Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
09-979-012
0 • • • • • • " . • • • • r . • r • ♦ (. • r• •• • • r ♦r• r • • u u u • • • • V • • • ••••• • • c WITH APPROPRIATE FLANGE. LOWEST MEDIUM MEDIUM HIGH HIGHEST © POKE THRU CONFERENCE ROOMS a> ui 0 00 Ln N N rn 0 0 N c Q, 0 0 0 LLJ W v -n n w i 0 d U 0 E a� U U Q_ (D I o- U) 0 z E 0 cn I U Ln 0 _n I 0 0 / ELECTRICAL SYMBOL LEGEND GFI RECEPTACLE MOUNTED ABOVE COUNTER TWO DUPLEX RECEPTACLES WITH COMMON COVER TWO DUPLEX RECEPTACLES WITH COMMON COVER MOUNTED ABOVE COUNTER DUPLEX RECEPTACLE NOTE: TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT (RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND GN GROUND BAR JUNCTION BOX -� JUNCTION BOX- WALL MOUNTED (,�.... JUNCTION BOX- FURNITURE SYSTEM FEED SPEAKER - CEILING MOUNTED ■ CONDUIT SEAL -OFF FITTINGS C3 SURGE SUPPRESSOR C3 = SERVICE ENTRANCE DEVICE B3 = DISTRIBUTION BOARD DEVICE A3 = PANELBOARD DEVICE ST SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS MAGNETIC MOTOR STARTER OR CONTACTOR SIZE AS NOTED EDH-X ELECTRIC DUCT HEATER MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER VARIABLE FREQUENCY DRIVE DD DIRECT DIGITAL CONTROL PANEL El TRANSFORMER ® AUTOMATIC TRANSFER SWITCH LE 30AR NON -FUSED DISCONNECT SWITCH, SIZE do # OF POLES NF NF DENOTES NON -FUSED AR DENOTES AMP RATING OF SWITCH LE -30AR 20AF FUSED DISCONNECT AR DENOTES AMP RATING OF SWITCH MCP AF DENOTES AMP FUSE SIZE SIZE '_ # OF POLES L� i 3 -- COMBINATION MAGNETIC MOTOR STARTER, SIZE & OF POLES 3 POLE UNLESS OTHERWISE NOTED ENCLOSURE NEMA RATING. NEMA STARTER SIZE BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, SURFACE MOUNTED _�._.... BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, FLUSH MOUNTED „ MMA BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, SURFACE MOUNTED BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, FLUSH MOUNTED BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). CIF-- GROUND OR GROUND ROD AS NOTED EMERGENCY BRANCH CONDUIT ] CONDUIT STUB CONDUIT CONTINUED - - EXISTING TO BE REMOVED EXISTING TO REMAIN ik EXISTING AFFECTED BY THIS PROJECT - - -- FUTURE NEW IC INTERCOM STATION KP KEY PAD �N NURSE STATION TOILET EMERGENCY STATION FIRE ALARM /DETECTION SYSTEM SYMBOL DESCRIPTION F❑ MANUAL PULL STATION Eg CEILING SMOKE DETECTOR, PHOTO- ELECTRIC TYPE UNLESS OTHERWISE NOTED E = ELEVATOR WITH RECALL CONTACTS I = IONIZATION ] SUPERVISED CONTROL RELAY 04 COMBINATION AUDIBLE /VISUAL XXCD NOTIFICATION DEVICE CD = CANDELA RATING VISUAL SIGNALING UNIT, WALL MOUNTED (NO AUDIO DEVICE) Fo FIRE ALARM CONTROL PANEL Fo FIRE ALARM TERMINAL CABINET FAAP FIRE ALARM ANNUNCIATOR PLAN - FLUSH MOUNTED '�F ----` FIRE ALARM SYSTEM CONDUIT AND WIRING LIGHTING F-O-� FLUORESCENT STRIP FIXTURE 4 FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX DIVISION 16 SPECIFICATIONS INFECTION CONTROL RISK ASSESSMENT (ICRA) BASIC MATERIALS SYMBOL DESCRIPTION E001 ICRA MATRIX 7 Sa SINGLE POLE SWITCH LEVEL- TYPE: A TYPE B TYPE C TYPE D (SUBSCRIPT INDICATES ITEM CONTROLLED) _ ......._� _ ............ ._... S3 THREE -WAY SWITCH GROUP 3 S4 FOUR -WAY SWITCH CLASS III SD DIMMER SWITCH CLASS IV (1500 WATTS UNLESS OTHERWISE INDICATED) CLASS III DUPLEX RECEPTACLE CLASS III /IV ® FLOOR OUTLET BOX AND DUPLEX RECEPTACLE INFECTION CONTROL RISK LEVELS WITH APPROPRIATE FLANGE. LOWEST MEDIUM MEDIUM HIGH HIGHEST © POKE THRU CONFERENCE ROOMS POWER POLE RADIOLOGY AREAS DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER PUBLIC BATHROOMS DUPLEX SAFETY RECEPTACLE MOUNT ROCP COVERPLATES WITH SPANNER HEAD SCREWS WAITING ROOMS* GFI RECEPTACLE. WP DENOTES WEATHERPROOF COVER. LABOR AND DELIVERY WP a> ui 0 00 Ln N N rn 0 0 N c Q, 0 0 0 LLJ W v -n n w i 0 d U 0 E a� U U Q_ (D I o- U) 0 z E 0 cn I U Ln 0 _n I 0 0 / ELECTRICAL SYMBOL LEGEND GFI RECEPTACLE MOUNTED ABOVE COUNTER TWO DUPLEX RECEPTACLES WITH COMMON COVER TWO DUPLEX RECEPTACLES WITH COMMON COVER MOUNTED ABOVE COUNTER DUPLEX RECEPTACLE NOTE: TICK MARKS SHOWN ON ANY DEVICE REPRESENTS RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT (RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND GN GROUND BAR JUNCTION BOX -� JUNCTION BOX- WALL MOUNTED (,�.... JUNCTION BOX- FURNITURE SYSTEM FEED SPEAKER - CEILING MOUNTED ■ CONDUIT SEAL -OFF FITTINGS C3 SURGE SUPPRESSOR C3 = SERVICE ENTRANCE DEVICE B3 = DISTRIBUTION BOARD DEVICE A3 = PANELBOARD DEVICE ST SHUNT -TRIP BUTTON - FLUSH MOUNTED UNLESS OTHERWISE NOTED NEMA 3R FOR EXTERIOR LOCATIONS MAGNETIC MOTOR STARTER OR CONTACTOR SIZE AS NOTED EDH-X ELECTRIC DUCT HEATER MOTOR CONNECTION, NUMBER DENOTES HORSEPOWER VARIABLE FREQUENCY DRIVE DD DIRECT DIGITAL CONTROL PANEL El TRANSFORMER ® AUTOMATIC TRANSFER SWITCH LE 30AR NON -FUSED DISCONNECT SWITCH, SIZE do # OF POLES NF NF DENOTES NON -FUSED AR DENOTES AMP RATING OF SWITCH LE -30AR 20AF FUSED DISCONNECT AR DENOTES AMP RATING OF SWITCH MCP AF DENOTES AMP FUSE SIZE SIZE '_ # OF POLES L� i 3 -- COMBINATION MAGNETIC MOTOR STARTER, SIZE & OF POLES 3 POLE UNLESS OTHERWISE NOTED ENCLOSURE NEMA RATING. NEMA STARTER SIZE BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, SURFACE MOUNTED _�._.... BRANCH CIRCUIT PANELBOARD, UNDER 250 VOLTS, FLUSH MOUNTED „ MMA BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, SURFACE MOUNTED BRANCH CIRCUIT PANELBOARD, OVER 250 VOLTS, FLUSH MOUNTED BRANCH CIRCUIT CONDUIT CONCEALED ABOVE CEILING OR IN WALL. CONDUIT SHALL INCLUDE PHASE, NEUTRAL AND GROUND CONDUCTORS AS REQUIRED FOR CIRCUITS (UNLESS OTHERWISE NOTED). CIF-- GROUND OR GROUND ROD AS NOTED EMERGENCY BRANCH CONDUIT ] CONDUIT STUB CONDUIT CONTINUED - - EXISTING TO BE REMOVED EXISTING TO REMAIN ik EXISTING AFFECTED BY THIS PROJECT - - -- FUTURE NEW IC INTERCOM STATION KP KEY PAD �N NURSE STATION TOILET EMERGENCY STATION FIRE ALARM /DETECTION SYSTEM SYMBOL DESCRIPTION F❑ MANUAL PULL STATION Eg CEILING SMOKE DETECTOR, PHOTO- ELECTRIC TYPE UNLESS OTHERWISE NOTED E = ELEVATOR WITH RECALL CONTACTS I = IONIZATION ] SUPERVISED CONTROL RELAY 04 COMBINATION AUDIBLE /VISUAL XXCD NOTIFICATION DEVICE CD = CANDELA RATING VISUAL SIGNALING UNIT, WALL MOUNTED (NO AUDIO DEVICE) Fo FIRE ALARM CONTROL PANEL Fo FIRE ALARM TERMINAL CABINET FAAP FIRE ALARM ANNUNCIATOR