09-963-006a
0
H
O
J
a
ELECTRICAL ABBREVIATIONS ':
AFC
ELECTRICAL SYMBOLS
N
NEW DEVICE
AFF
ABOVE FINISHED FLOOR
NC (N.C.)
NORMALLY CLOSED
GENERAL NOTES:
AUTOMATIC TRANSFER SWITCH
ALL SYMBOLS SHOWN MAY NOT APPEAR
IN ALL DRAWINGS. SYMBOLS
ARE SHOWN SCHEMATIC
AND MAY NOT BE TO SCALE.
TE LE P H 0 N E DATA
A.
KAIC RATINGS SHALL MATCH LOWEST RATED DEVICE FOR NEW CIRCUIT BREAKERS TO BE INSTALLED
LIGHTING
BOTTOM OF FIXTURE
NIC
NOTIN CONTRACT
C
CONDUIT
NL
IN THE EXISTING PANELBOARDS.
CB,C/B OR
CIRCUIT BREAKER
NO (N.O.)
SYMBOL
DESCRIPTION
DEVICE MTG. HT.
SYMBOL
DESCRIPTION
DEVICE MTG. HT. B.
NOT USED.
W
CKT. ELSEWHERE ON THE PLAN
CKT
CIRCUIT
4' SQUARE BOX WITH SINGLE GANG ADAPTER FOR TELEPHONE OUTLETS. STUB
C.
CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF LIGHT
'c �
PB
PULL BOX
SEE FIXTURE
O
O
2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON NORMAL CIRCUIT.
SCHEDULE
AXT
3/4" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. "X" DENOTES QUATITY OF
TELEPHONE (T) OUTLETS.
18" AFF
D.
FIXTURES AND ALL CEILING MOUNTED DEVICES.
CONTRACTOR SHALL PROVIDE AND INSTALL AN IDENTIFICATION NAMEPLATE FOR EACH ELECTRICAL
7711
2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON CRITICAL CIRCUIT.
SEE FIXTURE
PWR
POWER
SCHEDULE
CABINET HEATER
EQUIPMENT /APPURTENANCE DEPICTING THE DESIGNATION INDICATED ON THE DRAWINGS.
R
RELOCATED DEVICE
DFA
0
2'x2' / 2'x4' FLUORESCENT LIGHT FIXTURE ON LIFE SAFETY CIRCUIT.
SEE FIXTURE
SCHEDULE
4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR DATA OUTLET. STUB 3/4" C.
RECEPTACLE(S)
EC
EMPTY CONDUIT
10D
ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. "X" DENOTES QUANTITY OF DATA
t8' AFF E.
ALL EMPTY CONDUIT SYSTEMS SHALL CONTAIN A PULL WIRE FOR FUTURE PULLING OF CONDUCTORS.
ELECTRIC
2'x4' FLUORESCENT LIGHT FIXTURE W/INBOARD LAMPS ON CRITICAL
SEE FIXTURE
p
CIRCUIT AND OUTBOARD LAMPS ON NORMAL CIRCUIT.
SCHEDULE
EMERGENCY — RED
(D), PACS (P), OR PATIENT MONITOR (PM) OUTLETS.
F.
CONTRACTOR SHALL COORDINATE ALL REQUIRED ENERGY MANAGEMENT SYSTEM POINTS AND CONTACT
CONNECTIONS TO ENSURE THE COMPLETE AND PROPER OPERATION OF ALL SYSTEMS.
.=ir=
WALL MOUNTED FIXTURE ON NORMAL CIRCUIT.
SEE FIXTURE
v
ENERGY MANAGEMENT SYSTEM
SCHEDULE
4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR TELEPHONE OUTLETS AND DATA
18" AFF G.
CONTRACTOR SHALL PROVIDE AND INSTALL A 1" CONDUIT W /PULL WIRE FROM EACH WALL MOUNTED
SUPPLY AIR FAN
EP
SEE FIXTURE
WALL MOUNTED FIXTURE ON CRITICAL CIRCUIT.
SCHEDULE
'4XD/XT
OUTLET. STUB 3/4" C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX. "X"
DENOTES QUANTITY OF DATA (D), TELEPHONE (T), OR PACS (P) OUTLETS.
