Loading...
09-979-001i 4 4 PLAN REVIEW DATA BUILDING INFORMATION: BUILDING CLASS IF ICAT ION: CONSTRUCTION TYPE: TYPE I- SPRINKLERED NFPA 220: 1 YPE 11 OCCUPANCY TYPE: GROUP 12 (EXISTING TO REMAIN) GOVERNING CODES AND REGULATIONS: f I \ All k1 I October 9, 2009 ATS REPLACEMENT Ilk Miami, Florida FLORIDA BUILDING CODES: FLORIDA BUILDING CODE (2007 with 2009 SUPPLEMENTS) INCLUDING: FLORIDA ACCESSIBILITY CODE FLORIDA ENERGY CODE FBC TEST PROTOCOLS FOR HIGH VELOCITY HURRICANE ZONES (2007 with 2009 SUPPLEMENT) FBC MECHANICAL CODE (2007 with 2009 SUPPLEMENT) FBC PLUMBING CODE (2007 with 2009 SUPPLEMENTS) FBC FUEL GAS CODE (2007 with 2009 SUPPLEMENTS) FLORIDA ADMINISTRATIVE CODES (INCLUDING LIFE SAFETY CODE): Chapter 694- 3.012: Standards of the National Fire Protection Association and Other Standards Adopted Florida Fire Prevention Code (2007) which includes: Florida Statutes, Chapter 633: Fire Prevention and Control Florida Administrative Code, Chapter 69A Florida Administrative Code, Chapter 69A -60: Florida Fire Prevention Code NFPA 1, Uniform Fire Code (2006 Florida Edition) NFPA 101, Life Safety Code (2006 Florida Edition) NATIONAL F IRE PROTECTION ASSOCIATION (NFPA) CODES: SEE THE LIST OF APPLICABLE NFPA CODES (AND THE EDITION OF EACH) IN SPECIFICATION SECTION 014113 - "CODES AND STANDARDS" IN THE PROJECT MANUAL FEDERAL CODES AND REGULATIONS: THE AMERICANS WITH DISABILITIES ACT [ADA] AND ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (1991) AR11111ij (it) S P i TA L GS &P No. 27457.00 P R 0 J E C T N F 0 R M A T 1 0 N GRAPHIC SYMBOLS LEGEND GENERAL NOTES 001. THE CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF THE DRAWINGS AND SPEC IF ICAT IONS, SCHEDULES, ETC. THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THESE DRAWINGS AND THE SPECIFICATIONS HEREIN; AND HE SHALL �- INDICATES DETAIL OR IMMEDIATELY NOTIFY THE ARCHITECT OF ANY INCONSISTENCIES THAT HE DISCOVERS, 2 SECTION NUMBER 002. THE CONTRACTOR SHALL PROVIDE CHASES FOR MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, COMMUN ICAT IONS, A3'z,"7-_ INDICATES SHEET ETC., AS REQUIRED AND AS NECESSARY. SEE RESPECTIVE DISCIPLINES' DRAWINGS. ON WHICH DETAIL OR 003. PIPING LOCATED ABOVE GRADE AND INSIDE THE BUILDING SHALL BE CONCEALED IN FURRED SPACES. THE CONTRACTOR SHALL SECTION IS SHOWN COORDINATE WITH OTHER TRADES TO PROVIDE FURRING FOR PIPING INSTALLED IN FINISHED AREAS. THE CONTRACTOR SHALL GAIN APPROVAL FROM THE ARCHITECT IN ADVANCF,PRIOR TO LOCATING AND /OR PROVIDING ANY "FURRED SPACES" WHICH ARE 5- - INDICATES DETAIL OR NOT SPECIFICALLY INDICATED ON THE FLOOR PLANS. Aq.l ENLARGED PLAN