09-314-023
4009 -9201 Notification Appliance Extender Panel #1 - Phase 8 SMH - 2nd FI Electric Closet Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION Standby Standby Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 17 X MAXIMUM VOLTAGE DROP ESTIMATED 4009 -9201 1 1 14009 IDNET NAC EXTENDER, 120 VAC 4009 -9201 1 4009 IDNET NAC EXTENDER, 120 VAC 0.085000 0.085000 4009 -9201 1 1 14009 IDNET NAC EXTENDER, 120 VAC 1 0.085000 1 0.085000 1 0.185000 0.185000 1 0.185000 Peripheral Devices Total Panel Stby 1 0.085000 1 Total Panel Alarm 0.185000 Peripheral Devices 1 2 STROBE ONLY, WAIL, 75CD 0.000000 0.000000 0.186000 Er7GWP 1 I SPEAKER STROBE WP WHEELOCK 0.000000 0.000000 0.138000 0.138000 4906 -9101 1 ISTROBE ONLY MC WALL 75CD 0.000000 0.000000 0.186000 0.186000 EXISTING 1 I EXISONG LOAD 0.000000 0.000000 5.771000 5.771000 0.085 Total Alarm Amps Total Perth Stby 0.000 Total Peri h Alarm 6.095 Standby Total Standby Amps 0.085 Total Alarm Amps 6.280 •Additional Current Draw Included Below With Device Addresses Used 1:N1 -3 Current Standby Control Pone[ Card Power 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. Battery Calculations Battery Calculations Current Power For External Peripheral Devices Current Control Panel Card Power Standby 0.085 Alarm 0.185 < -- Totals - -> Battery Calculations Current Additional Battery Capacity Required OX Current 0.186 0.000 Control Panel Card Power 0.085 4.874 0.185 Additional Battery Capacity Required OX 0.000 Power For External Peripheral Devices 0.00000 Alarm M 6.09500 0.340 Standby M 4.633 0.085 < -- Totals - -> 6.280 Alarm M Additional Battery Capacity Required OX 0.000 4.428 0.000 Standby Time - 4 Hire 0.340 Standby M 75 Degrees Celsius U Alarm Time - 15 Mins. 1.570 Alarm M 75 Degrees Celsius 167 Degrees Fahrenheit Battery Required 2081 -9272 6.2 5.533 Total Ah 4009 -9201 Notification Appliance Extender Panel #2 - Phase 8 SMH -2nd Fl Electric Closet Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION Standby Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment WHEELOCK TOTAL 17 X MAXIMUM VOLTAGE DROP ESTIMATED 4009 -9201 1 1 14009 IDNET NAC EXTENDER, 120 VAC 4009 -9201 1 4009 IDNET NAC EXTENDER, 120 VAC 0.085000 0.085000 0.185000 0.185000 Total Panel Stby Total Panel Stby 0.085000 1 Total Panel Alarm 1 0.185000 Peripheral Devices CIRCUIT CKT. LOAD GAUGE 4906 -9101 4906 -9101 1 2 STROBE ONLY, WAIL, 75CD 0.000000 0.000000 0.186000 0.372000 ET70 WP 1 IWHEATHERPROOF SPEAKER STROBE Er70 0.000000 0.000000 0.138000 0.138000 EXISTING 1 I EXISTING LOAD 0.000000 0.000000 4.179000 4.179000 5.134 Total Peri h Stby 0.000 Total Peri h Alarm 4.689 Total Standby Amps 0.085 Total Alarm Amps 4.874 • Additional Current Draw Included Below With Device Addressee Used 1.791 0 Standby 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. 1. 