Loading...
09-98-001C 1ST FLOOR F PLAN .,.�.,....�.....,,.., -- —. _ SCALE: 1 /8„ = 1'0" w�^7�11r�t cRY5'TALENE (i 24X36 ENGINEER'S INFORMATION: COMPANY GPM ENGINEERING, INC. NAME: SHANTJLAL C. PATE.L. ADDRESS: 5502 S.W. 114 AVENUE _COOPER CI -Y, FR ORiDA 330T ' KIND OF ENGINEER: MECHANICAUELEC;TRICAL,E GIN R ;. LICENSE NUMBER: P.E. # 028551 - .,SIGNA 1 U"a 2E KEY PUN LEGEND all SYMBOL DESCRIPTION OF DEVICE MANUFACTURER MODEL WE,ATHEiIUT IlA F S'IJRF CE WEATHERPROOF COVER F A C P Existing Fire Alarm Control Panel FARADAY FIREWATCH VIII N/A NIA N P E & P New Power Expander Control Panel Relocating Existing Remote Annunciator FIRELITE FARADAY FCPS -24FS6 7716 -01 �- N/A NIA N/A NEMA -4X R R A Existing Pull Station FARADAY F2GT N/A N/A NF New Pull Station FARADAY F2GT - N/A - N/A .- .. -..... New Weather Proof Pull Station FIRELITE BG -12LOB WBB N/A RF Relocating Existing Pull Station FARADAY F2GT N/A � N/A S Existing Smoke Detector SYSTEM SENSOR 1224THB N/A N/A NS New Smoke Detector SYSTEM SENSOR 4WTR -B N/A N/A T Existing Heat Detector CHEMITRON 601 N/A N/A Existing Horn /Strobe (wall mount) FARADAY 6020/5511 NIA - N/A 11 ff NH New Horn /Strobe ( wall mount) SYSTEM SENSOR P2R -w N/A N/A .r.rr., -mow Ni.P. NH New Weather Proof Horn /Strobe ( wall mount } SYSTEM SENSOR P2RK_* WBB -R N/A .`�,ew Horn /Strobe ( ceiling mount) SYSTEM SENSOR PC213 N/A N/A NL W P. sec} >ew Weather Proof Strobe Light ( ceiling mount) SYSTEM SENSOR SCRK WBB -R N/A ')COPE OF WORK 1) Installing additional Notification Appliances to the existing Fire Alarm System as required by code 2) The additional Notification Appliances will be installed as per the Manufacturer Specifications, the NFPA -101, the NEC -70, the NFPA -72 and as per the Local Authority Having Jurisdiction 3) Installing additional Initiating Devices to the existing Fire Alarm System as required by code 4) The additional Initiating Devices will be installed as per the Manufacturer Specifications, the NFPA -101, the NEC -70, the NFPA -72 and as per the Local Authority Having Jurisdiction 5) The Initiating Devices that will be relocated will be installed as per the Manufacturer Specifications, the NFPA -10^ , the NEC -70, NFPA -72 and as per the Local Authority Having Jurisdiction 6) Will do the following to the existing Fire Alarm System, inside the remodeling area which includes the Gym Area, the Men's Locker Room, Women's Locker Room, Phone /Data /Fire Alarm Area and the Electrical Panel Area: a) Add one Power Expander Control Panel with Backup Batteries b) Relocate one existing Remote Anninciator outside building ( inside a weather proof housing ) c) Relocate one existing Pull Station d) Add one new Pull Station e) Replace and install at correct height one Pull Station with a weather proof Pull Station f) Add one Smoke Detector g) Remove two existing Smoke Detectors h) Add one Horn /Strobe ( wall mount ) i) Replace and install at correct height one Horn /Strobe with a weather proof Horn Strobe j) Add one Horn /Strobes ( wall mount ) k) Add five Horn /Strobes ( ceiling mount ) 1) Add six weather proof Strobe Lights ( ceiling mount ) m) Add four Strobe Lights ( ceiling mount ) nF.gr.RIPTION OF THE BUILDING 1) The existing building consists of an Open Parking Structure 2) The Re- modeling Area is limited to a section on the 1st floor of the Open Parking Garage, which includes the following: a) Gym Area b) Men's Locker Room c) Women's Locker Room d) Data /Phone /Fire Alarm Area i e) Electrical Panel Area 13) The type of occupancy for the building is: a) Business Occupancy 4) The area where the job is being done will be used as follows: a) Fitness Center, Showers and Restrooms 5) The Re- modeling Area has approximately 940 square feet 6) The Fitness Center and Facilities Area has approximately 71 i square feet 7) The Fitness Center and Facilities Area are located on a section of the Open Parking Garage's 1st floor, the building is approximately 64 feet high i) The building elevation of the highest occupied floor is five stories fl) The building has no Sprinkler System through out all occupied areas in the building 10) The building elevator shafts do not have a Sprinkler System 11) The building does not have a Fire Pump 12) The building has an Emergency Generator 13) The building does not have a Hood Extinguishing Systems 14) The building does not have a FM -200 Extinguishing Systems BURGLAR; ALARM SERVICES 5650 SHERIDAN STREET HOLLYWOOD, FLORIDA 33021 -32510 PHONE: (945) 963 -3356 FAX: (954) 981 -4302 STATE LICENSE: EF0000228 QUALIFIER'S INFORMATION: NAME: BRUCE HOTCHKISS _ ADDRESS: 5650 SERIDAN STREET HOLLYWOOD, FLORIDA 33021 LICENSE NUMBER: EFO000228 _ f� W `3; :,. �,% .Y' yr- ✓ .- r"�.+. .: .a r° -. w ,SIGNATURE THE EXISTING FIRE ALARM CONTROL PANEL, THE EXISTING FULL STATIONS THE EXISTING SMOKE DETECTORS AND THE EXISTING NOTIFICATION APPLIANCES DO NOT HAVE CUT SHEETS FROM THE MANUFACTURER, SINCE THEY ARE NO LONGER MANUFACTURER AND HAVE BEEN DISCONTINUED SOUTH MIAMI HOSPITAL FITNESS) CLNTI'' F' 6200 S.W. 73 STREET SOUTH MIAMI, FLORIDA 3.3143 Scale: 1r - 1/S),, Approved by: — Drawn by: J•B. Date: 12/19/08 SHANTJAIICL C. PATEL Re ise'd: BURGLAR ALARM SERVICES 5650 SHERIDAN STREET, KOLLYWOOD, FI,ORII)A 33021 1'OF4 t4Ait7E 1N U.`,.A.