09-979-009ALL GYPSUM BOARD PANELS 4' -0" GYPSUM BOARD PANEL SHALL BE APPLIED VERTICALLY � I 4' -0" GYPSUM BOARD PANEL STAGGER VERTICAL JOINTS SO THAT THEY OCCUR OVER DIFFERENT I 16" O.C. STUDS ON OPPOSITE SIDES OF PARTITION AND STAGGER JOINTS OF SECOND LAYER FROM FIRST LAYER. COMPLY WITH REQUIREMENTS I MAXIMUM IN "WALLS /PARTITIONS /BARRIERS LEGEND" ON SHEET X1.1 STUD I SPACING ,I F 4' -0" GYPSUM BOARD PANEL I JOINTS IN FINISH LAYER JI ' SHALL RECEIVE TAPE AND JOINT COMPOUND I FOR ALL WALLS /PARTITIONS /BARRIERS I 4' -0 GYPSUM BOARD PANEL FOR NON -RATED PARTITIONS FINISH CEILING DECKS (SEE "WALLS /PARTITIONS /BARRIERS LEGEND" ON SHEET X1.1) + ALTHOUGH HORIZONTAL JOINTS MAY + ' ' NOT NORMALLY BE REQUIRED TO BE STAGGERED IN NON -RATED PARTITIONS, THEY MAY BE REQUIRED I I TO BE STAGGERED TO COMPLY WITH AN STC RATING. VERIFY. ALL HORIZONTAL JOINTS SHALL OCCUR ABOVE THE CEILING. I GYPSUM BOARD PANEL LENGTHS I I I SHALL ALLOW FOR JOINTS TO BE ABOVE THE CEILING (USE 1 8' -0" MINIMUM BOARD LENGTH IN SPACES WITHOUT CEILINGS) FLOOR SLAB FOR ALL PARTITIONS: CUT GYP BD TO WITHIN 112" OF DECK FLUTES AND SEAL AS INDICATED ON "WALLS /PARTITIONS /BARRIERS LEGEND" ~ FOR RATED FIRE BARRIERS � SMOKE FINISH CEILING DECK BARRIERS (SEE "WALLS /PARTITIONS/ BARRIERS LEGEND' ON SHEET X1:1) HORIZONTAL JOINTS ARE I I I REQUIRED TO BE STAGGERED - - - - - -- - �- - - - - ' - -- -- - - -� -- -- -� - 2,- 0" (MINIMUM) O.C. AND ALL JOINTS SHALL OCCUR ABOVE THE CEILING BY USING VARYING ' LENGTHS OF GYPSUM BOARD PANELS GYPSUM BOARD PANEL LENGTHS �1 SHALL ALLOW FOR HORIZONTAL JOINTS TO BE ABOVE THE ' CEILING (USE 8'--0" MINIMUM AT SPACES WITHOUT CEILINGS) FLOOR SLAB 1/4" MINIMUM/ 1/2" MAXIMUM JOINT AT ALL FLOOR SLABS. SEAL AS INDICATED ON WALLS /PARTITIONS /BARRIERS LEGEND" ON SHEET X1.1 DETAIL LOCATION OF JOINTS IN GYPSUM NOT TO SCALE BOARD WALLS /PARTITIONS /BARRIERS NOTES: 1. SEE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR ADDITIONAL REQUIREMENTS FOR THIS BARRIER, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 2. COMPLY WITH ALL REQUIREMENTS OF THE FBC SECTION 713 - FIRE RESISTANT JOINT SYSTEMS. ALL JOINTS INSTALLED IN OR BETWEEN FIRE - RESISTANCE -RATED WALLS/ BARRIERS OR FLOOR ASSEMBLIES AND ROOF ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED "FIRE- RESISTANT JOINT SYSTEM" DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE - RESISTANCE RATING OF THE WALL /BARRIER, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED. FIRE- RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079. COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8446. 3. SEAL ALL PENETRATIONS THROUGH THESE BARRIERS TO COMPLY WITH REQUIREMENTS INDICATED ON PROJECT INFORMATION SHEET A8.1 4. PROVIDE LEAD -LINED TYPE "RB -LBG" GYPSUM BOARD WHERE LEAD - LINING IS INDICATED ON THE FLOOR PLANS, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY THAT SPECIFICALLY APPLIES TO A LEAD -LINED RATED BARRIER AS REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 BOTH LAYERS OF 5/8" TYPE "X" GYPSUM BOARD SHALL BE CUT TO FIT WITHIN DECK PROVIDE APPROVED "FIRE- FLUTES PER MAXIMUM GAP ALLOWED BY RESISTANT JOINT SYSTEM" APPROVED "FIRE RESISTANT JOINT SYSTEM" PER NOTE 2 ABOVE. ALSO, PER NOTE 2 ABOVE (COMPLY WITH NOTE 4 COMPLY WITH REQUIREMENTS FOR RATED LEAD -LINED BARRIERS) INDICATED ON PROJECT INFORMATION SHEET X1.1 NOTES: 1. SEE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR ADDITIONAL REQUIREMENTS FOR THIS BARRIER, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1. 