2 -wire detector alarm current is included In the alarm current of the Initiating Device Circuit. 1.184 Battery Calculations Current 1:N1 -3 Current Standby Control Pone[ Card Power Alarm Battery Calculations Battery Calculations Current Power For External Peripheral Devices Current Control Panel Card Power Control Panel Card Power 0.085 0.185 0.185 < -- Totals - -> Power For External Peripheral Devices 0.00000 Additional Battery Capacity Required OX 4.68900 0.186 0.000 0.085 < -- Totals - -> 4.874 Standby Ah Additional Battery Capacity Required OX 0.000 Alarm Time - 15 Mins. 0.000 Alarm M Standby Time - 4 Hire 0.340 Standby M 4.633 Total Ah Alarm Time - 15 Mins. 1.219 Alarm M Battery Required 2081 -9272 6.2 Battery Required 2081 -9272 8.2 4.428 Total Ah 4009 -9201 Notification Appliance Extender Panel #3 - Phase 8 SMH - 4th Fi Electric Closet Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION Standby Total Alarm Total Module Qty Description Current Standby Current Alarm Panel Equipment 4908 -9101 WHEELOCK TOTAL 17 X MAXIMUM VOLTAGE DROP ESTIMATED 4009 -9201 1 1 14009 IDNET NAC EXTENDER, 120 VAC 0.085000 0.085000 0.185000 0.185000 ACTUAL Total Panel Stby 0.085000 Total Panel Alarm 0.185000 Peripheral Devices VOLTAGE CIRCUIT CKT. LOAD GAUGE 4906 -9101 1 2 ISTROBE ONLY, MC, WALL 75CD 0.000000 0.000000 0.186000 0.372000 EXISTING 1 I EXISTING LOADS 0.000000 0.000000 4.577000 4.577000 EXISTING Total Peri h Stbyl 0.000 1 Total Peri h Alarm 4.949 Total Standby Amps 0.085 Total Alarm Amps 5.134 •Additional Current Draw Included Below With Device Addresses Used Total Peri h Alarm 6.701 Total Standby Amps 0.085 1. 2 -wire detector alarm current is included in the alarm current of the initiating Device Circuit. 6.888 • Additional Current Draw Included Below With Device Addresses Used 1 1.791 0 Standby 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. Alarm 1.184 Battery Calculations Current 1:N1 -3 Current RVISUAL Control Pone[ Card Power 0.085 Battery Calculations 0.185 1.990 Power For External Peripheral Devices 0.00000 Control Panel Card Power 4.94900 286 ft 0.185 0.085 < -- Totals - -> 5.134 1 0 Additional Battery Capacity Required OX 0.000 0.186 0.000 < -- Totals - -> Standby Time - 4 Hire 0.340 Standby Ah 0.000 4.949 Alarm Time - 15 Mins. 1.284 Alarm M 0.340 Standby M Battery Required 2081 -9272 8.2 4.633 Total Ah 1.722 Alarm M 4009 -9201 Notification Appliance Extender Panel #4 - Phase 8 SMH - 5th Fl Electric Closet Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION Standby Total Alarm Total Module qty Description Current Standby Current Alarm Panel Equipment 4908 -9101 WHEELOCK TOTAL 17 X MAXIMUM VOLTAGE DROP ESTIMATED 4009 -9201 1 1 14009 IDNET NAC EXTENDER, 120 VAC 0.085000 0.085000 0.185000 0.185000 ACTUAL Total Panel Stby 0.085000 Total Panel Alarm 0.185000 