PLAN - FLUSH MOUNTED '�F ----` FIRE ALARM SYSTEM CONDUIT AND WIRING LIGHTING F-O-� FLUORESCENT STRIP FIXTURE 4 FLUORESCENT WALL MOUNTED FIXTURE WITH WALL OUTLET BOX DIVISION 16 SPECIFICATIONS INFECTION CONTROL RISK ASSESSMENT (ICRA) ALL WORK SHALL CONFORM WITH THE OWNER'S INFECTION CONTROL AND CONSTRUCTION POLICIES, PROCESSES AND OWNER'S PROJECT - SPECIFIC INFECTION CONTROL RISK ASSESSMENT PLAN. E001 ICRA MATRIX 7 IC RTSK CONSTRUCTTON ACTTVTTY TYPE - LEVEL- TYPE: A TYPE B TYPE C TYPE D GROUP 1 CLASS I CLASS II i CLASS II CLASS III /IV _ ......._� _ ............ ._... GROUP 2 CLASS I CLASS II CLASS III CLASS IV GROUP 3 CLASS I CLASS III CLASS III /IV CLASS IV GROUP 4 CLASS III CLASS III /IV CLASS III /IV CLASS IV INFECTION CONTROL RISK LEVELS GROUP 1 GROUP 2 GROUP 3 GROUP 4 LOWEST MEDIUM MEDIUM HIGH HIGHEST OFFICE AREAS ALL PATIENT CARE UNITS EMERGENCY ROOM TRANSPLANT CLINIC - CONFERENCE ROOMS WAITING ROOMS* RADIOLOGY AREAS SURGERY SUITES PUBLIC BATHROOMS YES ROCP RECOVERY ROOMS WAITING ROOMS* E803 LABOR AND DELIVERY LABOR & DELIVERY ORs` Q NURSERIES CARDIAC CATH / ANGIO PEDIATRICS CVICU m RIO SURGERY OUTPATIENT UNITS ALL INTENSIVE CARE AREAS DIALYSIS AND TRANSPLANT NUCLEAR MEDICINE ONCOLOGY / BONE MARROW ADMISSION / DISCHARGE AREA CARDIOLOGY _._ ............ - PHYSICAL THERAPY TANK AREA HYPERBARIC MEDICINE - _.............. CAFETERIA ENDOSCOPYiI ECHOCARDIOGRAPHY PHARMACY ADMIXTURE: LABORATORIES PHARMACY I *(DEPENDENT ON LOCATION L.... -._ .... CONSTRUCTION ACTIVITY TYPES INSPECTIONS AND NON- INVASIVE ACTIVITIES. INCLUDES, BUT IS NOT LIMITED TO, REMOVAL OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO 1 TYPF A TILE PER 50 SQUARE FEET, PAINTING (BUT NOT SANDING) WALL COVERING, ELECTRICAL TRIM WORK, MINOR PLUMBING, AND ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE CUTTING OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL INSPECTION. TYPE B - . .. ........ ..... _ SMALL SCALE, SHORT DURATION ACTIVITIES WHICH CREATE MINIMAL DUST. INCLUDES, BUT IS NOT LIMITED TO, INSTALLATION OF TELEPHONE AND OF WALLS OR CEILING WHERE DUST MIGRATION CAN BE CONTROLLED. COMPUTER CABLING, ACCESS TO CHASE SPACES, CUTTING ANY WORK WHICH GENERATES A MODERATE TO HIGH LEVEL OF DUST OR REQUIRES DEMOLITION OR REMOVAL OF ANY FIXED BUILDING COMPONENTS OR ASSEMILIES. INCLUDES, BUT IS NOT LIMITED TO, SANDING OF WALL FOR PAINTING OR WALL COVERING, REMOVAL OF FLOOR COVERINGS, CEILING TILES TYPE C AND CASEWORK, NEW WALL CONSTRUCTION, MINOR DUCTWORK OR ELECTRICAL WORK ABOVE CEILINGS, MAJOR CABLING ACTIVITIES, AND ANY ACTIVITY WHICH CANNOT BE COMPLETED WITHIN A SINGLE WORKSHIFT. MAJOR DEMOLITION AND CONSTRUCTION PROJECTS. INCLUDES, BUT IS NOT LIMITED TO, ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK SHIFTS, TYPE D I REQUIRE HEAVY DEMOLITION OR REMOVAL OF A COMPLETE CEILING SYSTEM, AND NEW CONSTRUCTION. ICRA CLASSIFICATION SCHEDULE 1, EXECUTE WORK BY METHODS TO MINIMIZE RAISING DUST FROM CONSTRUCTION OPERATIONS. CLASS I 2. IMMEDIATELY REPLACE ANY CEILING TILE DISPLACED FOR VISUAL INSPECTION. 3. MINOR DEMOLITION FOR REMODELING. 