09-979-010
t 16" 16" 16" 16" MAXIMUM MAX. MAX. MAX. RUNNER AT IE- k MAX. --T BOTTOM OF TYPICAL DECK I N 1 METAL METAL STUD I B I A I A CENTERLINE OF STUDS I MIN ELEVATION 5/8" TYPE "X" AT FLOOR RUNNER C 3 5/8" GYPSUM BOARD I I ,•� ew "� - - (MINIMUM OF TWO ° (MINIMUM) M ETAL STUDS C PANHEAD SCREWS(4) z z Uj o W {B OPENING C WIDTH 3 5/8" (MINIMUM) U 1 CO . METAL RUNNER a SECTION A -A � RETAINING ANGLE 3 L.� O N �E N di— (TYPICAL) z o LU GYPSUM BOARD PATCH NOTES: 1. GYPSUM PANELS SHALL BE SCREWED TO ALL STUD AND RUNNER FLANGES AT 12" O.C. (MAXIMUM) SURROUNDING THE OPENING. 2. SEE MANUFACTURER'S FIRE DAMPER STANDARD INSTALLATION INSTRUCTIONS FOR ADDITIONAL DETAILS AND REQUIREMENTS. 3, CONTRACTOR SHALL PROVIDE A COPY OF THE MANUFACTURER'S DAMPER INSTALLATION INSTRUCTIONS DURING THE INSPECTIONS BY AUTHORITIES HAVING JURISDICTION. 3 5/8" (MINIMUM) 20 GAGE (MINIMUM) 90 DEGREE BEND RUNNER METAL METAL STUD JOINT AT SECOND LAYER WHERE RUNNER METAL CENTERLINE OF STUDS I MIN ELEVATION 5/8" TYPE "X" AT FLOOR RUNNER C GYPSUM BOARD I I ,•� ew '-' (MINIMUM OF TWO ° r- SCREWS 3 5/8" (MINIMUM) U 1 CO . METAL RUNNER a SECTION A -A � RETAINING ANGLE 3 L.� O N �E z (TYPICAL) z o LU GYPSUM BOARD PATCH o BREAKAWAY Z o TO FIT WITHIN TOLERANCE o CONNECTIONS 0 ALLOWED BY APPROVED PER DAMPER - TESTED "THROUGH - H A M MANUFACTURER M I T TWO -HOUR RATED '7�=DAMPER SLEEVE ONE -HOUR RATED 1 0 o o o - o - - - - - - z SECTION B - B EXPANSION CLEARANCE PER K Florida DAMPER MANUFACTURER (TYPICAL) 5/8" TYPE CERT, r. GYPSUM BOARD _j BREAKAWAY a U CONNECTIONS U 3 5/8' (MINIMUM) r PER DAMPER °- �v 20 GAGE MANUFACTURER 5 METAL STUDS - a z J RETAINING ANGLE z of RETAINING ANGLE w U`' Li (TYPICAL) - 7- �0 0 I TWO -HOUR RATED DAMPER ONE -HOUR RATED REVERSE ANGLE SECTION C- C SLEEVE MOUNTING (ONE SIDE) METAL STUD FRAMING AT FIRE DAMPERS & COMBINATION FIRE /SMOKE DAMPERS DETAIL IN RATED FIRE BARRIERS AND /OR NOT TO SCALE RATED SMOKE BARRIERS NOTES: 1. COMPLY WITH THE REQUIREMENTS OF THE "PENETRATION FIRESTOPPING SCHEDULE" IN PART 3 OF SPECIFICATION 07 8413 - PENETRATION FIRESTOPPING. COMPLY WITH NOTE 2. 2. PENETRATIONS SHALL COMPLY WITH FBC SECTION 712.4.1. 3. THE ENTIRE OUTSIDE DIAMETER OF THE PIPE SLEEVE MUST BE LOCATED SO AS TO NOT INTERFERE WITH ANY LAYERS OF GYPSUM BOARD IN ANY WALL. PIPE SLEEVES ARE ALLOWED TO BE VISIBLE ONLY IN NON - OCCUPIED SPACES SUCH AS MECHANICAL ROOMS WHICH DO NOT HAVE FINISH CEILINGS. APPROVED I HKUUUH —F'LNL I KAI IUN NON - COMBUSTIBLE PIPE, CONDUIT, ETC. _4 I I I FIRESTOP SYSTEM" (PER APPROPRIATE TESTED ASSEMBLY) SHALL MATCH DOTTED LINE INDICATES PIPING I I I I HOURLY RATING OF SLAB. COMPLY INSULATION (WHERE REQUIRED). I I i I WITH NOTE 1. SEAL TIGHT (TYPICAL INSULATION SHALL NOT ABOVE & BELOW PENETRATE THE SLAB. L SLAB) TO COMPLY a WITH FIRESTOP 1 1/2" MINIMUM) BARRIER SYSTEM SEE NOT 2 Q D 4 ASSEMBLY TESTED FOR THIS SPECIFIC USE. SEE NOTE 1. 