Peripheral Devices VOLTAGE CIRCUIT CKT. LOAD GAUGE 4906 -9101 1 2 ISTROBE ONLY, MC, WALL, 75CD 0.000000 0.000000 0.186000 0.372000 EXISTING 1 I EXISTING LOADS 0.000000 0.000000 3.781000 3.781000 EXISTING Total Peri h Stby 0.000 Total Peri h Alarm 4.153 Total Standby Amps 0.085 Total Alarm Amps 4.338 • Additional Current Draw Included Below With Device Addresses Used Total Peri h Alarm 6.701 Total Standby Amps 0.085 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. 6.888 • Additional Current Draw Included Below With Device Addresses Used 1 1.791 0 Standby 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. Alarm 1.184 Battery Calculations Current 1:N1 -3 Current RVISUAL Control Panel Card Power 0.085 Battery Calculations 0.185 1.990 Power For External Peripheral Devices 0.00000 Control Panel Card Power 4.15300 286 ft 0.185 0.085 < -- Totals - -> 4.338 1 0 Additional Battery Capacity Required OX 0.000 0.186 0.000 < -- Totals - -> Standby Time - 4 Hire 0.340 Standby M 0.000 4.949 Alarm Time - 16 Mins. 1.085 Alarm M 0.340 Standby M Battery Required 2081 -9272 6.2 4.006 Total Ah 1.722 Alarm M 4009 -9201 Notification Appliance Extender Panel #5 - Phase 8 SMH - 6th Fl Electric Closet Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION Standby Total Alarm Total Module qty Description Current Standby Current Alarm Panel Equipment 4908 -9101 WHEELOCK TOTAL 17 X MAXIMUM VOLTAGE DROP ESTIMATED 4009 -9201 1 1 1009 IDNET NAC EXTENDER, 120 VAC 0.085000 0.085000 0.185000 0.185000 ACTUAL Total Panel Stby 1 0.085000 Total Panel Alarm 0.185000 Peripheral Devices VOLTAGE CIRCUIT CKT. LOAD GAUGE 4906 -9151 1 1 SPEAKER STROBE MC 75CD WALL RED 0.000000 0.000000 0.186000 0.186000 4908 -9101 1 4 ISTROBE ONLY, WAIT. 75CO 0.000000 0.000000 0.186000 0.744000 EXISTING 1 1 EXSISTING LOADS 0.000000 0.000000 5.771000 5.771000 1.990 Total Peri h Stby 0.000 Total Peri h Alarm 6.701 Total Standby Amps 0.085 Total Alarm Amps 6.888 • Additional Current Draw Included Below With Device Addresses Used 1 1.791 0 1.929 1. 2 -wire detector alarm current is included in the alarm current of the Initiating Device Circuit. 5.81X 1.184 0.6 Ohms 296 fL 1:N1 -3 Standby RVISUAL Alarm 0 Battery Calculations Current 1.990 Current 8.98X Control Panel Card Power 0.085 286 ft 0.185 2nd FLOOR EAST WING Power For External Peripheral Devices 0.00000 1 0 6.70100 1 1 0.186 0.085 < -- Totals - -> 6.886 1 0.9 Ohms Additional Battery Capacity Required OX 0.000 4.949 0.000 1 1 Standby rime - 4 Hire 0.340 Standby M METHOD USED TO CALCULATE VOLTAGE DROP: 1 6 1 Alarm rime - 15 Mine. 1.722 Alarm M t? Battery Required 2081 -9272 6.2 6.009 Total Ah %'vm IF?"