2. COMPLY WITH ALL REQUIREMENTS OF THE FBC SECTION 713 -FIRE RESISTANT JOINT SYSTEMS. ALL JOINTS INSTALLED IN OR BETWEEN FIRE - RESISTANCE -RATED WALLS/ BARRIERS OR FLOOR ASSEMBLIES AND ROOF ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED "FIRE- RESISTANT JOINT SYSTEM" DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE - RESISTANCE RATING OF THE WALL /BARRIER, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED. FIRE - RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079. COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8446. 3, IN HEALTH CARE FACILITIES, EVEN IN NON -RATED CMU PARTITIONS, SEAL ALL PENETRATIONS TO COMPLY WITH 2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES SECTION 2.1- 8.2.3.5. 4. WHERE INDICATED AND /OR REQUIRED, PROVIDE CONCRETE MASONRY UNITS THAT WILL PROVIDE THE REQUIRED STC RATING. USE "SOUNDBLOX" THAT IS TESTED FOR BOTH THE REQUIRED FIRE RATING AND THE REQUIRED STC RATING. SEE SPECIFICATIONS. I ,tql FLOOR OR ROOF ASSEMBLY PER U.L. DESIGN NUMBER (SEE THE PLAN REVIEW DATA ON SHEET X1.1 FOR THE DESIGNATED U.L. DESIGN NUMBER FOR THE FLOOR AND ROOF ASSEMBLIES) PROVIDE APPROVED "FIRE- RESISTANT JOINT SYSTEM" PER NOTE 2 ABOVE. ALSO, COMPLY WITH REQUIREMENTS INDICATED ON PROJECT INFORMATION SHEET X1.1 UNDER "WALLS /PARTITIONS /BARRIERS LEGEND ". SEAL ALL "HEAD -OF- WALLS" BOTH AIR -TIGHT AND SOUND- TIGHT. STRUCTURAL BRACE (SEE STRUCTURAL FOR TYPE, SIZE AND LOCATIONS OF BRACES) RATED CONCRETE MASONRY UNITS. SEE FLOOR PLANS AND "WALLS /PARTITIONS /BARRIERS LEGEND" ON SHEET X1.1 FOR SIZE AND RATING OF CONCRETE MASONRY UNITS. SEE STRUCTURAL DRAWINGS FOR REINFORCEMENT OF CMU. ALSO, SEE NOTE 4 ABOVE. RAKE MORTAR JOINT AND ADD CONTINUOUS ACOUSTICAL SEALANT BEAD CONCRETE FLOOR SLAB SEE STRUCTURAL FOR CONNECTION OF CMU AND ITS REINFORCMENT INTO CONCRETE FLOOR SLAB RATED FIRE BARRIER AND /OR DETAIL RATED SMOKE BARRIER USING NOT TO SCALE CONCRETE MASONRY UNITS [CMU] TAPE 1. JOINT COMPOUND (TYPICAL) LOWER PRIORITY PARTITION /BARRIER LOWER PRIORITY PARTITION/ BARRIER - 11 ^ 91 TAPE & SEAL HIGHER PRIORITY WALL/ PARTITION /BARRIER EVEN WHEN HIDDEN BEHIND INTERSECTING LOWER PRIORITY PARTITION /BARRIER (TYPICAL) TAPE Ec JOINT COMPOUND (TYPICAL) HIGHER PRIORITY WALL /PARTITION /BARRIER HIGHER PRIORITY WALL/ PARTITION /BARRIER TAPE Et JOINT COMPOUND (TYPICAL) LOWER PRIORITY PARTITION /BARRIER "D" \ --TAPE & JOINT "Ell COMPOUND (TYPICAL) HIGHER PRIORITY WALL/ PARTITION /BARRIER "B it LOWER PRIORITY PARTITION /BARRIER TAPE AND SEAL BEHIND INTERSECTING LOWER PRIORITY PARTITION/ BARRIER (TYPICAL) HIGHER PRIORITY WALL/ PARTITION /BARRIER TAPE & SEAL HIGHER PRIORITY WALL/ PARTITION /BARRIER BEHIND INTERSECTING LOWER PRIORITY PARTITION /BARRIER _ (TYPICAL) LOWER PRIORITY PARTITION /BARRIER NOTES- 1. REFER TO FLOOR PLANS AND TO "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR NUMBER OF LAYERS & TYPE OF GYPSUM BOARD AND FOR REQUIRED TYPE AND THICKNESS OF SOUND ATTENUATION BLANKETS. 