09-963-001Q 0 0 J CL GENERAL NOTES A. LOCATION OF EXISTING PLUMBING EQUIPMENT AND APPURTENANCES HAVE BEEN TAKEN FROM 'AS- BUILT" DOCUMENTS. THE CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EXISTING PLUMBING EQUIPMENT AND APPURTENANCES THAT WILL REQUIRE SOME TYPE OF MODIFICATION DUE TO THE RENOVATION AND /OR NEW CONSTRUCTION OF THIS CONTRACT PRIOR TO PRICING AND COMMENCEMENT OF WORK. B. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS WITHIN THE DEMOLITION AREAS DEPICTED IN THE DEMOLITION DRAWINGS AND SHALL ASCERTAIN THE EXTENT OF WORK REQUIRED WITHIN THE DEMOLITION AREAS PRIOR TO PRICING AND COMMENCEMENT OF WORK. C. ITEMS REMOVED AND NOT REINSTALLED OR RETURNED TO OWNER SHALL BE DISPOSED OF LEGALLY (COORDINATE WITH OWNER DISPOSAL OF ITEMS). D. REMOVE EXISTING PIPING, WHERE NOTED OR REQUIRED, TO BEYOND FINISHED SURFACES AND CAP AS REQUIRED OR INDICATED ON PLANS. VERIFY EXACT LOCATION OF EXISTING PLUMBING AT SITE. E. ANY EXISTING PLUMBING RISER LOCATED IN WALLS /CHASES INDICATED TO BE DEMOLISHED MUST BE RELOCATED TO A CONVENIENT LOCATION. F. REFER TO THE ARCHITECTURAL PHASING PLAN FOR THE PHASING OF CONSTRUCTION. WORK SHALL BE SCHEDULED AND PERFORMED IN SEQUENCE WITH THE ARCHITECTURAL PHASING PLAN. G. DEMOU11ON OF EACH PHASE SHALL OCCUR AS PART OF THE WORK FOR THAT PHASE. REMOVE ONLY THE WORK THAT SERVES THE AREA OF DEMOLITION. H. PROVISIONS SHALL BE MADE BY THE CONTRACTOR TO PREVENT DISRUPTING ADJACENT AREAS OF THE PHASE IN WHICH WORK IS BEING PERFORMED. I. PROVIDE ADDITIONAL VALVES, TAPS, TEMPORARY PIPING, ETC. AS NECESSARY TO PROVIDE UNINTERRUPTED SERVICE TO AREAS OUTSIDE OF THE PHASE IN WHICH WORK IS BEING PERFORMED. J. CONTRACTOR SHALL BE RESPONSIBLE FOR REVIEWING THE EXISTING CONDITIONS AT THE JOB SITE BEFORE SUBMITTING PROPOSALS. SUBMISSION OF PROPOSALS SHALL BE TAKEN AS EVIDENCE THAT SUCH INSPECTION HAS TAKEN PLACE. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE COMPLETE SET OF CONSTRUCTION DOCUMENTS, AND THE LACK OF SPECIFIC INFORMATION ON THE DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR OF ANY RESPONSIBILITY. K. UNLESS NOTED OTHERWISE, THE MECHANICAL DEMOLITION SHALL BE CARRIED OUT TO THE EXTENT THAT THE FLOORS ARE RETURNED TO THE ORIGINAL BASE BUILDING CONDITIONS. CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS IN ORDER TO ACCURATELY DETERMINE THE EXTENT OF