09-57-025s� REGULATORY REQUIREMENTS A. NFPA 101: LIFE SAFETY CODE (2004). B. NFPA 99: STANDARD FOR HEALTH CARE FACILITIES (2002). C. ANSI HANDICAPPED CODE- A117.1. D. FLORIDA BUILDING CODE 2004 PLUMBING - GENERAL NOTES: 1. ALL EXISTING WORK NOT SHOWN ON THESE DRAWINGS ( UNLESS NOTED OTHERWISE) SHALL REMAIN AS IS. 2, THE CONTRACTOR SHALL KEEP A SET OF MARKED UP DRAWINGS AS THE JOB PROGRESSES. NO MAJOR CHANGE SHALL BE MADE TO PLUMBING DESIGN /ENGINEERING UNLESS IT HAS BEEN COORDINATED DRAWN, AND SUBMITTED FOR APPROVAL TO THE ARCHITECT. 3. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE ROUTING PROBLEMS. 4. WARRANTY /GUARANTEE A. THE CONTRACTOR SHALL WARRANTY /GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE YEAR. B. DEFECTS OF ANY KIND DUE TO THE FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE OWNER AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIR THERETO. PLUMBING - DEMOLITION NOTES: 1. CONTRACTOR SHALL REMOVE EXISTING SERVICES SUCH MEDICAL GAS, SERVING HOSE DROPS AND WALL OUTLET AND /OR CONNECTIONS TO EQUIPMENT WHICH IS TO BE REMOVED, OR RELOCATED AS INDICATED AND SHOWN ON THE DRAWINGS. PERMANENTLY SEAL AND CAP SERVICES NEXT TO MAIN SERVICE LINES ABOVE CEILING, IN WALLS. 2. EXISTING FIXTURES, EQUIPMENT, SERVICES, AND CONNECTIONS TO REMAIN AS IS, WHICH ARE DAMAGED DURING CONSTRUCTION, SHALL BE REWORKED OR REPLACED AS REQUIRED TO PROVIDE ORIGINAL OPERATION, PENETRATIONS OR OPENINGS FROM REMOVED PIPES THROUGH EXISTING WALLS AND FLOORS SHALL BE SLEEVED AND /OR PATCHED TO MATCH THE EXISTING STRUCTURE. SEE ARCHITECTURAL DRAWINGS FOR FINAL FINISHES. 4. CONTRACTOR SHALL COORDINATE INTERRUPTION OF EXISTING SERVICES; WITH OWNER, BEFORE CONSTRUCTION. 5. REPAIR /REPLACE EXISTING VALVES WHICH DO NOT HOLD WHEREVER NEW PIPING IS CONNECTED TO EXISTING PIPING, AND THE EXISTING VALVES ARE TO BE REUSED. 6. CONTRACTOR IS ADVISED THAT LOCATIONS SHOWN FOR EXISTING MEDICAL GAS SERVICES ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY LOCATIONS, MATERIALS AND SIZES OF PLUMBING SERVICES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BRING DISCREPANCIES BETWEEN THE NEW CONSTRUCTION DRAWINGS AND THE EXISTING CONDITIONS TO THE ARCHITECT'S ATTENTION FOR COORDINATION PRIOR TO CONSTRUCTION. 7. CONTRACTOR SHALL SUBMIT A COMPLETE LIST OF EQUIPMENT THAT ARE TO BE REMOVED TO THE LOCAL OWNER'S REPRESENTATIVE. ALL ITEMS THAT THE LOCAL OWNER'S REPRESENTATIVE WISHES TO RETAIN SHALL BE PLACED IN STORAGE AND THE REMAINDER SHALL BE REMOVED FROM THE SITE AND LEGALLY DISPOSED. PLUMBING FIXTURE SCHEDULE ffNEOW SYMBOL FIXTURE FITTING FLOOR MOUNTED CARRIER C.W H.W. WASTE REMARKS MANUFACTURER MODEL TYPE SIZE MANUFACTURER T TYPE SUPPLY TRAP FAUCET • • HOT WATER (BELOW FLOOR) CONNECTION TO EXISTING ---• • • HOT WATER RECIRC. (BELOW FLOOR) D CAP ON LINE —SS— SANITARY SEWER (UNDERGROUND) ; -- GAS COCK W— WASTE LINE P -22 JUST (2 COMP.) SINK *DLX- 2237 -A -GR DOUBLE COMP. STAINLESS STEEL 18 GAUGE , 16 X 16 X 10 /¢ McGUIRE GRID DRAIN '151 (2) H -2165 #8912 11/1 P -TRAP CHICAGO FAUCET *786 -GN2FC NA �/¢ i/ t�% NA - AW ACID WASTE LINE ACID WASTE RISER IDENTIFICATION -- •—AV -- ACID VENT © DOMESTIC WATER RISER IDENTIFICATION •••r •f• R • N••4• ••• N•• ••• • • • 0110, • • • • • r • r • • N • • o N r • • Y •of• 0.000 r•U ••oe •U•• • • f • • • • • • • Y ••o• r •r•f• f rrf • ••r• • �. , . ,r'M1,.