1. PROVIDES ACTIVE MEANS TO PREVENT AIRBORNE DUST FROM DISPERSING INTO ATMOSPHERE. 2, WATER MIST WORK SURFACES TO CONTROL DUST WHILE CUTTING. 3, SEAL UNUSED DOORS WITH DUCT TAPE. CLASS II 4. BLOCK OFF AND SEAL AIR VENTS. 5. WIPE SURFACES WITH DISINFECTANT. El 6, CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS. 7. WET MOP AND /OR VACUUM WITH HEPA FILTERED VACUUM BEFORE LEAVING WORK AREA. 8, PLACE DUST MAT AT ENTRANCE AND EXIT OF WORK AREA. 9, REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED. 1. OBTAIN INFECTION CONTROL PERMIT BEFORE CONSTRUCTION BEGINS. 2. ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF THE DUCT SYSTEM. 3. COMPLETE ALL CRITICAL BARRIERS OR IMPLEMENT CONTROL CUBE METHOD BEFORE CONSTRUCTION BEGINS. 4, MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS AND MONITOR WITH MAGNEHELIC GAUGES. 5, DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETE PROJECT IS THOROUGHLY CLEANED BY ENVIRONMENTAL SERVICES DEPARTMENT, CLASS III 6. VACUUM WORK WITH HEPA FILTERED VACUUMS. [� 7. WET MOP WITH DISINFECTANT. 8. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION. 9. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS. 10, COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING. 11. REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED. 1. OBTAIN INFECTION CONTROL PERMIT BEFORE CONSTRUCTION BEGINS. 2. ISOLATE HVAC SYSTEM IN AREA WHERE WORK IS BEING DONE TO PREVENT CONTAMINATION OF THE DUCT SYSTEM. 3. COMPLETE ALL CRITICAL BARRIERS OR IMPLEMENT CONTROL CUBE METHOD BEFORE CONSTRUCTION BEGINS. 4. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR FILTRATION UNITS AND MONITOR WITH MAGNEHELIC GAUGES. 5. SEAL HOLES, PIPES, CONDUITS, AND PUNCTURES APPROPRIATELY. 6. CONSTRUCT ANTEROOM AND REQUIRE ALL PERSONNEL TO PASS THROUGH THIS ROOM SO THEY CAN BE VACUUMED USING A HEPA VACUUM CLEANER BEFORE LEAVING WORK SITE OR THEY CAN WEAR CLOTH OR PAPER COVERALLS THAT ARE REMOVED EACH TIME THEY LEAVE THE WORK SITE. CLASS TV 7. ALL PERSONNEL ENTERING WORK SITE ARE REQUIRED TO WEAR SHOE COVERS. 8. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS THOROUGHLY CLEANED BY THE ENVIRONMENTAL SERVICES DEPARTMENT AND ❑ RELEASED BY SAFETY AND INFECTION CONTROL. 9. VACUUM WORK AREA WITH HEPA FILTERED VACUUMS. 10. WET MOP WITH DISINFECTANT. 11. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS ASSOCIATED WITH CONSTRUCTION. 12, CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS. 13, COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING. 14. REMOVE OR ISOLATE HVAC SYSTEM IN AREAS WHERE CONSTRUCTION IS BEING DONE. LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MANUFACTURER AND CATALOG NO. VOLTAGE LAMPS REMARKS 4', 2 LAMP FLUORESCENT STRIP FIXTURE, W /WIRE DAYBRITE T232 UNV 1 /2EB /CG 4 (2) F32T8 J2 GUARD- SURFACE OR PENDANT MOUNTED LITHONIA C 2 32 MVOLT GEB101S WGCUN 277 41 COX OR APPROVED EQUAL NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. • GENERAL NOTES: :. . 1. LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, . •. • UNLESS OTHERWISE NOTED. " "•" 2. RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE, W••." . UNLESS OTHERWISE NOTED, ABOVE COUNTER RECEPTACLES SHALL BE MOUNTED 6" ABOVE BACK SPLASH TO CENTERLINE OF DEVICE. 