEADS AT A MID -SPAN LOCATION OF SLAB, AND PROVIDE A CONTINUOUS SHEAR KEY, CENTERED IN THE SLAB FACE. PROVIDE EXPOSED REINFORCING STEEL TO SPLICE THE REINFORCING. CONTRACTOR TO SUBMIT, FOR APPROVAL, LOCATIONS OF BULKHEADS FOR ALL STRUCTURAL ELEMENTS THROUGHOUT JOB, PRIOR TO COMMENCEMENT OF ANY WORK 15 PREFABRICATED METAL STAIRS/I..ADDERS: ( IF APPLICABLE ) CONTRACTOR TO PROVIDE FOR ALL PRE - FABRICATED METAL STAIRS AND METAL LADDERS, SIGNED AND SEALED SHOP DRAWINGS, BY FLORIDA REGISTERED PROFESSIONAL ENGINEER, FOR APPROVAL BEFORE FABRICATION. CONNECTIONS OF THESE STAIRS AND LADDERS ALSO TO BE INCLUDED IN THE SHOP DRAWINGS. 19. PRE- FABRICATED CANOPIES: IF APPLICABLE ) CONTRACTOR TO PROVIDE SIGNED AND SEALED SHOP DRAWINGS, BY A FLORIDA REGISTERED PRDFESSIONAL ENGINEER, FOR THE COMPLETE CANOPY ASSEMBLY INCLUDING : ROOF SYSTEM, CONNECTIONS, COLUMNS, AND FOUNDATION CONNECTIONS. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. DESIGN TO BE IN ACCORDANCE WITH ANSI -A58.1 -1982 WIND LOADING REQUIREMENTS, FOR LATERAL AND UPLIFT, AND GRAVITY LOADS. 20. PRE- FABRICATED GLASS CURTAINS WALLS AND FIXED AND SLIDNG GLASS DOOR SYSTEMS: ( IF APPLICABLE ) CONTRACTOR TO PROVIDE SIGNED AND SEALED SHOP DRAWINGS, AND SIGNED AND SEALED CALCULATIONS, BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER, FOR THE FOLLOWING ITEMS: 1. THE COMPLETE GLASS CURTAIN WALL ASSEMBLY AND COMPONENTS INCLUDING: GLASS, CONNECTIONS, AND FRAMES. SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION. 2. ALL FIXED AND SLIDING GLASS DOOR SYSTEMS /ASSEMBLIES INCLUDING: GLASS, CONNECTIONS, AND FRAMES. DESIGN TO BE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE CONSTRUCTION GUIDELINES. 21. GROUTING WITH HIGH STRENGTH NON - SHRINK GROUT: USE OF A HIGH STRENGTH NON - SHRINK GROUT TO BE USED AS INDICATED IN THESE DOCUMENTS, OR AS REQUIRED FOR STRUCTURAL REPAIRS OR PATCHING. USE MASTER=LOW 928 OR EQUAL (SUBMIT TO ENGINEER FOR SUBSTITUTION). GROUT TO BE MIXED AS PER RECOMMENDATIONS OF MANUFACTURER AREAS TO GROUTED MUST BE THOROUGHLY CLEANED OF ALL DEBRIS AND DELETERIOUS MATERIALS. GROUT THICKNESS TO BE AS SHOWN IN DOCUMENTS, HOWEVER, THICKNESS NOT TO EXCEED RECOMMENDATIONS OF MANUFACTURER. IF REQUIRED, PROVIDE SEVERAL LAYERS, AS REQUIRED, IN ORDER TO ATTAIN REQUIRED TOTAL THICKNESS. 22. ANCHORING EPDXY: FOR ANCHORING REINFORCING STEEL IN EXISTING CONCRETE USE HILTI HIT HY 150 INJECTION ADHESIVE ANCHOR OR EQUAL. OTHER AVAILABLE EPDXIES ARE MADE BY ULTRA BOND OR RAWL. DRILL HOLES 1/8" BIGGER THAN THE DIAMETER OF THE REINFORCING STEEL (STEEL ROD). THE DEPTH OF THE HOLES ARE TO BE A MINIMUM OF 5 ", UNLESS OTHERWISE NOTED IN THESE PLANS, OR UNLESS' OTHERWISE INSTRUCTED BY THE MANUFACTURER'S RECOMMENDATIONS. 23. EXPANSION BOLTS: ALL EXPANSION BOLTS, NOTED IN PLANS, ARE TO BE HILTI TYPE EXPANSION BOLTS, OR EQUAL. FOR SUBSTITUTION, SUBMIT TO STRUCTURAL ENGINEER FOR REVIEW AND HIS APPROVAL. I: IF- O z I ral TYPICAL STEEL COLUMN 70 GRADE BEAM D E T A I L 6.10E SGALE = N.T.S. — STD. 90° HOOK r II � I II II I I I STD. 900 HOOK ARCHITECT: �r I -lbcq - 'BERMELLO AJAMIL & PARTNERS, INC. Architecture Engineering Planning Interior Design Landscape Architecture 9_n01 Sc*uth Bays4iore-Drive 10th Floor n IMiami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 .!-+ 1-1 III �.VJ -ul 11� 7Cit-t�1JUL� - ? FOR COL. TIES, SEE TYPICAL COLUMN DETAILS. - 0 @ cat D MAX. SLOPE 1 IN 6 d� a fn III - I I ' o I1 =1 I I a cn —I PILE CAP SIZE, STD. 90 HOOK 4 REINFORCING LU AS SCHEDULED - d 311 TYPICAL COLUMN TO PILECAP DETAIL DETAIL 6.10E SC:,4LE = N.T.S. PLANNING ARCHITECT: 30 %E ■ IN WILMOT SANZ A R C H I T E C T U R E P L A N N I N G 18310 Montgomery 27" Avenue Gaithersburg. ar7d 20879 301 -590 -2900 (Fox 301 -580 -8150 STRUCTURAL ENGINEER: ' �tQr4&JLFT %lNELR&EEi41' ❑RAMON R. DONNELL PE. 0017680 CML /STFUCTURAL OAIDA M. ■PgpEDSRwO J. DUOUESNE0.cP�p�,WW A J . W 61 eee- oTittl' OT!SMAM. P.E. 0045130 �W! -6S6a t" STATE OF R.OMA - AMOMATt077 N. TM 08+2-c 2008 MEP ENGINEER: AltAbdo 2121 Ponce de Leon Blvd., Suite 350, Coral Gables, FL 33134 k7m—rd ConyAW'g neen 1 phone: 305.569.1692 fax: 305.569.1693 Dallas . Houston . Nashville . Miami . Richmond cord project number. IT CONSULTANT: V ENE BURTON & ASSOCIATES 3 General George Patton Drive 5848 west 1 -20, Suite 150 klin,Tenrrersee37067 Arlington, Texu76017 w :615.3763100 Phone. :817.5632486 : 615.376.3114 Far 817.563.2753 .ure: -- gbaire_cam Medical Equipment and Communications Planners ��ORp J. DUQ��� LU PERMIT SET I REVISIONS: PROJECT NAME: SMH- CLINICAL EXPANSION FOUNDATION PACKAGE PHASE 11 PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 UU M NI. 114U. 40U51.100 SCALE: AS SHOWN DATE: 07-09 -2010 DRAWN: CHECKED: BH CADD FILE: MINSTITUTIONAL DRAWING TITLE: GENERAL STRUCTURAL NOTES & TYPICAL DETAILS �M:lA:1r.[.j ��Tbej"f