09-963-003V a 0 0 J a !I 0 Eo� FC11 PW PW EXISTING LX20 TO BE REMOVE EXISTING VITROU! TO BE REMOVED, PW PW EXISTING EYEWASH EX.1' LOOP EX.1'CW \/ — At_ � 1 L7!" C> CC ol lo I� al a- 03 � � 3 n. 3 1:01 L] �11F PARTIAL FIFTH FLOOR TEMP. DEMOLITION PLAN - PLUMBING Ll i FF rHK i iAL I- It- i n rLCavH 02 4 NEW WORK PLAN - PLUMBING Ai� GENERAL NOTES A. COORDINATE WITH OWNER'S REPRESENTATIVE ALL PIPE ROUTING AND THE DEMOLITION / RESTORATION OF ALL EXISTING / NEW FINISHES. B. CONTRACTOR TO COORDINATE WITH OWNER THE WORK HOURS / SCHEDULE. PROVIDE ALLOWANCE IN YOUR BID FOR LATE HOURS / WEEKEND WORK. C. FIELD VERIFY ALL EXISTING PLUMBING ROUTING. CONNECT EQUIPMENT HOSE TO AIR GAP FITTING USING STAINLESS STEEL PIPE. CUP HOSE TO EDGE OF PIPE USING CLAMPS. USE PIPE SIZE NECESSARY TO HOLD ALL HOSES. COORDINATE WITH EQUIPMENT SUPPLIER NUMBER AND SIZE OF HOSES PROVIDE CHROME PLATTED AIR GAP FITTING TO HOLD ALL EQUIPMENT DRAIN HOSES. COORDINATE WITH EQUIPMENT SUPPLIER. PROVIDE REDUCING FITTING AS NECESSARY TO REDUCE TO 1' PIPE CONNECT TO EXISTING 1' INDIRECT WASTE FROM EYEWASH EXISTING 1' INDIRECT WASTE PIPE CONNECTS TO EXISTING FLOOR DRAIN EQUIPMENT DRAIN nn HOSE CONNECTION DETAIL V %3 NTS LEGEND NOTES O1 SHORTEN EXISTING HUB DRAIN AND ALL ASSOCIATED APPURTENANCES. REMOVE BRANCH SEWER PIPING BACK TO MAINS / RISERS. OREMOVE EXISTING PURE WATER EQUIPMENT AND ALL ASSOCIATED APPURTENANCES. REMOVE WATER LINE SERVING DI UNIT BACK TO RISER, AS HIGHLIGHTED. REMOVE COMPLETELY PURE WATER LOOP. REMOVE CONNECTIONS TO ALL SINKS, EQUIPMENT INCLUDING VALVES, FAUCETS. RESTORE ALL FINISHES (CABINETS, WALLS, SINKS, ETC.) AS REQUIRED. O3 ON THE EYEWASH'S INDIRECT WASTE CONNECTION PROVIDE A 1' TEE FOR NEW ANALYZER WASTE DISCHARGE CONNECTION. RUN HOSES FROM ANALYZERS TO NEW TEE AND CONNECT WITH AIR GAP FITTING. HOSES TO BE CONNECTED TO FITTING SUCH AS PROVIDE EASY ACCESS TO END OF HOSE IN ORDER TO BE USED AS SAMPLING PORT BY DERM INSPECTOR OR ANY OTHER AUTHORITY HAVING JURISDICTION. SEE DETAIL 03 THIS SHEET. OPER MANUFACTURER DATA SHEETS AND INFORMATION RECEIVED FROM HOSPITAL SEE BELOW LISTED ALL SUBSTANCES THAT COULD BE FOUND IN THE WASTE STREAMS FROM THE VISTA CHEMISTRY ANALYZERS AND THEIR CORRESPONDING LIMITS IN THE WASTES. WE HAVE LISTED ALL REGULATED SUBSTANCES SUCH AS DESCRIBED IN SECTION 24.42.4 OF THE MIAMI -DADE COUNTY CODE. • MERCURY - 0.00 mg /L CHROMIUM < 0.05 mg/L • POLY CHLORINATED BIPHENYLS < 0.008 mg/L • ESTIMATED pH - BETWEEN 6 AND 7 _ ,,-/ 0 LO r) 0 �U m`^cvc� 0 % - Z �vi LoLoCV)0' L6 L'i0 �C)�� D� 0 a__� D-_ oo CV � �O X O j c�UQa E }o U U p .(D m 9 p Qw - c X °c — (D U — O U o p a U o Q REVISIONS MARK: REMARKS: I0 I BUILDING DEPARTMENT COMMENTS 1 11 /2A Innnn J � Q W � N CL CD ~ = Z W - a LL a>_a �cl) a W m Ir O= cl)U a � w �. AAA KEYPLAN Job No: 409325.000 Date: 08 -31 -2009 Sheet Title: PARTIAL FIFTH FLOOR PLANS PLUMBING Sheet No: P2.02