3, THE EQUIPMENT GROUNDING TERMINAL BARS OF THE NORMAL AND ESSENTIAL ELECTRICAL SYSTEM PANELBOARDS SERVING THE SAME PATIENT VICINITY SHALL BE BONDED TOGETHER WITH AN INSULATED, CONTINUOUS, COPPER CONDUCTOR NOT SMALLER THAN NUMBER 10. 4. EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH THEY ARE TO BE INSTALLED. A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110. B. THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING, DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES IN ACCORDANCE WITH NEC 408, 6. CRITICAL AND LIFE SAFETY LIGHT SWITCHES SHALL BE ROUTED IN CONDUIT AND BOXES OTHER THAN THAT FOR THE NORMAL BRANCH. ESSENTIAL SYSTEM SWITCHES SHALL BE RED IN COLOR. 7. PATIENT CARE AREAS SHALL BE PROVIDED WITH GROUNDING IN ACCORDANCE WITH NEC 517. 8. WHEN ELECTRICAL BOXES ARE LOCATED IN VERTICAL FIRE RESISTIVE ASSEMBLIES, (CLASSIFIED AS FIRE /SMOKE AND SMOKE PARTITIONS), THEY SHALL BE INSTALLED WITHOUT AFFECTING THE FIRE CLASSIFICATION. ALL OF THE FOLLOWING CONDITIONS SHALL BE MET: A. ALL ELECTRICAL BOXES SHALL BE METALLIC. B. BOX OPENING SHALL OCCUR ONLY ON ONE SIDE OF FRAMING SPACE. C. BOX OPENING SHALL NOT EXCEED 16 SQUARE INCHES. D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL). E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF THE WALL RATING SHALL BE MAINTAINED. F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100 SQUARE INCHES PER 100 SQUARE FEET. G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL BE SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES. H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS. 1, THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING. 9. NON- METALLIC RACEWAYS SHALL NOT BE USED TO SERVE ANY PATIENT CARE SPACE. ALL WIRING SHALL BE MECHANICALLY PROTECTED BY INSTALLATION IN METALLIC RACEWAYS. 10. ALL DEVICES SHALL BE MOUNTED VERTICAL, UNLESS OTHERWISE NOTED. 11. ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP. 12, THE NUMBER OF ARROWHEADS ON THE HOMERUNS DENOTES THE NUMBER OF CIRCUITS. 13, PANELBOARD BRANCH CIRCUIT "RECIRCUITING" REQUIREMENTS: ALL BRANCH CIRCUITS BEING USED FOR "RECIRCUITING" SHALL BE FULLY INVESTIGATED BY THE CONTRACTOR PRIOR TO PERFORMING THE REQUIRED WORK. "RECIRCUITING" SHALL INCLUDE, BUT NOT LIMITED TO DEMOLISHING EXISTING ELECTRICAL DEVICES SHOWN AS BEING REMOVED AND REUSING THAT BRANCH CIRCUIT TO FEED NEW ELECTRICAL DEVICES. INTENT OF "RECIRCUITING" IS TO INTERCEPT THE EXISTING BRANCH CIRCUITS AT THE NEAREST, MOST CONVENIENT OVERHEAD JUNCTION BOX FOR EXTENSION TO NEW ELECTRICAL' DEVICES SHOWN. THE REUSE OF EXISTING RACEWAYS SHALL BE PERMITTED TO THE FULLEST EXTENT POSSIBLE PROVIDED THAT THE RACEWAYS ARE METALLIC AND PROPERLY SUPPORTED PER THE NEC. CONTRACTOR SHALL ENSURE THAT SUCH RACEWAYS ARE SUPPORTED; AND IF REQUIRED, ADD ADDITIONAL SUPPORTS. WHERE THE REUSE OF EXISTING RACEWAYS OCCURS, CONTRACTOR SHALL ENSURE THAT PROPER SEPARATION OF WIRING CLASSIFICATIONS IS MAINTAINED THROUGHOUT THE ENTIRE CIRCUIT. WHERE CO- MINGLING OCCURS, CONTRACTOR SHALL REMOVE THE NECESSARY WIRING AND REINSTALL IN SEPARATE RACEWAYS TO MAINTAIN THE REQUIRED SEPARATION. ALL WIRING DEVICE'S COVERPLATES INCLUDING BUT NOT LIMITED TO RECEPTACLES AND SWITCHES SHALL BE REPLACED WITH NEW ENGRAVED COVERPLATES WITH THE BRANCH, CIRCUIT IDENTIFICATION AS REQUIRED(I.E. "PANELNAME "- "CIRCUIT NUMBER "). 