+ .�_,•.+ rte:.'. .s , .�. -s• ' -�-- 'r • `• ": r PHILLIPS CONCRETE FASTENER I.T.T. GRINNELL (RED HEAD) ALL THREAD HANGER ROD PIPE HANGER RING I.T.T. GRINNELL FIG.69 PIPE HANGER RING J ` PIPE I.T.T. GRINNELL FIG.260 I PIPES 3" & SMALLER PIPES 4" & LARGER U.L. /F.M. APPROVED CONCRETE INSERT PIPING HANGER DETAIL SCALE; NONE CONSTR UCTION LEGEND ffNEOW DESCRIPTION -- EXISTING TO REMAIN -- Z BALL VALVE NEW CONSTRUCTION HOT WATER CONNECT TO EXIST. AT THIS POINT PLUMBING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION -- COLD WATER -- Z BALL VALVE -- HOT WATER L-4 CHECK VALVE -- --- -- HOT WATER RECIRCULATION 19 EXTERIOR CLEANOUT • COLD WATER (BELOW FLOOR) P -4ETC FIXTURE INDENTIFICATION • • HOT WATER (BELOW FLOOR) CONNECTION TO EXISTING ---• • • HOT WATER RECIRC. (BELOW FLOOR) D CAP ON LINE —SS— SANITARY SEWER (UNDERGROUND) ; -- GAS COCK W— WASTE LINE PIPE TURNED UP - -V--- VENT PIPE (ABOVE OR BELOW GROUND) PIPE TURNED DOWN RWL RAIN WATER LEADER .5GPM ---- -- BALANCING VALVE CIRCUIT SETTER W /CHECK VALVE SET AT 0.5GPM SW STORM WATER (UNDERGROUND) —"-�I CLEANOUT (ABOVE CEILING) Q SANITARY RISER IDENTIFICATION - AW ACID WASTE LINE ACID WASTE RISER IDENTIFICATION -- •—AV -- ACID VENT © DOMESTIC WATER RISER IDENTIFICATION PLUMBING DRAWING INDEX SHEET DESCRIPTION NO. P -0.1 SCHEDULES, LEGEND, DETAILS - PLUMBING /FIRE PROTECTION P -1.1 PARTIAL SECOND FLOOR DEMOLITION PLAN - PLUMBING P -2.0 PARTIAL UNDERFLOOR NEW WORK PLAN - PLUMBING P -2.1 PARTIAL SECOND FLOOR NEW WORK PLAN - PLUMBING i BERMELLO•AJAMIL & PARTNERS fNC Architecture Engineering Planning Interior Design Landscape Architecture 2601 So. Bayshore Drive Suite 1000 Miami, Florida 33133 (305) 859 -2050 FAX (305) 659 -9638 Smith SS1 Seckma.n Reid, Inc. 600 Wcst Hillsboro, Suitc 300 Deerfield Beach, FL 33441 (954) 421 -1260 FAX: (954) 421 -1466 www.ssr- inc.com Firm Certification - EN- 0000357 Alfral Esquivel PE - 45113 Bruce W. reek PE - 36901 Chris A. Freyer PE -43288 Dennis Davis PF - 51518 Donald Netinhf PE - 49454 John E.1Vlrulder PE - 33200 Juan Echavarria PE -19677 SSR JON * 0432103.0 STRUCTURAL ENGINEERS t' DONNELL, DUQUESNE d AL6AISA. P.A. =CONSULTING ENGINELRS _ ;;_ DRAMON R. DONNELL P.E. 0011610 CIVIL /STRUCTURAL 111H lflfl 1:111; €€ ©PEDRO J. DUOUESNEP.E. 0022764 per „c CIVIL /STRUCTURAL FIAIDA M. ALnAISA P.E. 0045130 CIVIL /STRUCTURAL ----- •- ••�•---- ••- • - - -• -- (3051 S.W. CT. MIA MT, 661- 520513315`. C �• fit_, *• Y ��: '•: 4RC� \ M^ Revisions: Project Name: SOUTH MIAMI HEART CENTER PBX RENOVATION 5200 S.W. 73 STREET MIAMI, FLORIDA 33193 l KEY PLAN LOCATIO OF NON — INVASIVE 0 Comm. No. Scale: Date: Drawn Checked: CADD File- Draw'g Title; 40002.000 12-19-08 GEN. NOTES SCHEDULES PLUMBING Sheet No. P -0.1