09-979-008
il� ...E I I' �J f ffI ' IE ..... ....... i PARTIAL FIFTH FLOOR PLAN NEW CONSTRUCTION PLAN 0 5' 10' 15' 3' -6" HOLLOW METAL, 20 MIN. NO SEAM DOWN THE CENTER DOR EDGE. SEAM TO BE IN , ORNER. FRAME: WELDED METAL CLOSER: NONE SET: SCHLAGE ND96LDRHO626 -YLINDER) RAWINGS PARTIAL EIGHTH FLOOR MECHANICAL PENTHOUSE -- NEW CONSTRUCTION PLAN 0 5' 10' 15' 2 PARTIAL EIGHTH FLOOR MECHANICAL PENTHOUSE DEMOLITION PLAN 0 5' 10' 15' 01 t, �' ,I 0� 5G G 601 O^i �"* y V ELY i, GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS 201. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF DRAWINGS WHICH ALSO APPLY TO THE NEW CONSTRUCTION FLOOR PLANS: A. "GENERAL NOTES FOR DEMOLITION FLOOR PLANS" ON SHEET A2.1 202 EXISTING -TO- REMAIN WALLS /PARTITIONS /BARRIERS, DOORS, WINDOWS, PLUMBING FIXTURES, CABINETWORK /CASEWORK, EQUIPMENT, ETC., ARE "SCREENED- BACK" ON THE NEW CONSTRUCTION FLOOR PLANS, NEW CONSTRUCTION IS INDICATED BY SOLID LINES. REFER TO DEMOLITION FLOOR PLANS FOR EXTENT OF "EXISTING- TO -BE- REMOVED ". 205. REFER TO SHEETS A8.1 -A8.2 FOR TYPICAL DETAILS WHICH APPLY TO THE NEW CONSTRUCTION FLOOR PLANS, BUT WHICH MAY NOT BE SPECIFICALLY "KEYED --IN" ON THE FLOOR PLANS. 209. ALL RATED SMOKE BARRIERS, RATED HORIZONTAL EXITS AND RATED EXIT PASSAGEWAY BARRIER WALLS SHALL BE CONSTRUCTED PRIOR TO THE CONSTRUCTION OF INTERVENING WALLS *AS REQUIRED BY FLORIDA AHCA. 210. WHERE DEMOLITION OF CERTAIN ITEMS RESULTS IN UNPROTECTED OPENINGS OR PENETRATIONS IN EXISTING -TO- REMAIN FLOORS, WALLS, CEILING, ROOFS, ETC., REPAIR SUCH OPENINGS AND PENETRATIONS AS REQUIRED TO MEET ORIGINAL FIRE PROTECTION, SOUND AND STRUCTURAL REQUIREMENTS. 211. THE "LIMITS OF CONSTRUCTION" LINES SHOWN ON THE ARCHITECT'S NEW CONSTRUCTION FLOOR PLANS APPLY ONLY TO THE LIMITS OF THE ARCHITECTURAL NEW CONSTRUCTION AND RENOVATION. SEE THE OTHER DISCIPLINES' DRAWINGS FOR THE LIMITS OF THE NEW CONSTRUCTION AND RENOVATION FOR THEIR DISCIPLINE. LEGEND EXISTING TO REMAIN NEW CONSTRUCTION DEMOLITION SCOPE OF WORK EXISTING ONE -HOUR RATED FIRE BARRIER ' , . ' "IHR• ' ' • • EXISTING ONE -HOUR RATED SMOKE BARRIER m r-m MRS EXISTING TWO -HOUR RATED FIRE BARRIER�2HR EXISTING TWO -HOUR RATED (SHAFTWALL) FIRE BARRIER SFi EXISTING TWO -HOUR RATED SMOKE BARRIER rmT, r r""'r" 2HRSr -a r SEE GENERAL NOTE ON THIS SHEET 101 SEE KEYNOTE ON THIS SHEET 151 NON -RATED PARTITION TO 4" MINIMUM ABOVE CEILING ** (NO SYMBOL) ONE -HOUR RATED SMOKE BARRIER ** =■ mm MRS mm TWO -HOUR RATED FIRE BARRIER ** =■m■=x2HR =■m TWO -HOUR RATED SMOKE BARRIER ** m ■ ■ m ■ ■ 2HRS� •' EXPANSION JOINT EJ FIRE DEPARTMENT VALVE CABINET FDVC FIRE DEPARTMENT VALVE CABINET WITH FIRE EXTINGUISHER FDVC W /FE FIRE EXTINGUISHER CABINET FEC FIRE HOSE CABINET FHC FIRE HOSE CABINET WITH FIRE EXTINGUISHER FHC W /FE OWNER FURNISHED EQUIPMENT .... ..'W • V - W V NfNY ••• • •• • fi • N N • Y•f• ENGINEERING FOR ARCHITECTURE 255 S. Orange Avenue Suite 1600 Orlando, Florida 32801 PH: 407.841.9050 www.tic- engineers.com EB #0000015 © Copyright 2009 TLC Engineering for Architecture, Inc. CU m GENERAL NOTES FOR Consultant: DEMOLITION FLOOR PLANS G R E S H A M 101. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF S M I T H A N D DRAWINGS WHICH ALSO APPLY TO THE DEMOLITION FLOOR PLANS: B. "GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS" ON SHEET A2.1 p A R T N E R S 102. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS, WHICH 6030 Hollywood Blvd. WERE PROVIDED TO THE ARCHITECT /ENGINEER BY THE OWNER, AND THEY MAY NOT Suite 210 REFLECT ACTUAL FIELD CONDITIONS. PRIOR TO PROCEEDING WITH ANY WORK, THE Florida 33024 CONTRACTOR SHALL VERIFY THE ACCURACY OF THESE DRAWINGS IN COMPARISON TO Hollywood, g 5 81.910 0 EXISTING FIELD CONDITIONS AND THEN IMMEDIATELY NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS. 103. THE CONTRACTOR SHALL ALSO IMMEDIATELY NOTIFY THE ARCHITECT IF ANY FIRM'S FLORIDA DEMOLITION OR NEW CONSTRUCTION WORK ( AS INDICATED IN THE CONSTRUCTION C E R T . N 0 . DOCUMENTS) CANNOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS. AAP000034/EB0003t06 I B 2 6 0 0 0 7 9 7 104. IF ANY EXISTING FIREPROOFING AND /OR RATED ASSEMBLIES (WHICH ARE SUPPOSED TO REMAIN) ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM TO Revisions: THE ORIGINAL FIRE PROTECTION REQUIREMENTS, ALSO, THE INTEGRITY OF EXISTING RATED FLOOR, WALL, BARRIER AND ROOF ASSEMBLIES (WHICH ARE SUPPOSED TO No. Date Description REMAIN) SHALL BE MAINTAINED THROUGHOUT ALL PHASES OF CONSTRUCTION. (NOTE: AS APPLICABLE, CONTACT ARCHITECT TO VERIFY TESTED ASSEMBLIES TO BE USED FOR REPAIRS.) 105. REMOVE EXISTING CONSTRUCTION AS INDICATED. TYPICAL WALL REMOVAL SHALL INCLUDE MECHANICAL, PLUMBING, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS CONTAINED THEREIN. REMOVE DOORS, CABINETWORK, CASEWORK, WINDOWS, FRAMES, FINISHES, FIXTURES AND THEIR ATTACHMENTS AS REQUIRED. AFTER REMOVAL, REPAIR HOLES IN EXISTING -TO- REMAIN FLOORS, WALLS, BARRIERS AND ROOFS TO COMPLY WITH ORIGINAL FIRE, SMOKE AND SOUND ASSEMBLIES, FIRE PROTECTION REQUIREMENTS, AND STRUCTURAL INTEGRITY. PREPARE SURFACES TO RECEIVE NEW FINISH PER INTERIOR DESIGN DRAWINGS AND SPECIFICATIONS. (WHERE NEW FINISH IS CALLED FOR ON AN EXISTING SURFACE, REMOVE THE EXISTING FINISH AND PREPARE EXISTING SURFACE TO RECEIVE THE NEW FINISH.) 106. SEE CIVIL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS DRAWINGS FOR DEMOLITION OF UTILITIES. ' 108. AT ALL WALLS /PARTITIONS /BARRIERS, FLOORS AND ROOFS WHICH ENCLOSE OR TOUCH Seal L U I S C A N 0 SPACES WHERE WORK IS BEING PERFORMED AS A PART OF THIS PROJECT, THE A R - 0 0 l 5 8 9 4 CONTRACTOR SHALL VERIFY THAT THIS EXISTING CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, DOORS, WINDOWS, FRAMES, ETC.) MEETS THE FIRE, SMOKE AND SOUND ASSEMBLY RATINGS DESIGNATED ON THESE DRAWINGS. THE CONTRATQR SHALL 0` ALSO MAKE ANY REPAIRS AND /OR MODIFICATIONS NECESSARY TO BRING THE EXISTING -'• CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, DOORS, WINDOWS, FRAMES, = ••w, #p: ETC.) UP TO THE PROPER INDICATED FIRE, SMOKE AND SOUND ASSEMBLY RATINGS. DOORS WINDOWS AND FRAMES WHICH DO NOT MEET THE REQUIREMENTS OF THE DESIGNATED WALL /PARTITION /BARRIER ASSEMBLIES (INCLUDING PROPER LABELS) SHALL K `' BE REPLACED. THE GENERAL CONTRACTOR SHALL DESIGNATE AN ALLOWANCE FOR THIS WORK. Iv "r1A Y �.,G.. •.•.," I Y ©F SOU a H 13U1LOING 0EPT. 109. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND CT10 i ORDINANCES AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION [AHJ]. STRUCTuRkAt- S� _ 110. THE CONTRACTOR SHALL NOT CUT EXISTING OR NEW STRUCTURAL WORK IN ANY MANNER THAT MAY RESULT IN A REDUCTION OF LOAD CARRYING CAPACITY OR ___ _-Project No.: LOAD /DEFLECTION RATIO. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF �AeL0�E0t'Y' _ p 109355 STRUCTURAL CUTS PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED IN 1� ) —Issbe Date: ADVANCE FROM THE ARCHITECT AND STRUCTURAL ENGINEER. = ,- "" 10/09/2009 111. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ARCHITECT IN Drawn By: WRITING. NOTE: REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS Approved By: MATERIAL IS THE SOLE RESPONSIBILITY OF THE OWNER, AND SHALL BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. Scale: 112. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING -TO- REMAIN MATERIALS Drawing Title: AND FINISHES (CEILING GRID, CEILING TILE, GYPSUM BOARD, FINISHES, DOORS, WINDOWS, FRAMES, WALL PROTECTION, ETC.) WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION. DEMOL IT ION AND NEW CONSTRUCTION 114. THE "LIMITS OF CONSTRUCTION" LINES SHOWN ON THE ARCHITECT'S DEMOLITION FLOOR PLAN PLANS APPLY ONLY TO THE LIMITS OF THE ARCHITECTURAL DEMOLITION. SEE THE OTHER DISCIPLINES' DRAWINGS FOR THE LIMITS OF THE DEMOLITION FOR THEIR DISCIPLINE. Drawing No.: A2m2 I CL 0 M ■... E E T N U �M to co co CL co O .,C LL O E .m 0 � Q nL CU m GENERAL NOTES FOR Consultant: DEMOLITION FLOOR PLANS G R E S H A M 101. COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING NOTES IN THIS SET OF S M I T H A N D DRAWINGS WHICH ALSO APPLY TO THE DEMOLITION FLOOR PLANS: B. "GENERAL NOTES FOR NEW CONSTRUCTION FLOOR PLANS" ON SHEET A2.1 p A R T N E R S 102. THE DEMOLITION DRAWINGS HAVE BEEN DEVELOPED FROM EXISTING DRAWINGS, WHICH 6030 Hollywood Blvd. WERE PROVIDED TO THE ARCHITECT /ENGINEER BY THE OWNER, AND THEY MAY NOT Suite 210 REFLECT ACTUAL FIELD CONDITIONS. PRIOR TO PROCEEDING WITH ANY WORK, THE Florida 33024 CONTRACTOR SHALL VERIFY THE ACCURACY OF THESE DRAWINGS IN COMPARISON TO Hollywood, g 5 81.910 0 EXISTING FIELD CONDITIONS AND THEN IMMEDIATELY NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES BETWEEN THESE DRAWINGS AND ACTUAL CONDITIONS. 103. THE CONTRACTOR SHALL ALSO IMMEDIATELY NOTIFY THE ARCHITECT IF ANY FIRM'S FLORIDA DEMOLITION OR NEW CONSTRUCTION WORK ( AS INDICATED IN THE CONSTRUCTION C E R T . N 0 . DOCUMENTS) CANNOT BE PERFORMED DUE TO EXISTING FIELD CONDITIONS. AAP000034/EB0003t06 I B 2 6 0 0 0 7 9 7 104. IF ANY EXISTING FIREPROOFING AND /OR RATED ASSEMBLIES (WHICH ARE SUPPOSED TO REMAIN) ARE DAMAGED DURING DEMOLITION, THEY SHALL BE REPAIRED TO CONFORM TO Revisions: THE ORIGINAL FIRE PROTECTION REQUIREMENTS, ALSO, THE INTEGRITY OF EXISTING RATED FLOOR, WALL, BARRIER AND ROOF ASSEMBLIES (WHICH ARE SUPPOSED TO No. Date Description REMAIN) SHALL BE MAINTAINED THROUGHOUT ALL PHASES OF CONSTRUCTION. (NOTE: AS APPLICABLE, CONTACT ARCHITECT TO VERIFY TESTED ASSEMBLIES TO BE USED FOR REPAIRS.) 