& (u4cmR 9M \SMI ►TASTER SrT FAST MWR Perm PEV02 9- 74 -a7.rMC DATI: CREATED: November S. 2007 DATE PLOTTED: November a. 2007 DATE SAVED: Nov mAx a 2007 4009 -9201 Notification Appliance Extender Panel #1 - Phase 8 SMH - 2nd F1 Electric Closet Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION EXISTING V/0 0/P NAC SCHEDULE / VOLTAGE DROP CALCULATION WALL EXISTING V/0 DROP TOTALS VOLTAGE DROP TOTALS 4908 -9101 WHEELOCK TOTAL 17 X MAXIMUM VOLTAGE DROP ESTIMATED ET70WP LOADS 4906 -9101 TOTAL HIRE ACTUAL ACTUAL TOTAL MAXIMUM CIRCUIT OUTPUT VOLTAGE - 20.4 FOR CALCULATION CIRCUIT CIRCUIT WP VOLTAGE CIRCUIT CKT. LOAD GAUGE VOLTAGE VOLTAGE CIRCUIT ALLOWABLE CIRCUIT DESCRIPTION TYPE LENGTH 0.138 1.000 0.188 AMPS 18, 16, 14, 12 DROP X DROP VOLTS RESISTANCE CKT. LENGTH 1:N1 -1 2nd FLOOR NW WING RVISUAL 100 ft 0 1.990 0 1.990 14 5.99X 1.222 0.6 Ohms 286 ft 1:N1 -2 2nd FLOOR SW WING RVISUAL 100 tL 1 1.791 0 1.929 14 5.81X 1.184 0.6 Ohms 296 fL 1:N1 -3 2nd FLOOR EAST WING RVISUAL 150 ft 0 1.990 0 1.990 14 8.98X 1.833 0.9 Ohms 286 ft 1:N1 -4 2nd FLOOR EAST WING RVISUAL 150 ft 1 0 0.000 1 1 0.186 1 14 1 0.84X 1 0.171 1 0.9 Ohms 1 3,065 ft 2 4.949 Total Load (AMPS) 1 1 4.689 [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] METHOD USED TO CALCULATE VOLTAGE DROP: 1 6 1 6.095 6.701 t? [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] Wire Resistance At Wire Resistance At O J Wire Resistance At 75 Degrees Celsius U CO W 75 Degrees Celsius 167 Degrees Fahrenheit z 0 W Ohms / ft 167 Degrees Fahrenheit Ohms / ft O U � t OGA - 0.001210 Ohms / ft 10GA = 0.001210 0 F- U rz W 12GA = 0.001930 O 1DGA = 0.001210 12GA - 0.001930 14GA - 0.003070 12GA = 0.001930 14GA = 0.003070 16GA = 0.004890 _O CrN U 14GA = 0.003070 16GA - 0.004890 18GA - 0.007770 W � J U W$ 16GA - 0.004890 WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WIRE) 18GA = 0.007770 WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WD3E W W IY LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WIRE) NOTE: W LL OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN NOTE: LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN w w ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOiIS FOR A SMALL MARGIN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN a LENGTH, CONTACT YOUR LOCAL SIMPLEXGRINNELL DISTRICT OFFICE. IS OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT CTI( W 4 9F- ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT LENGTH, CONTACT YOUR LOCAL SWLEXGRINNELL DISTRICT OFFICE. o a LENGTH, CONTACT YOUR LOCAL SD[PLEXGRINNELL DISTRICT OFFICE. LENGTH, CONTACT YOUR LOCAL Sn&LEXGRINNELL DISTRICT OFFICE. 