4- I-- STEEL PIPE SLEEVE EXTENDED 1 1/2" ABOVE SLAB MUST BE INSIDE OF THE GYPSUM BOARD AT WALL. SEE NOTE 3. I I I FLOOR SLAB PER U.L. DESIGN NUMBER I I II . II (SEE "PLAN REVIEW DATA" ON PROJECT � DESIGN INFORMATION NUOMBER) ET X1.1 FOR U.L. D ETAI L 2 NOT TO SCALE PENETRATIONS AT SLAB IF APPROVED IN ADVANCE BY ALL AUTHORITIES HAVING JURISDICTION, A "5 -SIDED ENCLOSURE" FOR THE PROTECTION OF RECESSED ITEMS IN A RATED FIRE BARRIER AND /OR RATED SMOKE BARRIER WOULD BE ACCEPTABLE FOR USE IN A ONE -HOUR (OR LESS) RATED BARRIER, BUT ONLY IF IT IS CONSTRUCTED TO MEET ALL REQUIREMENTS OF THE USG TEST REFERENCE N0, W #933. (SEE LETTER FROM UNDERWRITERS LABORATORIES, INC., DATED JULY 8, 2002 ADDRESSED TO USG CORPORATION WITH U.CS REFERENCE FILE R1319.) THE ONE -HOUR RATED FIRE BARRIER AND /OR ONE -HOUR RATED SMOKE BARRIER WOULD HAVE TO BE CONSTRUCTED USING 6 ", 20 GAGE (MINIMUM) METAL STUDS. THE MAXIMUM ALLOWED SIZE OF THE RECESSED METALLIC ELECTRICAL CABINET IS 20" WIDE BY 5 1/4" DEEP BY 56" HIGH. NOTE: THIS "5 -SIDED ENCLOSURE" CANNOT BE USED IN ANY RATED SHAFTWALL FIRE BARRIER, RATED SHAFTWALL SMOKE BARRIER, RATED FIRE BARRIER OR RATED SMOKE BARRIER WITH A RATING GREATER THAN ONE -HOUR. "5 -SIDED ENCLOSURE" IN A ONE -HOUR RATED BARRIER FOR METALLIC ELECTRICAL CABINET BOXES OF 20" MAXIMUM WIDTH 2BBY 5 1/4 " MAXIMUM DEPTH DETAIL BY 56 MAXIMUM HEIGHT NOTE: IF PIPE IS TO BE INSULATED, DO NOT RUN PIPE INSULATION THROUGH THE WALL /BARRIER. PROVIDE APPROVED TESTED "THROUGH - PENETRATION FIRESTOP SYSTEM" INSTALLED AS TESTED FOR THE SPECIFIC APPROVED FIRE - RESISTANCE RATED WALL /BARRIER ASSEMBLY. THEN FLARE PIPE INSULATION ONTO FACE OF WALL /BARRIER AROUND PIPE ON BOTH SIDES OF WALL, AND SEAL TO FACE OF WALL /BARRIER WITH INSULATION MASTIC. PROVIDE CONTINUOUS TYPE 'G' SCREWS AT 6" O.C. BEAD OF JOINT (MAXIMUM). LEAVE EXPOSED. EDGES OFDPATOCHND OPENINGS OVER 3" DIAMETER JOINT AT SECOND TYPE 'G' SCREWS LEAVE EXPOSED LAYER WHERE "BUTTER" ENTIRE BACK SIDE OF ALL PATCHES WITH APPLICABLE 7 GYPSUM BOARD JOINT COMPOUND SO THAT IT OOZES OUT ON ALL SIDES OF PATCH. (DO NOT REMOVE EXCESS OOZE.) ATTACH WITH SCREWS AS NOTED. LEAVE ALL SCREWS EXPOSED. PATCHES SHALL BE OF SAME FIRE RATED TYPE AND THICKNESS OF GYPSUM o — 0— BOARD AND IN SAME NUMBER OF LAYERS AS REQUIRED FOR RATED WALL /BARRIER. SEE GENERAL NOTES BELOW. o o— o o �- -- ion I 13„ CUT FIRE RATED 3„ GYPSUM