09-57-010TAPE & FINISH BEHIND CABINET - - - -- CORNER BEAD (TYPICAL) ELECTRIC PANEL /F.H.C. OR - OTHER WALL MOUNTED CABINET FURR WALL ABOVE do BELOW WRAP GYPSUM BOARD TOP is BOTTOM OF CABINET I RECESSED WALL CABINET DETAIL A -10.1 SCALEt 3' 4-0' 5/8" TYPE ,.X„ GYPSUM BOARD 3 5/8" METAL STUDS 5/8" TYPE "X" GYPSUM BOARD ALL FIVE SIDES TOP,BOTT., SIDES, AND REAR SHALLOW FIVE SIDE MISC. BOX IN ONE HOUR FIRE RATED WALL 4 MISCELLANEOUS BOX DETAIL -10,1 SCALE 3•4-0' WALL SHEATHING MATERIAL CONTINUOUS ALONG EXTERIOR - GYPSUM BOARD AT 2 HR WALL EXTEND RATED WALL INTO OVERHANG & PARAPET ABOVE AND /OR SILL BELOW SEAL ALL PENETRATIONS W/ ACOUSTICAL SEALANT EXTERIOR WALL MATERIAL 1 HR FIRE OR SMOKE WALL ASSEMBLY TAPE is JOINT COMPOUND EXTERIOR WALL INSULATION W/ ATTACHMENT SYSTEM 9 WALL PRIORITY DETAIL A -10.1 SCALE 39-I'-0' REFER TO PLAN FOR WALL DIMENSIONS ONE OR TWO LAYERS OF GYPSUM BOARD AS REQUIRED FOR WALL RATING i9STUD SIZE AS REQUIRED FOR PIPE SIZE TAPE k JOINT COMPOUND (TYPICAL) 1 5 WALL PRIORITY DETAIL A -10.1 I SCALB 39-l'-Ow �G7 T If11k1T Prwn1/1 it 19.2 Lul 1/11 ►IT /71/f11f111 N 51UL)a L4 V.G. GYPSUM BOARD APPLIED VERTICALLY JOINTS TO RECEIVE PERF -A -TAPE AND JOINT COMPOUND 2 JOINT REQUIREMENTS A -10.1 I SCALEt 3 "4-0' NON -RATED WALL OR ONE HOUR CONSTRUCTION 2 HR CONSTRUCTION OR 1 HR RATED. PROVIDE ONR LAYER 5/8" TYPE 'X' GYPSUM BOARD L� NON -RATED WALL OR ONE HOUR CONSTRUCTION TAPE is JOINT COMPOUND P1ART1 ON � SMOKE 6 1 WALL PRIORITY DETAIL '10.1 SCALE T -I'-0• JOINTS MAY OPPOSITE IF SAFING IS USED I A ITY. REF. CEG 8 -11 -83 'C G 5 -9 -8 JOINTS IN -ItIISH LAYERS TO RECEIVE F -A -TA E AND JOINT CDNPOUND �1 5/8" TYPE "X" GYPSUM BOARD ONE HOUR WALL 5/8- TYPE 'X' GYPSUM BOARD ONE HOUR SMOKE OR FIRE RATED PARTITION SEAL THIS SIDE SMOKE TIGHT TAPE JOINT COMPOUND NON -RATED WALL OR ONE HOUR CONSTRUCTION 7 WALL PRIORITY DETAIL -10.1 1 SCALE 3•'1' -0" 2' -0" MIN. (PER UL ACOUSTICAL SEALA T BACK AND SIDES OF BOX AS NECESSARY FOR SOUND RATING MAX. 16 SQ. INCH MAX. OPENING - •--100 SQ. IN. / 100 5Q. IN. ( PER UL ) _ L ONE OR TWO HOUR FIRE TELEPHONE OR OR SMOKE WALL ELECTRICAL BOXES ACOUSTICAL SEALANT AROUND BOX PENETRATION 11 ADJACENT ELECTRICAL BOXES A -10.1 SCALE 3' -I'-9 LOWEST PRIORITY •••• iiU U • • •••i ••• FIRE is SMOKE WALL i • • W• 44 W WALL w" i TWO ••• i W U • • W HOUR W • PRIORITY ..—.. ^�.�_w.�_'ri.w��_ HOUR FIRE WALL PRIORITY i i • W WALL PRIORITY 5 LOWEST •ii ••• w U W 0000 • i a i • •• • • •• r w w Y• r r r W W i W w W • • V Y• • W W W w i W v i HIGHEST PRIORITY, ••••w U•• iC i W • i ! • • •••i • U • W • i • W • 0 • • • • • r W "• • •r••• • ••• w it • • BERMELLO •AJAMIL & PARTIMERS • II�C � Architecture Engineering Planning Interior Design landscape Architecture 2601 So. Bayshore Drive Suite 1000 Miami, Florida 33133 (305) 859 -2050 FAX (305) 859 -9838 Smith, Seckman, Reid, Inc. i CONSLTL"I'ING ENG=N]EEIEz?, E�3 600 Heat Hillsboro, Suite 300 Deerfield =each, Florida 33441 rhone(954)421 -126p Fax(954)421 -1464 ONE HOUR FIRE RATED PARTITIONS DONNELL, DUQUESNE i AUAiSA PA CONSULTING ENGINEERS ❑RAMON R. DONNELL P.E. 0011690 CIVIL /S I HUCI OF AL EE ❑FIEDRO J. DUQUESNE P.E. 0022764 CIVIL /Sl HUCTUHAI. DAIDA M. ALaAISA P.E. 0045130 a CIVIL I$T' U131 t1RAL 3 WALL PRIORITY •......