09-252-014
16 15 1 14 13 RACEWAYS AND WIRING L H❑MERUN TO PANELBOARD, "L43" INDICATES' PANEL, "1,3" INDICATES CIRCUIT L43 -1,3 NUMBERS, (20A, 1P, UNLESS INDICATED OTHERWISE) NUMBER OF SLASH MARKS INDICATE NUMBER OF #12AWG CONDUCTORS IN MINIMUM 3/4 "C, NO SLASH MARKS INDICATE 2 #12 & 1 #12G -3/4 "C UNLESS INDICATED OTHERWISE NOTES: 1, GREEN GROUND CONDUCTOR NOT INDICATED BUT SHALL BE INCLUDED IN EACH RACEWAY. SIZE SHALL BE #12AWG UNLESS INDICATED OTHERWISE, 2, HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE (3) PHASE CONDUCTORS (ONE PER PHASE) PLUS NEUTRAL AND GROUND CONDUCTORS IN EACH CONDUIT, K 16 FEEDER TAG - REFER TO LEGEND OF FEEDER SIZES LIGHTING FIXTURES J I -F I I FIXTURE DESIGNATION A FLUORESCENT FIXTURE 2 a �— LOWER CASE LETTER INDICATES CONTROL CIRCUIT SWITCH LEG CIRCUIT NUMBER I FLUORESCENT BARE LAMP STRIP OR INDUSTRIAL STRIP F2 FLUORESCENT UNDERCOUNTER TASK LIGHT O INCANDESCENT OR COMPACT FLUORESCENT RECESSED OR SURFACE MOUNTED LIGHTING FIXTURE IB WALL MOUNTED LIGHTING FIXTURE e WALL WASH OR DIRECTIONAL LIGHTING FIXTURE CEILING MOUNTED ILLUMINATED EXIT SIGN, ARROWS AS INDICATED ON DRAWINGS p� WALL MOUNTED ILLUMINATED EXIT SIGN [—I EMERGENCY BATTERY UNIT WL WARNING LIGHT - EXISTING F1 ARROW INDICATES TYPICAL LIGHTING FIXTURES IN CONTINUOUS ROW, FURNISH AND C� INSTALL ALL CORNERS, ENDCAPS, EXTENSIONS AND FITTINGS AS RQUIRED FOR A COMPLETE INSTALLATION TOGGLE SWITCHES (MOUNTED 48' AFF) SA SINGLE POLE TOGGLE SWITCH. 'a" INDICATES FIXTURE CONTROL S2 DOUBLE POLE, DOUBLE THROW CENTER OFF TOGGLE SWITCH, HUBBELL SERIES 1382 S3 THREE WAY TOGGLE SWITCH SP SINGLE POLE TOGGLE SWITCH WITH PILOT LIGHT FD_11 INCANDESCENT DIMMER SWITCH, 'D1" INDICATES 1000 WATT DIMMER, "D2" INDICATES 2000 WATT DIMMER, RECEPTACLES (MOUNTED 18' AFF) 21_2 DUPLEX RECEPTACLE, 'R21' INDICATES PANEL, "2" INDICATES CIRCUIT NUMBER, 'E' INDICATES WIRED TO EMERGENCY PANEL m DUPLEX RECEPTACLE MOUNTED BELOW COUNTER, COORDINATE PROPER LOCATION 71 WITH ARCHITECTURAL DWGS, DOUBLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE MOUNTED 6" ABOVE COUNTER TOP, GFI DUPLEX RECEPTACLE WITH INTERGRAL GROUND FAULT INTERRUPTER ETR EXISTING TO REMAIN GFI DUPLEX RECEPTACLE WITH INTERGRAL GROUND FAULT INTERRUPTER MOUNTED 6" ABOVE COUNTER TOP ® DUPLEX RECEPTACLE FLOOR MOUNTED SPECIAL PURPOSE RECEPTACLE TWO DUPLEX RECEPTACLES MOUNTED AT 18" AFF AND 24" AFF q) SINGLE RECEPTACLE NEMA 5 -20R TELECOMMUNICATI ❑NS (MOUNTED BELOW COUNTER 0 COMBINATION TELEPHONE/DATA OUTLET 'TN1 RJ45 TYPE ETHERNET 100/1000 MBIT NETWORK CONNECTOR, ACCESS TO CUSTOMER'S NETWORK VIA THEIR REMOTE ACCESS SERVER IS NEEDED FOR REMOTE SERVICE NETWORK (RSR) CONNECTIVITY, 7N2 RJ45 TYPE ETHERNET 100/1000 MBIT NETWORK CONNECTOR, (1000 MBIT RECOMMENDED) WITH ACCESS TO CUSTOMER'S NETWORK, LOCATE WITHIN 10' ❑F NETWORK CARD, NETWORK FIBER OPTIC AND ETHERNET CABLING, CONNECTORS WALL BOXES, PATCH PANELS, ETC, ARE THE RESPONSIBILITY OF THE PRURCHASER, ve RJ45 TYPE ETHERNET 100/1000 MBIT NETWORK CONNECTOR WITH INTERNET ACCESS FOR PHILLIPS FIELD SERVICE ENGINEER C❑NNCTIVITY TO ON -LINE SYSTEM D❑CUMANTATION, 7V1 VOICE NURSE CALL BED INTERFACE OUTLET NOTE, ALL OUTLET BOXES SHALL HAVE 3/4" CONDUIT STUBBED 6" ABOVE CEILINGS WITH BUSHING, BRANCH CIRCUIT WIRING N❑TESI I. WINIINU 1J JI>HUwN UN LIKAWINVS LINLY F LIK SPECIFIC ROUTES OR SPECIAL CONDITIONS 2, WIRING AND CONDUIT SHALL BE REQUIRED BETWEEN ALL OUTLETS INDICATED WITH CIRCUIT NUMBERS AND PANEL DESIGNATI ❑NS 3, ALL SWITCH CONTROLS SHALL BE PROVIDED WITH WIRING AND CONDUIT AS REQUIRED 4, ALTHOUGH ALL BRANCH CIRCUIT WIRING AND CONDUIT IS NOT SHOWN, IT IS THE INTENT OF THESE DOCUMENTS THAT A COMPLETE BRANCH CIRCUIT WIRING SYSTEM BE INSTALLED 5, A GREEN GROUNDING CONDUCTOR SHALL BE RUN WITH ALL CIRCUITS, VERIFY CONDUIT SIZE TO ENSURE IT CAN ACC ❑M ❑DATE ALL PHASE, NEUTRAL AND GROUND CONDUCTORS. 12 10 0 7 1 6 ABBREVIATI ❑NS A POWER DISTRIBUTION AF 120 1 PHASE 2 OR AFF - 120/208 VOLT 3 PHASE 4 WIRE PANEL BOARD AFC] AIC AL POWER DISTRIBUTES EQUIPMENT ARCH 0 6*V MCRa 0 W AT ® DISTRIBUTI ❑N PANEL WP ADA COMPLIANT AUDI❑ /VISUAL ALARM MOUNTED 80" AFF. "V" INDICATES VISUAL STAFF EMERGENCY STATI ❑N ATS XFMR PANELBOARD, SURFACE MOUNTED WL PHOT ❑ELECTRIC SMOKE DETECTOR ETR A W G = PANELBOARD, FLUSH MOUNTED NURSE CALL REMOTE LOCATOR RECEIVER, SUBCONTRACTOR, WIRED BY THE ELECTRICAL SUBCONTRACTOR Al BLDG JO JUNCTI ❑N BOX, SIZED PER NEC TOILET EMERGENCY STATION F. PROVIDE A #10 GREEN INSULATED CONTINUOUS COPPER CONDUCTOR IN 1 /2 "CONDUIT TO BOND ALL WIREWAYS SNC C DL MOTOR, "2" INDICATES HORSEPOWER N " GENERAL ELECTRICAL NOTES CORRID ❑R DOME LIGHT WALL MOUNTED C. B. ® MAGNETIC MOTOR STARTER . w w O z =� REQUIRED BY NFPA 99, SECTION 4.3.3. RECORD THE RESULTS AND MAKE THEM AVAILABLE TO THE NURSE CALL EQUIPMENT CABINET C,T, SM MANUAL MOTOR STARTER WITH THERMAL ❑VERLA ❑D, "P" INDICATES PILOT LIGHT 1. E6P N ❑N -FUSED DISCONNECT SWITCH, SIZE AS REQUIRED, "6P" INDICATES 6 POLE CAT FUSED DISCONNECT SWITCH, SIZE OF SWITCH AND FUSE AS REQUIRED CIR COL C❑MBINATI ❑N MAGNETIC STARTER AND FUSED DISCONNECT SWITCH, SIZE OF CLIENT CODE /FILE STARTER, SWITCH AND FUSE AS REQUIRED CU ❑T DRY -TYPE DISTRIBUTI ❑N TRANSFORMER, Q 3. DWG LINE LINE POWER DIAGRAM SHALL NOT BE USED AT THE EXTERIOR OF A BUILDING OR AT LOCATIONS E �- LOAD -BREAK SWITCH SUBJECT TO SEVERE CORROSION. EC FUSE, SIZE AS INDICATED 4. VWV EM TRANSFORMER, SIZE AS INDICATED W /THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES ARCHITECT F CIRCUIT BREAKER LICENSE # AR92624 FT }- DRAW -OUT CIRCUIT BREAKER G KIRK -KEY INTERLOCK KCMIL 6. CURRENT TRANSFORMER KVA POTENTIAL TRANSFORMER KVAR SOLID STATE TRIP UNIT KW NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. GROUND MCB AO AMMETER AS REQUIRED BY THE LATEST EDITION OF THE N.E.C. MCC A� AMMETER SWITCH 8. LOAD DATA IS BASED ON INFORMATION PROVIDED BY OWNER AT TIME OF MISC VOLTMETER DESIGN, VERIFY ALL EQUIPMENT AND PANEL SIZES. ML❑ © VOLTMETER SWITCH NC LABELS, WHERE APPLICABLE. UPS DISCONNECT Al 10. NEC PLUG -IN BUSWAY NIL FEEDER BUSWAY NO TB CABLE TAP BOX NTS OPERATIVE, AND ACCEPTANCE BY OWNER MUST BE A CONDITION OF THE CONTRACT. PLUG -IN BUSWAY CIRCUIT BREAKER 0 T2 DRY TYPE TRANSFORMER, "2" INDICATES SIZE, REFER TO DRY TYPE P TRANSFORMER SCHEDULE OF THE LOCAL POWER AND LIGHT COMPANY AND THE LOCAL TELEPHONE P. T, KT2 "K" FACTOR DRY TYPE TRANSFORMER, '2' INDICATES SIZE, REFER TO "K" COMPANY. FACTOR DRY TYPE TRANSFORMER SCHEDULE PVC 12. R MISCELLANE ❑US 420 LINCOLN ROAD, SUITE 258 S EDH ELECTRIC DUCT HEATER, FURNISHED AND INSTALLED BY HVAC SUBCONTRACTOR, SCR WIRED BY ELECTRICAL SUBCONTRACTOR 305- 673 -0004 SP 4 CODE BLUE STATION SW 4] MUSHROOM TYPE PUSHBUTTON STATION FOR ACTIVATION OF SHUNT -TRIP DEVICE TEL ON AIR CONDITIONING SYSTEM AS SHOWN ON PLANS. CONTROLS ARE TO BE UG ST MOTOR RATED SWITCH V Y ❑IRE ALARM SYSTEM 0 6*V MCRa 0 FIRE ALARM CONTROL PANEL SYMB ❑L LIST MOUNTING HEIGHTS SHALL BE AS INDICATED UNLESS SHOWN OTHERWISE ON ELECTRICAL DRAWINGS OR ARCHITECTURAL ELEVATI ❑NS AMPERES AMPERE FRAME (CIRCUIT BREAKER RATING) ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM ARCHITECT AMPERE TRIP (CIRCUIT BREAKER RATING) AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GUAGE BUILDING CONDUIT CIRCUIT BREAKER CURRENT TRANSFORMER CATALOG CIRCUIT COLUMN COPPER DELTA DRAWING WIRED ON EMERGENCY CIRCUIT EMPTY CONDUIT EMERGENCY FLUSH FEET GROUND ONE THOUSAND CIRCULAR MILS KILOVOLT- AMPERES KIL ❑VOLT- AMPERES REACTIVE KIL ❑WATTS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MISCELLANE ❑US MAIN LUGS ONLY N❑RMALLT CLOSED NATIONAL ELECTRICAL CODE NIGHT LIGHT NORMALLY OPEN NOT TO SCALE PHASE PETE POTENTIAL TRANSFORMER POLYVINYL CHL ❑RIDE RECESSED SURFACE SHORT CIRCUIT INTERRUPTING RATING SPARE SWITCH TELEPHONE UNDERGROUND VOLT WYE WATT WEATHERPROOF TRANSFORMER WARNING LIGHT EXISTING TO REMAIN GROMMET CABLE OPENING UPS DISCONNECT VOICE STAFF NURSE CALL DOME LIGHT W MANUAL PULL STATION MOUNTED 48" AFF 5 -B WP ADA COMPLIANT AUDI❑ /VISUAL ALARM MOUNTED 80" AFF. "V" INDICATES VISUAL STAFF EMERGENCY STATI ❑N UNIT ONLY XFMR NON ADA COMPLIANT AUDIO /VISUAL ALARM MOUNTED 80" AFF WL PHOT ❑ELECTRIC SMOKE DETECTOR ETR WS TAMPER SWITCH FURNISHED AND INSTALLED BY THE FIRE PROTECTION NURSE CALL REMOTE LOCATOR RECEIVER, SUBCONTRACTOR, WIRED BY THE ELECTRICAL SUBCONTRACTOR Al WATER FLOW SWITCH FURNISHED AND INSTALLED BY THE FIRE PROTECTION V1 SUBCONTRACTOR, WIRED BY THE ELECTRICAL SUBCONTRACTOR, TOILET EMERGENCY STATION F. PROVIDE A #10 GREEN INSULATED CONTINUOUS COPPER CONDUCTOR IN 1 /2 "CONDUIT TO BOND ALL WIREWAYS SNC DUCT MOUNTED SMOKE DETECTOR DL FIRE ALARM CONTROL PANEL SYMB ❑L LIST MOUNTING HEIGHTS SHALL BE AS INDICATED UNLESS SHOWN OTHERWISE ON ELECTRICAL DRAWINGS OR ARCHITECTURAL ELEVATI ❑NS AMPERES AMPERE FRAME (CIRCUIT BREAKER RATING) ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE INTERRUPTING CAPACITY ALUMINUM ARCHITECT AMPERE TRIP (CIRCUIT BREAKER RATING) AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GUAGE BUILDING CONDUIT CIRCUIT BREAKER CURRENT TRANSFORMER CATALOG CIRCUIT COLUMN COPPER DELTA DRAWING WIRED ON EMERGENCY CIRCUIT EMPTY CONDUIT EMERGENCY FLUSH FEET GROUND ONE THOUSAND CIRCULAR MILS KILOVOLT- AMPERES KIL ❑VOLT- AMPERES REACTIVE KIL ❑WATTS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MISCELLANE ❑US MAIN LUGS ONLY N❑RMALLT CLOSED NATIONAL ELECTRICAL CODE NIGHT LIGHT NORMALLY OPEN NOT TO SCALE PHASE PETE POTENTIAL TRANSFORMER POLYVINYL CHL ❑RIDE RECESSED SURFACE SHORT CIRCUIT INTERRUPTING RATING SPARE SWITCH TELEPHONE UNDERGROUND VOLT WYE WATT WEATHERPROOF TRANSFORMER WARNING LIGHT EXISTING TO REMAIN GROMMET CABLE OPENING UPS DISCONNECT VOICE STAFF NURSE CALL DOME LIGHT SING CONTRACTOR AND CONNECTED BY THE ELECTRICAL CONTRACTOR. 14. ARCHITECTURAL AND /OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS OR SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY THE CONTRACTOR. GENERAL NOTES: A. REFER TO VENDOR'S DRAWINGS FOR ELECTRICAL REQUIREMENTS AND PROJECT INSTALLATION PROVIDE ALL CIRCUIT BREAKERS, SWITCHES, PUSHBUTTONS, LOAD CENTERS, ELECTRICAL DUCTS, CONDUIT, WIRING, BACK BOXES, ELECTRICAL DEVICES, AND GROUNDING AS REQUIRED BY THE VENDOR DRAWINGS. COORDINATE ALL WORK WITH VENDOR. PROVIDE ALL FINAL TERMINATIONS AS DIRECTED BY THE VENDOR. PERFORM ALL WORK IN ACCORDANCE WITH NEC AND NFPA 99. B. CONTRACTOR TO OBTAIN A LISTING FROM THE MANUFACTURER OF ALL INTERCONNECTING CABLES IDENTIFYING THE USE, TYPE OF CABLE, AND CLASS OF THE SYSTEM (I.E., POWER, COMMUNICATION, CLASS 1, CLASS 2, ETC.) FOR FIELD VERIFICATION ON THE SEPARATION