BOARD PATCH 6” 3" 6" TO FIT WITHIN TOLERANCE ALLOWED BY APPROVED MINIMUM MAX MINIMUM TESTED "THROUGH - PENETRATION FIRESTOP SYSTEM" (SEE GENERAL NOTES AT RIGHT) OPENINGS UP TO 3" DIAMETER NOTES: 1. IF ANY PIPES ARE TO BE INSULATED, DO NOT RUN INSULATION THROUGH A RATED FIRE BARRIER OR RATED SMOKE BARRIER. AFTER SEALING PENETRATIONS AROUND PIPE THROUGH THE WALL WITH "THROUGH - PENETRATION FIRESTOP SYSTEM ", FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH SIDES OF WALL, AND SEAL TO FACE OF WALL WITH INSULATION MASTIC. 2. COMBUSTIBLE CONDUIT AND /OR COMBUSTIBLE PIPE IS NOT ALLOWED. •••• vut, W i goose ••• i . U •ii • i • i • . E J . J Y • U • L U ••+,• 1i i• 3 5/8" (MINIMUM) SEAL PENETRATIONS WITH APPROVED TES I EU METAL STUDS AT "THROUGH- PENETRATION FIRESTOP SYSTEM" AS E N 16" O.C. (MAXIMUM) INDICATED BELOW F O NON- COMBUSTIBLE PIPE OR CONDUIT B C METAL RUNNER VERIFY REQUIRED NUMBER OF LAYERS AND TYPE "A" SECTION OF 5/8" TYPE "X" GYPSUM BOARD © Cop 2' -0" MAXIMUM FOR FULL - HEIGHT 2' -0" MAXIMUM FOR FULL- HEIGHT I 20 GAGE (MINIMUM) METAL STUDS I 20 GAGE (MINIMUM) METAL STUDS J 1' -4" MAXIMUM r• I I A (TYPICAL) I METAL RUNNER BEHIND III i 2" MAXIMUM I S GYPSUM BOARD III III (TYPICAL) I � I I (SECURELY ATTACHED - -I h - 1 -I - - - - - - -- { I I i TO VERTICAL STUDS) I { I I II _ II -------- --- - -- 1I I A I( I- "A" I I 2" MAXIMUM 1 1 I I I I (TYPICAL) 1 — ....J_I__ � I —_11 - — — — — _ — I I � II I { I' jr --- — — — — - --- — - — I- - -_l I-- - -_ - -- ---- --- - -1 1 1{ I I I I I NON- COMBUSTIBLE I �� III A III I I I I CONDUIT OR PIPING I I I I PACK TIGHTLY WITH "MINERAL FIBER SAFING INSULATION FOR�`�g'�• 1' -4" MAXIMUM FULL DEPTH OF BARRIER, AND SEAL PENETRATIONS WITH „ C�O Q APPROVED TESTED "THROUGH- PENETRATION FIRESTOP SY`aTEM;% 1aa (TYPICAL) PER REQUIREMENTS OF:+'��'� �G� , " �� SPECIFICATION SECTION 07 8413, B E LEVAT I 0 N 2006 NFPA 101, LIFE SAFETY CODE SECTION 8.3.5 �S�%o Cansu' AND 2006 IBC SECTION 712.3. 2007 FBC SECTION 712.3 AND 2007 FLORIDA EDITION OF NFPA 101, LIFE SAFETY CODE t SECTION 8.3.5.E TYPICAL MULTIPLE NON- COMBUSTIBE��' CONDUIT OR PIPE PENETRATIONS 6( DETAIL THROUGH RATED FIRE BARRIERS Hol NOT TO SCALE AND /OR RATED SMOKE BARRIERS NOTES: 1. SEE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR ADDITIONAL REQUIREMENTS FOR THIS BARRIER, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET X1.1 2. COMPLY WITH ALL REQUIREMENTS OF THE FBC SECTION 713 -FIRE RESISTANT JOINT SYSTEMS. ALL JOINTS INSTALLED IN OR BETWEEN FIRE- RESISTANCE -RATED WALLS/ BARRIERS OR FLOOR ASSEMBLIES AND ROOF ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED "FIRE- RESISTANT