NUMBER 004. PROVIDE METAL STUD FRAMING AROUND ALL PENETRATIONS THRU METAL STUD /GYPSUM BOARD WALLS. INDICATES SHEET 005. PROVIDE CONTINUOUS SEALANT TO PROVIDE "WATER TIGHT" AND "AIR TIGHT" CONDITION AT THE PERIMETERS OF ALL ON WHICH DETAIL OR ENLARGED PLAN DOOR FRAMES, INTERIOR WINDOW FRAMES, EXTERIOR WINDOW FRAMES, W INDOW STOOLS, CABINETS, CASEWORK, COUNTERTOPS, IS SHOWN TOILET ACCESSORIES (BOTH RECESSED & SURFACE MOUNTED), F IRE EXTINGUISHER CAB INETS, F IRE DEPARTMENT VALVE CABINETS, ETC. (EVEN WHEN THE JO INT AT THE PERIMETER IS E ITHER H IDDEN OR NOT READ ILY V IS iBLE). 006. EQUIPMENT INDICATED WITH DASHED LINES SHALL BE FURNISHED BY THE OWNER AND RECEIVED / STORED BY THE GENERAL 5 _ CONTRACTOR. (SEE OWNER FURNISHED EQUIPMENT MANUAL AND OWNER FURNISHED VENDOR DRAWINGS.) THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR THE DELIVERY AND INSTALLATION OF ALL OWNER FURNISHED EQUIPMENT. ��- COLUMN 007. THE CONTRACTOR SHALL VERIFY THAT EXIT EGRESS IS MAINTAINED FOR ALL OCCUPIED AREAS OF THE BUILDING THROUGHOUT REFERENCE ALL PHASES OF CONSTRUCTION. ALL EXISTING STAIRWAYS AND RATED EXIT PASSAGEWAYS SHALL BE MAINTAINED SO THAT GRID REVISION 5 THEY ARE CLEAR AND ACCESSIBLE:AND THE INTEGRITY OF THE DESIGNATED RATED ENCLOSURE AROUND THEM SHALL ALSO BE MAINTAINED THROUGHOUT ALL PHASES OF CONSTRUCTION. 008. THE EXISTING BUILDING ENVELOPE SHALL BE MAINTAINED SO AS TO PROVIDE A WATERTIGHT, WEATHERT IGHT AND CONDITIONED EXISTING SPACE AT ALL TIMES THROUGHOUT ALL PHASES OF CONSTRUCTION. PROVIDE TEMPORARY ENCLOSURES AS REQUIRED. DESIGN T E A M PROVIDE PORTABLE HEAT ING UNITS AND /OR COOLING UNITS TO MAINTAIN 70 DEGREES F. (INSIDE INS IDE TEMPERATURE) IN OCCUPIED SPACES,UNLESS OTHERWISE DIRECTED BY THE OWNER. Architects: Gresham, Smith & Partners 009. DO NOT EMBED CONDUIT INTO ANY ELEVATED COMPOSITE SLAB. ALSO, DO NOT RECESS OR EMBED CONDUIT, PIPING, BACKBOXES 6030 Hollywood Boulevard OR ANYTHING ELSE (THAT COULD ADVERSELY AFFECT EITHER THE STRUCTURAL INTEGRITY OR THE FIRE RATED INTEGRITY OF THE Suite 210 ELEVATED SLAB) INTO ANY TYPE OF ELEVATED SLAB. Hollywood, Florida 33024 010. THE CONTRACTOR SHALL BF RESPONSIBLE FOR COORDINATING AND VERIFYING DIRECTLY WITH THE OWNER REGARDING ANY (954) 911 -9100 OWNER DESIRED CHANGES TO THE NUMBERING SYSTEM AND /OR NAMING CONVENTION FOR INDIVIDUAL SPACES,FLOOR LEVELS, ELEVATORS, STA IRS, ETC. IN THE PROJECT. THESE MUST BE VER IF ED PR IOR TO THE LABEL ING OF, OR IDENT IF ICAT ION OF, ANY P. I. C. Luis Cano OF THESE ITEMS / SPACES IN (OR ON) ELECTR ICAL PANELS, MECHAN ICAL EQU IPMENT, F IRE ALARM SYSTEMS, F IRE ALARM PANELS, ELEVATORS, S