2. THE HIGHER PRIORITY WALL /BARRIER /PARTITION SHALL ALWAYS PASS CONTINUOUSLY THROUGH THE LOWER PRIORITY BARRIER /PARTITION 3. TAPE AND SEAL ALL JOINTS IN GYPSUM BOARD IN HIGHER PRIORITY WALLS /PARTITIONS/ BARRIERS EVEN WHEN JOINT IS HIDDEN BEHIND INTERSECTING OR ABUTTING LOWER PRIORITY BARRIERS /PARTITIONS 4. ALTERNATE LAYERS OF GYPSUM BOARD SHALL OVERLAP AT CORNER INTERSECTIONS OF MULTI - LAYERED RATED GYPSUM BOARD WALLS /BARRIERS 5. SEE DETAIL 2/A8.3 "PRIORITY LEGEND FOR ABUTMENT OF DIFFERING WALLS /PARTITIONS/ BARRIERS" 6. CRITICAL: THESE DETAILS APPLY TO BOTH "FIRE RATING PRIORITY" AND TO "SOUND TRANSMISSION CLASS [STC] PRIORITY" DETAI L INTERSECTION OF DIFFERING PRIORITY NOT TO SCALE WALLS /PARTITIONS /BARRIERS wvwo wow • 0 00000 000 • • WALLS/PARTITIONS/BARRIERS LEGEND*...' • GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS •y 1. EACH INDIVIDUAL WALL /PARTITION /BARRIER ASSEMBLY SHALL COMPLY WITH THE TESTED ASSEMBLY REFERENCED BELOW. • +• •'. 2. ALL ASSEMBLIES USING GYPSUM BOARD: COMPLY WITH THE MOST STRINGENT OF THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE UNDERWRITERS LABORATORIES U.L. FIRE RESISTANCE DIRECTORY AND THE MOST CURRENT EDITION OF THE "GYPSUM ASSOC.ADON .. GA -600 FIRE RESISTANCE DESIGN MANUAL ". SEE DETAIL 5/A8.1 "LOCATION OF JOINTS IN GYPSUM BOARD WALLS /PARTITIONS /BARRIER ' FOR DETAILS PERTAINING TO METAL STUD AND GYPSUM BOARD WALLS, SEE SPECIFICATIONS IN THE PROJECT MANUAL AND DETAILS IN THESE DRAWINGS FOR REQUIRED GAGE OF METAL STUDS. 0.00 • •. 3. HEAD OF WALLS: WALLS /PARTITIONS /BARRIERS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE SHALL HAVE ALL LAYERS OF THE GYPSUM BOARD CUT TO FIT WITHIN 1/2 INCH OF THE SHAPE OF THE DECK ABOVE. ALL LAYERS OF THE GYPSUM BOARD SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARDS WITH FLEXIBLE SEALANT PER GA- 600 -03 FIRE RESISTANCE DESIGN MANUAL (FIGURE 9). THIS GAP SHALL BE SEALED AIR -TIGHT AND SOUND- TIGHT. (A) AT ALL RATED WALLS /BARRIERS, PROVIDE AN APPROVED U.L. TESTED FIRE - RESISTANT JOINT SYSTEM TO COMPLY WITH NOTE 6 BELOW. 4. PENETRATIONS: THE GYPSUM BOARD SHALL BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELECTRICAL OUTLET BOXES AND THE GYPSUM BOARD DOES NOT EXCEED 1/8 INCH. SEE DETAIL 3/A8.1 "METALLIC ELECTRICAL OUTLET BOXES RECESSED IN RATED FIRE BARRIERS AND /OR RATED SMOKE BARRIERS . THE GYPSUM BOARD SHALL BE CUT TO FIT WITHIN A 1/4 INCH MAXIMUM TOLERANCE AROUND ALL OTHER PENETRATIONS AND SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT. THE GAPS AROUND ALL PENETRATIONS SHALL BE SEALED AIR -TIGHT AND SOUND- TIGHT. COMPLY WITH NOTE 6 BELOW. (A) AT ALL RATED WALLS /BARRIERS, IF AT ANY POINT AROUND THE PENETRATION THE GAP IS GREATER THAN INDICATED HEREIN, PROVIDE AN APPROVED U.L. TESTED "THROUGH - PENETRATION FIRESTOP SYSTEM" TO COMPLY WITH NOTE 6 BELOW, AND COMPLY WITH SPECIFICATION SECTION 07 8413. (B) IN HEALTH CARE FACILITIES, SEAL PENETRATIONS THROUGH BOTH RATED BARRIERS AND NON -RATED PARTITIONS TO COMPLY WITH SOUND TRANSMISSION LIMITATIONS PER NOTE 7 BELOW AND WITH THE "2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES" SECTION 8.2.3.5. 5, BOTTOM OF WALLS: THE GAP AT THE BOTTOM OF THE GYPSUM BOARD ON ALL WALLS SHALL BE 1/4 INCH MINIMUM AND 1/2 INCH MAXIMUM ABOVE THE CONCRETE FLOOR SLAB, AND IT SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT. THIS GAP SHALL BE SEALED AIR -TIGHT AND SOUND- TIGHT. (A) AT ALL RATED WALLS /BARRIERS WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION, IF THE GAP IS GREATER THAN, 1/2 INCH AT ANY POINT ALONG THE BOTTOM OF A RATED WALL /BARRIER, PROVIDE AN APPROVED U.L. TESTED "FIRE - RESISTANT ' JOINT SYSTEM" PER *IBC* *FBC * * --- * SECTION 713; AND COMPLY WITH SPECIFICATION SECTION 07 8446. 