JOINT SYSTEM" DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE - RESISTANCE RATING OF THE WALL /BARRIER, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED. FIRE - RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079. COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8446 3. PROVIDE LEAD -LINED TYPE "RB -LBG GYPSUM BOARD WHERE LEAD- LINING IS INDICATED ON THE FLOOR PLANS, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY THAT SPECIFICALLY APPLIES TO A LEAD -LINED RATED BARRIER AS REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET X1.1 4. IN HEALTHCARE FACILITIES, EVEN IN NON -RATED PARTITIONS, SEAL ALL PENETRATIONS TO COMPLY WITH 2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES SECTIONS 2.1- 8.2.2.11 & 2.1- 8.2.3.5 AND TABLE 2.1 -1 PROVIDE APPROVED "FIRE - RESISTANT JOINT SYSTEM" PER NOTE 2 ABOVE. ALSO, COMPLY WITH REQUIREMENTS INDICATED ON PROJECT INFORMATION SHEET X1.1 UNDER "WALLS /PARTITIONS/ BARRIERS LEGEND ". SEAL ALL/ "HEAD -OF- WALLS" BOTH AIR -TIGHT AND SOUND- TIGHT. 3 5/8" (MINIMUM) METAL STUDS AT 16" O.C. (MAXIMUM)- - FINISH CEILING METAL STUD RUNNERS SHALL BE ATTACHED TO COMPLY WITH DESIGNATED TESTED ASSEMBLY. WHERE AN STC RATING IS REQUIRED, THE RUNNERS SHALL BE SET IN TWO CONTINUOUS BEADS OF ACOUSTICAL SEALANT. PROVIDE 3" MINIMUM FULL - HEIGHT SOUND ATTENUATION BLANKETS WHERE INDICATED AND /OR WHERE AN STC RATING IS REQUIRED CONCRETE FLOOR SLAB------\A DETAIL THROUGH -- PENETRATION FIRESTOP PATCHING & SEALING PLNE I HAI IUWD NOT TO SCALE SYSTEM SCHEDULE DETAIL IN RATED FIRE BARRIERS AND /OR is NOT TO SCALE RATED SMOKE BARRIERS ra IGINEERING Z - ARCHITECTURE 55 S. Orange Avenue Suite 1600 Mando, Florida 32801 PH: 407.841.9050 vmtic- engineers.com EB #0000015 ✓right 2009 TLC Engineering for Architecture, Inc 3„ JOINT AT SECOND LAYER WHERE MINI CENTERLINE OF STUDS I MIN APPLICABLE C TYPE 'S' SCREWS I I ,•� ew E (MINIMUM OF TWO ° 0 0 � PER SECTION). � o 1 CO . LEAVE EXPOSED. Q M 0 � LL 3 L.� O N �E z s CUT FIRE RATED ca o �- GYPSUM BOARD PATCH dC Z TO FIT WITHIN TOLERANCE o 0 0 ALLOWED BY APPROVED tant: TESTED "THROUGH - H A M M M I T ! A N D PENETRATION FIRESTOP o 1 0 o o o - o - - - - - - z Hollywood Blvd. SYSTEM „ (SEE GENERAL Suite I - z K Florida NOTES BELOW RIGHT) 954.981.9100 FIRM'S FLORIDA PROVIDE CONTINUOUS TYPE 'G' SCREWS AT 6" O.C. BEAD OF JOINT (MAXIMUM). LEAVE EXPOSED. EDGES OFDPATOCHND OPENINGS OVER 3" DIAMETER JOINT AT SECOND TYPE 'G' SCREWS LEAVE EXPOSED LAYER WHERE "BUTTER" ENTIRE BACK SIDE OF ALL PATCHES WITH APPLICABLE 7 GYPSUM BOARD JOINT COMPOUND SO THAT IT OOZES OUT ON ALL SIDES OF PATCH. (DO NOT REMOVE EXCESS