09-720-011UNISTRUT ACROSS TFE TOP OF THE EQUIPMENT AT EACH END. 22.5° MIN.— WASHER 1-1/2 O.D X IOG 5/8' EYE BOLT DOUBLE CABLE CLAMPS TYR AT ALL POINTS 5/16 ' 6X7 GALV. WIRE ROPE GUY 5/8 EYE BOLT. IF FASTENED TO STEEL TO BE DONE SAME AS TOP EYE BOLT. IF INSERTED IN CONC. USE 'RED HEAD' R -58 SELF DRILLING CONC. ANCHOR E EYE BOLT W/ 1 -1/2" MIN. THREAD DEPTH. EQUIPMENT HURRICANE ANCHORING DETAIL N.T.S. NOTE: I: EACH OF 4 CORNERS OF ROOF MTD. EQUIP TO BE GUYED IN THIS FASION. ALL HARDWARE TO BE GALV. OR CADMIUM PLATED FORGET STEEL ASTM-A-325 2- INSTALLATION MUST MEET MINIMUM OF 150 MPH WIND LOANDNNG, MINIMUM REQUIREMENTS ARE I -EREBY II�ICATED, HOWEVER BASED ON ACTL�2AL EQUIPMENT INSTALLED EPA (EFFECTIVE PROJECTED AREA) ADDITIONAL SECURING SHALL BE PROVIDE 4 'NUTS PAD CONDENSING UNIT MOUNTING DETAIL MITSUBISHI N.T.S. NOTE: I. INSTALLATION MUST MEET MINIMUM OF 150 MPH WIND LOADING, MINIMUM REQUIREMENTS ARE HEREBY INDICATED, HOWEVER BASED ON ACTURAL EQUIPMENT INSTALLED EPA ( EFFECTIVE PROJECTED AREA) ADDITIONAL SECURING SHALL BE PROVIDED. 2. CORROSION PROTECTION. BUILDINGS LOCATED WITHIN 3,000 FT. OF THE OCEAN SHOULD USE NON- FERROUS METAL, STAINLESS STEEL OR STEEL WITH MINIMUM G -90 HOT -DIP GALVANIZED COATING FOR EQUIPMENT STANDS AND ANCHORS AND STAINLESS STEEL SCREWS. 3. MECHANICAL SYSTEMS SHALL BE EITFER PLACED ABOVE THE BASE FLOOD ELEVATION OR PROTECTED SO AS TO PREVENT WATER FROM ENTERING OR ACCUMULATING WITHIN THE EQUIPMENT, APPLIANCES, DUCTS OR PLENUM SPACE DURING FLOODS UP TO THE BASE FLOOD ELEVATION. 4. SEAL ENTRANCE OF REFRIGERANT LIDS INTO PVC PIPE W /IMPERMEABLE, RESILIENT MATERIAL (SEE DETAIL). 5. AN ANCHOR BOLT W/ MINIMUM 500 LBS PULL OUT RESISTANCE SHALL SECURE THE AC CONDENSER UNITFROM WITHIN THE UNIT THROUGH THE CONC. SLAB ON WHICH THE UNIT RESTS.(ANTI- TI-EFT BOLT). (MDC CH 8-C SEC. 8G-5) SURFACE t CHANNEL L THROUGH 1 OF THE CH W UNISTRUT CHANNEL ON EACH FLOOR. 16 GA. SHEET METAL SADDLE FOR INSULATED PIPES 1/4' THICK NEOPRENE SLEEVE FOR UNINSULATED PIPES. REFRIGERANT PIPE RISER SUPPORT DETAIL N.T.S. METAL PIPE OR CONDUIT I, 2, 3, OR 4 HOUR FIRE RATED CONCRETE FLOOR SLAB. .7•5: 9 � USE 3M CP -25 WB W SELF - LEVELING CAULK ON HORIZONTAL SURFACES WHEN FILLING GAPS FROM ABOVE THE PENETRATION. USE 3M CP -25 WB W NO SAG CAULK ON VERTICAL SURFACES AND ON HORIZONTAL SURFACES WHEN FILLING GAPS FROM BELOW. DAMPING MATERIAL INSULATION (IF REQUIRED BY SPECIFICATION 1, 2, 3, OR 4 HOUR RATED CONCRETE BLOCK WALL FOR SOLID CONCRETE WALL (SEE NOTE 1) INSULATION (IF REQUIRED BY SPECIFICATION FILL GAP COMPLETELY AROUND PIPE WITH 3M CP -25 WB W CAULK (SEE NOTES 