Loading...
10-1035-0195 8' -2" 14' -10" 71-ON 0 C 30' -0" 30' -0" I 30' -6" I r b ♦ FOR CON INUATION SEE SHEET S1.11F _J V FOR CON INUATION SEE SHEET S1.12F 7 E i 9 0 I 0 M O rri 0 I CD n 10 cV I 0 /i O O O II II E3 111 I L � I I I I i� I I I I I NEW ISTI I II r-- - - - --I F_ - - - --I I-- --) GB -3 I I- _ ­I__ _ L_J t- - - L_ J 2PC I L — —J I-- —J - - - -- I I 5PC 6PC 6PG 5PC EXIST G' – – – – - I I I I I I I I PILE G�4P ;III - -Tf EL. –I- 1-011 —± I PLAN NOTES: 1.- TOP OF SLAB ELEVATION 0' -0" = 0' -0" (ARCHITECTURE) I i I N15W - EXISTING TYPICAL UNLESS OTHERWISE NOTED AS THUS d% _ -{- EL. 0' -0" (DATUM) = + 0' -0" (ARCHITECTURE)) -- ---- - - - - -- / 1 2: TOP OF PILECAP ELEVATION AS FOLLOWS: ---� I EL. -2' -0" (REF: EL.O' -0") i J - _ - - - - --I - - - - - - - ` TYPICAL UNLESS OTHERWISE NOTED AS THUS 2PC ( I I I ( I I I J 1 3: CENTERLINES OF ALL COLUMN PIERS SHALL COINCIDE WITH L — — — — — — J — — — — _J — — 3PC I THE FOUNDATION CENTERLINES UNLESS SHOWN OTHERWISE. 5Pc 6PC 6PC 5PC I 4.- FOR GENERAL STRUCTURAL NOTES SEE DRAWING 56.10F I I 5.- FOR PILECAP DETAILS SEE DRAWING 56201= 6.- FOR COLUMN SCHEDULES SEE DRAWING S&AOF I.- FOR CONCRETE WALL SCHEDULE SEE DRAWING 5630F FOR GRADE BEAM SCHEDULE SEE DRAWING S&AOF S.- G.G. TO FIELD VERIFY EXISTING FOUNDATION ELEVATIONS. 10.- 0 DENOTES ONE PILE, SEE GENERAL STRUCTURAL NOTES SHEET 56.10F, NOTE I III I I I I I F- — — -1 I- — — -I F_ — ___71 771 r7 —11 r- 2PC I 5PC 5PC 5PC 5PC , TSLJ w �I cci 26 PC (601) GB -1� I 2PC SEE SHEET 56.60 �-�- I2PG -� 5330E DETAIL (= t UP I J 9'_0 5620F t>a l i 1 I- - - - I - - - = I 2PC G 24 2 II I I I I I f ( to to I O 3Pc I P o +�- —� -- -- - - - --� _ E3 L 11J 1 I I I SHEARWALL 18 - _ _ - - - - -- ---- - - - - -- - -- - - --J -� ----------------------- --- - - - - -- - - - - -- - - - -- - -- -- - - - - -- - - - -� ----- - - - - -- 2PC G5-1 GB -1 E-- W -1 I z GB -1 W -1 1II I II EL.40',, II t _ D., EXISTING ,�LA5� 1- I �: r LL, 5 30F I I I I�--i U, 0 C------ --� 0 ,I PARTIAL FOUNDATION AND GROUND FLOOR PLAN VLAU SCALE: 1/8" = 1' -0" ARCHITECT: n BERMELLO AJAMIL & PARTNERS, INC. Architecture Enc ineering Planning Interior Design Landsc -ape Architecture 2fi01 South Eaxshp! Drive 10th Floor Miami, Florida 33133 (305) 859 -2050 Fax (305) 860 -3700 PLANNING ARCHITECT: 3,17AN 0 12 WILMOT SANZ A R C H I T E C T U R E P L A N N I N G 18310 Mont 20879 301- 5G9a0 fth-2a9s0b (eF 2 3-5A9ve0 n—u 8e 1 30 STRUCTURAL - ENGINEER: $tQi4SirL NIEINE N4 EDq / ❑RAMON R. DONNELL P.E. 0077680 �1 C{rm /S0eTp crua6AL ` _ ■PEDRO J. DUQUESNE bm'Eir$fflTutiA4i ❑AIDA M. ALBAISA PE 0045730 �p'p gyy 7.{ cmirsrm�ruui 4706! 5560711th OT. MAM. FLW M R TA-M OF FOOA - At80ATN s =6 RZZ MEP ENGINEER: 2121 Ponce de Leon Blvd., Suite 350. Coral Gables, FL 33134 phone: 305.569.1692 erne° on sneers fate 305.569.1693 Dallas . Houston . . Miami . Richmond ccr project number. IT CONSULTANT: GENE BURTON & ASSOCIATES 1893 General George Patton Drive 5840 West 1-20, Suite I50 FrankliMTennw;ee37067 Arlington,Texu76017 PMne:6153763100 PA. 8 17-5632486 Far: 615.3763114 F=817.5632753 Web,im: ­gbaiw om Medical Equipment and CommunicatiowPlanners t� e•' 14 ►, i µ CN4=. W ..,. -4, .1 NO u �A 17Igk4t`, PERMIT SET PROJECT NAME: SMH- CLINICAL EXPANSION FOUNDATION PACKAGE PHASE II PROJECT ADDRESS: 7400 S.W. 62nd Ave. South Miami, Florida 33143 C<9MM. NO. 40051.100 SCALE: AS SHOWN DATE: 07-09 -2010 DRAWN: CHECKED: BH CADD FILE: H:INSTITUTIONAL DRAWING TITLE: PARTIAL FOUNDATION AND GROUND FLOOR PLAN SHEET NO. 51.12E