•..... • ••....... { 06) 606-0711 �h CT. MIAMI, FLOXI it{�f2p A -10.1 SCALE, N.T.S. yOR011 'fir. WALL PIS I OR I TY LEGEND TWO HOUR FIRE is SMOKE WALL PRIORITY 1 HIGHEST TWO HOUR FIRE WALL PRIORITY 2 TWO HOUR SHAFTWALL PRIORITY 2 ONE HOUR FIRE k SMOKE WALL PRIORITY 3 ONE HOUR FIRE WALL PRIORITY 4 NON -RATED WALL PRIORITY 5 LOWEST & PARTIMERS • II�C � Architecture Engineering Planning Interior Design landscape Architecture 2601 So. Bayshore Drive Suite 1000 Miami, Florida 33133 (305) 859 -2050 FAX (305) 859 -9838 Smith, Seckman, Reid, Inc. i CONSLTL"I'ING ENG=N]EEIEz?, E�3 600 Heat Hillsboro, Suite 300 Deerfield =each, Florida 33441 rhone(954)421 -126p Fax(954)421 -1464 ONE HOUR FIRE RATED PARTITIONS DONNELL, DUQUESNE i AUAiSA PA CONSULTING ENGINEERS ❑RAMON R. DONNELL P.E. 0011690 CIVIL /S I HUCI OF AL EE ❑FIEDRO J. DUQUESNE P.E. 0022764 CIVIL /Sl HUCTUHAI. DAIDA M. ALaAISA P.E. 0045130 a CIVIL I$T' U131 t1RAL 3 WALL PRIORITY •......•..... • ••....... { 06) 606-0711 �h CT. MIAMI, FLOXI it{�f2p A -10.1 SCALE, N.T.S. yOR011 'fir. ELEVATION 8 TWO DOUR SHAFT WALLS 10.1 1 SCALEII 3• -1'-0" , TEST REF.: U OF C 4 -2 -75 1" TYPE "X" GYPSUM BOAR -__ -- U OF C 6 -23 -75 C -H STUDS -SIZED AND UL DES U438 GAUGE AS REQUIRED FOR CONCEALED SIDE CONDITIONS 6574,:,x+ Revisions: Project Name: SOUTH MIAMI HOSPITAL PBX AREA 6200 73 STREET MIAMI, FLORIDA 33143 KEY PLAN PROJECT -- LOCATION y EXPOSED SIDE STAGGER HORIZ. is VERT. JOINT 2 -0 MIN. BETWEEN BASE AND S TWO LAYERS 5/8" TYPE "X" Comm. No. 40002.000 FACE LAYER GYPSUM BOARD Scale: AS NOTED C -H STUDS -SIZED AND 5/8" TYPE "X" GYPSUQISOARD Date: 12/12/08 GAUGE AS REQUIRED FOR / �� It SOUTF� MlAV,I ,. ,. ,. IV, b Drawn: JCR CONDITIONS 1 TYPE X GYPSUM BOARD BNH STRUCTURA " SECTION CARD File: APPROVED 13 _....... CtATE /Z 'FLIP FLOP' CONFIGURATION SUGGESTED Draw'g Title: WHERE BOTH SIDES EXPOSED (STAIRS) STAGGER HORIZ. & VERT. JOINTS MISCELLANEOUS MIN. ON OPPOSITE SIDES OF PARTITION DETAILS 12 TWO HOUR SHAFT WALLS A -10,1 SCALE 3• -FU C -H SPLINE C -H STUD 1" TYPE "X" GYP BOARD LINER PAN---L 311M ELEVATION 8 TWO DOUR SHAFT WALLS 10.1 1 SCALEII 3• -1'-0" , TEST REF.: U OF C 4 -2 -75 1" TYPE "X" GYPSUM BOAR -__ -- U OF C 6 -23 -75 C -H STUDS -SIZED AND UL DES U438 GAUGE AS REQUIRED FOR CONCEALED SIDE CONDITIONS 6574,:,x+ Revisions: Project Name: SOUTH MIAMI HOSPITAL PBX AREA 6200 73 STREET MIAMI, FLORIDA 33143 KEY PLAN PROJECT -- LOCATION y EXPOSED SIDE STAGGER HORIZ. is VERT. JOINT 2 -0 MIN. BETWEEN BASE AND S TWO LAYERS 5/8" TYPE "X" Comm. No. 40002.000 FACE LAYER GYPSUM BOARD Scale: AS NOTED C -H STUDS -SIZED AND 5/8" TYPE "X" GYPSUQISOARD Date: 12/12/08 GAUGE AS REQUIRED FOR / �� It SOUTF� MlAV,I ,. ,. ,. IV, b Drawn: JCR CONDITIONS 1 TYPE X GYPSUM BOARD BNH STRUCTURA " SECTION CARD File: APPROVED 13 _....... CtATE /Z 'FLIP FLOP' CONFIGURATION SUGGESTED Draw'g Title: WHERE BOTH SIDES EXPOSED (STAIRS) STAGGER HORIZ. & VERT. JOINTS MISCELLANEOUS MIN. ON OPPOSITE SIDES OF PARTITION DETAILS 12 TWO HOUR SHAFT WALLS A -10,1 SCALE 3• -FU