14. ALL EXISTING AND NEW BRANCH CIRCUIT PANELS SHALL BE PROVIDED WITH NEW TYPED WRITTEN PANEL SCHEDULES THAT CLEARLY IDENTIFY THE LOCATION AND THE TYPE OF LOAD SERVED. NEW PANEL SCHEDULES SHALL REFLECT THE CURRENT AS -BUILT CONDITIONS IN THE AREAS, NOT THE CURRENT IDENTIFICATION FOUND ON THE EXISTING SCHEDULES. ALL BRANCH CIRCUITS COMPLETELY DEMOLISHED SHALL BE MARKED AS "SPARE ". 15. WHERE SPECIFICALLY REQUIRED BY THESE DOCUMENTS OR WHERE CONTRACTOR DEEMS NECESSARY, A COMPLETE CIRCUIT TRACE OF ALL BRANCH CIRCUITS WITHIN A SPECIFIC PANEL SHALL BE PERFORMED. CIRCUIT TRACE SHALL BE USED TO DEVELOP AN ACCURATE SCHEDULE OF A PANELS BRANCH CIRCUITS EXISTING AS -BUILT CONDITIONS. THE AS -BUILT SCHEDULES AND FLOOR PLANS SHALL BE FORWARDED TO THE ENGINEER FOR INCORPORATION INTO THE PROJECT DOCUMENTS AND ISSUANCE OF AN ADDENDUM TO PROVIDE CLEAR DIRECTION ON THE EXACT RECIRCUITING REQUIREMENTS FOR A SPECIFIC PANEL. 16. CONTRACTOR SHALL PERFORM A COMPLETE EQUIPOTENTIAL GROUND TEST IN ACCORDANCE WITH NFPA 99 UPON THE COMPLETION OF ALL EXISTING BRANCH CIRCUITS TO THE NEW PANELS SPECIFIED. GROUND TEST SHALL BE IN A TYPED WRITTEN FORMAT FOR ISSUANCE TO AHCA AT THE INDIVIDUAL 100% INSPECTIONS. TEST SHALL BE PERFORMED IN ALL AFFECTED PATIENT -CARE AREAS. 17, CONTRACTOR SHALL COORDINATE WITH THE HOSPITAL PRIOR TO COMMENCING WORK AND DURING CONSTRUCTION FOR POWER AND /OR SYSTEM OUTAGES AS WELL AS GENERAL REQUIREMENTS. SHEET ELECTRICAL DRAWING INDEX DESCRIPTION ISSUED E000 ELECTRICAL LEGEND AND NOTES YES E001 ELECTRICAL ONE -LINE DIAGRAM YES E002 ELECTRICAL ONE -LINE DIAGRAM YES E003 ELECTRICAL ONE -LINE DIAGRAM YES E201 ELECTRICAL DEMOLITION - POWER YES E301 PARTIAL FIRST FLOOR PLAN - POWER YES E302 EIGHTH FLOOR MECHANICAL PENTHOUSE YES E601 ENLARGED ELECTRICAL ROOMS - CEP YES E602 ENLARGED ELECTRICAL ROOMS - NORTH TOWER YES E801 PANEL SCHEDULES YES E802 PANEL SCHEDULES YES E803 ELECTRICAL DETAILS YES THIS DRAWING IS BEING RELEASED FOR THE PURPOSE OF 100% CONSTRUCTION DOCUMENTS ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600' Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com EB #0000015 © Copyright 2009 TLC Engineering for Architecture, Inc. Revisions: No. Date Description Seal James Ferris, P.E. Florida License #65156 ' s . v o Project No.: 109355 Issue Date: 10/05/2009 Drawn By: LAR Approved By: JDF scale: NTS Drawing Title: ELECTRICAL, AND NOTES Drawing No.: E000 O *� a) co co U ua m Cam_ G CU -2'2 CL a) ce) _O r LL O � Co Q m Revisions: No. Date Description Seal James Ferris, P.E. Florida License #65156 ' s . v o Project No.: 109355 Issue Date: 10/05/2009 Drawn By: LAR Approved By: JDF scale: NTS Drawing Title: ELECTRICAL, AND NOTES Drawing No.: E000