105. REMOVE EXISTING CONSTRUCTION AS INDICATED. TYPICAL WALL REMOVAL SHALL INCLUDE MECHANICAL, PLUMBING, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS CONTAINED THEREIN. REMOVE DOORS, CABINETWORK, CASEWORK, WINDOWS, FRAMES, FINISHES, FIXTURES AND THEIR ATTACHMENTS AS REQUIRED. AFTER REMOVAL, REPAIR HOLES IN EXISTING -TO- REMAIN FLOORS, WALLS, BARRIERS AND ROOFS TO COMPLY WITH ORIGINAL FIRE, SMOKE AND SOUND ASSEMBLIES, FIRE PROTECTION REQUIREMENTS, AND STRUCTURAL INTEGRITY. PREPARE SURFACES TO RECEIVE NEW FINISH PER INTERIOR DESIGN DRAWINGS AND SPECIFICATIONS. (WHERE NEW FINISH IS CALLED FOR ON AN EXISTING SURFACE, REMOVE THE EXISTING FINISH AND PREPARE EXISTING SURFACE TO RECEIVE THE NEW FINISH.) 106. SEE CIVIL, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, COMMUNICATIONS AND SECURITY SYSTEMS DRAWINGS FOR DEMOLITION OF UTILITIES. ' 108. AT ALL WALLS /PARTITIONS /BARRIERS, FLOORS AND ROOFS WHICH ENCLOSE OR TOUCH Seal L U I S C A N 0 SPACES WHERE WORK IS BEING PERFORMED AS A PART OF THIS PROJECT, THE A R - 0 0 l 5 8 9 4 CONTRACTOR SHALL VERIFY THAT THIS EXISTING CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, DOORS, WINDOWS, FRAMES, ETC.) MEETS THE FIRE, SMOKE AND SOUND ASSEMBLY RATINGS DESIGNATED ON THESE DRAWINGS. THE CONTRATQR SHALL 0` ALSO MAKE ANY REPAIRS AND /OR MODIFICATIONS NECESSARY TO BRING THE EXISTING -'• CONSTRUCTION (INCLUDING DAMPERS, DUCT PENETRATIONS, DOORS, WINDOWS, FRAMES, = ••w, #p: ETC.) UP TO THE PROPER INDICATED FIRE, SMOKE AND SOUND ASSEMBLY RATINGS. DOORS WINDOWS AND FRAMES WHICH DO NOT MEET THE REQUIREMENTS OF THE DESIGNATED WALL /PARTITION /BARRIER ASSEMBLIES (INCLUDING PROPER LABELS) SHALL K `' BE REPLACED. THE GENERAL CONTRACTOR SHALL DESIGNATE AN ALLOWANCE FOR THIS WORK. Iv "r1A Y �.,G.. •.•.," I Y ©F SOU a H 13U1LOING 0EPT. 109. DEMOLITION WORK SHALL BE EXECUTED IN CONFORMANCE WITH ALL CODES AND CT10 i ORDINANCES AS SET FORTH BY ALL AUTHORITIES HAVING JURISDICTION [AHJ]. STRUCTuRkAt- S� _ 110. THE CONTRACTOR SHALL NOT CUT EXISTING OR NEW STRUCTURAL WORK IN ANY MANNER THAT MAY RESULT IN A REDUCTION OF LOAD CARRYING CAPACITY OR ___ _-Project No.: LOAD /DEFLECTION RATIO. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF �AeL0�E0t'Y' _ p 109355 STRUCTURAL CUTS PRIOR TO EXECUTION SO THAT APPROVAL CAN BE OBTAINED IN 1� ) —Issbe Date: ADVANCE FROM THE ARCHITECT AND STRUCTURAL ENGINEER. = ,- "" 10/09/2009 111. WHERE EXISTING CONSTRUCTION IS FOUND TO CONTAIN ANY HAZARDOUS MATERIAL, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER AND THE ARCHITECT IN Drawn By: WRITING. NOTE: REMOVAL, DISPOSAL AND REPLACEMENT OF THE HAZARDOUS Approved By: MATERIAL IS THE SOLE RESPONSIBILITY OF THE OWNER, AND SHALL BE IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. Scale: 112. THE CONTRACTOR SHALL REPLACE OR REPAIR ANY EXISTING -TO- REMAIN MATERIALS Drawing Title: AND FINISHES (CEILING GRID, CEILING TILE, GYPSUM BOARD, FINISHES, DOORS, WINDOWS, FRAMES, WALL PROTECTION, ETC.) WHICH ARE DAMAGED DURING DEMOLITION OR CONSTRUCTION. DEMOL IT ION AND NEW CONSTRUCTION 114. THE "LIMITS OF CONSTRUCTION" LINES SHOWN ON THE ARCHITECT'S DEMOLITION FLOOR PLAN PLANS APPLY ONLY TO THE LIMITS OF THE ARCHITECTURAL DEMOLITION. SEE THE OTHER DISCIPLINES' DRAWINGS FOR THE LIMITS OF THE DEMOLITION FOR THEIR DISCIPLINE. Drawing No.: A2m2 I