THE WORK UNDER THIS SECTION. L. WASTE, DOMESTIC WATER, AND VENT PIPING SHALL BE REMOVED BACK TO RISER STACK CONNECTIONS AND CAPPED, UNLESS NOTED OTHERWISE. M. REFER TO FLORIDA BUILDING CODE - PLUMBING 2004 FOR ALL PLUMBING FIXTURE AND PLUMBING SYSTEMS REQUIREMENTS. PLUMBIW n:a u Wr v SYMBOLS d ALL SYMBOLS SHOWN MAY NOT APPEAR IN ALL DRAWINGS. SYMBOLS ARE SHOWN 5CHEMAT� 11CALLY AND MAY NOT BE TO SCALE. '> ,� •�� ;,�� •�.- SYMBOL DESCRIPTION SYMBOL n. ®T DESCRIPTION DOMESTIC COLD WATER GAUGE COCK -iJ 'TION -- — DOMESTIC HOT WATER (1207 UNLESS OTHERWISE NOTED) (�) _ PRESSURE GAUGE WITH GAUGE COCK - - -- - DOMESTIC HOT WATER RETURN (1207 UNLESS OTHERWISE NOTED) _ . � COLD OR HOT REDUCED PRESSURE PRINCIPLE _ THERMOiMETT -R WITH SHUT -OFF COCK BACKFLOW PREVENTER R.P.P.B.P. — EX EXISTING PIPING TO REMAIN HOSE BIBB (H.B.) OR WALL HYDRANT (WH) X - -X - -X IX EXISTING PIPING TO BE REMOVED --- �-- RECESSED BOX WALL HYDRANT - il- #-h-= PIPING TO BE ELECTRICALLY HEAT TRACED —� YARD HYDRANT _SS — SANITARY SEWER PIPING (SOIL OR WASTE) � ,- �-- SANITARY VENT PIPING SLEEVE THRU WALL SSD SUB -SOIL DRAIN PIPING, FOOTING DRAIN PIPING EXPANSION LOOP W DWG No. CSS CLINICAL SERVICE SINK SH SHOWER DS DOWNSPOUT SD SHOWER DRAIN DF DRINKING FOUNTAIN S. -SK. SINK EWC ELECTRIC WATER COOLER UR URINAL FD FLOOR DRAIN VTR VENT THROUGH ROOF, FS FLOOR SINK WS WASH SINK FRS FLUSH RIM SINK WH WALL HYDRANT GC GENERAL CONTRACTOR WC WATER CLOSET GCO GRADE CLEANOUT YCO YARD` CLEANOUT WCO WALL CLEANOUT �^ SED— SEWAGE EJECTOR DISCHARGE PIPING (PUMPED SANITARY) CD — �U CO 10 CLEANOUT PLUG m N c o co a o a)M��z a� 10 �'o ( �ro CONNECT NEW TO EXISTING p, c -- SD N O O c^ SPRINKLER SYSTEM FLOOR CONTROL ASSEMBLY ciU Q -oo STORM OVERFLOW DRAIN PIPING (OD) U U O C SPD SUMP PUMP DISCHARGE PIPING (PUMPED STORM WATER) m p pw FLOW SWITCH — G — X 0- — CA — w S` FIRE HOSE VALVE FIRE HOSE CABINET (SURFACE MOUNTED) — V — VACUUM PIPING —ATV— 0 U �- FIRE HOSE CABINET (RECESSED) F — o p � 2 -WAY SIAMESE FIRE DEPARTMENT CONNECTION DFS — DRY FIRE STANDPIPE PIPING �- o c •E N SPRINKLER PIPING (SPRK.) o D a 4 -- AW ACID WASTE PIPING --- ANCHOR REVISIONS AV ACID VENT PIPING FCO —� GCO FLOOR CLEANOUT OR GRADE CLEANOUT MARK: REMARKS: 1 W INDIRECT WASTE — PASP — PRE - ACTION SPRINKLER PIPING -- UNION - -0-4- GATE VALVE — OX MEDICAL OXYGEN PIPING ----} �- BUTTERFLY VALVE MA