IGNAGE, COMMUN ICAT ION SYSTEMS, SECUR ITY SYSTEMS, ETC. P.M. /P.A. ]Luis Cano INDEX '20rig G S R P G P C Kristin Herman E P. T. Tamika Jones H A Mechanical, TLC ENGINEERING FOR ARCHITECTURE Plumbing, Fire 255 S. ORANGE AVENUE Protection and Suite 1600 Elec. Engineers: ORLANDO, FLOR IDA 32101 P (407) 841 - 9050 R MECH, N E R Don Bailey • P. E. U • Y Y F. P. Don Bailey AL2.5 FIFT FLOOR — OVERALL LIFE SAFETY PLAN P. E. ELEC. James Ferris AL2.8A P. E. INDEX '20rig G S R P G R E S H A M S M I T H 10/0009 A N D P A R T N E R S vry ,.. V• FILE NAME IPARM YuVUU YW• Y.. •r LATEST REV. DATE 1�0 •4 • • i N/A. 10/0009 AL2.1A • • Y Y V Y ••Y•U U • • • U U • Y Y AL2.5 FIFT FLOOR — OVERALL LIFE SAFETY PLAN 7164AL205.dgn AL2.8A ROOF PENTHOUSE — PARTIAL LIFE SAFETY PLAN 7164AL208A.dgn Y Y r Y 4 •• • 4 • u Y ^2.2 • • W Y • 4 • Y W A8.1 A8.2 MISCELLANEOUS DETAILS MISCELLANEOUS DETAILS 7164A801.dgn 7164A802.dgn N/A N/A •••• r•YiY •U• •••• 7164ABO3.dgn N A • • Y • r • I• E000 ELECTRICAL LEGEND AND NOTES • U N/A • • ELECTRICAL ONE — LINE DIAGRAM N/A N A ENGINEERING FOR ARCHITECTURE SHEET NUMBER SHEET TITLE FILE NAME IPARM RELEASE DATE I FOR CONST. REVISION NUMBER(S) LATEST REV. DATE COVER COVER SHEET 7457acov.dgn N/A. 10/0009 AL2.1A FIRST FLOOR PART A — PARTIAL LIFE SAFETY PLAN 7164AL201A.dgn N/A AL2.1 B FIRST FLOOR PART B — PARTIAL LIFE SAFETY PLAN 7164AL201 B.dg N A AL2.5 FIFT FLOOR — OVERALL LIFE SAFETY PLAN 7164AL205.dgn AL2.8A ROOF PENTHOUSE — PARTIAL LIFE SAFETY PLAN 7164AL208A.dgn A2.1 DEMOLITION AND NEW CONSTRUCTION PLAN 7164A201.dgn ^2.2 DEMOLITION AND NEW CONSTRUCTION PLAN 7164A202,dgn N A A8.1 A8.2 MISCELLANEOUS DETAILS MISCELLANEOUS DETAILS 7164A801.dgn 7164A802.dgn N/A N/A A8.3 MISCELLANEOUS DETAILS 7164ABO3.dgn N A E000 ELECTRICAL LEGEND AND NOTES N/A N/A E001 ELECTRICAL ONE — LINE DIAGRAM N/A N A E002 E003 ELECTRICAL ONE — LINE DIAGRAM ELECTRICAL ONE — LINE DIAGRAM N A N A N A N A E201 ELECTRICAL DEMOLITION — POWER N/A N/A E301 PARTIAL FIRST FLOOR PLAN — POWER N/A E302 EIGHTH FLOOR MECHANICAL PENTHOUSE N/A N/A E601 E602 E801 ENLARGED ELECTRICAL ROOMS — CEP ENLARGED ELECTRICAL ROOMS — NORTH TOWER PANEL SCHEDULES N/A N/A N/A N/A N/A N/A E802 PANEL SCHEDULES N/A N/A E803 ELECTRICAL DETAILS N/A N/A M001 HVAC LEGEND, GENERAL NOTES do SHEET N/A N A M201 M202 PARTIAL FIRST FLOOR PLAN — HVAC PARTIAL ROOF PLAN — HVAC N/A N/A N A N/A M301 HVAC DETAILS N/A N A M302 HVAC SCHEDULES N/A N/A FPO01 FIRE PROTECTION LEGEND N/A N A FP 100 FLOOR PLAN — FIRE PROTECTION _ N/A N/A CITY OF SOUT'Ii N11AMI BUILDING DEi :,,r. STRUCTUi?A1 SECTION APPROVED BY: tt) i z" aj 6b. X� ter r(� \•�" , + �r l�: