Loading...
09-720-001r "I South Miam Hospital Affiliate of Baptist Health Systems of South Flori I.- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER. 2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITIONS ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3: DIMENSIONS PROVIDED ARE NOMINAL, NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION, IF CON- TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISCRE TION OF THE OWNER OR THE ARCHITECT, THE WORK HAS TO BE RE -DONE. 4.- SHUTDOWN OF UTILITIES, IF A SHUTDOWN OR ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONT12AC TOR MUST NOTIFY THE OWNER, 72 HOURS IN ADVANCEAND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE, ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUC TION CONTRACT. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. 11.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL. 12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. 13 CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NON - CONFORMING ITEMS TO ARCHITECT'S AND ENGINEERS ATTENTION. 14.- GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15: DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME 16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18.- ELEVATION AND LEVELS: A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19.- ALL INTERIOR GYPSUM WAIL BOARD IS 5/8' TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON FLOOR PLANS, SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W.B. 20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS. AND JANITORS CLOSETS. 2I.- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT. 2Z- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK. 23.- LOCATION AND SIZE OF CEILING AND WALL. ACCESS PANES SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATIONS OF ACCESS PANELS PRIOR TO INSTALLATION. 24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS, A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26.- WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL. 27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INT621M SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28.- SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL., ELECTRICAL FIXTURES. 29.- STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2'-0'. UNLESS OTHERWISE NOTED. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE- MENTS. CONTRACTOR SHALL PROVIDE ALL NECESSARY INSULA- TION/FIRE PROTECTIVE COATINGS. 31, CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REOUIRED TO PULL SEPARATE DEMOLITION PERMIT. BAPTIST HEALTH BREAST CENTER ADDITIONA A SoLtT]Fi 41AMI MEDICAL ARTS BUILDING 6200 S.W. 73 STREET TEL: (786) 662 -4175 L0 :1111• JIS J. AGUIRRE & ASSOCIATES PJ 9150 SOUTH DADELAND BLVD. SUITE 901 MIAMI, FLORIDA CITY MAP F.AA I I mw 4 i W.AA -w'k,5 I F.AA SOUTH MIAMI, FLO Fax: (786) 668 -5156 JULY 279 2009 O D D O architect s FLORIDA LICENSE tM0002689 2100 Pence de Leon Blvd State 1170, Coral Gables, Florida 33134 TeL• (305)265 -7177 Fax: (305)262 -8435 LUIS E. NAYA, A.I.A FI. AR0008063 PROJECT NUMBER: 29013 PERMIT SET INDEX OF DRAWINGS ARCHITECTURAL A -1 AC UNIT AND LOCATON - ROOM 127 AND 128 MO.00 SYMBOL LEGEND AN GENERAL NOTES - HVAC. M3.00 PARTIAL FLOOR PLAT - HVAC. M3.01 PARTIAL FLOOR PLAT WATER PIPING - HVAC. M3.02 CHILLER AREA PARIAL FOOR PLAN AND SECTION - HVAC. M7.00 DETAILS - HVAC. I ELECTRICIL E0.00 SYMBOL LEGEND AN GENERAL NOTES - ELECTRICAL. I E3.03 PARTIAL FLOOR PLA? - POWER ELECTRICAL. E3.05 PARTIAL 2ND FLOORPLAN - POWER ELECTRICAL. E5.00 PANEL RISER DIAGRM AND PANELBOARD SCHEDULE - ELECTRICAL. BUILDIVG INFORMATION I REVISIONS j• ORIGINAL 3UILDING DESCRIPTION a BUILDING a JURISDICTION : SOUTH MIAMI, MIAMI DADE COUNTY PRIMARY USE CLASS : BUSINESS a NUMBER OF STORIES : 6 FLOOR EXISTING BUILDING Q ADDITIONAL A/C UNl a LICABE CODES d a a ABBR-EVIATIONn-' A1Wa 1MCTURo4L YI=:C1 V& -W0f .NG MMUMS t AND w L ANGLE • AT L LENGTH C CENTERING LAM LAMINATE O DIAMETER LAY LAVATORY • POUND OR NUMBER L55 POUNDS A L55/4R POUNDS PER HOUR LD LINEAR D!T?!"ER A/C AIR CONDITIONING LP LOW POINT ACI AMERICAN CONCRETE INSTITUTE LT LIGHT ACP ASBESTOS CEMENT PIPE ACSC ASPHALTIC CONCRETE SURFACE COURSE ACU AIR CONDITIONING UNIT ACT ACOUSTICAL CEILING TILE MATL MATERIAL AD AREA DRAIN MAX MAXIMUM ADJ ADJUSTABLE MC MEDICINE CABINET A/E ARCHITECT/EWiNEER MC 44 MECHANICAL AF ACCESS FLOORING MEMB MEM5RANE AFF ABOVE FINISHED FLOOR MFR MANUFACTURER AGGR AGGREGATE MIN MINIMUM AHU AIR HANDLING UNIT MISG MISCELANEOUS ALT ALTERNATE MO MASONRY OPENNG AL ALUMINUM MTD MOUNTED ANN ANNUNCIATOR MTL METAL ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MUL MULLION ANT ANTENNA MULT MULTIPLE AP ACCESS PANEL H APL ACCESS PLENUM APROX APPROXIMATE ARCH ARCHITECTURAL N NORTH ASS ASBESTOS NEC NATIONAL ELECTRIC CODE ASPH ASPHALT NIG NOT IN CONTRACT ASTM AMERICAN SOCIETY OF TESTING t MATERIALS NO NUMBER a ROM NOMINAL NPL NAME PLATE SAT BATTERY NTS NOT TO SCALE SD BOARD G 51TUM BITUMINOUS BLDG BUILDING BLKG BLOCKING OA OVERALL SM SEAM OSS OBSCURE SOT BOTTOM OC ON CENTER co oD OUTSIDE DIAMETER DIM) OFS OVERFLOW SCUPPER GAS CABINET OPP OPPOSITE CB CATCH BASIN CEM CEMENT to CER CERAMIC CFM CUBIC FEET PER MINUTE CG CORNER GUARD PG PRECAST CO�RETE GHP CRICKET HIGH POINT PJ Ili PIPE JOINT CI CAST IRON PL CC CAST IRON DOVER P LAM PLASTIC LAMNATE GIP CAST IRON PIPE PLAS PLASTER CONTROL JOINT PLYUO PLYWOOD CLG CEILING PNT PAINT GLGD CEILING DIFFUSER PT F'TD PONT OR PATIENT PAPER TOWEL DISPENCER CLKG CAULKING FN PARTITION CLO CLOSET PTR PAPER TOWEL RECEPTACLE CLP CRICKET LOW PONT CLR CLOSER CMP CORRUGATED METAL PIPE Q Cm CONCRETE MASONRY UNIT C C CRT QUARTER GO O . O CLEAN O UT QT QUARRY TILE COL COLUMN COMM COMMUNICATION CONC CONCRETE R COON CONNECTION CONSTS CONSTRUCTION R REAR CONT CONTINUOUS RA RETURN AIR CPT CARPET TILE RAO RADIUS CT CERAMIC TILE RS