SPACE ONLY
TELEPHONE AND /OR DATA OUTLET STUB UP fi" ABOVE FINISHED CEILING.
ELECTRIC WATER COOLER
SEE FIXTURE
c3r� i
WALL MOUNTED FIXTURE ON LIFE SAFETY CIRCUIT.
SCHEDULE
SPARE
EX
H.
THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES ALL NECESSARY WIRING AND
CONNECTIONS REQUIRED PRIOR TO PULLING CONDUCTORS INTO NEW CONDUITS.
SEE FIXTURE
Q
RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON NORMAL CIRCUIT.
SCHEDULE
FUSE
4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR ONE WALL MOUNTED
SW
SWITCH
♦w
TELEPHONE OUTLET. STUB 3/4- C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX.
48" '� I.
CONTRACTOR SHALL PROVIDE ALL EQUIPMENT AND MATERIAL NECESSARY FOR A COMPLETE AND
SEE FIXTURE
®
RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON CRITICAL CIRCUIT.
SCHEDULE
4" SQUARE BOX WITH SINGLE GANG ADAPTER FOR PATIENT MONITOR OUTLET FOR
TELEMETRY SYSTEM - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX.
"
60 J.
OPERATIONAL INSTALLATION.
CONTRACTOR SHALL NOT DISRUPT SERVICE TO ELECTRICAL APPURTENANCES TO REMAIN.
TEL
RECESSED /SUSPENDED DOWNLIGHT FIXTURE ON LIFE SAFETY CIRCUIT.
SEE FIXTURE
FAN COIL UNIT
EDUILE
QV
4" SQUARE BOX WITH SINGLE GANG ADAPTER (UNO) FOR VENDOR SUPPLIED CABLE AND
18. K.
CONTRACTOR SHALL CONNECT ALL NEW FIRE ALARM DEVICES, AS INDICATED ON DRAWINGS, TO
FIXT
FIXTURE
SEE
0
RECESSED DOWNLIGHT FIXTURE WITH WALL WASH TRIM.
SCHEDULE
TP
OUTLET - STUB 3/4 C. ABOVE ACCESSIBLE CEILING FROM OUTLET BOX.
STACKED DATA OUTLET BOXES OR THE LIKE THAT SHARE 3/4" C. STUB UP.
18" AFF
EXISTING SYSTEM. CONTRACTOR SHALL PROVIDE NEW EXPANDABLE MODULES, CARDS, ETC. AS
REQUIRED TO EXISTING SYSTEM IN ORDER TO ACCOMODATE NEW DEVICES.
'
e Fo x
CEILING OR WALL MOUNTED EXIT SIGN. SHADING INDICATES DOUBLE OR
SEE FIXTURE
SINGAL FACE ARROWS INDICATE CHEVRON DIRECTIONS.
SCHEDULE
®
FLOOR MOUNTED BOX FOR TWO TELEPHONE OUTLETS. STUB 3/4" C. UNDER FLOOR
TO ABOVE ACCESSIBLE CEILING.
30" AFF L,
FLUSH
M.
ALL PANELBOARDS SERVING THE AREA OF WORK SHALL BE BONDED TOGETHER IN COMPLIANCE WITH
THE NEC.
CONTRACTOR SHALL PROVIDE EQUIPOTENTIAL TEST FOR ALL ELECTRICAL DEVICES AND EQUIPMENT
U
WALL MOUNTED 90- MINUTE BATTERY - POWERED EGRESS LIGHTING.
SCHEDULE FIXTURE
4�
EXTERIOR POLE MOUNTED AREA LUMINAIRE. ARROW INDICATES DIRECTION OF
SEE FIXTURE
PHOTOMETRIC OPTIC ROTATION.
SCHEDULE
®
FLOOR MOUNTED BOX FOR TWO TELEPHONE OUTLETS. STUB 3/4" C. UNDER FLOOR
TO ABOVE ACCESSIBLE CEILING.
FLUSH
WITHIN THE AREA OF WORK.
FAN TERMINAL UNIT
SEE FIXTURE
��
TRACK LIGHTING
SCHEDULE
UNIT HEATER
FLOOR MOUNTED BOX FOR ONE DATA OUTLET. STUB 3/4" C. UNDER FLOOR TO
FLUSH N.