OOZE.) ATTACH WITH SCREWS AS NOTED. LEAVE ALL SCREWS EXPOSED. PATCHES SHALL BE OF SAME FIRE RATED TYPE AND THICKNESS OF GYPSUM o — 0— BOARD AND IN SAME NUMBER OF LAYERS AS REQUIRED FOR RATED WALL /BARRIER. SEE GENERAL NOTES BELOW. o o— o o �- -- ion I 13„ CUT FIRE RATED 3„ GYPSUM BOARD PATCH 6” 3" 6" TO FIT WITHIN TOLERANCE ALLOWED BY APPROVED MINIMUM MAX MINIMUM TESTED "THROUGH - PENETRATION FIRESTOP SYSTEM" (SEE GENERAL NOTES AT RIGHT) OPENINGS UP TO 3" DIAMETER NOTES: 1. IF ANY PIPES ARE TO BE INSULATED, DO NOT RUN INSULATION THROUGH A RATED FIRE BARRIER OR RATED SMOKE BARRIER. AFTER SEALING PENETRATIONS AROUND PIPE THROUGH THE WALL WITH "THROUGH - PENETRATION FIRESTOP SYSTEM ", FLARE INSULATION ONTO FACE OF WALL AROUND PIPE ON BOTH SIDES OF WALL, AND SEAL TO FACE OF WALL WITH INSULATION MASTIC. 2. COMBUSTIBLE CONDUIT AND /OR COMBUSTIBLE PIPE IS NOT ALLOWED. •••• vut, W i goose ••• i . U •ii • i • i • . E J . J Y • U • L U ••+,• 1i i• 3 5/8" (MINIMUM) SEAL PENETRATIONS WITH APPROVED TES I EU METAL STUDS AT "THROUGH- PENETRATION FIRESTOP SYSTEM" AS E N 16" O.C. (MAXIMUM) INDICATED BELOW F O NON- COMBUSTIBLE PIPE OR CONDUIT B C METAL RUNNER VERIFY REQUIRED NUMBER OF LAYERS AND TYPE "A" SECTION OF 5/8" TYPE "X" GYPSUM BOARD © Cop 2' -0" MAXIMUM FOR FULL - HEIGHT 2' -0" MAXIMUM FOR FULL- HEIGHT I 20 GAGE (MINIMUM) METAL STUDS I 20 GAGE (MINIMUM) METAL STUDS J 1' -4" MAXIMUM r• I I A (TYPICAL) I METAL RUNNER BEHIND III i 2" MAXIMUM I S GYPSUM BOARD III III (TYPICAL) I � I I (SECURELY ATTACHED - -I h - 1 -I - - - - - - -- { I I i TO VERTICAL STUDS) I { I I II _ II -------- --- - -- 1I I A I( I- "A" I I 2" MAXIMUM 1 1 I I I I (TYPICAL) 1 — ....J_I__ � I —_11 - — — — — _ — I I � II I { I' jr --- — — — — - --- — - — I- - -_l I-- - -_ - -- ---- --- - -1 1 1{ I I I I I NON- COMBUSTIBLE I �� III A III I I I I CONDUIT OR PIPING I I I I PACK TIGHTLY WITH "MINERAL FIBER SAFING INSULATION FOR�`�g'�• 1' -4" MAXIMUM FULL DEPTH OF BARRIER, AND SEAL PENETRATIONS WITH „ C�O Q APPROVED TESTED "THROUGH- PENETRATION FIRESTOP SY`aTEM;% 1aa (TYPICAL) PER REQUIREMENTS OF:+'��'� �G� , " �� SPECIFICATION SECTION 07 8413, B E LEVAT I 0 N 2006 NFPA 101, LIFE SAFETY CODE SECTION 8.3.5 �S�%o Cansu' AND 2006 IBC SECTION 712.3. 