6, FOR ALL RATED WALLS /BARRIERS: PER THE REQUIREMENTS OF *IBC* *FBC * * --- * SECTIONS 712 AND 713, PROVIDE APPROVED U.L. TESTED "FIRE- RESISTANT JOINT SYSTEM" OR "THROUGH- PENETRATION FIRESTOP SYSTEM" TO COMPLY WITH ALL REQUIREMENTS OF EACH SPECIFIC CONDITION AS APPROPRIATE FOR ALL ADJACENT BUILDING COMPONENTS PER THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE . FIRE RESISTANCE DIRECTORY - VOLUME 2A ", AND COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8413 "PENETRATION FIRESTOPPING" AND SPECIFICATION SECTION 07 8446 "FIRE- RESISTIVE JOINT SYSTEMS ". 7. SOUND TRANSMISSION LIMITATIONS: (A) SEE THE NEW CONSTRUCTION FLOOR PLANS FOR NOTES AND KEYNOTES THAT PROVIDE ADDITIONAL INFORMATION REGARDING REQUIRED STC RATINGS. (B) IN HOSPITALS, COMPLY WITH *TABLE 2.1- -1 "SOUND TRANSMISSION LIMITATIONS IN GENERAL HOSPITALS" IN THE "2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES ".* *TABLE 2.2 -1 "SOUND TRANSMISSION LIMITATIONS IN GENERAL HOSPITALS" IN THE "2001 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTH CARE FACILITIES.* * ------- * TWO -HOUR RATED FIRE BARRIER 3 5/8" (MINIMUM) METAL STUDS AT V -4" MAXIMUM O.C. (UNLESS CLOSER SPACING IS INDICATED).COMPLY WITH REQUIREMENTS OF "GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS" ABOVE. THIS FIRE BARRIER SHALL ALSO COMPLY WITH THE REQUIREMENTS OF U.L. DESIGN NUMBER U411, 2006 NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 AND 2006 IBC SECTIONS 706, 708, 712 & 713. 2007 FLORIDA EDITION OF NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 AND 2007 (W/ 2009) FBC SECTIONS 706, 708, 712 do 713. 5/8" TYPE "X" GYPSUM BOARD SHALL BE APPLIED VERTICALLY IN TWO LAYERS ON EACH SIDE. ATTACH ALL GYPSUM BOARD TO METAL STUDS WITH TYPE "S" STEEL SCREWS TO COMPLY WITH REFERENCED U.L. DESIGN NUMBER. STAGGER ALL VERTICAL FACE LAYER AND BASE LAYER JOINTS V -4" MINIMUM O.C. AND STAGGER ALL HORIZONTAL JOINTS 2' -0" MINIMUM O.C. ALL HORIZONTAL JOINTS SHALL OCCUR ABOVE THE CEILING. SEAL EACH LAYER OF GYPSUM BOARD TO FLOOR SLAB BELOW PER GENERAL NOTES 5 do 6 ABOVE. EXTEND EACH LAYER OF GYPSUM BOARD TO DECK ABOVE AND SEAL EACH LAYER OF GYPSUM BOARD TO DECK PER GENERAL NOTES 3 do 6 ABOVE. SEAL ALL PENETRATIONS PER GENERAL NOTES 4 & 6 ABOVE. USE DETAIL 1/A8.1 "PATCHING AND SEALING PENETRATIONS IN RATED FIRE BARRIERS AND /OR RATED SMOKE BARRIERS" ONLY IF PRE - APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. INSTALL 3" MINIMUM SOUND ATTENUATION BLANKETS FROM FLOOR TO DECK. SEE SPECIFICATION FOR SIZE AND TYPE. COMPLY WITH GENERAL NOTE 7 ABOVE REGARDING SOUND TRANSMISSION LIMITATIONS. TWO -HOUR RATED (CMU) FIRE BARRIER �,v�� �'%M UNDER WALLS/PARTITIONS/ - i i I - - i 1 i ­ - - � ����tiC� ONLY CLASSIFICATION D LAID OF MORTAR BARRIERS LEGEND ". SEAL ALL DETAIL 3M�E. COMPLY WITBHDT E REQUIREMENTS OF "GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS" ABOVE. 0t�,p�tt�', THIS FIRE BARRIER SHALL ALSO COMPLY WITH THE REQUIREMENTS OF U.L. DESIGN AND Co , "HEAD -OF- WALLS" BOTH �T,h ,/p�3..Q�� --' 2006 IBC SECTIONS 706, 708, 712 & 713. 