09-979-023
10 0 4" o 9/32" 0 —o (TYR.) LO-1 GND. CONDUCTOR TO MAIN SWITCHBOARD #310 GND. BAR (VIA BURNDY #YGB IRREVERSABLE CONNECTOR) f 1 3 TR.} GROUNDING ELECTRODE - PROVIDE ENGRAVED PHENOLIC NAMEPLATE AT GROUND DO NOT DISCONNECT THIS EACH BAR LOCATION WITH 12" r CADWELD 8544AO18 2 �-{ 1 -1 /8" I OR EQUAL I 1 O 0 0 0 0 0 GROUND LUGS 0 0 �o 0 0 MEN #3/0 GROUNDING CONDUCTOR TO LOCAL- METAL WATER PIPE. FRONT VIEW �v II 0 GROUND BUS BAR �0 0 0 0 0 CADWELD B544AO18 OR EQUAL OINSULATOR O x O I #3/0 GROUND LOOP TO OTHER GROUND BARS (VIA BURNDY #YGB IRREVERSABLE CONNECTOR) L GROUND CONDUCTORS (LE. TRANSFORMER, ETC.) QUANTITY AS REQUIRED, LABEL EACH CONDUIT /GROUND CONDUCTOR WITH ENGRAVED PHENOLIC NAMEPLATE WITH GROUND SERIVED, I.E. WATER PIPE, XFMR 'T LS3A ", ETC, TYPICAL FOR ALL GROUND CONDUCTORS. STANDOFF BRACKET �U II ELECTRICAL AND COMM. ROOM GROUND BAR No sraie _V) L L_ 4 (/7 lv P n N 6) 0 0 N 0 0 00 w U) a a� Cn a_ w I c a� U Cr cn Q I a 0 0 U) I L Ln 0 0 I 0 N 5 1/16" THICK WHITE PLASTIC WITH COLORED FACE PER 5PECIFCIATIONS 1/2" HIGH LETTERING FOR - PANELBOARD NAME A H U — X 1/4" HIGH LETTERING FOR REMAINING TEXT 480V, 30 FED FROM "NDH1 -4" ADHESIVE BACKING WHEN INSTALLED IN CONDITIONED SPACES AHU -X & 480V 30"7 FED FROM "NDH1 -4" TYPICAL EQUIPMENT EQUIPMENT NAMEPLATE No Scale EQUIPMENT VOLTAGE -EQUIPMENT NAME FASTEN WITH BRASS SCREWS WHEN LOCATED IN NON- CONDITIONED OR EXTERIOR SPACES EQUIPMENT SOURCE (PANEL do CIRCUIT) 0 WALL ASSEMBLY - THE 1, 2, 3, OR 4 HOUR FIRE -RATED GYPSUM WALLBOARD /STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY. CONDUIT - NOM 4" DIA OR SMALLER STEEL ELECTRICAL METALLIC TUBING, A MAX OF ONE CONDUIT IS PERMITTED IN THE FIRESTOP SYSTEM. CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. O FILL VOID OR CAVITY MATERIAL - CAULK FILL MATERIAL BEARING THE UL CLASSIFICATION MARKING INSTALLED TO COMPLETELY FILL ANNULAR SPACE BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD AND WITH A MIN 1/4" DIAM BEAD OF CAULK APPLIED TO PERIMETER OF CONDUIT AT ITS EGRESS FROM THE WALL. CAULK INSTALLED SYMMETRICALLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED BELOW: MAX CONDUIT ANNULAR SPACE, F RATING, HR. T RATING, HR. DIAM, IN. IN. 1 0 TO 3/16 1 OR 2 0, 1 OR 2 1 1/4 TO 1/2 3OR4 3OR4 4 0 TO 1 -1/2 1 OR 2 0 6 1/4 TO 1/2 3 OR 4 0 12 3/16 TO 3/8 1 OR 2 0 PAA111111T DCAICT�ATIALI r1c elnru��� � •1f• ••i • r e so* •• • si • • • • �I ••1• ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com EB #0000015 © Copyright 2009 TLC Engineering for Architecture, Inc. ENET rim i wri OF FIREWALL 2 UL SYSTEM NO. W -L -1001 THIS DRAWING IS BEING RELEASED FOR THE PURPOSE OF 100% CONSTRUCTION DOCUMENTS Seal James Ferris, P.E. Florida License #65156 �yS !v i Project No.: 109355 Issue Date: 10/05/2009 Drawn By: LAR Approved By: JDF Scale: NTS Drawing Title: ELECTRICAL DETAILS Drawing No.: E803. ■ ■ (a 1L © }" 2 N co ' E T E Cn M U U) M CL i n LL OC) U) (.0 T W Q c m 1 Revisions: No. Date Description ENET rim i wri OF FIREWALL 2 UL SYSTEM NO. W -L -1001 THIS DRAWING IS BEING RELEASED FOR THE PURPOSE OF 100% CONSTRUCTION DOCUMENTS Seal James Ferris, P.E. Florida License #65156 �yS !v i Project No.: 109355 Issue Date: 10/05/2009 Drawn By: LAR Approved By: JDF Scale: NTS Drawing Title: ELECTRICAL DETAILS Drawing No.: E803. ■ ■