4009 -9201 Notification Appliance Extender Panel #2 - Phase 8 SMH - 3rd Fl Electric C1os1t LIANCE UANTTT1ES CURRENT DRAW 0 18 VDC Closet 6th Fl W NAC SCHEDULE / VOLTAGE DROP CALCULATION EXISTING V/0 0/P VOLTAGE DROP TOTALS V/0 VOLTAGE DROP TOTALS 17 X MAXIMUM VOLTAGE DROP ESTIMATED LOADS 4908 -9101 WHEELOCK TOTAL WIRE ACTUAL ACTUAL TOTAL MAXIMUM CIRCUIT OUTPUT VOLTAGE - 20.4 FOR CALCULATIONS CIRCUIT CIRCUIT TOTAL MAXIMUM S/S CKT. LOAD GAUGE 1(18, VOLTAGE VOLTAGE CIRCUIT ALLOWABLE CIRCUIT DESCRIPTION TYPE LENGTH 1 0.186 0.138 AMPS le, 14, 12 DROP X DROP VOLTS RESISTANCE CKT. LENGTH 2:N1 -1 3rd FLOOR NW WING RVISUAL 100 ft 0.995 1 0 1.181 14 3.55X 0.725 0.6 Ohms 483 (t 2:N1 -2 3rd FLOOR SW WING RVISUAL 100 ft. 1.393 0 0 1.393 14 4.19X 0.855 0.6 Ohms 409 ft 2:N1 -3 3rd FLOOR EAST WING RVISUAL 150 ft. 1.791 0 0 1.791 14 8.09X 1.650 0.9 Ohms 318 ft 2:N1 -4 3rd FLOOR STROBES RVISUAL 150 ft 0.000 1 1 1 0.324 1 14 1 1.46% 1 0.298 0.9 Ohms 1,759 ft. 1.791 1 14 Total Load (AMPS) 2.199 METHOD USED TO CALCULATE VOLTAGE DROP: 5 2 4.949 METHOD USED TO CALCULATE VOLTAGE DROP: 4 2 1 1 4.689 [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] METHOD USED TO CALCULATE VOLTAGE DROP: 1 1 8 [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / Fn] 6.701 t? Wire Resistance At Wire Resistance At Wire Resistance At O J 75 Degrees Celsius 75 Degrees Celsius U CO W 167 Degrees Fahrenheit 167 Degrees Fahrenheit z 0 W Ohms / ft Ohms / ft Ohms / ft O U � t OGA - 0.001210 10GA = 0.001210 10GA = 0.001210 0 F- U rz W 12GA = 0.001930 O 12GA = 0.001930 12GA - 0.001930 14GA - 0.003070 14GA = 0.003070 14GA = 0.003070 16GA = 0.004890 _O CrN U 16GA = 0.004890 16GA - 0.004890 18GA - 0.007770 W � J U W$ 18GA = 0.007770 WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WIRE) NOTE: WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WD3E W W IY LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN NOTE: NOTE: W LL OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN w w ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN a LENGTH, CONTACT YOUR LOCAL SIMPLEXGRINNELL DISTRICT OFFICE. IS ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT 4009 -9201 Notification Appliance Extender Panel #3 - Phase 8 SMH - 4th Fl Electric Closet Closet 6th Fl W - W I- NAC SCHEDULE / VOLTAGE DROP CALCULATION EXISTING V/0 VOLTAGE DROP TOTALS TOTALS VOLTAGE DROP TOTALS I� 17 X MAXIMUM VOLTAGE DROP ESTIMATED LOADS 4906 -9101 TOTAL WIRE ACTUAL ACTUAL TOTAL MAXIMUM CIRCUIT OUTPUT VOLTAGE - 20.4 FOR CALCULATIONS CIRCUIT CIRCUIT TOTAL MAXIMUM CKT. LOAD GAUGE VOLTAGE VOLTAGE CIRCUIT ALLOWABLE CIRCUIT DESCRIPTION TYPE LENGTH 1.000 0.188 AMPS 18, 18, 14, 12 DROP X DROP VOLTS RESISTANCE CKT. LENGTH 3:N1 -1 4th FLOOR NW WING RVISUAL 100 ft 0.995 1 1.181 14 3.55% 0.725 0.6 Ohms 483 ft 3:N1 -2 4th FLOOR SW WING RVISUAL 100 ft 1.791 0 1.791 14 5.39X 1.100 0.6 Ohms 318 ft 3:N1 -3 4th FLOOR EAST WING RVISUAL 150 ft. 1.393 1 1 1.579 14 7.13X 1.454 0.9 Ohms 361 ft 3 :N1 -4 4th FLOOR CENTER WING RVISUAL 100 ft. 1 0.398 1 0 0.398 1 14 1 1.20X 1 0.244 1 0.6 Ohms 1 1,432 ft. 1 0 1 1.791 Total Load (AMPS) 1.791 1 14 1 10.78X 2.199 METHOD USED TO CALCULATE VOLTAGE DROP: 5 2 4.949 Total Load (AMPS) ELU) [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] METHOD USED TO CALCULATE VOLTAGE DROP: 1 1 8 1 4 6.701 t? Wire Resistance At Wire Resistance At � IY O J 75 Degrees Celsius 75 Degrees Celsius U CO W 167 Degrees Fahrenheit 167 Degrees Fahrenheit z 0 W Ohms / ft Ohms / ft O U � 10GA = 0.001210 10GA = 0.001210 0 F- U rz W O 12GA = 0.001930 12GA - 0.001930 14GA = 0.003070 14GA = 0.003070 _O CrN U 16GA = 0.004890 16GA - 0.004890 W � J U W$ 18GA = 0.007770 18GA = 0.007770 WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WIRE WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WD3E W W IY NOTE: NOTE: W LL LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN w w OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN a IS ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT CTI( W 4 9F- LENGTH, CONTACT YOUR LOCAL SUMLEXGRINNELL DISTRICT OFFICE. LENGTH, CONTACT YOUR LOCAL SWLEXGRINNELL DISTRICT OFFICE. o a 4009 -9201 Notification Appliance Extender Panel #4 - Phase 8 SMH - 5th Fl Electric Closet Closet 6th Fl W - W I- NAC SCHEDULE / VOLTAGE DROP CALCULATION EXISTING V/0 EXISTING VOLTAGE DROP TOTALS VOLTAGE DROP TOTALS I� 17 X MAXIMUM VOLTAGE DROP ESTIMATED LOADS 4906 -9101 TOTAL WIRE ACTUAL ACTUAL TOTAL MAXIMUM CIRCUIT OUTPUT VOLTAGE - 20.4 FOR CALCULATIONS CIRCUIT CIRCUIT TOTAL MAXIMUM CKT. LOAD GAUGE VOLTAGE VOLTAGE CIRCUIT ALLOWABLE CIRCUIT DESCRIPTION TYPE LENGTH 1.000 0.188 AMPS 18, 16, 14, 12 DROP X DROP (VOLTS) RESISTANCE CKT. LENGTH 4:N1 -1 5th FLOOR NW WING RVISUAL 100 ft. 0.995 1 1.181 14 3.55% 0.725 0.6 Ohms 483 ft 4:N1 -2 5th FLOOR SW WING RVISUAL 100 ft 0.995 0 0.995 14 2.99% 0.611 0.6 Ohms 573 ft 4:N1 -3 5th FLOOR EAST WING RVISUAL 150 ft 1.393 1 1.579 14 7.13% 1.454 0.9 Ohms 361 ft 4:N1 -4 5th FLOOR CENTER WING RVISUAL 100 ft. 1 0.398 1 0 0.398 1 14 1 1.20X 1 0.244 1 0.6 Ohms 1,432 ft 1 0 1 1.791 Total Load (AMPS) 1.791 1 14 1 10.78X 2.199 METHOD USED TO CALCULATE VOLTAGE DROP: 4 1 2 1 4.153 Total Load (AMPS) ELU) [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] METHOD USED TO CALCULATE VOLTAGE DROP: 1 1 8 1 4 6.701 t? Wire Resistance At � IY O J 75 Degrees Celsius U CO W 167 Degrees Fahrenheit z 0 W Ohms / ft O U � Ita 0 U 10GA = 0.001210 0 F- U rz W O 12GA - 0.001930 rZ 14GA = 0.003070 _O CrN U Lail 16GA - 0.004890 W � J U W$ 18GA = 0.007770 WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WD3E W W IY NOTE: W LL LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN w w OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN a IS SSa. U1sD ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT CTI( W 4 9F- LENGTH, CONTACT YOUR LOCAL SWLEXGRINNELL DISTRICT OFFICE. o a 4009 -9201 Notification Appliance Extender Panel #5 - Phase 8 SMH - Electric Closet 6th Fl W - W I- NAC SCHEDULE / VOLTAGE DROP CALCULATION S/S EXISTING V/0 VOLTAGE DROP TOTALS I� 