Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-979-029
0- U v U cN U N ca a cv Ln a z 0 m En a. w I n U E 0 0 C1_ 0 n' F-- Q I �n 0 0 C_ n cn I C 0 D I CD N J SEE SPECS FOR ROD SIZES INSULATION CHW LINES (SEE MECHANICAL DWGS. FOR SIZE AND ROUTING) CONCRETE SUB STEEL RODS W /THREADED ENDS (TYP. 4 PLACES) SUPPORT FROM STRUCTURE ABOVE AS REQUIRED VIB. ISOLATORS ADJUSTABLE SWIVEL PIPE ROLL WITH SA ROLLER HANGER ADJUSTABLE SOCKETS SIZES 4" UP TO 8" SIZES 8" AND ABOVE A 4B PIPE HANGER SIZES RA (SEE SPECS.) .............. 4A 2 1 FLOAT SWITCH � n a Q :( Cr CORNERS ARE ca PIPE SADDLE HAS FLARED CLIPPED EDGES NOTCHED TO FIT PIPE HANGER. ROUTE MAIN CONDENSATE LINE TO PLUMBING COND. 4C SYSTEM. SEE DRAWINGS GALVANIZED SHEET METAL SECONDARY PIPE FOR LOCATION AND SIZE SADDLE A DRAIN PAN TO EXTEND 3" BEYOND UNIT (TYP.) SECTION A -A ON ALL SIDES BY 11/2" DEEP. MAINTAIN ACCESS TO UNIT FILTER. FLARED END FLARED EDGES ALL INSULATION PASSES THRU HANGER UNBROKEN (REF. UL SYSTEM #C —AJ -1026, 1997) LENGTH =TWICE Notes: INSULATION O.D. SIZES UP TO 3" Floor or Wall Ass embl — Min. 4 1/2 in. thick lightweight or normal weight (100- 150 pcf) concrete with a max. 15 in. dia. opening. �2Steel Pipe or Conduit — Nom. d in. dia. (or smaller) Schedule 10S (or heavier) steel INSULATEDPIPE HANGER 4 pipe or rigid galvanized Steel conduit centered in the opening. A max. of one pipe FAN COIL UNIT No Scale or conduit is permitted in the fire --stop system. No Scale Pie Covering Material — Optional — The following types of pipe covering may be used: A. Nominal 2 in. thick hollow cylindrical heavy density (min. 3.5 pcf) glass fiber units jacketed on the outside with a PVC facing. Longitude joints sealed with metal fasteners or factory applied SSL. Transverse joints sealed with metal fasteners or with butt strip tape supplied with the product. B. Nominal 1 in, thick hollow cylindrical heavy density (min. 6 pcf) hydrous calcium AUTOMATIC FLOW CONTROL PRESSURE GAUGE Ec COCK (TYP.) silicate units covered with a PVC facing pipe insulation secured together with DEVICE PRESET BY MANUF. steel —tie wire. W/ P do T TEST PORTS, See Pipe and Equipment Covering Materials — (BRGU) category in Building Materials Directory for names of manufacturers. Any pipe covering meeting the above STRAINER, AND DRAIN. THREE WAY specifications and bearing the UL Classification Marking. (PRE -MANUF. SINGLE CONTROL VALVE Fire—Stop S tem — The hourly T— rating of the fire —stop system is dependent upon ASSEMBLY ACCEPTABLE) MANUAL AIR VENT W /AUTO the size of the pipe or conduit, the type of pipe covering (Item 3) the presence or SHUT -OFF COCK absence of pipe covering, and annular space between the periphery of the opening COIL and pipe covering and annular space within the opening. (PRE- MANUF. SINGLE Max. pipe or Typ. of Thickness of Annular T ASSEMBLY ACCEPTABLE) Conduit Dia. Pipe Covering Pipe Covering Space Rating E" CS 1" 11/2" 11/2 h a" FG 2" 1/2" 1 h E" — - 21/2" 0 h RETURN FILTER (a) CS = Calcium silicate Ir \ FG = Fiberglass RETURN AIR C o Insulation — ceramic fiber blanket nom. 1 