OF THE DIFFERENT WIRING SYSTEMS. C. ALL EQUIPMENT MUST BE BONDED TO THE RACEWAY SYSTEM, WHERE FLEXIBILITY IS REQUIRED, FLEXIBLE METAL CONDUIT SHALL BE USED AS PERMITTED BY THE NEC. WHERE THE DEGREE OF FLEXIBILITY DOES NOT ALLOW THE USE OF FLEXIBLE METAL CONDUIT, A MULTISTRANDED INSULATED COPPER CONDUCTOR MAY BE UTILIZED. D. CONTRACTOR SHALL COORDINATE WITH RADIOLOGY VENDOR DRAWINGS AND PURCHASE ELECTRICAL DUCT WITH SHEET METAL DIVIDERS TO PROVIDE SEPARATION FOR THE FOLLOWING CABLE TYPES: (1) 24 VOLT (2) 300 VOLTS AND LESS (3) 301 -600 VOLTS -� W O (� W U_ a 0 � co C_ U) r � M 0 • CO 0 C) CO .� CU a) 75 _ >� �Q �� U) 2i QC/) > Q tCS � CV m (4) HIGH TENSION X -RAY CABLES 4 3 2 i 1 5 -B o -� STAFF EMERGENCY STATI ❑N � N E. ALL SECTIONS OF RACEWAY AND CONDUIT SHALL BE GROUNDED WITH AN INDEPENDENT #6 AWG GREEN C:> w WIRE THAT IS TO BE ATTACHED USING SOLDERLESS LUGS. ALL CEILING MOUNTED STRUCTURAL SUPPORT SUED FOR MEMBERS AND CEILING PLATES SHALL ALSO BE GROUNDED. ALL GROUNDING CONNECTIONS, TERMINALS, ETC. NOTE: NURSE CALL REMOTE LOCATOR RECEIVER, I PERMIT A �1 D N W w o 1. BALLASTS SHALL BE PROGRAM RAPID START MULTI VOLTAGE B TOILET EMERGENCY STATION F. PROVIDE A #10 GREEN INSULATED CONTINUOUS COPPER CONDUCTOR IN 1 /2 "CONDUIT TO BOND ALL WIREWAYS U w �' w o T) AND EQUIPMENT WITH THE PANELS SERVING THE ROOM TO MAINTAIN EQUIPOTENTIAL. CONSTRUCTION N " GENERAL ELECTRICAL NOTES CORRID ❑R DOME LIGHT WALL MOUNTED N k ia H. TEST THE EFFECTIVENESS OF THE GROUNDING SYSTEM BY VOLTAGE AND IMPEDANCE MEASUREMENTS AS a . w w O z =� REQUIRED BY NFPA 99, SECTION 4.3.3. RECORD THE RESULTS AND MAKE THEM AVAILABLE TO THE NURSE CALL EQUIPMENT CABINET DATE. AUTHORITY HAVING JURISDICTION AT THE TIME OF FINAL INSPECTION BY THESE AUTHORITIES. 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH ALL LOCAL CODES AND ORDINANCES, NURSE CALL SYSTEM CONDUIT AND WIRING 02/27/2009 2. UNLESS OTHERWISE NOTED ALL INTERIOR CONDUCTORS SHALL BE COPPER WITH THHN INSULATION AND ALL EXTERIOR OR IN GROUND SHALL BE THWN INSULATION, CLIENT CODE /FILE ALL CONDUCTORS SHALL BE STRANDED, NUMBER: 3. ALL RACEWAYS SHALL COMPLY WITH THE GOVERNING CODES, EXCEPT E.M.T PROJECT ID- SUBMISSION SHALL NOT BE USED AT THE EXTERIOR OF A BUILDING OR AT LOCATIONS NUMBER: SUBJECT TO SEVERE CORROSION. 4. OUTLET BOXES SHALL BE STAMPED STEEL IN DRY LOCATIONS, CAST ALLOY ROBERT BROWN W /THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES ARCHITECT FOR OTHER CLASSIFIED AREAS. LICENSE # AR92624 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, GENERAL OR HEAVY DUTY, QUICK -MAKE, QUICK -BREAK ENCLOSURES AS REQUIRED BY EXPOSURE. 6. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ITEMS FOR COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. 7. ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED Architecture AS REQUIRED BY THE LATEST EDITION OF THE N.E.C. Facility Assessments 8. LOAD DATA IS BASED ON INFORMATION PROVIDED BY OWNER AT TIME OF Planning Interior Design DESIGN, VERIFY ALL EQUIPMENT AND PANEL SIZES. 9. ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITERS' AND UNION LABELS, WHERE APPLICABLE. 10. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST -CLASS WORKMAN -LIKE MANNER, THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE, AND ACCEPTANCE BY OWNER MUST BE A CONDITION OF THE CONTRACT. 11, THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS , OF THE LOCAL POWER AND LIGHT COMPANY AND THE LOCAL TELEPHONE COMPANY. LINER 5, inc. 12. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. 420 LINCOLN ROAD, SUITE 258 THE CONTRACTOR SHALL PROVIDE CIRCUITS AND ROUTING OF CONDUIT TO SUIT MIAMI BEACH, FLORIDA 33139 JOB CONDITIONS. 305- 673 -0004 13. FURNISH AND INSTALL DISCONNECTED SWITCHES, WIRING AND CONNECTIONS FAX305- 673 -0080 ON AIR CONDITIONING SYSTEM AS SHOWN ON PLANS. CONTROLS ARE TO BE SUPPLIED BY THE AIR CONDITIO SING CONTRACTOR AND CONNECTED BY THE ELECTRICAL CONTRACTOR. 14. ARCHITECTURAL AND /OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS OR SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY THE CONTRACTOR. GENERAL NOTES: A. REFER TO VENDOR'S DRAWINGS FOR ELECTRICAL REQUIREMENTS AND PROJECT INSTALLATION PROVIDE ALL CIRCUIT BREAKERS, SWITCHES, PUSHBUTTONS, LOAD CENTERS, ELECTRICAL DUCTS, CONDUIT, WIRING, BACK BOXES, ELECTRICAL DEVICES, AND GROUNDING AS REQUIRED BY THE VENDOR DRAWINGS. COORDINATE ALL WORK WITH VENDOR. PROVIDE ALL FINAL TERMINATIONS AS DIRECTED BY THE VENDOR. PERFORM ALL WORK IN ACCORDANCE WITH NEC AND NFPA 99. B. CONTRACTOR TO OBTAIN A LISTING FROM THE MANUFACTURER OF ALL INTERCONNECTING CABLES IDENTIFYING THE USE, TYPE OF CABLE, AND CLASS OF THE SYSTEM (I.E., POWER, COMMUNICATION, CLASS 1, CLASS 2, ETC.) FOR FIELD VERIFICATION ON THE SEPARATION OF THE DIFFERENT WIRING SYSTEMS. C. ALL EQUIPMENT MUST BE BONDED TO THE RACEWAY SYSTEM, WHERE FLEXIBILITY IS REQUIRED, FLEXIBLE METAL CONDUIT SHALL BE USED AS PERMITTED BY THE NEC. WHERE THE DEGREE OF FLEXIBILITY DOES NOT ALLOW THE USE OF FLEXIBLE METAL CONDUIT, A MULTISTRANDED INSULATED COPPER CONDUCTOR MAY BE UTILIZED. D. CONTRACTOR SHALL COORDINATE WITH RADIOLOGY VENDOR DRAWINGS AND PURCHASE ELECTRICAL DUCT WITH SHEET METAL DIVIDERS TO PROVIDE SEPARATION FOR THE FOLLOWING CABLE TYPES: (1) 24 VOLT (2) 300 VOLTS AND LESS (3) 301 -600 VOLTS -� W O (� W U_ a 0 � co C_ U) r � M 0 • CO 0 C) CO .