09-57-008DOOR
SCHEDULE
4.5" X 4.5" (HAGER)
NUMBER
TYPE
MATL
SIZE
THICK
FINIS
RATING
HARDWARE
FRAME TYPE
FRAME MATL
FRAME FINISH
JAMB
HEAD
REMARKS
2161
A
WOOD
3' -0" x 7' -0"
1 3/4"
STAIN
US26D
SET 1
1
ALUM
PAINT
3/A-8.0
3/A-8.0
SEE MANUFACTURER FOR HARDWARE
VV A
�o
I �
ra
F_ °1
' -0" KICK
PLATE
1 1 DOOR SCHEDULE
A -8.0 A SCALE: N.T.S.
18 GA 3 5/8" DOUBLE STUDS 0
JAMBS (TYPICAL) W/ 1" X 3"
METAL STRAPS 3 PER JAMB
rr-
X11
5/8" GYPSUM BOARD
JAMB ANCHOR CLIP
WELDED TO FRAME &
FASTENED TO STUDS
(3 PER JAMB) TYPICAL
2"
1 DOOR JAMB DETAIL HEAD SIM.
A -8.0 SCALE: 3" = V -0"
CAULK PERIMETER
BOTH SIDES (TYPICAL)
HOLLOW METAL FRAME
LO
LO
GROUT ALL JAMBS SOLID
TYPE M MORTAR
HARDWARE SETS:
1 1/2 PAIR
HINGE
4.5" X 4.5" (HAGER)
US26D
1 EACH
LOCKSET
ND50PD - RHO (SCHLAGE)
US26D
1 EACH
CLOSER
LCN - 4040
US26D
1 EACH
KICKPLATE
12" X 2" LDW (HAGER)
US26D
3 EACH
SILENCERS
307D (IVES)
GREY
1 EACH
WALLSTOP
FS 13 (IVES)
US26D
FINISH SCHEDULE
WALL
Date:
PAINT
SHERWIN WILLIAMS, HEALTH SPEC, SOFTER TAN, SW6141
FLOOR/ BASE
Checked:
VT1
MATCH ADJACENT
•
r
2x2 ACCOUSTIC
ARMSTRONG ACOUSTICAL CEILING DUNE # 1775 BEVELED TEGULAR EDGE 9/16" EXPOSED TEE SUSPENSION
•
NOTE: FINISHES TO COMPLY WITH NFPA -253 CLASS A FIRE RATING
►w ►• ••• r r •rrr• r••
r • r •r ♦w • • •
••• r • W• W r • r
• r • • i Y • �
•r• i•♦ i W U r••• J
• ••w •WW r • J
•♦•• ••••r ••• r
• •
•••• • i•r•r • ••• ♦'•
MATERIAL AND FINISH
WALL
Date:
PAINT
SHERWIN WILLIAMS, HEALTH SPEC, SOFTER TAN, SW6141
FLOOR/ BASE
Checked:
VT1
MATCH ADJACENT
CEILJNQ
2x2 ACCOUSTIC
ARMSTRONG ACOUSTICAL CEILING DUNE # 1775 BEVELED TEGULAR EDGE 9/16" EXPOSED TEE SUSPENSION
2 FINISH SCHEDULE
A -8.0 SCALE: N.T.S.
xf$N
V ,G s s
yr r
�t
J
ir•w
• R
U
r
•
•v
r"
r
r
r !
BE RMELLO • AJAMIL
& PARTNERS-INC
Architecture Engineering Planning
Interior Design landscape Architecture
2601 So. Bayshore Drive
Suite 1000
Miami, Florida 33133
(305) 859 -2050 FAX (305) 559 -9638
SS'R
Smith, Seckman, Reid, Inc.
CONS;ZJL'TING
]ENGINEIEJE2�
600 Hest Hillsboro, Suite 300
Deerfield Beach, Florida 33441
rhene(954)421 -1260 Fax(954)421 -1466
DONNELL, DUQUESNE t ALBAISA P.A.
CONSULTING ENGINEERS
❑RAMON R, DONNELL P.E. 0011690
CIVUSTRUCCI URAL
❑PEDRO J. DUQUESNE P.E. 0022764
CIVIL /STRUu TURAL
❑AIDA M. ALSAISA P.E. 0045130
..... :rc r.o ::::::::::: 305) S.W. 11 th OT. MIAMI, FLOX A 315
ki.
�A
�011 +1
t
I
Revisions:
I
Project Name:
SOUTH MIAMI
HOSPITAL
PBX AREA
6200 73 STREET
MIAMI, FLORIDA 33143
Comm. No. 40002.000
Scale:
AS NOTED
Date:
12/12/08
Drawn:
JCR
Checked:
BNH
CARD File:
Draw'g Title:
DOOR & FINISH
SCHEDULES