ALL RECEPTACLES AND SWITCH PLATES SHALL HAVE ENGRAVED COVER PLATES TO INDICATE THE
UNLESS NOTED OR INDICATED OTHERWISE
GEF
GENERAL EXHAUST FAN
SWITCHES
V
VOLTAGE
GEN
®
ABOVE ACCESSIBLE CEILING.
PANEL BOARD AND CIRCUIT NUMBERS POWERING THE DEVICE.
VP
VAPOR PROOF
GFCI, GFl
GROUND FAULT CIRCUIT INTERRUPTER
®
FLOOR MOUNTED BOX FOR TWO TELEPHONE OUTLETS AND ONE DATA OUTLET.
STUB 3/4" C. UNDER FLOOR TO ABOVE ACCESSIBLE CEILING.
FLUSH 0.
ALL EMERGENCY RECEPTACLES, LIGHT SWITCHES, AND RESPECTIVE COVER PLATES SHALL BE RED.
VARIABLE VOLUME UNIT
HP
HORSE POWER
SYMBOL
DESCRIPTION
DEVICE MTG. HT.
®
FLOOR MOUNTED BOX FOR TWO TELEPHONE OUTLETS AND TWO DATA OUTLETS.
STUB 3/4 C. UNDER FLOOR TO ABOVE ACCESSIBLE CEILING.
"X"
FLUSH P.
THE ELECTRICAL CONTRACTOR SHALL VERIFY THAT THE AIC RATING OF ALL EXISTING CIRCUIT
BREAKERS IN PANELS AFFECTED BY THIS PROJECT ARE ABOVE THE FAULT CURRENT VALUES
HIGH VOLTAGE
WALL SWITCH SPST, 204, 120/277V
48" AFF
W/
WITH
HWAT
®X
FLOOR MOUNTED BOX FOR DATA OUTLET(S). INDICATES THE NUMBER OF OUTLETS
F
CEILING
FLUSH
PROVIDED IN THE SHORT CIRCUIT CALCULATIONS. IF THE AIC RATINGS ARE BELOW THE FAULT
WG
WIRE GUARD
$2
DOUBLE POLE TOGGLE SWITCH, 20A/120/277V
48 " AFF
AND CABLES STUB C. UNDER FLOOR TO ABOVE ACCESSIBLE .
.
CURRENT VALUES, THE ELECTRICAL CONTRACTOR SHALL REPLACE ALL BREAKERS WITH NEW
WEATHER PROOF
ICAND
INCANDESCENT
�}
CEILING MOUNTED BOX FOR TWO TELEPHONE OUTLETS. STUB 3/4" C. ABOVE
FLUSH
BREAKERS WITH AIC RATINGS ABOVE THE FAULT CURRENT VALUES.
WT
WATER TIGHT
IG
$3
3 -WAY WAIL SWITCH, 20A, 120/277V
48" AFF
Y '
ACCESSIBLE CEILING.
XFMR
TRANSFORMER
JB
JUNCTION BOX
CEILING MOUNTED BOX FOR ONE DATA OUTLET. STUB 3/4" C. ABOVE ACCESSIBLE
CEILING.
CEILING MOUNTED BOX FOR TWO TELEPHONE OUTLETS AND ONE DATA OUTLET.
Q.
FLUSH
FLUSH R.
CONTRACTOR SHALL UPDATE ALL ELECTRICAL PANEL SCHEDULES AFFECTED BY THIS PROJECT.
HAND WRITTEN SCHEDULES ARE NOT ACCEPTED. SCHEDULES SHALL BE TYPED OR COMPUTER
GENERATED.
IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO CONNECT ANY NEW FIRE /SMOKE
$4
4 -WAY WALL SWITCH, 20A, 120/277V
48" AFF
$n
WALL BOX DIMMER SWITCH
48" AFF
LIGHTING
LTS
STUB 3/4" C. ABOVE ACCESSIBLE CEILING.
DAMPERS TO THE EXISTING FIRE ALARM SYSTEM. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT
LV
KEY OPERATED WALL SWITCH
48' AFF
K
MAN
MASTER ANTENNA
CEILING MOUNTED BOX FOR TWO TELEPHONE OUTLETS AND TWO DATA OUTLETS.