2007 C� G OF NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 AND 2007 (W/ 2009) FBC -2 AIR -TIGHT AND SOUND- TIGHT. t�.. EXTEND CMU FIRE BARRIER TO DECK ABOVE AND SEAL WITH APPROVED U.L. "HEAD -OF -WALL JOINT SYSTEM." SEAL ALL PENETRATIONS WITH APPROVED U.L. r-�- FL "THROUGH- PENETRATION FIRESTOP SYSTEM." SEE FLOOR PLANS FOR LOCATIONS WHERE FURRING IS REQUIRED. FLOOR OR ROOF ASSEMBLY PER U.L. N PROVIDE 3" MINIMUM FULL - NUMBER (SEE THE "PLAN REVIEW DATA" ON PROJECT INFORMATION HEIGHT SOUND ATTENUATION SHEET X1.1 FOR THE DESIGNATED BLANKETS WHERE INDICATED U.L. DESIGN NUMBER FOR THE AND /OR WHERE AN STC RATING IS REQUIRED FLOOR AND ROOF ASSEMBLIES) FINISH CEILING -- MINIMUM OF TWO LAYERS OF 5/8" TYPE "X" GYPSUM BOARD ON EACH METAL STUD RUNNERS SIDE - ATTACHED TO COMPLY WITH DESIGNATED TESTED ASSEMBLY SHALL BE ATTACHED TO (COMPLY WITH NOTE 4 FOR RATED COMPLY WITH DESIGNATED LEAD -LINED BARRIERS) TESTED ASSEMBLY. WHERE AN STC RATING IS f-AT 3 5/8" (MINIMUM) METAL STUDS REQUIRED, THE RUNNERS 16" O.C. (MAXIMUM) SHALL BE SET IN TWO CONTINUOUS BEADS OF 1/4" MINIMUM/ 112" MAXIMUM GAP - ACOUSTICAL SEALANT. SEAL EACH LAYER OF GYPSUM BOARD (ON EACH SIDE OF BARRIER) TO CONCRETE SLAB WITH FLEXIBLE SEALANT CONCRETE FLOOR SLAB TO PROVIDE AIR -TIGHT AND SOUND -TIGHT CONDITION. IF THE GAP IS LARGER THAN 1/2 ", SEAL THE BOTTOM OF THE BARRIER WITH AN APPROVED "FIRE- RESISTANT JOINT SYSTEM" PER NOTE 2 ABOVE. DETAIL TWO -HOUR RATED FIRE BARRIER OR NOT TO SCALE TWO --HOUR RATED SMOKE BARRIER NOTES: 1. SEE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR ADDITIONAL REQUIREMENTS FOR THIS BARRIER, AND COMPLY WITH ALL REQUIREMENTS OF THE DESIGNATED TESTED ASSEMBLY REFERENCED IN THE "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1. 2. COMPLY WITH ALL REQUIREMENTS OF THE FBC SECTION 713 -FIRE RESISTANT JOINT SYSTEMS. ALL JOINTS INSTALLED IN OR BETWEEN FIRE - RESISTANCE -RATED WALLS/ BARRIERS OR FLOOR ASSEMBLIES AND ROOF ASSEMBLIES SHALL BE PROTECTED BY AN APPROVED "FIRE- RESISTANT JOINT SYSTEM" DESIGNED TO RESIST THE PASSAGE OF FIRE FOR A TIME PERIOD NOT LESS THAN THE REQUIRED FIRE - RESISTANCE RATING OF THE WALL /BARRIER, FLOOR OR ROOF IN OR BETWEEN WHICH IT IS INSTALLED. FIRE - RESISTANT JOINT SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH THE REQUIREMENTS OF EITHER ASTM E 1966 OR UL 2079. COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8446. 3, IN HEALTH CARE FACILITIES, EVEN IN NON -RATED CMU PARTITIONS, SEAL ALL PENETRATIONS TO COMPLY WITH 2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES SECTION 2.1- 8.2.3.5. 4. WHERE INDICATED AND /OR REQUIRED, PROVIDE CONCRETE MASONRY UNITS THAT WILL PROVIDE THE REQUIRED STC RATING. USE "SOUNDBLOX" THAT IS TESTED FOR BOTH THE REQUIRED FIRE RATING AND THE REQUIRED STC RATING. SEE SPECIFICATIONS. I ,tql FLOOR OR ROOF ASSEMBLY PER U.L. DESIGN NUMBER (SEE THE PLAN REVIEW DATA ON SHEET X1.1 FOR THE DESIGNATED U.L. DESIGN NUMBER FOR THE FLOOR AND ROOF ASSEMBLIES) PROVIDE APPROVED "FIRE- RESISTANT JOINT SYSTEM" PER NOTE 2 ABOVE. ALSO, COMPLY WITH REQUIREMENTS INDICATED ON PROJECT INFORMATION SHEET X1.1 UNDER "WALLS /PARTITIONS /BARRIERS LEGEND ". SEAL ALL "HEAD -OF- WALLS" BOTH AIR -TIGHT AND SOUND- TIGHT. STRUCTURAL BRACE (SEE STRUCTURAL FOR TYPE, SIZE AND LOCATIONS OF BRACES) RATED CONCRETE MASONRY UNITS. SEE FLOOR PLANS AND "WALLS /PARTITIONS /BARRIERS LEGEND" ON SHEET X1.1 FOR SIZE AND RATING OF CONCRETE MASONRY UNITS. SEE STRUCTURAL DRAWINGS FOR REINFORCEMENT OF CMU. ALSO, SEE NOTE 4 ABOVE. RAKE MORTAR JOINT AND ADD CONTINUOUS ACOUSTICAL SEALANT BEAD CONCRETE FLOOR SLAB SEE STRUCTURAL FOR CONNECTION OF CMU AND ITS REINFORCMENT INTO CONCRETE FLOOR SLAB RATED FIRE BARRIER AND /OR DETAIL RATED SMOKE BARRIER USING NOT TO SCALE CONCRETE MASONRY UNITS [CMU] TAPE 1. JOINT COMPOUND (TYPICAL) LOWER PRIORITY PARTITION /BARRIER LOWER