in. thick, min. 1 pcf density wrapped around © the circumference of the pipe or conduit and secured together by means of fiber— I i lass tape. Blanket position such that it extends a min. of 2 in. beyond both sur- 9 SUPPLY PLUG � faces of the floor or wall assembly. COCK 000 4@ Fill, Void, or Cavity Material — Blanket* — Blanket wrapped around the circumference DPS -1 TS-2 of the pipe and insulation with vertical seams overlapping 1 in. Position blanket within the opening such that it extends a min. of 4 in. beyond both surfaces and secured SHUT-OFF VALVE (TYP.) DI together with metal staples and plastic cable ties. AI @ Fill, Void, or Cavity Material — Mastic* — Material that is troweled or applied with a / P T TEST PORTS caulking gun to fill the annular space between the blanket and the periphery of the U opening. Min. thickness shall be 4 -1/2 in. h I AIR FLOW A0 STRAINER W / SLOWDOWN UNION (TYP.) Al THERMOMETER W /SEPARABLE WELL (TYP.) FLEX. CONNECTION (TYP.) CHWR CHWS STS -1 NOTES: 1. PROVIDE (4 x DIA.) OF STRAIGHT PIPE ON BOTH SIDES OF BALANCING VALVE 2. ALL COMPONENTS FULL LINE SIZE UNLESS NOTED OTHERWISE 3. LOCATE UNIONS TO ALLOW FOR COIL PULL FIRE RATED FLOOR /WALL PIPE PENETRATION 3 -WAY COIL PIPING DIAGRAM 2 FAN COIL UNIT 5 3 No Scale W/INSULATION No Scale ••(f• i•• o • ••••• ••• • Issue Date: `1 ( FAN Y Y ,ti • RA (SEE SPECS.) .............. 4A 2 1 FLOAT SWITCH � n a Q :( Cr CORNERS ARE ca PIPE SADDLE HAS FLARED CLIPPED EDGES NOTCHED TO FIT PIPE HANGER. ROUTE MAIN CONDENSATE LINE TO PLUMBING COND. 4C SYSTEM. SEE DRAWINGS GALVANIZED SHEET METAL SECONDARY PIPE FOR LOCATION AND SIZE SADDLE A DRAIN PAN TO EXTEND 3" BEYOND UNIT (TYP.) SECTION A -A ON ALL SIDES BY 11/2" DEEP. MAINTAIN ACCESS TO UNIT FILTER. FLARED END FLARED EDGES ALL INSULATION PASSES THRU HANGER UNBROKEN (REF. UL SYSTEM #C —AJ -1026, 1997) LENGTH =TWICE Notes: INSULATION O.D. SIZES UP TO 3" Floor or Wall Ass embl — Min. 4 1/2 in. thick lightweight or normal weight (100- 150 pcf) concrete with a max. 15 in. dia. opening. �2Steel Pipe or Conduit — Nom. d in. dia. (or smaller) Schedule 10S (or heavier) steel INSULATEDPIPE HANGER 4 pipe or rigid galvanized Steel conduit centered in the opening. A max. of one pipe FAN COIL UNIT No Scale or conduit is permitted in the fire --stop system. No Scale Pie Covering Material — Optional — The following types of pipe covering may be used: A. Nominal 2 in. thick hollow cylindrical heavy density (min. 3.5 pcf) glass fiber units jacketed on the outside with a PVC facing. Longitude joints sealed with metal fasteners or factory applied SSL. Transverse joints sealed with metal fasteners or with butt strip tape supplied with the product. B. Nominal 1 in, thick hollow cylindrical heavy density (min. 6 pcf) hydrous calcium AUTOMATIC FLOW CONTROL PRESSURE GAUGE Ec COCK (TYP.) silicate units covered with a PVC facing pipe insulation secured together with DEVICE PRESET BY MANUF. steel —tie wire. W/ P do T TEST PORTS, See Pipe and Equipment Covering Materials — (BRGU) category in Building Materials Directory for names of manufacturers. Any pipe