STUB 3/4" C. ABOVE ACCESSIBLE CEILING.
FLUSH
AND MATERIAL NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO
MECHANICAL DRAWINGS FOR EXACT LOCATION OF FIRE SMOKE DAMPERS.
�T
WALL SWITCH WITH ADJUSTABLE COUNTDOWN TIMER
48" AFF
MOTOR CONTROL CENTER
MDP
CEILING MOUNTED BOX FOR DATA OUTLET(S). "X" INDICATES THE NUMBER OF
FLUSH S.
CONTRACTOR SHALL PATCH /RESTORE ALL WALL /FLOOR PENETRATIONS AS REQUIRED TO
MH
MANHOLE
$3D
3 -WAY WAIL DIMMER SWITCH, 20A, 120/277v
48" AFF
YX
OUTLETS AND CABLES. STUB 3/4" C. ABOVE ACCESSIBLE CEILING.
CEILING MOUNTED BOX FOR PATIENT MONITORING OUTLET FOR TELEMETRY SYSTEM.
STUB 3/4" C. ABOVE ACCESSIBLE CEILING.
FLUSH T.
MAINTAIN /RESTORE ORIGINAL FIRE RATING.
IT IS THE RESPONSIBILITY OF MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION
CONTRACTORS TO VISIT THE SITE AND EXAMINE IN DETAIL THE SCOPE OF WORK OF THIS PROJECT
$3K
3 -WAY, KEY OPERATED WALL SWITCH, 20A, 120/277V
48" AFF
me
MOMENTARY WALL SWITCH, 204, 120/277V
48" AFF
PRIOR TO BID AND SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER IF A CONDITION EXISTS WHICH
PREVENTS HIM /HER FROM ACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS,
$LV
LOW VOLTAGE WALL SWITCH
48" AFF
SO NO ADDITIONAL COST IS INCURRED BY THE OWNER. AFTER CONTRACT IS AWARDED IT WILL BE
ASSUMED THAT THE SITE WAS VISITED AND EXAMINED AND ALL PARTIES ARE IN AGREEMENT WITH THE
$as
WALL MOUNTED OCCUPANCY SENSOR SWITCH
48" AFF
SCOPE OF THE WORK.
WIRING DEVICES & POWER
SYMBOL
DESCRIPTION
DEVICE MTG. HT.
G_
SINGLE RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R
18" AFF U.N.O.
&
DUPLEX RECEPTACLE - 20A/125V/2P/3W/G NEMA 5 -20R
18" AFF U.N.O.
@
DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5 -20R
COUNTERTOP
6" ABO U N.o
DUPLEX RECEPTACLE GA - 20A/125V/2P/3W/G NEMA 5 -20R
18" AFF U.N.O.
DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5 -20R
6" ABOVE COUNTERTOP
U.N.O.
QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE
18" AFF U.N.O.
COVERPLATE
QUADRAPLEX RECEPTACLE TWO DUPLEX RCPTS. UNDER ONE
6" ABOVE COUNTERTOP
COVERPLATE
U.N.O.
�iiGFI
uWITH
DUPLEX RECEPTACLE GA - 20A/125V/2P/3W/G NEMA 5 -20R
18" AFF U.N.O.
WEATHERPROOF ENCLOSURE
t,o,l;FI
DUPLEX RECEPTACLE GFl - 20A/125V/2P/3W/G NEMA 5-20R
18" AFF U.N.O.
�°yyyy�P
WITH WEATHERPROOF ENCLOSURE - ROOF MOUNTED
0
DUPLEX RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R
FLOOR MOUNTED - FLUSH MOUNTED UNO
DUPLEX RECEPTACLE - 20A/125V/2P/3W/G NEMA 5-20R
_
CEILING MOUNTED - FLUSH MOUNTED UNO
®
SPECIAL PURPOSE RECEPTACLE (NEMA NO. AS INDICATED)
18" AFF U.N.O.
Q F-Q
JUNCTION BOX - SIZE AND MOUNTING AS REQUIRED
-
39==MCT
MULTIOUTLET ASSEMBLY - LENGTH AND OUTLET SPACING AS INDICATED
-
_J
PANELBOARD - SURFACE MOUNTED
72" TO TOP
IPP'7
PANELBOARD - FLUSH MOUNTED
72" TO TOP
r--I 30/3
CIRCUIT BREAKER DISCONNECT SWITCH - THERMAL MAGNETIC
+54" U.N.O.
CB IN NEMA 1 ENCLOSURE U.N.O.• AMPS /POLES AS INDICATED
DISCONNECTNSWIITCHH - 30/3 N #/1. INDICATES 3 A H POLE,
+54" U.N.O.
30/3/ * /1
TYPE, F
®2
MOTOR STARTER FVNR UNO; NUMBER INDICATES NEMA SIZE
AS REQUIRED
CB
COMBINATION MOTOR CONTROLLER/DISCONNECT SWITCH
AS REQUIRED
MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOAD AND PILOT
AS REQUIRED
LIGHT
MOTOR- NUMBER INSIDE SYMBOL INDICATES HORSEPOWER. REFER TO
_
MOTOR FEEDER SCHEDULES FOR FEEDER INFORMATION
TAG
EMERGENCY POWER OFF BUTTON. WALL MOUNTED - STUB 3/4m C.
AFF
ABOVE ACCESSIBLE CEILING FROM OUTLET BOX
X,X,X
THREE SINGLE POLE DEVICE CIRCUIT NUMBERS
-
X /X /X
MULTI -POLE DEVICE CIRCUIT NUMBERS
-
HOMERUN CONDUIT MINIMUM 4" U.N.O. (NUMBER OF ARROWHEADS
INDICATE QUANTITY OF #12 PHASE CONDUCTORS). PROVIDE ONE #12
_
GROUND AND ONE X112 NEUTRAL IN EACH CONDUIT U.N.O. MAXIMUM OF
THREE PHASE CONDUCTORS PER HOMERUN CONDUIT.
a
0
H
O
J
a
ELECTRICAL ABBREVIATIONS ':
AFC
ABOVE FINISHED COUNTER
N
NEW DEVICE
AFF
ABOVE FINISHED FLOOR
NC (N.C.)
NORMALLY CLOSED
ATS
AUTOMATIC TRANSFER SWITCH
NEC
NATIONAL ELECTRIC CODE
BFC
BELOW FINISHED CEILING
NF
NONFUSED
BOF
BOTTOM OF FIXTURE
NIC
NOTIN CONTRACT
C
CONDUIT
NL
NIGHT LIGHT
CB,C/B OR
CIRCUIT BREAKER
NO (N.O.)
NORMALLY OPEN
CKT BKR
E Lo
(ON)
HOME RUN FOR CKT IS "ON" THE SAME
c�Un�>
�
W
CKT. ELSEWHERE ON THE PLAN
CKT
CIRCUIT
° °w
x Q-
W
'c �
PB
PULL BOX
CCTV
CLOSED CIRCUIT T.V.
0 0--
PNL
PANEL
CLG
CEILING
Q
PWR
POWER
CUH
CABINET HEATER
R
RELOCATED DEVICE
DFA
DOWN FROM ABOVE
RCPT(S) OR
RECEPTACLE(S)
EC
EMPTY CONDUIT
RECEPT
ELEC
ELECTRIC
RF
RETURN AIR FAN
E
EMERGENCY — RED
SEF
SMOKE EXHAUST FAN
EMS
ENERGY MANAGEMENT SYSTEM
SF
SUPPLY AIR FAN
EP
EXPLOSION PROOF
SO (S.O.)
SPACE ONLY
EWC
ELECTRIC WATER COOLER
SP
SPARE
EX
EXISTING
ST (S.T.)
SHUNT TRIP
F
FUSE
SW
SWITCH
FA
FIRE ALARM
TC
TIME CLOCK
FACP, FAP
FIRE ALARM CONTROL PANEL
TEL
TELEPHONE
FCU
FAN COIL UNIT
TF
TRANSFER FAN
FIXT
FIXTURE
TP
TAMPER PROOF
FLR
FLOOR
TV
TELEVISION
FLUOR
FLUORESCENT
OF
UNDERFLOOR
FTP, FTS
FAN TERMINAL UNIT
UG
UNDERGROUND
FTU
FAN TERMINAL UNIT
G, GND
GROUND (EQUIPMENT)
UH
UNIT HEATER
UNO (U.N.O.)