MEDICAL AIR PIPING ---- BALL VALVE W — MV MEDICAL VACUUM PIPING 004 GLOBE VALVE sr� —WAG WASTE ANESTHETIC GAS EVACUATION �- TEMPERATURE AND PRESSURE RELIEF VALVE N MEDICAL NITROGEN PIPING J - --#- -- GAS COCK /PLUG VALVE —N20 MEDICAL NITROUS OXIDE PIPING SOLENOID VALVE O W 4 MASTER ALARM SENSOR ---�— PRESSURE REGULATION VALVE (PRV) m z g � _ Q IN -LINE CIRCULATING LOCAL ALARM SENSOR 6 UJ T AIR CHAMBERS MEDICAL GAS PIPING DROPS IN WALL FULL `;SIZE AQUASTAT PLUMBING ABBREVIATIONS _ Q ----- CHECK VALVE AFF ABOVE FINISH FLOOR INV 'r'.INVERT CHECK VALVE WITH AUTOMATIC BALL DRIP AFG ABOVE FINISH GRADE I.E. INVERT ELEVATION BACK WATER VALVE A/C ABOVE HUNG CEILING LT ` LAUNDRY TRAY W O>F J-I VALVE IN VERTICAL AP ACCESS PANEL OR DOOR L. -LAV. .;LAVATORY ._ AC AIR CHAMBER NPW NON POTABLE WATER Fm cr _ GAS PRESSURE REGULATOR VALVE AD AREA DRAIN MS MOP SINK BASIN BT BATHTUB D W --�-- BALANCING VALVE PD PLANTER DRAIN BFF BELOW FINISH FLOOR PRV PRESSURE REDUCING VALVE 0 - STRAINER WITH BLOW -OFF VALVE B/F BELOW FLOOR RD ROOF DRAIN B/G BELOW GRADE v —�— STRAINER , � ..: SS SERVICE SINK OR SLOP SINK . DWG No. CSS CLINICAL SERVICE SINK SH SHOWER DS DOWNSPOUT SD SHOWER DRAIN DF DRINKING FOUNTAIN S. -SK. SINK EWC ELECTRIC WATER COOLER UR URINAL FD FLOOR DRAIN VTR VENT THROUGH ROOF, FS FLOOR SINK WS WASH SINK FRS FLUSH RIM SINK WH WALL HYDRANT GC GENERAL CONTRACTOR WC WATER CLOSET GCO GRADE CLEANOUT YCO YARD` CLEANOUT WCO WALL CLEANOUT �^ SED— SEWAGE EJECTOR DISCHARGE PIPING (PUMPED SANITARY) CD — CONDENSATE DRAIN PIPING CO 10 CLEANOUT PLUG DPD— DRIP PAN DRAIN PIPING --��cc-- OS & Y VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) -4�— CONNECT NEW TO EXISTING INDICATING BUTTERFLY VALVE SUPERVISED (HORIZ. POSITION /VERT. POSITION) -- SD STORM DRAIN PIPING (SD) rC„ SPRINKLER SYSTEM FLOOR CONTROL ASSEMBLY OD STORM OVERFLOW DRAIN PIPING (OD) DOUBLE CHECK VALVE ASSEMBLY (D.C.V.A.) WITH OS & Y VALVES SUPERVISED ' SPD SUMP PUMP DISCHARGE PIPING (PUMPED STORM WATER) FLOW SWITCH — G — NATURAL GAS PIPING — CA — COMPRESSED AIR PIPING mTTnT! FIRE HOSE VALVE FIRE HOSE CABINET (SURFACE MOUNTED) — V — VACUUM PIPING —ATV— ATMOSPHERIC VENT PIPING (STEAM OR HOT VAPOR) �- FIRE HOSE CABINET (RECESSED) F — FIRE PROTECTION (STANDPIPE, SPRINKLER, SERVICE) -qi 2 -WAY SIAMESE FIRE DEPARTMENT CONNECTION DFS — DRY FIRE STANDPIPE PIPING �- DIRECTION