17 X MAXIMUM VOLTAGE DROP ESTIMATED 4906 -9151 LOADS 4901 -9101 TOTAL WIRE ACTUAL ACTUAL TOTAL MAXIMUM CIRCUIT OUTPUT VOLTAGE - 20.4 FOR CALCULATIONS CIRCUIT CIRCUIT !K- CKT. LOAD GAUGE VOLTAGE VOLTAGE CIRCUIT ALLOWABLE CIRCUIT DESCRIPTION TYPE LENGTH 0.186 1.000 0.188 AMPS 18, 18, 14, 12 DROP X DROP VOLTS RESISTANCE CKT. LENGTH 5:Ni -1 6TH FLOOR NW WING RVISUAL 100 ft 0 1.194 2 1.566 14 4.71X 0.962 0.6 Ohms 364 ft 5:N1 -2 6TH FLOOR SW YANG RVISUAL 100 ft 0 1.194 1 1.380 14 4.15% 0.847 0.6 Ohms 413 ft 5:N1 -3 6TH FLOOR EAST WING RVISUAL 100 ft I 1 1 1.592 1 1.964 14 5.91% 1.206 0.6 Ohms 290 ft 5 :N1 -4 7TH do 8TH LEVEL RVISUAL 200 ft 1 0 1 1.791 1 0 1.791 1 14 1 10.78X 2.199 1.2 Ohms 318 ft Total Load (AMPS) ELU) METHOD USED TO CALCULATE VOLTAGE DROP: 1 1 8 1 4 6.701 t? [(CIRCUIT LENGTH IN FEET X 2) (AMPS) (OHMS / FT)] � IY O J Wire Resistance At U CO W 75 Degrees Celsius z 0 W 187 Degrees Fahrenheit O U � Ita 0 U Ohms / ft 0 F- U rz W O 10GA - 0.001210 rZ 12GA = 0.001930 _O CrN U Lail 14GA = 0.003070 W � J U W$ 16GA = 0.004890 18GA = 0.007770 W W IY WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE UNCOATED SOLID COPPER WIRE) W LL NOTE: w w LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN a IS SSa. U1sD OF SAFETY, TAKING INTO CONSIDERATION THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN CTI( W 4 9F- ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXDLUM ALLOWABLE CIRCUIT o a LENGTH, CONTACT YOUR LOCAL Sn&LEXGRINNELL DISTRICT OFFICE. FhZE ALARM SYSTEM TO BE 1NSIALLED IN ACCORDANCE WITH NFPA 72; 70;101- P012M.9' "'V MUM-DADE COUNTY FIRE DEPAFtTA'iEN T BILDG. PERUIT FIRE ALUM-1Z FIRE SUPPRESSION WATER MAIN EXT. DATE BATTERY CALCS SCALE: NTS UL. TR/ANA &ASSOCIATES, INC. CONSULTING. ENGINEERS CERTIFICATE OF�AU•T,FJQJ"h9N: 26644 5151 S.W.. 98th AVE' J' •., MIAMI, FLORIE 33 6 ' ` o� �r �A LEA;[•' Florida Regl§iF&�tbr) Flo. f3�6 707 �a W - W I- I� I z 0 W !K- IM L Q ry arn W CV T' a m 0- N LL Cq C9 P 0 'IT Q z W U In LD � 0) p z .� U) CD 0 W a. •� C)�dW a. V z W �q) L ' w � U) (L v 1 m J � J �JJ W > Z Zw © �U) ww ELU) EL �E t? � IY O J U CO W z 0 W O U � Ita 0 U 0 F- U rz W O rZ U _O CrN U Lail W � J U W$ W W IY W LL w w a IS SSa. U1sD T n 0& INSTR CTI( W 4 9F- o a O z . N U U W m o rn >. co 0 U rn rn g z o Em X9 23 < < a O � Z �j rA rA W W W z W O C14 U O z g J F< z Of X w � z J D- 0 z < U J 0 U U W 63 �i a m W LL WW a 0 W W a5 a. rI w a -+--� T►4 a X < O� WO ►- o z2 00 W _ (LS • z Z a. �i--� .^ Cd Z J F<- J P-4 U U W_ V1 0 0 U J 0 z 12V -r-4 I-�- -1 Q W z rH M O z J X 111 J W co co O a a. Er � � m 0 0 w 5 0 Vi .a zg> za a O (d; 90Of (rZ r�,U]W I~rn oaa 30 DRAWN BY: DATE: RC 7 -31 -07 DESIGNED BY: DATE: APPROVED BY: DATE: PROJECT NUMBER: 263-403461/929372021 SHEET TITLE/ PATH: 2003\SOUTHMIAM [HOSPITAL \S MHET RENOVATION SHEET NUMBER: FA -15 VIE' o (24•x24;