PRIORITY PARTITION/ BARRIER - 11 ^ 91 TAPE & SEAL HIGHER PRIORITY WALL/ PARTITION /BARRIER EVEN WHEN HIDDEN BEHIND INTERSECTING LOWER PRIORITY PARTITION /BARRIER (TYPICAL) TAPE Ec JOINT COMPOUND (TYPICAL) HIGHER PRIORITY WALL /PARTITION /BARRIER HIGHER PRIORITY WALL/ PARTITION /BARRIER TAPE Et JOINT COMPOUND (TYPICAL) LOWER PRIORITY PARTITION /BARRIER "D" \ --TAPE & JOINT "Ell COMPOUND (TYPICAL) HIGHER PRIORITY WALL/ PARTITION /BARRIER "B it LOWER PRIORITY PARTITION /BARRIER TAPE AND SEAL BEHIND INTERSECTING LOWER PRIORITY PARTITION/ BARRIER (TYPICAL) HIGHER PRIORITY WALL/ PARTITION /BARRIER TAPE & SEAL HIGHER PRIORITY WALL/ PARTITION /BARRIER BEHIND INTERSECTING LOWER PRIORITY PARTITION /BARRIER _ (TYPICAL) LOWER PRIORITY PARTITION /BARRIER NOTES- 1. REFER TO FLOOR PLANS AND TO "WALLS /PARTITIONS /BARRIERS LEGEND" ON PROJECT INFORMATION SHEET A8.1 FOR NUMBER OF LAYERS & TYPE OF GYPSUM BOARD AND FOR REQUIRED TYPE AND THICKNESS OF SOUND ATTENUATION BLANKETS. 2. THE HIGHER PRIORITY WALL /BARRIER /PARTITION SHALL ALWAYS PASS CONTINUOUSLY THROUGH THE LOWER PRIORITY BARRIER /PARTITION 3. TAPE AND SEAL ALL JOINTS IN GYPSUM BOARD IN HIGHER PRIORITY WALLS /PARTITIONS/ BARRIERS EVEN WHEN JOINT IS HIDDEN BEHIND INTERSECTING OR ABUTTING LOWER PRIORITY BARRIERS /PARTITIONS 4. ALTERNATE LAYERS OF GYPSUM BOARD SHALL OVERLAP AT CORNER INTERSECTIONS OF MULTI - LAYERED RATED GYPSUM BOARD WALLS /BARRIERS 5. SEE DETAIL 2/A8.3 "PRIORITY LEGEND FOR ABUTMENT OF DIFFERING WALLS /PARTITIONS/ BARRIERS" 6. CRITICAL: THESE DETAILS APPLY TO BOTH "FIRE RATING PRIORITY" AND TO "SOUND TRANSMISSION CLASS [STC] PRIORITY" DETAI L INTERSECTION OF DIFFERING PRIORITY NOT TO SCALE WALLS /PARTITIONS /BARRIERS wvwo wow • 0 00000 000 • • WALLS/PARTITIONS/BARRIERS LEGEND*...' • GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS •y 1. EACH INDIVIDUAL WALL /PARTITION /BARRIER ASSEMBLY SHALL COMPLY WITH THE TESTED ASSEMBLY REFERENCED BELOW. • +• •'. 2. ALL ASSEMBLIES USING GYPSUM BOARD: COMPLY WITH THE MOST STRINGENT OF THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE UNDERWRITERS LABORATORIES U.L. FIRE RESISTANCE DIRECTORY AND THE MOST CURRENT EDITION OF THE "GYPSUM ASSOC.ADON .. GA -600 FIRE RESISTANCE DESIGN MANUAL ". SEE DETAIL 5/A8.1 "LOCATION OF JOINTS IN GYPSUM BOARD WALLS /PARTITIONS /BARRIER ' FOR DETAILS PERTAINING TO METAL STUD AND GYPSUM BOARD WALLS, SEE SPECIFICATIONS IN THE PROJECT MANUAL AND DETAILS IN THESE DRAWINGS FOR REQUIRED GAGE OF METAL STUDS. 0.00 • •. 3. HEAD OF WALLS: WALLS /PARTITIONS /BARRIERS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE SHALL HAVE ALL LAYERS OF THE GYPSUM BOARD CUT TO FIT WITHIN 1/2 INCH OF THE SHAPE OF THE DECK ABOVE. ALL LAYERS OF THE GYPSUM BOARD SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARDS WITH FLEXIBLE SEALANT PER GA- 600 -03 FIRE RESISTANCE DESIGN MANUAL (FIGURE 9). THIS GAP SHALL BE SEALED AIR -TIGHT AND SOUND- TIGHT. (A) AT ALL RATED WALLS /BARRIERS, PROVIDE AN APPROVED U.L. TESTED FIRE - RESISTANT JOINT SYSTEM TO COMPLY WITH NOTE 6 BELOW. 