OF SLOPE — SP — SPRINKLER PIPING (SPRK.) —SDR— SPRINKLER DRAIN RISER PIPING DIRECTION OF FLOW —DSP— DRY SPRINKLER PIPING CAP OUTLET OR PLUGGED OUTLET — PASP — PRE - ACTION SPRINKLER PIPING -- UNION - -0-4- GATE VALVE — OX MEDICAL OXYGEN PIPING ----} �- BUTTERFLY VALVE MA MEDICAL AIR PIPING ---- BALL VALVE W — MV MEDICAL VACUUM PIPING 004 GLOBE VALVE sr� —WAG WASTE ANESTHETIC GAS EVACUATION �- TEMPERATURE AND PRESSURE RELIEF VALVE N MEDICAL NITROGEN PIPING J - --#- -- GAS COCK /PLUG VALVE —N20 MEDICAL NITROUS OXIDE PIPING SOLENOID VALVE O W 4 MASTER ALARM SENSOR ---�— PRESSURE REGULATION VALVE (PRV) m z g � _ Q IN -LINE CIRCULATING LOCAL ALARM SENSOR 6 UJ T AIR CHAMBERS MEDICAL GAS PIPING DROPS IN WALL FULL `;SIZE AQUASTAT PLUMBING ABBREVIATIONS _ Q ----- CHECK VALVE AFF ABOVE FINISH FLOOR INV 'r'.INVERT CHECK VALVE WITH AUTOMATIC BALL DRIP AFG ABOVE FINISH GRADE I.E. INVERT ELEVATION BACK WATER VALVE A/C ABOVE HUNG CEILING LT ` LAUNDRY TRAY W O>F J-I VALVE IN VERTICAL AP ACCESS PANEL OR DOOR L. -LAV. .;LAVATORY ._ AC AIR CHAMBER NPW NON POTABLE WATER Fm cr _ GAS PRESSURE REGULATOR VALVE AD AREA DRAIN MS MOP SINK BASIN BT BATHTUB D W --�-- BALANCING VALVE PD PLANTER DRAIN BFF BELOW FINISH FLOOR PRV PRESSURE REDUCING VALVE 0 - STRAINER WITH BLOW -OFF VALVE B/F BELOW FLOOR RD ROOF DRAIN B/G BELOW GRADE v —�— STRAINER , � ..: SS SERVICE SINK OR SLOP SINK . PLUMBING SHEET LIST DWG No. CSS CLINICAL SERVICE SINK SH SHOWER DS DOWNSPOUT SD SHOWER DRAIN DF DRINKING FOUNTAIN S. -SK. SINK EWC ELECTRIC WATER COOLER UR URINAL FD FLOOR DRAIN VTR VENT THROUGH ROOF, FS FLOOR SINK WS WASH SINK FRS FLUSH RIM SINK WH WALL HYDRANT GC GENERAL CONTRACTOR WC WATER CLOSET GCO GRADE CLEANOUT YCO YARD` CLEANOUT SCALE PO.00 �^ HYDRAULIC SHOCK ARRESTOR (SA) �0�.,. i --- Va— VACCUUM BREAKER (VB) - -� FLOOR DRAIN W/ P -TRAP Do HUB DRAIN (ALL TYPES) (SPECIFY) ® ® FLOOR DRAIN (ALL TYPES) (SPECIFY) -4�— DOUBLE CLEANOUT, 2 -WAY CLEANOUT (GRADE) (D.C.O.) PLUMBING SHEET LIST DWG No. DRAWING TITLE SCALE PO.00 GENERAL INFORMATION — PLUMBING NTS P2.01 PARTIAL FIFTH FLOOR PLANS — PLUMBING 1/4' = 1' -0" P2.02 PARTIAL FIFTH FLOOR PLANS — PLUMBING 1/4' = 1' -0" P3.00 PLUMBING SPECIFICATIONS NA _x11'4, DEPT". 84 f�IJITIJRAI 9E( TION ?UVEp BY: KEYPLAN Job No: 409325.000 Date: 08 -31 -2009 Sheet Title: GENERAL INFORMATION PLUMBING Sheet No: P0000