covering meeting the above STRAINER, AND DRAIN. THREE WAY specifications and bearing the UL Classification Marking. (PRE -MANUF. SINGLE CONTROL VALVE Fire—Stop S tem — The hourly T— rating of the fire —stop system is dependent upon ASSEMBLY ACCEPTABLE) MANUAL AIR VENT W /AUTO the size of the pipe or conduit, the type of pipe covering (Item 3) the presence or SHUT -OFF COCK absence of pipe covering, and annular space between the periphery of the opening COIL and pipe covering and annular space within the opening. (PRE- MANUF. SINGLE Max. pipe or Typ. of Thickness of Annular T ASSEMBLY ACCEPTABLE) Conduit Dia. Pipe Covering Pipe Covering Space Rating E" CS 1" 11/2" 11/2 h a" FG 2" 1/2" 1 h E" — - 21/2" 0 h RETURN FILTER (a) CS = Calcium silicate Ir \ FG = Fiberglass RETURN AIR C o Insulation — ceramic fiber blanket nom. 1 in. thick, min. 1 pcf density wrapped around © the circumference of the pipe or conduit and secured together by means of fiber— I i lass tape. Blanket position such that it extends a min. of 2 in. beyond both sur- 9 SUPPLY PLUG � faces of the floor or wall assembly. COCK 000 4@ Fill, Void, or Cavity Material — Blanket* — Blanket wrapped around the circumference DPS -1 TS-2 of the pipe and insulation with vertical seams overlapping 1 in. Position blanket within the opening such that it extends a min. of 4 in. beyond both surfaces and secured SHUT-OFF VALVE (TYP.) DI together with metal staples and plastic cable ties. AI @ Fill, Void, or Cavity Material — Mastic* — Material that is troweled or applied with a / P T TEST PORTS caulking gun to fill the annular space between the blanket and the periphery of the U opening. Min. thickness shall be 4 -1/2 in. h I AIR FLOW A0 STRAINER W / SLOWDOWN UNION (TYP.) Al THERMOMETER W /SEPARABLE WELL (TYP.) FLEX. CONNECTION (TYP.) CHWR CHWS STS -1 NOTES: 1. PROVIDE (4 x DIA.) OF STRAIGHT PIPE ON BOTH SIDES OF BALANCING VALVE 2. ALL COMPONENTS FULL LINE SIZE UNLESS NOTED OTHERWISE 3. LOCATE UNIONS TO ALLOW FOR COIL PULL FIRE RATED FLOOR /WALL PIPE PENETRATION 3 -WAY COIL PIPING DIAGRAM 2 FAN COIL UNIT 5 3 No Scale W/INSULATION No Scale ••(f• i•• o • ••••• ••• ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com E #0000015 © Copyright 2009 TLC Engineering for Architecture, Inc. • Issue Date: Y Y ,ti • • C: ESC Scale: NTS Drawing Title: E N a)N T f • U • C_ c ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com E #0000015 © Copyright 2009 TLC Engineering for Architecture, Inc. Revisions: No. Date Description Seal Don C. Bailey, P.E. Florida License j35067 i9alY;j,atlM'!Frrr... 1 t Project No.: 109355 Issue Date: 10/05/2009'\__, ,ti Drawn By: U O C: ESC Scale: NTS Drawing Title: E N a)N T AND SCHEDULES U co cn co C_ c Q c n i O O ILO CO V) -P CL CID m Revisions: No. Date Description Seal Don C. Bailey, P.E. Florida License j35067 i9alY;j,atlM'!Frrr... 1 t Project No.: 109355 Issue Date: 10/05/2009'\__, ,ti Drawn By: ESC Approved By: ESC Scale: NTS Drawing Title: HVAC DETAILS AND SCHEDULES THIS DRAWING IS BEING RELEASED FOR THE PURPOSE OF 100% CONSTRUCTION DOCUMENTS Drawing No.: M301