UNLESS NOTED OR INDICATED OTHERWISE
GEF
GENERAL EXHAUST FAN
V
VOLTAGE
GEN
GENERATOR
VP
VAPOR PROOF
GFCI, GFl
GROUND FAULT CIRCUIT INTERRUPTER
VV
VARIABLE VOLUME UNIT
HP
HORSE POWER
W
WIRE
HV
HIGH VOLTAGE
W/
WITH
HWAT
HEAT TRACE
WG
WIRE GUARD
IC
INTERRUPTING CAPACITY
WP
WEATHER PROOF
ICAND
INCANDESCENT
WT
WATER TIGHT
IG
ISOLATED GROUND
XFMR
TRANSFORMER
JB
JUNCTION BOX
+xx
MOUNTING HEIGHT IN INCHES. AFF UNO.
KEF
KITCHEN EXHAUST FAN
LTG
LIGHTING
LTS
LIGHTS
LV
LOW VOLTAGE
MAN
MASTER ANTENNA
MCB
MAIN CIRCUIT BREAKER
MCC
MOTOR CONTROL CENTER
MDP
MAIN DISTRIBUTION PANEL
MH
MANHOLE
MLO
MAIN LUGS ONLY
MID
MOUNT OR MOUNTED
NOTES:
1. 48" AFF INDICATES TO TOP OF DEVICE;
18" AFF INDICATES TO BOTTOM OF DEVICE;
80" AFF INDICATES TO BOTTOM OF DEVICE;
ALL OTHER MOUNTING HEIGHTS REFER TO CENTERLINE OF DEVICE.
MISCELLANEOUS
Q2 — NOTES: DENOTES "SEE NOTE NO. 2"
�— MARK (ID) NUMBER FOR EQUIPMENT
REF. 2/E2.02 — DENOTES: REFERENCE DETAIL 2 IN DRAWING (SHEET) E2.02
XX —XX PANEL AND CIRCUIT NOTE: THIS INFORMATION MAY NOT
ALWAYS BE INDICATED IN THE FORMAT
p a -. - SWITCHING DESIGNATION SHOWN, DUE TO SPACE RESTRICTIONS IN
X -+--- FIXTURE TYPE THE FLOOR PLAN.
ELECTRICAL SHEET LIST
DWG No.
DRAWING TITLE
SCALE
EO.00
GENERAL INFORMATION — ELECTRICAL
NTS
EO.OI
PARTIAL REFERENCE LOCATION PLAN
VARIES
E1.00
PARTIAL FIFTH FLOOR PLANS — ELECTRICAL
1/4" = 1' —O"
E2.00
PARTIAL ELECTRICAL DISTRIBUTION DIAGRAM
NTS
E3.00
ELECTRICAL SCHEDULES AND STUDIES
NTS
E4.00
ELECTRICAL SPECIFICATIONS
NTS
° °
v
C �
° (5
..
o
v
Z -0-0000
-
E Lo
N 0 0 X
O o
}o
c�Un�>
�
W
> U U �
O=
.�? °
° °w
x Q-
W
'c �
N U
O U
0 0--
;✓
0
�
cy)
Fm
v
IL
cl)
J
V)
0
a� U
CO
�o
�
O r2 .-
Z
V
C"
�
L0�% I
L6 �
C oD °
° °
v
C �
° (5
..
o
v
Z -0-0000
-
E Lo
N 0 0 X
O o
}o
c�Un�>
�
W
> U U �
O=
.�? °
° °w
x Q-
W
'c �
N U
O U
0 0--
;✓
Q
REVISIONS
MARK: REMARKS:
J
a
�
Fm
W
N
IL
cl)
J
Z
0
2
z
�
�
>=
U
Qa:Q
a
m
W
ix
�
W
O=
cl)U
69314
KEYPLAN
Job No:
409325.000
Date:
08 -31 -2009
Sheet Title:
GENERAL
INFORMATION -
ELECTRICAL
5-i ,' . .