09-979-0240 CV C) m 0 0 c� Ln 0 7� ci CO v w a_ z I 0 U Cll E (D U O Q C�J (Y Cr) Q Q 0 T E C 0 LO 0 I 0 0 THIS DRAWING IS BEING RELEASED FOR THE PURPOSE OF 100016 CONSTRUCTION DOCUMENTS • ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com EB #0000015 O Copyright 2009 TLC Engineering for Architecture, Inc. 109355 Issue Date: .a 10/051200, Drawn By: (1) 0 FIRE PROTECTION DETAILS DCB Scale: FIRE PROTECTION SPECIFICATION co FIRE PROTECTION LEGEND a) T M GENERAL NOTES • U cc v) m CID SYMBOL DESCRIPTION O r` LL =3 O C\1 0 1.00 - GENERAL PROVISIONS U) Q 1. FIRE PROTECTION SYSTEM TO COMPLY WITH NFPA 13 AND ALL APPLICABLE STATE CODES. CU m ae OR ma - CONTROL VALVE W /TAMPER SWITCH 2. � FINAL INSPECTION AND APPROVAL BY LOCAL FIRE MARSHAL AND ARCHITECT /ENGINEER. .••• 1.1 PROVIDE ALL LABOR, MATERIAL AND EQUIPMENT FOR A COMPLETE AND PROPERLY OPERATING FIRE PROTECTION SYSTEM. N - «p - CHECK VALVE FLOW SWITCH 3. r • • • SPRINKLER SHOP DRAWINGS AND MATERIAL SUBMITTALS SHALL BE SUBMITTED TO THE :•.•' ARCHITECT /ENGINEER AND STATE FIRE MARSHAL AND SHALL BE APPROVED PRIOR TO ANY 1.2 CODES AND STANDARDS: THE FIRE SPRINKLER PROTECTION SYSTEMS INSTALLATION, V FDC - FIRE DEPARTMENT CONNECTION INSTALLATION. FLUSHING AND TESTING SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13 AND ALL LOCAL 4a PIV - POST INDICATOR VALVE W/TAMPER SWITCH CODES HAVING JURISDICTION, 4. PIPE ROUTING SHOWN IS SCHEMATIC ONLY. IT IS THE RESPONSIOILITY OF THIS CONTRACTOR -`FVC - FIRE VALVE CABINET TO PROVIDE ANY ADDITIONAL OFFSETS REQUIRED FOR PROPER INSTALLATION AND 1.3 PIPE THREAD PATTERN: ALL THREADS SHALL BE IN ACCORDANCE WITH LOCAL FIRE COORDINATION WITH OTHER TRADES. DEPARTMENT SPECIFICATIONS AND NFPA 1963, 1991 REVISION. OW FFD�V� - STANDPIPE WITH FIRE DEPARTMENT VALVE - Dk� -P-E - SPRINKLER AND DRAIN RISER 5. PIPING IN AREAS WITH EXPOSED STRUCTURE SHALL BE INSTALLED AS HIGH AS POSSIBLE TO 1.4 UL /FM APPROVAL: ALL EQUIPMENT, VALVES, COUPLINGS, HANGERS AND DEVICES SHALL ALLOW THE OWNER MAXIMUM USE OF THE SPACE. TOP BEAM CLAMP BE APPROVED BY UNDERWRITERS' LABORATORY (UL) OR FACTORY MUTUAL (FM) FOR -CD- - BACKFLOW PREVENTOR W /TAMPER SWITCHES U.L. LISTED OR F.M. APPROVED ( )'� USE IN FIRE PROTECTION SERVICE. - ROOF MANIFOLD 6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR CEILING DESCRIPTIONS AND HEIGHTS. 1.5 LICENSURE: THE FIRE PROTECTION SYSTEMS SHALL BE INSTALLED BY A STATE OF O - HYDRAULIC REFERENCE NODE FLORIDA CERTIFIED FIRE PROTECTION CONTRACTOR. 7. SPRINKLERS ARE TO BE COORDINATED WITH ALL DIFFUSERS, SPEAKERS, LIGHTING FIXTURES - NEW SPRINKLER PIPING AND CEILING SYSTEMS, SPACING OF SPRINKLERS SHALL BE IN ACCORDANCE WITH NFPA 13 1.6 ALL FIRE PROTECTION WORK SHALL BE DONE IN A NEAT AND WORKMAN -LIKE MANNER. F.C. I'-- - FLUSHING CONNECTION AND THE LISTING OF THE SPRINKLER. ALL THREAD ROD 1.7 CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND FEES, ETC., REQUIRED �-` - EXISTING 1/2" UPRIGHT SPRINKLER 1. SPRINKLER LOCATIONS SHALL BE CENTERED IN THE TILE. PROVIDE ARMOVER OR SWING JOINT FOR THE EXECUTION OF THIS WORK. - EXISTING 1/2" RECESSED SPRINKLER AS REQUIRED. 1,1 CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADES BEFORE �� - EXISTING 1/2" CONCEALED SPRINKLER 9. SPRINKLERS IN AREAS WITH EXPOSED STRUCTURE (OBSTRUCTED CONSTRUCTION) SHALL BE FABRICATION OR INSTALLATION. OFFSETS AND /OR TRANSITIONS REQUIRED SHALL BE INSTALLED WITH DEFLECTOR 1" BELOW THE BOTTOM OF THE BEAM (MAXIMUM 22" BELOW PROVIDED WITHOUT ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND INSTALL z� - EXISTING CONTROL VALVE W /TAMPER SWITCH ROOF DECK). EXPOSED BAR JOISTS THAT HAVE SPRAY -ON FIRE PROOFING THAT MAKES THE WORK IN A TIMELY MANNER TO PREVENT DELAYS IN THE CONSTRUCTION. - EXISTING CHECK VALVE JOIST SOLID SHALL BE TREATED LIKE A BEAM WITH THE SPRINKLERS 1" BELOW THE BOTTOM PIPE HANGER RING 1.9 CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR OR REPLACE DAMAGED EQUIPMENT -0 - EXISTING FLOW SWITCH OF THE FIRE PROOFING. (U.L. LISTED OR F.M. APPROVED) AND /OR MATERIAL. Sl FDC - EXISTING FIRE DEPARTMENT CONNECTION 10. SLEEVE AND /OR FIRESTOP ALL PENETRATIONS THROUGH RATED WALLS, CEILINGS, AND FLOORS 1.10 PIPING SHOP DRAWINGS: SUBMIT 1/1" SCALE PIPING SHOP DRAWINGS, SHOP DRAWINGS - - - - EXISTING SPRINKLER PIPING WITH U/L LISTED ASSEMBLIES. FIRESTOP ASSEMBLIES SHALL BE EQUAL OR EXCEED THE RATING OF THE WALL, CEILING OR FLOOR. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. SHALL INCLUDE SPRINKLER PIPING CUT LENGTHS, OFFSETS, FITTINGS AND DEVICES, -EXISTING SPRINKLER PIPING TO BE REMOVED ELEVATIONS, HANGER LOCATIONS, SPRINKLER HEAD COUNT BY TYPE, ELEVATION 11. PROVIDE ACCESS PANELS TO ALL VALVES ABOVE NON - ACCESSIBLE CEILINGS AND CHASES. SECTIONS AND OTHER INSTALLATION INFORMATION. SUBMIT HYDRAULIC CALCULATIONS CONNECT TO EXISTING PROVING THE VIAOILITY OF THE MOST HYDRAULICALLY REMOTE AREAS OF THE PROJECT, - DEMOLISH TO POINT INDICATED 12. PROVIDE A PERMANENTLY ATTACHED NAME TAG TO THE RISER STATING THE REQUIRED DESIGN INDICATE HYDRAULIC REFERENCE POINTS AND SUBMIT COMPUTER ANALYZED NODAL CRITERIA FOR EACH HYDRAULICALLY - DESIGNED SYSTEM. CALCULATIONS IN BOTH TABULAR AND GRAPHICAL FORMATS. HYDRAULIC IMBALANCE - REVISION REFERENCE SHALL NOT EXCEED 0.01 GPM AT ANY NODE, AND WATER VELOCITY SHALL NOT EXCEED 20 FEET PER SECOND. DEMONSTRATE COMPLIANCE WITH THE REQUIREMENTS OF NFPA - DETAIL REFERENCE: TOP - DETAIL #, 13. PROVIDE SPRINKLERS UNDERNEATH ALL EXPOSED DUCTWORK WHICH IS OVER 41" WIDE AND 13 REGARDING DENSITY, AREA OF APPLICATION, SELECTION OF HYDRAULICALLY- REMOTE BOTTOM - DRAWING# SHOWN ON SPACE HEADS AROUND ALL OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13. HEADS UNDER AREAS, AND MAXIMUM COVERAGE PER SPRINKLER. DUCTS ARE NOT INDICATED ON THE DRAWINGS BUT ARE REQUIRED AND SHALL BE PROVIDED IN ACCORDANCE WITH NFPA 13. SPRINKLER LOCATIONS UNDER DUCTWORK AND AROUND NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT 1.11 COORDINATE ALL PIPE ROUTING WITH ALL OTHER TRADES PRIOR TO INSTALLATION, OBSTRUCTIONS SHALL BE GOVERNED BY FINAL INSTALLED LOCATIONS. ROUTE ALL PIPING TO AVOID DUCTWORK, PIPING, AND BUILDING STRUCTURE. 14. PROVIDE SPRINKLERS AT THE TOP AND BOTTOM OF ALL STAIRWELLS AND AT THE LANDING OF - FIRE SPRINKLER LEGEND EACH FLOOR THAT OPENS INTO MORE THAN ONE FIRE ZONE. 2.00 - BASIC MATERIALS AND METHODS 15. PROVIDE SPRINKLER GUARDS ON ALL HEADS IN ELECTRIC ROOMS, TELEPHONE ROOMS, SYMBOL ORF TEMP RESPONSE K -FAC FINISH MODEL STYLE PLATE MFG. ELEVATOR ROOMS, ELEVATOR SHAFTS AND ON ANY HEADS LESS THAN 7' -0" ABOVE THE 2,1 GENERAL: ONLY THE FOLLOWING MATERIALS DESIGNED FOR 175 PSIG CWP SHALL BE FLOOR. + /2 155' QUICK 5.62 CHROME F1 FR RECESSED CHROME RELIABLE I E USED FOR FIRE PROTECTION PIPING UNLESS SPECIFICALLY INDICATED OTHERWISE. ALL 16. IF SYSTEM PRESSURE EXCEEDS 100 PSI, ALL HANGERS ON END HEADS IN PENDANT POSITION 0 1/2" 155' QUICK 5.62 BRASS F1 FR UPRIGHT HD /GD RELIABLE PIPING MATERIALS SHALL HAVE CORROSION RESISTANCE RATING (CCO 1.0 OR SHALL WITH NFPA 13. 2.2 GREATER. PIPE: 2 INCH OR SMALLER PIPE, AND ALL THREADED PIPING SHALL BE BLACK STEEL, 17. BE WITHIN 12" OF END OF LINE IN ACCORDANCE COORDINATE PIPING WITH ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMERS, ETC.) PRIOR TO ANY INSTALLATION. DO NOT ROUTE ANY PIPING OVER ANY ELECTRICAL PANELS UNDER ANY HANGER "" STEEL 1 SCHEDULE 40, ASTM A-53. 2 -1/2 INCH AND LARGER PIPE MAY BE BLACK STEEL, SCHEDULE No Scale 10, ASTM A 135. CIRCUMSTANCES. ANY PIPING RUN OVER ELECTRICAL SHALL BE REROUTED AT NO ADDITIONAL 2.3 FITTINGS: SCHEDULE 40 BLACK STEEL PIPE SHALL BE JOINED BY MECHANICAL COST. COUPLINGS, THREADED OR WELDED FITTINGS; SCHEDULE 10 BLACK STEEL PIPE SHALL 11. PROVIDE 20 -GAUGE STEEL SPRINKLER CANOPY SHIELD AT SPRINKLERS IN TRASH CHUTE PER BE JOINED BY ROLLED GROOVE COUPLINGS OR WELDED FITTINGS ONLY. WELDED NFPA 13, BRANCH CONNECTIONS WHICH ARE AT LEAST 2 NOMINAL PIPE SIZES SMALLER THAN THE MAINS ARE PERMITTED. THREADED FITTINGS ARE ACCEPTABLE ONLY FOR PIPING 2 INCHES 19. SPRINKLERS IN ELEVATOR SHAFTS AND EQUIPMENT ROOMS ARE TO BE INTERMEDIATE AND SMALLER. TEMPERATURE 2 SPRINKLERS PER NFPA 13. 2.4 HANGERS: ALL HANGER SPACING SHALL COMPLY WITH THE REQUIREMENTS OF NFPA 13. 20. WET BULK SUPPLY MAINS AND HOSE SUPPLY MAINS EXPOSED TO THE WEATHER SHALL BE INSULATED AND PROVIDED WITH AN ALUMINUM JACKET. 2.5 SPRINKLER HEAD LOCATION: INSTALL SPRINKLER HEADS IN THE CENTER OF THE CEILING TILES FOR SUSPENDED CEILING APPLICATIONS. 2.6 SPRINKLER CAGE GUARD: PROVIDE HEAD GUARDS ON ALL HEADS IN ELECTRICAL ROOMS AND ON ALL HEADS LESS THAN 7' -0" ABOVE FINISHED FLOOR. 2.7 GAUGES: PROVIDE GAUGES AND GAUGE VALVES AS REQUIRED BY NFPA 13. GAUGE FIRE PROTECTION DRAWING INDEX SCALE SHALL BE 0 -300 PSI UNLESS OTHERWISE INDICATED. SHEET DESCRIPTION ISSUED 2.1 ACCESS PANELS: PROVIDE ACCESS PANELS TO ALL VALVES WITHIN CHASES OR ABOVE NON- ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES. 2.9 HYDROSTATIC TESTS: ABOVE GROUND AND BELOW GROUND PIPING SYSTEMS SHALL BE FP -1 FIRE PROTECTION LEGEND YES HYDROSTATICALLY TESTED AT NOT LESS THAN 200 PSI PRESSURE, OR AT 50 PSI IN FP -2 FLOOR PLAN - FIRE PROTECTION YES EXCESS OF THE MAXIMUM PRESSURE, WHICHEVER IS GREATER, FOR A PERIOD OF 2 HOURS, THE TEST PRESSURE SHALL BE READ FROM A GAUGE LOCATED AT THE LOW ELEVATION POINT OF THE INDIVIDUAL SYSTEM OR PORTION OF THE SYSTEM BEING TESTED. THE SPRINKLER PIPING SHALL NOT HAVE LEAKAGE EXCEEDING THE AMOUNTS SPECIFIED IN NFPA 24. LEAKAGE QUANTITIES SHALL BE DETERMINED BY PUMPING AT THE SPECIFIED TEST PRESSURE FROM A CALIBRATED CONTAINER. REPAIR LEAKING JOINTS AND RETEST AS NECESSARY UNTIL ALL SYSTEMS HAVE BEEN TESTED. TEST THE PIPING BETWEEN THE CHECK VALVE IN THE FIRE DEPARTMENT INLET PIPE AND THE OUTSIDE CONNECTION THE SAME AS THE BALANCE OF THE SYSTEM. 3.00 - FIRE PROTECTION VALVES AND ACCESSORIES 3.1 QUICK - RESPONSE UPRIGHT SPRINKLERS: SPRINKLER HEADS SHALL BE MANUFACTURED WITH UPRIGHT DEFLECTORS FOR INSTALLATION ABOVE THE BRANCH LINE WITH BRASS FINISH. 12 SPRINKLER CAGE GUARD: PROVIDE SPRINKLER HEAD OPEN -WIRE CAGE GUARD TO PROTECT HEADS FROM INJURY. CAGE WIRE SHALL BE CADMIUM - PLATED STEEL. THIS DRAWING IS BEING RELEASED FOR THE PURPOSE OF 100016 CONSTRUCTION DOCUMENTS • ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com EB #0000015 O Copyright 2009 TLC Engineering for Architecture, Inc. Revisions: No. Date Description Seal Don C. Bailey, P.E. Florida License #35067 ,(N 4 f f% 9 Project No.: 109355 Issue Date: .a 10/051200, Drawn By: (1) 0 }' DCB Scale: Q� co "E a) T M Co U cc v) m CID -C a) O r` LL =3 O C\1 0 Co U) Q CU m Revisions: No. Date Description Seal Don C. Bailey, P.E. Florida License #35067 ,(N 4 f f% 9 Project No.: 109355 Issue Date: 10/051200, Drawn By: JJB Approved By: DCB Scale: NTS Drawing Title: FIRE PROTECTION DETAILS AND SPECIFICATION Drawing No.: FP-1.