4. PENETRATIONS: THE GYPSUM BOARD SHALL BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELECTRICAL OUTLET BOXES AND THE GYPSUM BOARD DOES NOT EXCEED 1/8 INCH. SEE DETAIL 3/A8.1 "METALLIC ELECTRICAL OUTLET BOXES RECESSED IN RATED FIRE BARRIERS AND /OR RATED SMOKE BARRIERS . THE GYPSUM BOARD SHALL BE CUT TO FIT WITHIN A 1/4 INCH MAXIMUM TOLERANCE AROUND ALL OTHER PENETRATIONS AND SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT. THE GAPS AROUND ALL PENETRATIONS SHALL BE SEALED AIR -TIGHT AND SOUND- TIGHT. COMPLY WITH NOTE 6 BELOW. (A) AT ALL RATED WALLS /BARRIERS, IF AT ANY POINT AROUND THE PENETRATION THE GAP IS GREATER THAN INDICATED HEREIN, PROVIDE AN APPROVED U.L. TESTED "THROUGH - PENETRATION FIRESTOP SYSTEM" TO COMPLY WITH NOTE 6 BELOW, AND COMPLY WITH SPECIFICATION SECTION 07 8413. (B) IN HEALTH CARE FACILITIES, SEAL PENETRATIONS THROUGH BOTH RATED BARRIERS AND NON -RATED PARTITIONS TO COMPLY WITH SOUND TRANSMISSION LIMITATIONS PER NOTE 7 BELOW AND WITH THE "2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES" SECTION 8.2.3.5. 5, BOTTOM OF WALLS: THE GAP AT THE BOTTOM OF THE GYPSUM BOARD ON ALL WALLS SHALL BE 1/4 INCH MINIMUM AND 1/2 INCH MAXIMUM ABOVE THE CONCRETE FLOOR SLAB, AND IT SHALL BE SEALED FOR THE FULL DEPTH OF THE GYPSUM BOARD WITH FLEXIBLE SEALANT. THIS GAP SHALL BE SEALED AIR -TIGHT AND SOUND- TIGHT. (A) AT ALL RATED WALLS /BARRIERS WHERE REQUIRED BY THE AUTHORITY HAVING JURISDICTION, IF THE GAP IS GREATER THAN, 1/2 INCH AT ANY POINT ALONG THE BOTTOM OF A RATED WALL /BARRIER, PROVIDE AN APPROVED U.L. TESTED "FIRE - RESISTANT ' JOINT SYSTEM" PER *IBC* *FBC * * --- * SECTION 713; AND COMPLY WITH SPECIFICATION SECTION 07 8446. 6, FOR ALL RATED WALLS /BARRIERS: PER THE REQUIREMENTS OF *IBC* *FBC * * --- * SECTIONS 712 AND 713, PROVIDE APPROVED U.L. TESTED "FIRE- RESISTANT JOINT SYSTEM" OR "THROUGH- PENETRATION FIRESTOP SYSTEM" TO COMPLY WITH ALL REQUIREMENTS OF EACH SPECIFIC CONDITION AS APPROPRIATE FOR ALL ADJACENT BUILDING COMPONENTS PER THE REQUIREMENTS OF THE MOST CURRENT EDITION OF THE . FIRE RESISTANCE DIRECTORY - VOLUME 2A ", AND COMPLY WITH REQUIREMENTS OF SPECIFICATION SECTION 07 8413 "PENETRATION FIRESTOPPING" AND SPECIFICATION SECTION 07 8446 "FIRE- RESISTIVE JOINT SYSTEMS ". 7. SOUND TRANSMISSION LIMITATIONS: (A) SEE THE NEW CONSTRUCTION FLOOR PLANS FOR NOTES AND KEYNOTES THAT PROVIDE ADDITIONAL INFORMATION REGARDING REQUIRED STC RATINGS. (B) IN HOSPITALS, COMPLY WITH *TABLE 2.1- -1 "SOUND TRANSMISSION LIMITATIONS IN GENERAL HOSPITALS" IN THE "2006 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HEALTH CARE FACILITIES ".* *TABLE 2.2 -1 "SOUND TRANSMISSION LIMITATIONS IN GENERAL HOSPITALS" IN THE "2001 GUIDELINES FOR DESIGN AND CONSTRUCTION OF HOSPITALS AND HEALTH CARE FACILITIES.* * ------- * TWO -HOUR RATED FIRE BARRIER 3 5/8" (MINIMUM) METAL STUDS AT V -4" MAXIMUM O.C. (UNLESS CLOSER SPACING IS INDICATED).COMPLY WITH REQUIREMENTS OF "GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS" ABOVE. THIS FIRE BARRIER SHALL ALSO COMPLY WITH THE REQUIREMENTS OF U.L. DESIGN NUMBER U411, 2006 NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 AND 2006 IBC SECTIONS 706, 708, 712 & 713. 2007 FLORIDA EDITION OF NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 AND 2007 (W/ 2009) FBC SECTIONS 706, 708, 712 do 713. 