� CU a) 75 _ >� �Q �� U) 2i QC/) > Q tCS � CV m (4) HIGH TENSION X -RAY CABLES NURSE CALL - SINGLE PATIENT STATION (5) VIDEO CABLES -B o -� STAFF EMERGENCY STATI ❑N � N E. ALL SECTIONS OF RACEWAY AND CONDUIT SHALL BE GROUNDED WITH AN INDEPENDENT #6 AWG GREEN C:> w WIRE THAT IS TO BE ATTACHED USING SOLDERLESS LUGS. ALL CEILING MOUNTED STRUCTURAL SUPPORT NURSE CALL / TV PILLOW SPEAKER MEMBERS AND CEILING PLATES SHALL ALSO BE GROUNDED. ALL GROUNDING CONNECTIONS, TERMINALS, ETC. Ca NURSE CALL REMOTE LOCATOR RECEIVER, SHALL BE INSTALLED IN A MANNER TO PROVIDE ACCESSIBILITY FOR INSPECTION, MAINTENANCE, REPAIRS, ETC. N W w o REFER TO VENDOR DRAWINGS FOR ADDITIONAL GROUNDING REQUIREMENTS. B TOILET EMERGENCY STATION F. PROVIDE A #10 GREEN INSULATED CONTINUOUS COPPER CONDUCTOR IN 1 /2 "CONDUIT TO BOND ALL WIREWAYS U w �' w o T) AND EQUIPMENT WITH THE PANELS SERVING THE ROOM TO MAINTAIN EQUIPOTENTIAL. -� N " G. COORDINATE WITH THE VENDOR FOR EXACT LOCATIONS OF ALL ELECTRICAL EQUIPMENT. CORRID ❑R DOME LIGHT WALL MOUNTED N k ia H. TEST THE EFFECTIVENESS OF THE GROUNDING SYSTEM BY VOLTAGE AND IMPEDANCE MEASUREMENTS AS a . w w O z =� REQUIRED BY NFPA 99, SECTION 4.3.3. RECORD THE RESULTS AND MAKE THEM AVAILABLE TO THE NURSE CALL EQUIPMENT CABINET p ° w AUTHORITY HAVING JURISDICTION AT THE TIME OF FINAL INSPECTION BY THESE AUTHORITIES. w Q U 1 � H w w NURSE CALL SYSTEM CONDUIT AND WIRING �N NURSE CALL - SINGLE PATIENT STATION DUTY STATI ❑N -B STAFF STATION -� STAFF EMERGENCY STATI ❑N -� STAFF EMERGENCY ANNUNCIATOR NURSE CALL BED INTERFACE OUTLET ry NURSE CALL / TV PILLOW SPEAKER INTERFACE OUTLET RL NURSE CALL REMOTE LOCATOR RECEIVER, CEILING MOUNTED B EMERGENCY STATI ❑N B TOILET EMERGENCY STATION -B SHOWER EMERGENCY STATI ❑N CODE BLUE EMERGENCY STATION -� CODE PINK - INFANT EMERGENCY CORRID ❑R DOME LIGHT WALL MOUNTED -B ZONE LIGHT WALL MOUNTED CBAP CODE BLUE ANNUNCIAT ❑R PANEL WALL MOUNTED NCEC NURSE CALL EQUIPMENT CABINET NrCiAS NURSE CALL ANNUNCIATER STATION NURSE CALL SYSTEM CONDUIT AND WIRING ELECTRICAL DRAWING INDE) E -1 LEGEND AND NOTES - ELECTRICAL E -2 DEMOLITION PLAN LIGHTING AND POWER - ELECTRICAL E -3 RENOVATION PLAN LIGHTING AND POWER - ELECTRICAL E -4 RISER & PANEL - ELECTRICAL NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT. n- w 0� Li w Q L Q z M) Z Z � `n w Q J > w Q Q 0 J �Zw V)< �¢ Z Lj Q U w V �w ow Q w ❑ ❑ I NO DESCRIPTION DATE I JOB NQ 40827.00 DRAWN BY CHECKED B I.Q D.D DATE SCALE N.T.S Q ` SHEET NO fq, E I I 1 OF 3 ` ,gg f + I O U x U) m 70 U O a H m L 0 a_ ILL x U) (3) O ILL a� 0 a-