3-5) DAMPING MATERIAL (FIBERGLASS INSULATION, BACKER ROD OR MINERAL WOOL) ENOUGH TO SUPPORT WEIGHT OF 3M CP -25 WB W CAULK. SECTION VIEW (SLAB) NOTES: PIPE 1. FOR SOLID CONCRETE WALLS. CENTER 3M CP -25 WB ( *) CAULK OR CONDUIT WITHIN WALL WITH DAMPING MATERIAL ON ONE SIDE. 2. RECOMMENDATIONS BASED ON PRODUCT PERFORMANCE PER ASTM E -814 (UL -1479) FIRE TEST AND UL CLASSIFICATION FIRE STOP SYSTEM CAJ -1175. 3. WET INSTALLED DEPTH OF 3M CP -25 WB ( *) CAULKS DEPENDS ON 3M CP -25 WB W N/S CAULK TYPE AND SIZE OF PIPE: AND DESIRED RATING. BOTH SIDES OF WALL WET DEPTH PIPE SIZE FIRE RATING (SEE NOTE) 1/2" 03MM) MAX. e (203MM) 1 -2 HRS. I' (25MM) MAX. e (203MM) 3 -4 HRS. 4. UP TO 40% SHRINKAGE OF 3M CP -25 WB ( *) CAULK IS ACCEPTABLE AFTER INITIAL WET DEPTH INSTALLATION. SECTION VIEW (WALL) 5. MAXIMUM ANNULAR SPACE TO BE FILLED IS 13/8" (35MM). UL APPROVED PIPING SAFING ASSEMBLIES EQUAL TO UL SYSTEM uCAJ-1175 FOR INSULATED PIPE AND SYSTEM uWJ-1009 FOR NON INSULATED PIPE PIPE PENETRATION FIRESTOP DETAIL N.T.S. ( *) (OR APPROVED EQUIVALENT) U.L. SYSTEM NO. WL1092 STEEL PIPE THROUGH I -HR. OR 2 -HR. GYPSUM WALL ASSEMBLY F RATING = I -HR. OR 2 -H2. T RATING = 0 -HR. FRONT VIEW SECTION A -A A'=i ! - A _j I. GYPSUM WALL ASSEMBLY (I -HR. OR 2 -HR. FIRE- RATING)(2 -HR. SHOWN). 2. PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A. MAXIMUM 6" DIAMETER STEEL PIPE. B. MAXIMUM 4" DIAMETER STEEL CONDUIT. C. MAXIMUM 4' DIAMETER EMT. 3. MAXIMUM 10' DIAMETER STEEL SLEEVE (MINIMUM 28 GAGE SI -;EET METAL OR NO. 8 STEEL WIRE MESH). 4. MINERAL WOOL (MIN. 4 PCF DENSITY) TIGHTLY PACKED (SEE NOTE NO. 2 BELOW). 5. MIN. 1 -114' DEPTH HILTI FS -ONE HIGH PERFORMANCE INTUMESCENT FIRESTOP SEALANT. NOTES: I. MAXIMUM DIAMETER OF OPENING . 10'. 2. THICKNESS OF MINERAL WOOL TO BE ONE OF THE FOLLOWING: A. MINIMUM 1 -1/4" THICKNESS FOR A 1 -1-12. FIRE -RATED SYSTEM. B. MINIMUM 2 -1/2' THICKNESS FOR A 2 -HR. FIRE -RATED SYSTEM. 3. ANNULAR SPACE = MINIMUM I% MAXIMUM 2 -3/8 ". SEE HILTI F12ESTOP INSTALLATION MANUAL FOR ADDITIONAL INSTRUCTIONS HILTI, INC. TULSA, OK 1- 800-879 -8000 -PRO,,,, No.-18002.5 EB0000924 LOUIS LAGUIRRE & ASSOCIATES P.A. a" C.OkSJLTING ENGINEERS 950 SOUTH - DADELAND BLVD. SUITE 900 MIAMI, FLORIDA 33156 TELEPHONE: (305) 670 -0141 FA-k- - - --(303) 670 -0144 E-MAIL ADnESS:- GRALMAIL@LJAAPA.COM Revisions: A a A a: a " LL f Ts' Q �6 z a z J,v u.. Q.. Q o ci�`�pV a`Q x0 0 Q44 w- w-�z4 Omu " 0 I �� Q.. Q o w- �pmmm" C� 0 pmm a O Q x v ono -0oa� o a PERMIT SET DRAWN. J.H.,J.B. CHECKED: E.S. E.Z. DATE: 0- 1 -21 -O B ISCAL A5 NOTED Sheet No. M7.00 JOB # 2 013 w- Sheet No. M7.00 JOB # 2 013