5/8" TYPE "X" GYPSUM BOARD SHALL BE APPLIED VERTICALLY IN TWO LAYERS ON EACH SIDE. ATTACH ALL GYPSUM BOARD TO METAL STUDS WITH TYPE "S" STEEL SCREWS TO COMPLY WITH REFERENCED U.L. DESIGN NUMBER. STAGGER ALL VERTICAL FACE LAYER AND BASE LAYER JOINTS V -4" MINIMUM O.C. AND STAGGER ALL HORIZONTAL JOINTS 2' -0" MINIMUM O.C. ALL HORIZONTAL JOINTS SHALL OCCUR ABOVE THE CEILING. SEAL EACH LAYER OF GYPSUM BOARD TO FLOOR SLAB BELOW PER GENERAL NOTES 5 do 6 ABOVE. EXTEND EACH LAYER OF GYPSUM BOARD TO DECK ABOVE AND SEAL EACH LAYER OF GYPSUM BOARD TO DECK PER GENERAL NOTES 3 do 6 ABOVE. SEAL ALL PENETRATIONS PER GENERAL NOTES 4 & 6 ABOVE. USE DETAIL 1/A8.1 "PATCHING AND SEALING PENETRATIONS IN RATED FIRE BARRIERS AND /OR RATED SMOKE BARRIERS" ONLY IF PRE - APPROVED BY ALL AUTHORITIES HAVING JURISDICTION. INSTALL 3" MINIMUM SOUND ATTENUATION BLANKETS FROM FLOOR TO DECK. SEE SPECIFICATION FOR SIZE AND TYPE. COMPLY WITH GENERAL NOTE 7 ABOVE REGARDING SOUND TRANSMISSION LIMITATIONS. TWO -HOUR RATED (CMU) FIRE BARRIER �,v�� �'%M 0 8" MINIMUM WIDTH x 8" x 16" (NOMINAL) CMU. (SEE DRAWINGS FOR WIDTHS.) WITH VERTICAL � ����tiC� ONLY CLASSIFICATION D LAID OF MORTAR Ct�Ot� DETAIL 3M�E. COMPLY WITBHDT E REQUIREMENTS OF "GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS" ABOVE. 0t�,p�tt�', THIS FIRE BARRIER SHALL ALSO COMPLY WITH THE REQUIREMENTS OF U.L. DESIGN AND Co , NUMBER U905, 2006 NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 FLORIDA EDITION �T,h ,/p�3..Q�� --' 2006 IBC SECTIONS 706, 708, 712 & 713. 2007 C� G OF NFPA 101 LIFE SAFETY CODE SECTION 7.2.4.3 AND 2007 (W/ 2009) FBC -2 SECTIONS 706, 708, 712 do 713. t�.. EXTEND CMU FIRE BARRIER TO DECK ABOVE AND SEAL WITH APPROVED U.L. "HEAD -OF -WALL JOINT SYSTEM." SEAL ALL PENETRATIONS WITH APPROVED U.L. r-�- FL "THROUGH- PENETRATION FIRESTOP SYSTEM." SEE FLOOR PLANS FOR LOCATIONS WHERE FURRING IS REQUIRED. NON- -RATED PARTITION TO 4 INCHES MINIMUM ABOVE CEILING * ** 3 5/8" (MINIMUM) METAL STUDS AT V -4" MAXIMUM O.C. (UNLESS CLOSER SPACING IS INDICATED) FROM FLOOR SLAB TO DECK ABOVE. COMPLY WITH REQUIREMENTS OF "GENERAL NOTES FOR WALLS /PARTITIONS /BARRIERS" ABOVE. MINIMUM OF ONE LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE, APPLIED VERTICALLY TO 4" MINIMUM ABOVE THE CEILING. HORIZONTAL JOINTS SHALL OCCUR ABOVE THE CEILING. SEAL ALL JOINTS AND PENETRATIONS WITH FLEXIBLE SEALANT TO BE AIR -TIGHT AND SOUND- TIGHT. WHEN AN STC RATING IS REQUIRED AND /OR INDICATED TO BE USED, PROVIDE 3" MINIMUM SOUND ATTENUATION BLANKETS AND A MINIMUM OF ONE LAYER OF GYPSUM BOARD ON EACH SIDE OF THE PARTITION (UP TO DECK ABOVE), STAGGER ALL VERTICAL JOINTS 1 ` -6" MINIMUM O.C. AND STAGGER HORIZONTAL JOINTS 2' -0" O.C. MINIMUM, AND COMPLY WITH GENERAL NOTE 7 ABOVE REGARDING SOUND TRANSMISSION LIMITATIONS. WHEN SOUND ATTENUATION BLANKETS ARE INDICATED TO BE USED, BUT AN STC RATING IS NOT REQUIRED, PROVIDE A MINIMUM OF ONE LAYER OF GYPSUM BOARD ON AT LEAST ONE SIDE OF THE PARTITION (UP TO DECK ABOVE). CITY OF SOUTH MIAMI BUILDING DEPT. STRUCTURAL �:CTION #"PROVED QY. _, ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com EB #0000015 O Copyright 2009 TLC Engineering for Architecture, Inc. %0 Consultant: G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /EB0003806 IB26000797 Revisions: No. Date Description Seal LUIS CANO AR- 0015894 f •... , Project No.: 109355 Issue Date: 10/09/2009 Drawn By: Approved By. Scale: Drawing Title: MISCELLANEOUS DETAILS j Drawing No.: II. 0 2 M •rte E E T U cn co C� G (� -2 t�.. co O r-�- FL O E N CID Consultant: G R E S H A M SMITH AND P A R T N E R S 6030 Hollywood Blvd. Suite 210 Hollywood, Florida 33024 954.981.9100 FIRM'S FLORIDA CERT. NO. AAP000034 /EB0003806 IB26000797 Revisions: No. Date Description Seal LUIS CANO AR- 0015894 f •... , Project No.: 109355 Issue Date: 10/09/2009 Drawn By: Approved By. Scale: Drawing Title: MISCELLANEOUS DETAILS j Drawing No.: II.