REINFORCED BEAM CTR CENTER RCPT RECEPTION CTSK COUNTERSUNK RD ROOF DRAIN a REF REFERENCE REINF REI?FOIRCED REQ REQUIRED DBL DOUBLE RESL RESILIENT DEG DEGREE RGTR REGISTER DEPT DEPARTMENT R ROOM DESIGNATION O IRO R OPENING DET DETAIL RWL RAIN WATER LEADER DF DRINKING FOUNTAIN DG DOOR GRILLE DIA DIAMETER d DIAG DIAGRAM DIM DIMENSION DISK DISPENSER S STUCCO DN DOWN SC SCREED CONCRETE DO DOOR OPENING SC 4ED SCHEDULE DSP DRY STANDPIPE C SECOND 05 DOWN SPOUT g SMOKE DETECTOR DUJGS DRAWINGS SECT SECTION DWR DRAWER SF SUPPLY FAN SG SPANDREL GLASS SGR SYNTHETIC GRADE SHR SHOUTER EA EACH SHT SHEET EC EPDXY COATING SIG SC04AL EHO ELECTRIC HAND DRYER SIM SK SIMILAR SINK EL ELEVATION METAL EJ EXPANSION JOINT SSm ELEC ELECTRICAL SND SOUND ELEv ELEVATOR SPEC SPECIFICATION EMER EMERSENCY SFKR SPEAKERS ENCL ENCLOSURE 50 SQUARE ENGR ENGINEER SGFT SQUARE FEET EPNL ELECTRICAL PANEL SST STAINLESS STEEL EQ E EQUAL EQUIPMENT ST STREET EST ST ESTIMATE STG SOUND TRANSMISSION COEFFICIENT STD STANDARD ET EXPANSION TANK ST -D STORM DRAIN EWC ELECTRIC WATER COOLER STL STEEL EXH EXHAUST STRL STRUCTURAL EXST EXISTING SUSP SUSPENDED EXT EXTERIOR 5YM SYMMETRICAL SYS SYSTEM T FA FIRE ALARM FABL FIRE ALARM SELL FD FLOOR DRAIN T TOILET FG FISERrsLASS TS TIE SEAM FCO FLOOR CLEANOUT TG TEL TIE COLUMN TELEPHONE FD FIRE DAMPER TEMP TEMPERATURE FDC FIRE DEPARTMENT CONNECTOR TANG TONGUE AND GROVE FOR FIRE DOOR Ti-K THICK PON FOUNDATIONS TOG TOP OF CURET F DV FIRE DEPARTMENT VALVE TOPP TOP O' PARAPET FEC FIRE EXTINGUISHER CABINET TOS TOP OF SLAB FEX FIRE EXTINGUISHER TIM TOP OF PAVEMENT FF FINISH FLOOR TRD TREAD PH FIRE HYDRANT TS TUBULAR STEEL FIN FINISH TSTAT THERMOSTAT FL FLOOR TV TELEVISION Fit FACTORY MANUAL TW TOP OF WALL FLASH FLASHING TYP TYPICAL FLG FLANGE FLOUR FLUORESCENT U FOG FACE OF CONCRETE FO= FACE OF FINISH US UNDERCUT FOM FACE OF MASONRY UL UNDERWRITER'S LABORATORIES FOS FADE OF STUD FPRF FIREPROOF UON UNLESS OTHERWISE NOTED FPM FEET PER MINUTE U05 UNLESS OTHER SPECIFIED F FRENCH DRAM UR URINAL FS s FULL slzE UTIL UTILITY PT FOOT OR FEET FTG FOOTING V FT -LS FOOT POUNDS PURR FUMING VB VINYL BASE PUT FUTURE VCT VINYL COMPOSITION TILE VERT VERTICAL a VEST VESTIBULE VF VERIFY IN FIELD VOL VOLUME GA GAUGE VT VAPOR TIGHT GAL GALLON VTR VENT THRU ROOF GALV GALVANIZED GB GRADE SEAM W GEN GENERATOR GL GLASS GND GROUND WR WIRE GLB GLASS BLOCK W WINDOW GR GRILLE W/ WITH GRO GRADE WC WATER CLOSET GU5 GYPSUM WALL BOARD WGO WALL CLEANOUT GYP GYPSUM UP WALL FABRIC W/O WITHOUT WP WATER PROOF 14 CT. WW I SIC HS HOSE BIB UJiLF WELDED WIRE FABRIC HC HANDICAPPED ULM WELDED WIRE MESH HDWD HARDWOOD HOWE HARDWARE HGT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL HP HIGH PONT HR HOUR HTR HEATER HVAC HEATING, VENTILATION, AND AIR CONDITIONING HYD HYDRANT ID INSIDE DIAMETER ( DIAM ) IN NC 4ES TNT INTERIOR F "� JAN JANITOR t JS JUNCTION SOX £mm JCT JUNCTION JSK JANITORS SINKa JT JOINT :, a t KO IC40CK OUT