2007 FBC SECTION 712.3 AND 2007 FLORIDA EDITION OF NFPA 101, LIFE SAFETY CODE t SECTION 8.3.5.E TYPICAL MULTIPLE NON- COMBUSTIBE��' CONDUIT OR PIPE PENETRATIONS 6( DETAIL THROUGH RATED FIRE BARRIERS Hol NOT TO SCALE AND /OR RATED SMOKE BARRIERS NOTES: 1. SEE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR ADDITIONAL REQUIREMENTS FOR THIS BARRIER, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET X1.1 2. COMPLY WITH ALL REQUIREMENTS OF THE FBC SECTION 713 -FIRE RESISTANT JOINT SYSTEMS. ALL JOINTS INSTALLED IN OR BETWEEN FIRE- RESISTANCE -RATED WALLS/ BARRIERS OR FLOOR ASSEMBLIES AND ROOF ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED "FIRE- RESISTANT JOINT SYSTEM" DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE - RESISTANCE RATING OF THE WALL /BARRIER, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED. FIRE - RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079. COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8446 3. PROVIDE LEAD -LINED TYPE "RB -LBG GYPSUM BOARD WHERE LEAD- LINING IS INDICATED ON THE FLOOR PLANS, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY THAT SPECIFICALLY APPLIES TO A LEAD -LINED RATED BARRIER AS REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET X1.1 4. IN HEALTHCARE FACILITIES, EVEN IN NON -RATED PARTITIONS, SEAL ALL PENETRATIONS TO COMPLY WITH 2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES SECTIONS 2.1- 8.2.2.11 & 2.1- 8.2.3.5 AND TABLE 2.1 -1 PROVIDE APPROVED "FIRE - RESISTANT JOINT SYSTEM" PER NOTE 2 ABOVE. ALSO, COMPLY WITH REQUIREMENTS INDICATED ON PROJECT INFORMATION SHEET X1.1 UNDER "WALLS /PARTITIONS/ BARRIERS LEGEND ". SEAL ALL/ "HEAD -OF- WALLS" BOTH AIR -TIGHT AND SOUND- TIGHT. 3 5/8" (MINIMUM) METAL STUDS AT 16" O.C. (MAXIMUM)- - FINISH CEILING METAL STUD RUNNERS SHALL BE ATTACHED TO COMPLY WITH DESIGNATED TESTED ASSEMBLY. WHERE AN STC RATING IS REQUIRED, THE RUNNERS SHALL BE SET IN TWO CONTINUOUS BEADS OF ACOUSTICAL SEALANT. PROVIDE 3" MINIMUM FULL - HEIGHT SOUND ATTENUATION BLANKETS WHERE INDICATED AND /OR WHERE AN STC RATING IS REQUIRED CONCRETE FLOOR SLAB------\A DETAIL THROUGH -- PENETRATION FIRESTOP PATCHING & SEALING PLNE I HAI IUWD NOT TO SCALE SYSTEM SCHEDULE DETAIL IN RATED FIRE BARRIERS AND /OR is NOT TO SCALE RATED SMOKE BARRIERS ra IGINEERING Z - ARCHITECTURE 55 S. Orange Avenue Suite 1600 Mando, Florida 32801 PH: 407.841.9050 vmtic- engineers.com EB #0000015 ✓right 2009 TLC Engineering for Architecture, Inc ons: Date Description I LUIS CANO ; A..R,- 0 01.5 8 9 4 0 -ct No.: 109355 Date: 10/0912009 vn By: oved By: e: ving Title: IISCELLANEOUS )ETA ILS wing No.: A8m2_ 1 C M ew E T � � o CO . Q M 0 w r LL 3 L.� O N �E ca n dC Z 0 tant: R E S H A M M I T ! A N D A R T N E R S 130 Hollywood Blvd. Suite '210 lywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT, NO. 4AP000034/EB0003806 IB26000797 ons: Date Description I LUIS CANO ; A..R,- 0 01.5 8 9 4 0 -ct No.: 109355 Date: 10/0912009 vn By: oved By: e: ving Title: IISCELLANEOUS )ETA ILS wing No.: A8m2_